Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Chemosphere ; 364: 143128, 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39159769

RESUMEN

Reclaimed water poses environmental and human health risks due to residual organic micropollutants and pathogens. Ozonation of reclaimed water to control pathogens and trace organics is an important step in advanced water treatment systems for potable reuse of reclaimed water. Ensuring efficient pathogen reduction while controlling disinfection byproducts remains a significant challenge to implementing ozonation in reclaimed water reuse applications. This study aimed to investigate ozonation conditions using a plug flow reactor (PFR) to achieve effective pathogen removal/inactivation while minimizing bromate and N-Nitrosodimethylamine (NDMA) formation. The pilot scale study was conducted using three doses of ozone (0.7, 1.0 and 1.4 ozone/total organic carbon (O3/TOC) ratio) to determine the disinfection performance using actual reclaimed water. The disinfection efficiency was assessed by measuring total coliforms, Escherichia coli (E. coli), Pepper Mild Mottle Virus (PMMoV), Tomato Brown Rugose Fruit Virus (ToBRFV) and Norovirus (HNoV). The ozone CT values ranged from 1.60 to 13.62 mg min L-1, resulting in significant reductions in pathogens and indicators. Specifically, ozone treatment led to concentration reductions of 2.46-2.89, 2.03-2.18, 0.46-1.63, 2.23-2.64 and > 4 log for total coliforms, E. coli, PMMoV, ToBRFV, and HNoV, respectively. After ozonation, concentrations of bromate and NDMA increased, reaching levels between 2.8 and 12.0 µg L-1, and 28-40.0 ng L-1, respectively, for average feed water bromide levels of 86.7 ± 1.8 µg L-1 and TOC levels of 7.2 ± 0.1 mg L-1. The increases in DBP formation were pronounced with higher ozone dosages, possibly requiring removal/control in subsequent treatment steps in some potable reuse applications.

2.
J Hazard Mater ; 478: 135518, 2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-39154474

RESUMEN

The solid culture method for measuring the efficiency of ultraviolet (UV) disinfection of airborne bacteria is time-consuming, typically taking 12-48 h. To expedite such experiments, this study proposed a liquid culture method assisted by adenosine triphosphate (ATP) analysis, as a liquid culture is faster than a solid culture, and measurement of ATP does not require waiting for visible colonies to form. Escherichia coli (E. coli) was used as the experimental bacterium. This study first compared the log reduction of bacteria in liquid as measured by the proposed method and by the traditional solid culture method. The minimum liquid culture time was determined for different bacterial concentration ranges. Finally, the feasibility of the proposed method was validated by UV disinfection experiments on airborne bacteria. The results indicated that the proposed method measured a similar log reduction to that of the solid culture method in liquid experiments. The minimum liquid culture time for E. coli in 105-106 colony forming units (CFU)/mL was 2 h. The validation experiments demonstrated that the proposed method is capable of measuring the UV disinfection efficiency of airborne bacteria. The proposed method can accelerate laboratory experiments on UV disinfection of airborne bacteria, which in turn can support the effective design and utilization of UV disinfection in real life.


Asunto(s)
Adenosina Trifosfato , Microbiología del Aire , Desinfección , Escherichia coli , Rayos Ultravioleta , Adenosina Trifosfato/metabolismo , Adenosina Trifosfato/análisis , Desinfección/métodos , Escherichia coli/efectos de la radiación , Escherichia coli/crecimiento & desarrollo
3.
Environ Sci Pollut Res Int ; 31(35): 48279-48295, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39023724

RESUMEN

Solar disinfection (SODIS) is an affordable and sustainable Household Water Treatment (HWT) method endorsed by WHO. However, its limitations include longer sunlight exposure requirements, incomplete microbial inactivation, and post-SODIS microbial regrowth during monsoon and winter seasons in subtropical climates. To address these limitations, the performance of SODIS with H2O2 for microbial inactivation during the monsoon and winter seasons in Bangladesh was evaluated following the WHO HWT protocols. Moreover, the process was verified using drinking water samples collected from restaurants, households, and slums. All SODIS experiments were conducted using reflective reactors with PET bottles and plastic bags, adding 10 mg/L of H2O2, and exposing them to sunlight for 6 h. The results showed that E. coli was completely inactivated within 2 h in plastic bags and within 3 h in PET bottles during the monsoon season, achieving an LRV of > 5. In winter, both achieved an LRV > 5 within 3 h and plastic bags showed more efficient in microbial inactivation than PET bottles. The microbial inactivation rates were 5 times higher than those of conventional SODIS. No regrowth of microorganisms was observed during the subsequent post-SODIS period of 12 h and 24 h at room temperature. The study findings suggest that SODIS with H2O2 has the potential for complete microorganism inactivation with shorter sunlight exposure in subtropical climates with moderate to low solar irradiation and can be adopted as a reliable disinfection option for rural and urban communities with unsafe drinking water supply.


Asunto(s)
Desinfección , Peróxido de Hidrógeno , Purificación del Agua , Bangladesh , Purificación del Agua/métodos , Desinfección/métodos , Luz Solar , Clima Tropical , Agua Potable/microbiología , Escherichia coli/efectos de los fármacos
4.
Water Environ Res ; 96(7): e11072, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38961619

RESUMEN

This work assessed the performance of a pilot-scale cascade anaerobic digestion (AD) system when treating mixed municipal wastewater treatment sludges. The cascade system was compared with a conventional continuous stirred tank reactor (CSTR) digester (control) in terms of process performance, stability, and digestate quality. The results showed that the cascade system achieved higher volatile solids removal (VSR) efficiencies (28-48%) than that of the reference (25-41%) when operated at the same solids residence time (SRT) in the range of 11-15 days. When the SRT of the cascade system was reduced to 8 days the VSR (32-36%) was only slightly less than that of the reference digester that was operated at a 15-day SRT (39-43%). Specific hydrolysis rates in the first stage of the cascade system were 66-152% higher than those of the reference. Additionally, the cascade system exhibited relatively stable effluent concentrations of volatile fatty acids (VFAs: 100-120 mg/l), while the corresponding concentrations in the control effluent demonstrated greater fluctuations (100-160 mg/l). The cascade system's effluent pH and VFA/alkalinity ratios were consistently maintained within the optimal range. During a dynamic test when the feed total solids concentration was doubled, total VFA concentrations (85-120 mg/l) in the cascade system were noticeably less than those (100-170 mg/l) of the control, while the pH and VFA/alkalinity levels remained in a stable range. The cascade system achieved higher total solids (TS) content in the dewatered digestate (19.4-26.8%) than the control (17.4-22.1%), and E. coli log reductions (2.0-4.1 log MPN/g TS) were considerably higher (p < 0.05) than those in the control (1.3-2.9 log MPN/g TS). Overall, operating multiple CSTRs in cascade mode at typical SRTs and mixed sludge ratios enhanced the performance, stability digesters, and digestate quality of AD. PRACTITIONER POINTS: Enhanced digestion of mixed sludge digestion with cascade system. Increased hydrolysis rates in the cascade system compared to a reference CSTR. More stable conditions for methanogen growth at both steady and dynamic states. Improved dewaterability and E. coli reduction of digestate from the cascade system.


Asunto(s)
Reactores Biológicos , Aguas del Alcantarillado , Eliminación de Residuos Líquidos , Aguas Residuales , Anaerobiosis , Eliminación de Residuos Líquidos/métodos , Proyectos Piloto , Aguas Residuales/química , Aguas del Alcantarillado/química , Ácidos Grasos Volátiles/metabolismo , Purificación del Agua/métodos
5.
Water Res X ; 23: 100226, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38765690

RESUMEN

Pathogen reduction for the purpose of human health protection is a critical function provided by water reuse systems. Pathogen reduction performance potential is dependent on a wide range of design and operational parameters. Poor understanding of pathogen reduction performance has important consequences-under treatment can jeopardize human health, while over treatment can lead to unnecessary costs and environmental impacts. Documented pathogen reduction potential of the unit processes that make up water reuse treatment trains is based on a highly dispersed and unstructured literature, creating an impediment to practitioners looking to design, model or simply better understand these systems. This review presents a database of compiled log reduction values (LRVs) and log reduction credits (LRCs) for unit processes capable of providing some level of pathogen reduction, with a focus on processes suitable for onsite non-potable water reuse systems. Where reported, we have also compiled all relevant design and operational factors associated with the LRVs and LRCs. Overall, we compiled over 1100 individual LRV data entries for 31 unit processes, and LRCs for 8 unit processes. Results show very inconsistent reporting of influencing parameters, representing a limitation to the use of some of the data. As a standalone resource, the database (included as Supplemental Information) provides water reuse practitioners with easy access to LRV and LRC data. The database is also part of a longer-term effort to optimize the balance between human health protection, potential environmental impacts and cost of water reuse treatment trains.

6.
Water Res ; 256: 121556, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38604066

RESUMEN

Water reuse as an alternative water supply is increasing throughout the world due to water stress and scarcity; however, there are no standard practices for monitoring virus pathogens in such systems. This study aimed to identify suitable surrogates for virus fate, transport, and removal throughout a water reuse scheme. Various microbial targets (11 viruses, two phage, and three bacteria) were monitored using molecular and culture methods across all treatment stages in a wastewater reclamation facility and advanced water treatment facility. Criteria were established for identifying suitable surrogates, which included reliable detection, observable fate and transport, calculable log-reduction values (LRVs), correlations with other targets, and various morphological types. In total, five viruses (PMMoV, AiV, GII NoV, AdV, FRNA GII) met these stringent criteria and were suggested as potential virus surrogates. These surrogates enabled successful comparison of assigned versus actual LRVs throughout a water reuse scheme. Results suggest that virus pathogens are effectively removed throughout water reuse treatment and the suggested surrogates can be utilized for monitoring treatment performance and ensuring public health safety. This study provides a framework that water utilities across the world can reference for establishing virus monitoring practices.


Asunto(s)
Microbiología del Agua , Purificación del Agua , Virus/aislamiento & purificación , Aguas Residuales/virología , Abastecimiento de Agua , Eliminación de Residuos Líquidos/métodos , Bacteriófagos , Reciclaje , Bacterias
7.
Infect Dis Health ; 28(3): 195-201, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37005216

RESUMEN

BACKGROUND: The effectiveness of hand sanitizers marketed to the general population is essential for infection prevention and control. Main theme of the study was that whether the commercially available hand sanitizers meet the WHO recommended standards in terms of efficacy? Current study aims to investigate the efficacy of ten commercially available hand sanitizers. METHODS: The methodology was based on European Standard EN-1500. Following the artificial contamination of hands, pre and post samples were obtained to determine the log reduction values for each sanitizer. RESULTS: The results showed that out of ten only one sanitizer showed highest log reduction which was comparable to the reference product. Product B was most efficient in sanitization of hands with mean log reduction of 6.00 ± 0.15. The lowest sanitization efficacy was recorded for product F with mean log reduction of 2.40 ± 0.51, however the reference product 2-propanol result in mean log reduction of 6.0 ± 0.00. The products used in this study show a statistical significant results (p value: < 0.01). CONCLUSION: It is concluded that only one product showed active sanitizer efficacy. This study provides an important insight for manufacturing company and authorizing authorities to assess the efficacy of hand sanitizer. Hand sanitization is one approach to stop the spread of diseases carried on by harmful bacteria inhabiting our hands. Apart from the manufacturing strategies, ensuring proper use and quantity of hand sanitizers is very important.


Asunto(s)
Desinfectantes para las Manos , Humanos , Desinfectantes para las Manos/farmacología , Pakistán , Desinfección de las Manos , 1-Propanol , Antibacterianos
8.
Water Res ; 235: 119836, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-36931188

RESUMEN

Pathogen removal in managed aquifer recharge (MAR) systems is dependent upon numerous operational, physicochemical water quality, and biological parameters. Due to the site-specific conditions affecting these parameters, guidelines for specifying pathogen removal have historically taken rather precautionary and conservative approaches in order to protect groundwater quality and public health. A literature review of regulated pathogens in MAR applications was conducted and compared to up-and-coming indicators and surrogates for pathogen assessment, all of which can be gathered into a toolbox from which regulators and operators alike can select appropriate pathogens for monitoring and optimization of MAR practices. Combined with improved knowledge of pathogen fate and transport obtained through lab- and pilot-scale studies and supported by modeling, this foundation can be used to select appropriate, site-specific pathogens for regarding a more efficient pathogen retention, ultimately protecting public health and reducing costs. This paper outlines a new 10 step-wise workflow for moving towards determining robust removal credits for pathogens based on risk management principles. This approach is tailored to local conditions while reducing overly conservative regulatory restrictions or insufficient safety contingencies. The workflow is intended to help enable the full potential of MAR as more planned water reuse systems are implemented in the coming years.


Asunto(s)
Agua Subterránea , Flujo de Trabajo
9.
Sci Total Environ ; 851(Pt 2): 158310, 2022 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-36030862

RESUMEN

The potential risk of SARS-CoV-2 in treated effluent from a wastewater treatment plant (WWTP) is concerned since SARS-CoV-2 is contained in wastewater during the COVID-19 outbreak. However, the removal of SARS-CoV-2 in WWTP has not been well investigated. The objectives of this study were (i) to clarify the removal performance of SARS-CoV-2 during wastewater treatment, (ii) to compare the removal performance of different secondary treatment processes, and (iii) to evaluate applicability of pepper mild mottle of virus (PMMoV) as a performance indicator for the reduction of SARS-CoV-2 RNA in wastewater treatment. Influent wastewater, secondary-treatment effluent (before chlorination), and final effluent (after chlorination) samples were collected from a WWTP from May 28 to September 24, 2020, during the COVID-19 outbreak in Japan. The target WWTP had three parallel treatment systems employing conventional activated sludge (CAS), anaerobic-anoxic -oxic (A2O), and membrane bioreactor (MBR) processes. SARS-CoV-2 in both the liquid and solid fractions of the influent wastewater was concentrated and quantified using RT-qPCR. SARS-CoV-2 in treated effluent was concentrated from 10 L samples to achieve a detection limit as low as 10 copies/L. The log reduction value (LRV) of SARS-CoV-2 was 2.7 ± 0.86 log10 in CAS, 1.6 ± 0.50 log10 in A2O, and 3.6 ± 0.62 log10 in MBR. The lowest LRV observed during the sampling period was 2.8 log10 in MBR, 1.2 log10 in CAS, and 1.0 log10 in A2O process, indicating that the MBR had the most stable reduction performance. PMMoV was found to be a good indicator virus to evaluate reduction performance of SARS-CoV-2 independent of the process configuration because the LRV of PMMoV was significantly lower than that of SARS-CoV-2 in the CAS, A2O and MBR processes.


Asunto(s)
COVID-19 , Purificación del Agua , Humanos , Aguas del Alcantarillado , SARS-CoV-2 , Aguas Residuales , Anaerobiosis , ARN Viral , Reactores Biológicos , Eliminación de Residuos Líquidos
10.
Water Res ; 221: 118827, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35820313

RESUMEN

Viral indicators of human-fecal contamination in wastewaters and environmental waters have been getting much attention in the past decade. Cross-assembly phage (crAssphage) is the most abundant DNA virus in human feces. Recently, the usefulness of crAssphage as a microbial source tracking and water quality monitoring tool for human-fecal contamination has been highlighted. Here, we conducted a comprehensive review on crAssphage in water, focusing on detection methodology, concentration range in various waters and wastewaters, specificity to human-fecal contamination, and reduction in wastewater treatment systems. This review highlights that crAssphage is globally distributed in wastewaters and various fecal-contaminated water bodies at high concentrations without seasonal fluctuations. CrAssphage is highly specific to human-fecal contamination and is rarely found in animal feces. It also has a good potential as a performance indicator to ensure virus reduction in wastewater treatment systems. Accordingly, crAssphage could be an effective tool for monitoring of human-fecal contamination and potential presence of fecal pathogenic microbes in environmental waters. Bridging the research gaps highlighted in this review would make crAssphage a powerful tool to support the control of water-related health risks.


Asunto(s)
Bacteriófagos , Virus , Purificación del Agua , Animales , Monitoreo del Ambiente/métodos , Heces , Humanos , Virus/genética , Aguas Residuales , Microbiología del Agua , Contaminación del Agua/análisis
11.
Microorganisms ; 10(7)2022 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-35889027

RESUMEN

Biltong is a dry beef product that is manufactured without a heat lethality step, raising concerns of whether effective microbial pathogen reduction can occur during biltong processing. Raw beef inoculated with 4-strain cocktails of either E. coli O157:H7, Listeria monocytogenes, or Staphylococcus aureus, and processed with a standard biltong process, were shown to incur a >5-log reduction in 6−8 days after marination by vacuum-tumbling for 30 min in vinegar, salt, spices (coriander, pepper) when dried at 23.9 °C (75 °F) at 55% relative humidity (RH). Pathogenic challenge strains were acid-adapted in media containing 1% glucose to ensure that the process was sufficiently robust to inhibit acid tolerant strains. Internal water activity (Aw) reached < 0.85 at 5-log reduction levels, ensuring that conditions were lower than that which would support bacterial growth, or toxin production by S. aureus should it be internalized during vacuum tumbling. This was further confirmed by ELISA testing for staphylococcal enterotoxins A and B (SEA, SEB) after marination and again after 10 days of drying whereby levels were lower than initial post-marination levels. Comparison of log reduction curves obtained for E. coli O157:H7, L. monocytogenes, S. aureus, and Salmonella (prior study) showed that microbial reduction was not significantly different (p < 0.05) demonstrating that even without a heat lethality step, the biltong process we examined produces a safe beef product according to USDA-FSIS guidelines.

12.
Water Res ; 206: 117735, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34673461

RESUMEN

Treatment of wastewater for potable reuse is increasingly becoming a suitable alternative water source to meet the growing urban water needs worldwide. Potable reuse requires reduction of enteric viruses to levels at which they do not pose a risk to human health. Advanced water treatment trains (e.g., microfiltration (MF), ultrafiltration (UF), reverse osmosis (RO), and ultraviolet light and advanced oxidation process (UV/AOP)) provide significant protection and reduce virus loads in highly treated final product waters. Even though viruses are a principal concern, the performance of virus removal by membrane processes is not easily determined. The objective of this study was to evaluate the applicability of Aichi virus (AiV), pepper mild mottle virus (PMMoV), cucumber green mottle mosaic virus (CGMMV), and cross-assembly phage (crAssphage) removal as possible process indicators for MF, UF, and RO. Virus log reduction values (LRVs) based on gene copies measured using molecular methods were determined for MF and UF. The median LRVs of all viruses obtained after MF and UF were 2.9 and 3.1, respectively. The LRVs of the proposed indicators were lower than those of human enteric viruses. The morphological and physicochemical difference among indicators was not found to affect LRVs. Therefore, all proposed indicator viruses were determined to be suitable candidates as process indicators for MF and UF. Regarding RO, most of the viruses measured in this study were undetectable in permeate. Only PMMoV and CGMMV were detected showing median LRVs of 2.8 and 2.5, respectively. PMMoV and CGMMV are recommended as good process indicators of physical virus removal for the overall water treatment process.


Asunto(s)
Enterovirus , Tobamovirus , Purificación del Agua , Humanos , Ultrafiltración
13.
Appl Environ Microbiol ; 87(19): e0109821, 2021 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34288707

RESUMEN

A novel and robust approach to evaluate the antiviral activity of coatings was developed, assessing three commercially available leave-on surface coating products for efficacy against human coronaviruses (HCoVs) HCoV-229E and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The assessment is based on three criteria that reflect real-life settings, namely, (i) immediate antiviral effect, (ii) effect after repeated cleaning of the coated surface, and (iii) antiviral activity in the presence of organic material. The results showed that only a copper compound-based coating successfully met all three criteria. A quaternary ammonium compound-based coating did not meet the second criterion, and a coating based on reactive oxygen species showed no antiviral effect. Moreover, the study demonstrated that HCoV-229E is a relevant SARS-CoV-2 surrogate for such experiments. This new approach allows benchmarking of currently available antiviral coatings and future coating developments to avoid unjustified claims. The deployment of efficient antiviral coatings can offer an additional measure to mitigate the risk of transmission of respiratory viruses like SARS-CoV-2 or influenza viruses from high-touch surfaces. IMPORTANCE SARS-CoV-2, the virus responsible for the coronavirus disease 2019 (COVID-19) pandemic, is transmitted mainly person-to-person through respiratory droplets, while the contribution of fomite transmission is less important than suspected at the beginning of the pandemic. Nevertheless, antiviral-coating solutions can offer an additional measure to mitigate the risk of SARS-CoV-2 transmission from high-touch surfaces. The deployment of antiviral coatings is not new, but what is currently lacking is solid scientific evidence of the efficacy of commercially available self-disinfecting surfaces under real-life conditions. Therefore, we developed a novel, robust approach to evaluate the antiviral activity of such coatings, applying strict quality criteria to three commercially available products to test their efficacies against SARS-CoV-2. We also showed that HCoV-229E is a relevant surrogate for such experiments. Our approach will also bring significant benefit to the evaluation of the effects of coatings on the survival of nonenveloped viruses, which are known to be more tolerant to desiccation and disinfectants and for which high-touch surfaces play an important role.


Asunto(s)
Antivirales/farmacología , Coronavirus Humano 229E/efectos de los fármacos , Desinfectantes/farmacología , SARS-CoV-2/efectos de los fármacos
14.
Cytotherapy ; 23(10): 902-907, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34238658

RESUMEN

BACKGROUND AIMS: Platelet concentrates (PCs) are pooled to prepare human platelet lysate (HPL) supplements of growth media to expand primary human cells for transplantation; this increases the risk of contamination by known, emerging, and unknown viruses. This possibility should be of concern because viral contamination of cell cultures is difficult to detect and may have detrimental consequences for recipients of cell therapies. Viral reduction treatments of chemically defined growth media have been proposed, but they are not applicable when media contain protein supplements currently needed to expand primary cell cultures. Recently, we successfully developed a Planova 35NPlanova 20N nanofiltration sequence of growth media supplemented with two types of HPL. The nanofiltered medium was found to be suitable for mesenchymal Stromal cell (MSC) expansion. METHODS: Herein, we report viral clearance achieved by this nanofiltration process used for assessing a new experimental model using non-infectious minute virus of mice-mock virus particle (MVM-MVP) and its quantification by an immunoqPCR. Then, high doses of MVM-MVP (1012 MVPs/mL) were spiked to obtain a final concentration of 1010 MVPs/mL in Planova 35N-nanofiltered growth medium supplemented with both types of HPLs [serum converted platelet lysate SCPL) and intercept human platelet lysate (I-HPL)] at 10% (v/v) and then filtering through Planova 20N. RESULTS: No substantial interference of growth medium matrices by the immune-qPCR assay was first verified. Log reduction values (LRVs) were ≥ 5.43 and ≥ 5.36 respectively, SCPL and I-HPL media. MVM-MVPs were also undetectable by dynamic light scattering and transmission electron microscopy. CONCLUSIONS: The nanofiltration of growth media supplemented with 10% HPL provides robust removal of small nonenveloped viruses, and is an option to improve the safety of therapeutic cells expanded using HPL supplements.


Asunto(s)
Células Madre Mesenquimatosas , Virus Diminuto del Ratón , Animales , Técnicas de Cultivo de Célula , Medios de Cultivo , Humanos , Ratones , Virión
15.
Can J Microbiol ; 67(9): 657-666, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33844954

RESUMEN

A gap exists between good laboratory practices with axenic animals and the procedures applied. This work examined the efficacy of sodium dichloroisocyanurate (MB-10) and potassium peroxymonosulfate (Virkon™) disinfectants, as well as the appropriate soaking time for materials used with the ISOcage Biosafety Station™. We also compared the microbial load in cage systems hosting mice over 2 weeks in axenic rooms (ARs) and in typical specific-pathogen-free (SPF) non-axenic rooms (NARs) to identify resistant microorganisms, targeted for longer soaking disinfection, and evaluated the necessary procedures for reducing the microbial load in AR. Staphylococcus was the most frequently isolated genus (in both ARs and NARs). An average of three spore-forming microorganisms per cage were counted from AR. The disinfection time to reach 1 log reduction for Bacillus atrophaeus spores varied from 138 s (100 ppm MB-10) to 290 (Virkon™) to <20 s for S. epidermidis (100 ppm MB-10). AR management protocols lead to a microbial load that is 1000 times lower than that found in NARs. Data comparing the microbial load in SPF and axenic facilities can be used to improve the effectiveness of their microbial control procedures.


Asunto(s)
Desinfectantes , Esporas Bacterianas , Animales , Bacillus , Desinfectantes/farmacología , Desinfección , Vida Libre de Gérmenes , Ratones
16.
Water Res X ; 11: 100093, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33665597

RESUMEN

Wastewater reclamation and reuse have been practically applied to water-stressed regions, but waterborne pathogens remaining in insufficiently treated wastewater are of concern. Sanitation Safety Planning adopts the hazard analysis and critical control point (HACCP) approach to manage human health risks upon exposure to reclaimed wastewater. HACCP requires a predetermined reference value (critical limit: CL) at critical control points (CCPs), in which specific parameters are monitored and recorded in real time. A disinfection reactor of a wastewater treatment plant (WWTP) is regarded as a CCP, and one of the CCP parameters is the disinfection intensity (e.g., initial disinfectant concentration and contact time), which is proportional to the log reduction value (LRV) of waterborne pathogens. However, the achievable LRVs are not always stable because the disinfection intensity is affected by water quality parameters, which vary among WWTPs. In this study, we established models for projecting virus LRVs using ozone, in which water quality and operational parameters were used as explanatory variables. For the model construction, we used five machine learning algorithms and found that automatic relevance determination with interaction terms resulted in better prediction performances for norovirus and rotavirus LRVs. Poliovirus and coxsackievirus LRVs were predicted well by a Bayesian ridge with interaction terms and lasso with quadratic terms, respectively. The established models were relatively robust to predict LRV using new datasets that were out of the range of the training data used here, but it is important to collect LRV datasets further to make the models more predictable and flexible for newly obtained datasets. The modeling framework proposed here can help WWTP operators and risk assessors determine the appropriate CL to protect human health in wastewater reclamation and reuse.

17.
Environ Res ; 195: 110748, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33465345

RESUMEN

There is increasing interest in wastewater-based epidemiology (WBE) of SARS-CoV-2 RNA to serve as an early warning system for a community. Despite successful detection of SARS-CoV-2 RNA in wastewaters sampled from multiple locations, there is still no clear idea on the minimal number of cases in a community that are associated with a positive detection of the virus in wastewater. To address this knowledge gap, we sampled wastewaters from a septic tank (n = 57) and biological activated sludge tank (n = 52) located on-site of a hospital. The hospital is providing treatment for SARS-CoV-2 infected patients, with the number of hospitalized patients per day known. It was observed that depending on which nucleocapsid gene is targeted by means of RT-qPCR, a range of 253-409 positive cases out of 10,000 persons are required prior to detecting RNA SARS-CoV-2 in wastewater. There was a weak correlation between N1 and N2 gene abundances in wastewater with the number of hospitalized cases. This correlation was however not observed for N3 gene. The frequency of detecting N1 and N2 gene in wastewater was also higher than that for N3 gene. Furthermore, nucleocapsid genes of SARS-CoV-2 were detected at lower frequency in the partially treated wastewater than in the septic tank. In particular, N1 gene abundance was associated with water quality parameters such as total organic carbon and pH. In instances of positive detection, the average abundance of N1 and N3 genes in the activated sludge tank were reduced by 50 and 70% of the levels detected in septic tank, suggesting degradation of the SARS-CoV-2 gene fragments already occurring in the early stages of the wastewater treatment process.


Asunto(s)
COVID-19 , SARS-CoV-2 , Brotes de Enfermedades , Humanos , ARN Viral/genética , Aguas Residuales
18.
Front Plant Sci ; 12: 775629, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35087550

RESUMEN

Maintaining microbial safety and quality of fresh fruits and vegetables are a global concern. Harmful microbes can contaminate fresh produce at any stage from farm to fork. Microbial contamination can affect the quality and shelf-life of fresh produce, and the consumption of contaminated food can cause foodborne illnesses. Additionally, there has been an increased emphasis on the freshness and appearance of fresh produce by modern consumers. Hence, disinfection methods that not only reduce microbial load but also preserve the quality of fresh produce are required. Chlorine dioxide (ClO2) has emerged as a better alternative to chlorine-based disinfectants. In this review, we discuss the efficacy of gaseous and aqueous ClO2 in inhibiting microbial growth immediately after treatment (short-term effect) versus regulating microbial growth during storage of fresh produce (long-term effect). We further elaborate upon the effects of ClO2 application on retaining or enhancing the quality of fresh produce and discuss the current understanding of the mode of action of ClO2 against microbes affecting fresh produce.

19.
Sci Total Environ ; 752: 141705, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-32892039

RESUMEN

E. coli survival in biosolids storage may present a risk of non-compliance with guidelines designed to ensure a quality product safe for agricultural use. The storage environment may affect E. coli survival but presently, storage characteristics are not well profiled. Typically biosolids storage environments are not actively controlled or monitored to support increased product quality or improved microbial compliance. This two-phased study aimed to identify the environmental factors that control bacterial concentrations through a long term, controlled monitoring study (phase 1) and a field-scale demonstration trial modifying precursors to bacterial growth (phase 2). Digested and dewatered biosolids were stored in operational-scale stockpiles to elucidate factors controlling E. coli dynamics. E. coli concentrations, stockpile dry solids, temperature, redox and ambient weather data were monitored. Results from ANCOVA analysis showed statistically significant (p < 0.05) E. coli reductions across storage periods with greater die-off in summer months. Stockpile temperature had a statistically significant effect on E. coli survival. A 4.5 Log reduction was measured in summer (maximum temperature 31 °C). In the phase 2 modification trials, covered stockpiles were able to maintain a temperature >25 °C for a 28 day period and achieved a 3.7 Log E. coli reduction. In winter months E. coli suppression was limited with concentrations >6 Log10 CFU g-1 DS maintained. The ANCOVA analysis has identified the significant role that physical environmental factors, such as stockpile temperature, has on E. coli dynamics and the opportunities for control.


Asunto(s)
Escherichia coli , Aguas del Alcantarillado , Agricultura , Bacterias , Biosólidos , Recuento de Colonia Microbiana , Temperatura
20.
J Res Natl Inst Stand Technol ; 126: 126021, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-39081635

RESUMEN

Data concerning the sensitivity of various organisms to ultraviolet (UV) radiation exposure are very important in the design of UV disinfection equipment. This review analyzes fluence data from almost 250 studies and organizes the data into a set of recommended fluence values for specific log reductions and an appendix containing all the collected data. This article was sponsored by Dianne L. Poster, Material Measurement Laboratory, and C. Cameron Miller, Physical Measurement Laboratory, National Institute of Standards and Technology (NIST). It is published in collaboration with the International Ultraviolet Association as a complement to the NIST Workshop on Ultraviolet Disinfection Technologies, 14-15 January 2020, Gaithersburg, MD. The views expressed represent those of the authors and not necessarily those of NIST.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA