Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cir Cir ; 2024 Feb 12.
Artigo em Espanhol | MEDLINE | ID: mdl-38346348

RESUMO

Objective: To describe the use of negative pressure therapy with (TPNi) and without instillation (TPNs) as adjuvant treatment in the management of orthopedic device-associated infections (IADO). Method: Analytic observational study of records of patients with IADO managed with TPNi and TPNs with 0.9% saline solution, in patients > 18 years, operated on in 2018-2021. Clinical characteristics of infection, infectious agent as well as sociodemographic variables were evaluated. TPN was performed with the V.A.C. VERAFLO™ system. Analysis with χ2, Fisher and t-Student. Statistically accepted value p < 0.05. Results: Sample 40 patients. 75% male. Fractures 42.5% exposed and 57.5% closed. 92.5% applied prophylactic antibiotic (30-120 min). 35% plate implants, 12.5% centromedullary nail, 10% knee prosthesis and 12.5% hip. 47.5% bleeding < 500 ml. 72.5% surgical time of 2-4 hours. Previous hospitalization time, TPNs 3 weeks 55.9% and 4 weeks 26.5%; TPNi, 3 weeks 50% and 4 weeks 33.3%. Conservation of the implant 73.5% TPNs and 50% TPNi (p = 0.341). Wound closure 91.2% with TPNs and 100% with TPNi (p = 1.000). Conclusions: The use of TPNs and TPNi were useful as adjuvant treatments in the management of IADO, in addition they allowed to preserve the implant and wound closure in a large part of the patients.


Objetivo: Describir el uso de la terapia de presión negativa con (TPNi) y sin instilación (TPNs) como tratamiento adyuvante en el manejo de infecciones asociadas a dispositivo ortopédico (IADO). Método: Estudio observacional analítico de expedientes de pacientes con IADO manejados con TPNi y TPNs con solución salina al 0.9%, mayores de 18 años, operados en el periodo 2018-2021. Se evaluaron las características clínicas de infección, el agente infeccioso y las variables sociodemográficas. La TPN se realizó con sistema V.A.C.VERAFLO™. Para los análisis se emplearon las pruebas χ2, Fisher y t de Student. Valor estadísticamente aceptado: p < 0.05. Resultados: La muestra fue de 40 pacientes, el 75% masculinos. Fracturas: 42.5% expuestas y 57.5% cerradas. En el 92.5% se aplicó antibiótico profiláctico (30-120 min). Implantes: 35% placas, 12.5% clavo centromedular, 10% prótesis de rodilla y 12.5% cadera. El 47.5% con sangrado < 500 ml. En el 72.5% un tiempo quirúrgico de 2-4 horas. Tiempo de hospitalización previa: TPNs 3 semanas 55.9% y 4 semanas 26.5%; TPNi 3 semanas 50% y 4 semanas 33.3%. Conservación del implante: 73.5% TPNs y 50% TPNi (p = 0.341). Cierre de herida: 91.2% con TPNs y 100% con TPNi (p = 1.000). Conclusiones: El uso de TPNs y TPNi fue útil como tratamiento adyuvante en IADO, y además permitieron conservar el implante y el cierre de la herida en la mayoría de los pacientes.

2.
Rev. venez. cir. ortop. traumatol ; 55(1): 29-37, jun. 2023. ilus, graf
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1512029

RESUMO

Las fracturas supracondíleas en niños se asocian con algunas complicaciones. Su tratamiento estándar es la reducción cerrada y la fijación con alambres en distintas configuraciones. Se realizó un estudio observacional, analítico, prospectivo y longitudinal con pacientes pediátricos que ingresaron con fracturas supracondíleas de húmero tratados quirúrgicamente con alambres de Kirschner con "Técnica Cruzada" en el Hospital Central San Cristóbal enero a junio de 2022. Se incluyeron 30 pacientes. La edad promedio fue 6,3±2,2(3-10) años. La causa más frecuente del traumatismo fue la precipitación de altura en 63,3% de los casos. La posición del codo al momento del accidente fue en extensión en 90%. Todas las fracturas fueron cerradas. El tiempo promedio desde el accidente hasta su atención en emergencia fue de 8,5±13,4(2-72) horas. Los signos clínicos más frecuentes fueron dolor en 100,0%, limitación funcional en 96,7%, aumento de volumen 73,3% y deformidad 50,0%. Según la clasificación AO la más frecuente fue del tipo 13-M/3. 1 III en el 50% de los casos y según Gartland, las tipo IIIA en 53,3%. A las 4 semanas, 100,0% de las fracturas consolidaron, 13,3% presentó valgo y 6,7% varo en la radiografía anteroposterior. Mientras que, en la lateral, 33,3% antecurvatum. La media del ángulo de Baumann fue de 20,27±1,39 grados. La tasa de complicaciones fue de 16,66%, 2(6,7%) casos presentaron neuropraxia y 3(10,0%) granuloma. En conclusión, la Técnica Cruzada es segura en términos de reducción, funcionalidad y tasas de complicaciones en el seguimiento a medio plazo(AU)


Supracondylar fractures in children are associated with some complications. Its standard treatment is closed reduction and fixation with wires in different configurations. An observational, analytical, prospective and longitudinal study was made, with pediatric patients admitted with supracondylar humeral fractures surgically treated with Kirschner wires with the "Cross Technique" at the Hospital Central San Cristóbal from January to June 2022. 30 patients were included. The mean age was 6,3±2,2(3-10) years. The most frequent cause of trauma was high altitude precipitation in 63,3% of the cases. The position of the elbow at the time of the accident was 90% extended. All fractures were closed. The mean time from the accident to emergency care was 8,5±13,4(2-72) hours. The most frequent clinical signs were pain in 100,0%, functional limitation in 96.7%, volume increase in 73,3%, and deformity in 50,0%. According to the AO classification, the most frequent was type 13-M/3. 1 III in 50% of cases and according to Gartland, type IIIA in 53,3%. At 4 weeks, 100,0% of the patients consolidated, 13,3% presented valgus and 6,7% varus on the anteroposterior radiograph. While, on the side, 33,3% antecurvatum. The mean Baumann angle was 20,27 ± 1.39 degrees. The rate of complications was 16,66%, 2 (6,7%) cases presented neuropraxia and 3 (10,0%) granuloma. In conclusion, the Crossover Technique is safe in terms of reduction, functionality, and complication rates in medium-term follow-up(AU)


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Redução Fechada , Fraturas Fechadas , Fraturas Distais do Úmero , Dor
3.
Rev. venez. cir. ortop. traumatol ; 54(2): 53-61, dic. 2022. ilus
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1516086

RESUMO

La Impresión 3D es una tecnología emergente utilizada cada vez más en medicina. En los países en vías de desarrollo, donde las fracturas por motocicletas y automóviles se encuentran en aumento, la disponibilidad de fijadores externos para el manejo de fracturas abiertas es un problema frecuente. La impresión 3D puede ser una alternativa económica e igualmente confiable a los dispositivos tradicionales elaborados con acero o titanio. El objetivo de este trabajo es mostrar la experiencia con el uso de Impresión 3D y su aplicación en el manejo clínico de fracturas abiertas diafisiarias de tibia. Se realizó un estudio pre-experimental y prospectivo. Se incluyeron 14 pacientes con fracturas de tibia AO/ASIF 42A, 42B y 42C tratados con un fijador externo con rótulas elaboradas con Impresión 3D como medida de Control de Daños en Ortopedia desde su ingreso hasta su resolución definitiva. Todos los pacientes fueron de sexo masculino, con un promedio de edad 23,16 años con 50% entre 20-23 años. Las fracturas fueron 42,85% tipo 42A, 37,71% 42B y 21,42% 42C. El 78,57% de las fracturas fueron ocasionadas por motocicletas: 57,14% grado II según Gustilo y Anderson, un 28,57% grado III y 14,28% grado I. El 37,71% eran politraumatizados. Ninguno de los pacientes presentó complicaciones como pérdida de la reducción, aflojamiento de las rótulas, ruptura o fatiga de las rótulas ni fatiga de la barra. La impresión 3D demostró ser una herramienta y alternativa útil en el manejo agudo de fracturas abiertas diafisiarias de tibia(AU)


3D Printing is an emerging technology used more and more in medicine. In developing countries, where motorcycle and automobile fractures are on the rise, the availability of external fixators for the management of open fractures is a frequent problem. 3D printing can be a cheap and equally reliable alternative to traditional devices made of steel or titanium. The objective of this work is to show the experience with the use of 3D Printing and its application in the clinical management of open diaphyseal fractures of the tibia. A pre-experimental and prospective study was made. 14 patients with AO/ASIF tibia fractures 42A, 42B and 42C treated with an external fixator with 3D-printed ball-caps as a Damage Control measure in Orthopedics from admission to final resolution were included. All patients were male, with an average age of 23,16 years, 50% between 20-23 years. The fractures were 42,85% type 42A, 37,71% 42B and 21,42% 42C. 78,57% of the fractures were caused by motorcycles: 57,14% grade II according to Gustilo and Anderson, 28,57% grade III and 14.28% grade I. 37,71% were polytraumatized. None of the patients had complications such as loss of reduction, loosening of the patellas, rupture or fatigue of the patellas, or rod fatigue. 3D printing proved to be a useful tool and alternative in the acute management of open diaphyseal fractures of the tibia(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Fraturas Expostas , Acidentes de Trânsito , Prontuários Médicos , Coleta de Dados
4.
Rev. venez. cir. ortop. traumatol ; 53(1): 27-34, jun. 2021. tab
Artigo em Espanhol | LIVECS, LILACS | ID: biblio-1252908

RESUMO

Las técnicas quirúrgicas mínimamente invasivas ayudan a que el proceso natural de la consolidación ósea ocurra proporcionando estabilidad biomecánica suficiente para obtener los mejores resultados. El objetivo de este trabajo es mostrar los resultados clínicos y radiológicos del tratamiento de las fracturas diafisiarias de tibia con osteosíntesis mínimamente invasiva con placa por cara lateral. Se realizó un estudio clínico observacional, prospectivo, longitudinal y no concurrente. Se incluyeron pacientes mayores de 18 años, de ambos sexos, con diagnósticos de fracturas diafisiarias de tibia 42A, 42B ó 42C, abiertas o cerradas. Se estableció tiempo de seguimiento mínimo de 6 meses. Se incluyeron 23 pacientes, 82,60% de sexo masculino. Promedio de edad de 21±5,63(16­49) años. La fractura más frecuente fue la 42B2 en 26,00% de los casos, y 34,80% fracturas fueron abiertas. A las 12 semanas, 65,10% habían alcanzado consolidación Montoya III; y para la semana 16, 91,30% de los pacientes. De acuerdo a la escala ASAMI, se alcanzaron resultados excelentes en 100,00% pacientes para la semana 16. No se presentaron complicaciones como infección, aflojamiento séptico o aséptico del implante, ni fatiga del mismo. El uso de la técnica MIPO para tratamiento de fracturas diafisiarias de la tibia, por cara lateral es una técnica efectiva y segura, con alta tasas de consolidación, mínimas complicaciones y buenos resultados finales(AU)


Minimally invasive surgical techniques help the natural bone healing process to occur, by providing enough biomechanical stability to obtain the best results. The objective is to show the clinical and radiological results of the treatment of diaphyseal tibial fractures with minimally invasive osteosynthesis with lateral plating. An observational, prospective, longitudinal and non-concurrent clinical study was made. Patients older than 18 years, both sexes, with diagnoses of open or closed tibial shaft fractures 42A, 42B or 42C, were included. A minimum follow-up time of 6 months was established. 23 patients were included, 82,60% male. Average age of 21 years. The most frequent fracture was 42B2 in 26,00% cases, and 34,80% were open fractures. At 12 weeks, 65,10% had reached Montoya III consolidation criterias; and for week 16, 91,30% of the patients. According to the ASAMI scale, excellent results were achieved in 100,00% patients. There were no complications such as infection, septic or aseptic loosening of the implant, or fatigue of the implant. The use of the MIPO technique for the treatment of diaphyseal fractures of the tibia on the lateral aspect is an effective and safe technique, with high rates of union, minimal complications and good final results(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Dispositivos de Fixação Ortopédica , Fraturas da Tíbia/cirurgia , Placas Ósseas , Fixação Interna de Fraturas , Fraturas da Tíbia/classificação , Estudos Prospectivos , Procedimentos Cirúrgicos Minimamente Invasivos
5.
Arch. méd. Camaguey ; 25(2): e7003, mar.-abr. 2021. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1248833

RESUMO

RESUMEN Fundamento: las luxaciones puras del tobillo son lesiones muy infrecuentes, causadas por trauma de alta energía en especial los accidentes del tránsito y caídas de alturas. El tratamiento es por lo general quirúrgico. Objetivo: conocer una paciente con luxación traumática, pura y abierta de la articulación del tobillo. Presentación del caso: paciente de 50 años de edad, mestiza, femenina sin antecedentes mórbidos de salud, la cual sufrió caída de una altura aproximada de tres metros y es traída al cuerpo de guardia del Servicio de Ortopedia y Traumatología por presentar dolor e impotencia funcional total del tobillo derecho. Mediante la exploración física se detectó luxación abierta del tobillo derecho con franca exposición de las superficies articulares de la tibia distal y el astrágalo, además de tendones y partes blandas. Al tener en cuenta todos los elementos anteriores, se decidió llevar la paciente al quirófano, para tratamiento de tipo quirúrgico. De manera inmediata se realizó limpieza, irrigación pulsátil y desbridamiento de la herida en la articulación del tobillo, sutura de las partes blandas dañadas y se colocó fijación externa tipo Hoffman® en configuración de tipo triangular. Conclusiones: el tratamiento por general consiste en la reducción e inmovilización por seis semanas, sin embargo, en caso de afección severa de las partes blandas, donde se necesite la observación y cura de las heridas de forma sistemática, está justificado el uso de la fijación externa como lo es en el caso que se presentó.

6.
Rev Bras Ortop (Sao Paulo) ; 55(6): 771-777, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33364658

RESUMO

Objective To evaluate different femoral fixation devices for medial patellofemoral ligament reconstruction and compare their effectiveness regarding fixation strength up to failure in porcine knees. Methods Thirty porcine knees were used, divided into three groups of 10 knees. The removed grafts were dissected from the extensor tendons of porcine feet. In each group, the graft was fixed to the femur with an interference screw, an anchor, or adductor tenodesis. The three methods were subjected to biomechanical tests using a universal Tensile testing machine at a speed of 20 mm/minute. Results The highest average linear resistance under lateral traction occurred in group 1, "screw fixation" (185.45 ± 41.22 N), followed by group 2, "anchor fixation" (152.97 ± 49, 43 N); the lower average was observed in group 3, "tenodesis fixation" (76.69 ± 18.90 N). According to the fixed error margin (5%), there was a significant difference between groups ( p < 0.001); in addition, multiple comparison tests (between group pairs) also showed significant differences. Variability was small, since the variance coefficient was lower than 33.3%. Conclusion Interference screws in bone tunnels and mountable anchors fixation with high resistance wire are strong enough for femoral fixation in porcine medial patellofemoral ligament reconstruction. Adductor tenodesis, however, was deemed fragile for such purpose.

7.
Rev. Bras. Ortop. (Online) ; 55(6): 771-777, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1156205

RESUMO

Abstract Objective To evaluate different femoral fixation devices for medial patellofemoral ligament reconstruction and compare their effectiveness regarding fixation strength up to failure in porcine knees. Methods Thirty porcine knees were used, divided into three groups of 10 knees. The removed grafts were dissected from the extensor tendons of porcine feet. In each group, the graft was fixed to the femur with an interference screw, an anchor, or adductor tenodesis. The three methods were subjected to biomechanical tests using a universal Tensile testing machine at a speed of 20 mm/minute. Results The highest average linear resistance under lateral traction occurred in group 1, "screw fixation" (185.45 ± 41.22 N), followed by group 2, "anchor fixation" (152.97 ± 49, 43 N); the lower average was observed in group 3, "tenodesis fixation" (76.69 ± 18.90 N). According to the fixed error margin (5%), there was a significant difference between groups (p < 0.001); in addition, multiple comparison tests (between group pairs) also showed significant differences. Variability was small, since the variance coefficient was lower than 33.3%. Conclusion Interference screws in bone tunnels and mountable anchors fixation with high resistance wire are strong enough for femoral fixation in porcine medial patellofemoral ligament reconstruction. Adductor tenodesis, however, was deemed fragile for such purpose.


Resumo Objetivo Avaliar diferentes dispositivos de fixação femoral na reconstrução do ligamento patelofemoral medial para comparar sua eficácia quanto à força de fixação até a falha em joelhos suínos. Métodos Foram ensaiados 30 joelhos de suínos subdivididos em 3 grupos de 10 joelhos. Os enxertos retirados foram dissecados de tendões extensores das patas dos suínos. Cada grupo teve o enxerto fixado ao fêmur com parafuso de interferência, âncora, ou tenodese no tendão adutor. Os 3 métodos foram submetidos à testes biomecânicos utilizando uma máquina universal de ensaio de tração com uma velocidade de 20 mm/min. Resultados Verificamos que a média mais elevada da resistência linear sob tração lateral (185,45 ± 41,22 N) ocorreu no grupo 1: "fixação por parafuso," seguido do grupo 2: "fixação por âncora" (152,97 ± 49,43 N), e a média foi menor no grupo 3: "fixação por tenodese" (76,69 ± 18,90 N). Para a margem de erro fixada (5%), comprovou-se a diferença significativa entre os grupos (p < 0,001) e também através dos testes de comparações múltiplas (entre os pares de grupos) verificou-se a ocorrência de diferenças significativas. A variabilidade expressada por meio do coeficiente de variação mostrou-se reduzida, já que a referida medida foi inferior a 33,3%. Conclusão O uso de parafusos de interferência no túnel ósseo de joelhos porcinos é suficientemente forte para fixação femoral na reconstrução do ligamento patelofemoral medial, assim como a fixação com âncoras montáveis com fio de alta resistência. Entretanto, a tenodese no tendão adutor mostrou-se frágil para essa finalidade.


Assuntos
Animais , Dispositivos de Fixação Ortopédica , Suínos , Tendões , Tração , Efetividade , Fenômenos Biomecânicos , Osso e Ossos , Técnicas de Sutura , Transplantes , Modelos Animais , Tenodese , Articulação Patelofemoral , Fêmur , Ligamentos , Métodos
8.
Acta Ortop Bras ; 28(4): 182-185, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32788860

RESUMO

OBJECTIVE: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. METHODS: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. RESULTS: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. CONCLUSION: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.


OBJETIVO: Comparar desfechos radiográficos pós-operatórios de fraturas do planalto tibial Schatzker V e VI tratados com dupla placa ou placa bloqueada única lateral. MÉTODOS: Foram selecionados 63 pacientes operados no período de dezembro de 2011 a fevereiro de 2016, sendo 47 do grupo dupla placa e 16 do grupo placa bloqueada lateral única. Todos os pacientes tiveram seguimento mínimo de seis meses. A avaliação da redução das fraturas foi baseada nos parâmetros radiográficos: redução articular, alinhamento sagital, alinhamento coronal e largura condilar. RESULTADOS: A avaliação radiográfica não demonstrou diferença estatística no pós-operatório imediato nem no tardio. CONCLUSÃO: Apesar da amostra reduzida, o estudo vai ao encontro dos resultados mais atuais publicados na literatura médica. A gravidade das fraturas do planalto tibial Shatzker V e VI pode ser minimizada com a correta indicação do implante segundo a morfologia da fratura. Nível de Evidência III, Estudo retrospectivo comparativo.

9.
Acta ortop. bras ; Acta ortop. bras;28(4): 182-185, Jul.-Aug. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1130763

RESUMO

ABSTRACT Objective: To compare postoperative radiographic outcomes of Schatzker type V and VI tibial plateau fractures treated with double-plate or single lateral locked plate. Methods: Sixty-three patients operated from December 2011 to February 2016 were selected, 47 from the double-plate group and 16 from the single lateral locked plate group. Minimum follow-up for all patients was 6 months. Fracture reduction evaluation was based on radiographic parameters: joint reduction, sagittal alignment, coronal alignment, and condylar width. Results: Radiographic evaluation showed no statistical difference in the immediate or late postoperative periods. Conclusion: Despite the reduced sample, this study is aligned with current results published in the medical literature. The severity of Schatzker type V and VI tibial plateau fractures can be minimized by the correct indication for the implant regarding fracture morphology. Level of Evidence III, Retrospective comparative study.


RESUMO Objetivo: Comparar desfechos radiográficos pós-operatórios de fraturas do planalto tibial Schatzker V e VI tratados com dupla placa ou placa bloqueada única lateral. Métodos: Foram selecionados 63 pacientes operados no período de dezembro de 2011 a fevereiro de 2016, sendo 47 do grupo dupla placa e 16 do grupo placa bloqueada lateral única. Todos os pacientes tiveram seguimento mínimo de seis meses. A avaliação da redução das fraturas foi baseada nos parâmetros radiográficos: redução articular, alinhamento sagital, alinhamento coronal e largura condilar. Resultados: A avaliação radiográfica não demonstrou diferença estatística no pós-operatório imediato nem no tardio. Conclusão: Apesar da amostra reduzida, o estudo vai ao encontro dos resultados mais atuais publicados na literatura médica. A gravidade das fraturas do planalto tibial Shatzker V e VI pode ser minimizada com a correta indicação do implante segundo a morfologia da fratura. Nível de Evidência III, Estudo retrospectivo comparativo.

10.
Coluna/Columna ; 19(2): 142-147, Apr.-June 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1133559

RESUMO

ABSTRACT Objective In 2003, Mazda et al. introduced a new device for surgical correction of Adolescent Idiopathic Scoliosis (AIS) called sublaminar bands (SB). The reduction principle that SBs use is posteromedial spinal translation, similar to Luque's wiring, but using polyester bands. Methods We performed a systematic review of the literature on this subject, evaluating the technique in terms of coronal correction, sagittal correction, bleeding, mean surgical time, loss of correction, infection, pseudoarthrosis, and neurological and other complications. The total search resulted in 14 articles published over the last 10 years. We found that the use of SBs in hybrid AIS correction instrumentations provides an average correction of 69% in the frontal plane, a 5° increase in thoracic kyphosis (average increase of 55%), overall complications of 4.5%, and no neurological complications were reported in any of the studies analyzed.. The mean blood loss was 682.5 mL and the mean surgical time was 228.6 minutes. Conclusions We conclude that the literature suggests that this instrumentation is safe, allows good correction in the frontal plane and great correction in the sagittal plane. As for complications, mean surgical time, and blood loss, their averages are lower than those of other constructions used for AIS. Level of evidence IIA; Systematic review.


RESUMO Objetivo Em 2003, Mazda et al. apresentaram um novo dispositivo para correção cirúrgica da Escoliose Idiopática do Adolescente (EIA) denominado Bandas Sublaminares (BS). O princípio de redução que as BS utilizam é a translação posteromedial da coluna vertebral, semelhante àquela dos fios de Luque, através do uso de bandas de poliéster. Métodos Realizou-se uma revisão sistemática da literatura sobre o tema, avaliando a técnica em relação à correção coronal, correção sagital, sangramento, tempo operatório médio, perda de correção, infecção, pseudoartrose, complicações neurológicas e outras complicações. A busca resultou em 14 artigos publicados nos últimos 10 anos. Resultados Observamos que o uso das BS em instrumentações híbridas para correção da EIA proporciona uma redução média de 69% no plano frontal e aumento da cifose torácica de 5º (aumento médio de 55%), 4,5% de complicações em geral e nenhuma complicação neurológica foram apresentadas em todos os estudos analisados. A média de sangramento foi 682,5 mL e o tempo cirúrgico médio de 228,6 minutos. Conclusões Conclui-se que a literatura sugere que essa instrumentação é segura, permite boa correção no plano frontal e grande correção no plano sagital. Em relação às complicações, tempo cirúrgico médio e sangramento, todas essas variáveis em média são inferiores se comparadas as das demais construções utilizadas para EIA. Nível de evidência IIA; Revisão sistemática.


RESUMEN Objetivo En 2003, Mazda et al. presentaron un nuevo dispositivo para corrección quirúrgica de la Escoliosis Idiopática del Adolescente (EIA) denominado Bandas Sublaminares (BS). El principio de reducción que las BS utilizan es la traslación posteromedial de la columna vertebral, similar a aquella de los hilos de Luque, a través del uso de bandas de poliéster. Métodos Se realizó una revisión sistemática de la literatura sobre el tema evaluando la técnica con relación a la corrección coronal, corrección sagital, sangrado, tiempo operatorio promedio, pérdida de corrección, infección, pseudoartrosis, complicaciones neurológicas y otras complicaciones. La búsqueda resultó en 14 artículos publicados en los últimos 10 años. Resultados Observamos que el uso de las BS en instrumentaciones híbridas para la corrección de la EIA proporciona una reducción promedio de 69% en el plano frontal y aumento de la cifosis torácica del 5º (aumento promedio de 55%); 4,5% de complicaciones en general y ninguna complicación neurológica fueron presentadas en todos los estudios analizados. El promedio de sangrado fue 682,5 mL y el tiempo quirúrgico promedio de 228,6 minutos. Conclusiones Se concluye que la literatura sugiere que esta instrumentación es segura, permite buena corrección en el plano frontal y gran corrección en el plano sagital. Con relación a las complicaciones, tiempo quirúrgico promedio y sangrado, todas estas variables en promedio son inferiores si comparadas con las demás construcciones usadas para EIA. Nivel de evidencia IIA; Revisión sistemática.


Assuntos
Humanos , Dispositivos de Fixação Ortopédica , Próteses e Implantes , Curvaturas da Coluna Vertebral , Cirurgia Geral
11.
Rev. Bras. Ortop. (Online) ; 53(5): 564-569, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977875

RESUMO

ABSTRACT Objective: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Methods: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. Results: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. Conclusion: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


RESUMO Objetivo: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. Métodos: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. Resultados: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. Conclusão: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.


Assuntos
Animais , Dispositivos de Fixação Ortopédica , Tendões , Tíbia , Fenômenos Biomecânicos , Ligamento Cruzado Anterior
12.
Rev Bras Ortop ; 53(5): 564-569, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30245995

RESUMO

OBJECTIVE: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. METHODS: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. RESULTS: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. CONCLUSION: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


OBJETIVO: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. MÉTODOS: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. RESULTADOS: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. CONCLUSÃO: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.

13.
Arch. méd. Camaguey ; 22(4): 551-563, jul.-ago. 2018. graf
Artigo em Espanhol | LILACS | ID: biblio-950118

RESUMO

RESUMEN Fundamento: los accidentes del tránsito son responsables de un sin número de traumatismos que afectan de manera muy significativa el sistema osteomioarticular, el antebrazo constituye una de las estructuras más involucradas. Objetivo: presentar el caso clínico de un paciente con fractura compleja del antebrazo derecho y la conducta tomada con este enfermo, que logró recuperar en gran medida su capacidad funcional. Caso clínico: paciente de 23 años de edad, blanco, masculino sin antecedentes mórbidos de salud, el cual sufre accidente del tránsito y es traído al servicio de urgencias de Ortopedia y Traumatología por presentar dolor e inflamación a nivel del antebrazo derecho y tobillo izquierdo, que le impedía la marcha y los movimientos de las zonas afectadas. La radiografía simple del antebrazo en proyecciones anteroposterior y lateral mostró solución de continuidad del tejido óseo a nivel de la muñeca, tercio proximal del radio derecho y tobillo izquierdo, basado en estos elementos clínicos e imagenológicos se realizó estabilización y reducción de las fracturas. Conclusiones: la fractura segmentaria del radio, abierta y con pérdida de parte del cúbito es una lesión compleja del antebrazo, donde no existe un patrón estandarizado para la conducta médica. La fijación externa inmediata y la posterior estabilización con placas y tornillos logran obtener resultados satisfactorios.


ABSTRACT Background: road accidents cause many lesions affecting significantly bone and joints system; the forearm is one of the most involved structures. Objective: to show a clinical case of a patient with a complex fracture of the right forearm and the used treatment modality to ensure functional recovery. Clinical case: a 23 years-old, white man, without illness record who suffer a traffic accident and was taken to emergency room of Orthopedics and Traumatology complaining of pain, swelling and limitation of movement of the right forearm and left ankle which stopped him from movement in the affected areas. Simple imaging examination showed wrist and proximal shaft right radial fracture and left ankle fracture, based on clinical and imaging elements, immediate surgical treatment was indicated to reduce and fix fractures. Conclusions: segmental and open fractures of the forearm associated to ulnar bone lost is a complex fracture. There is no a standard treatment for this condition so external fixation and AO plates achieve acceptable functional results.

14.
Acta Ortop Bras ; 26(2): 94-97, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29983624

RESUMO

PURPOSE: To present a technical variation in tibial fixation of quadruple hamstring grafts during anatomic reconstruction of the anterior cruciate ligament (ACL). The secondary purpose was to decrease the costs associated with this procedure. METHODS: Twenty patients who underwent ACL reconstruction were selected. A tibial tunnel was constructed using standard techniques, and a femoral tunnel was anatomically created using the outside-in technique. The hamstring autograft was passed (with its bend) into the tibial tunnel and affixed to the tibia using the suspensory technique and a simple staple. Femoral fixation was performed using a titanium interference screw. The patients underwent postoperative evaluations at 0, 3, 6 and 12 months using the subjective International Knee Documentation Committee (IKDC) form and Lysholm knee scores. RESULTS: The IKDC and Lysholm score results improved over time (p<0.001) without major complications. The cost of the procedure could be reduced by using lower-cost hardware (staples). CONCLUSION: The proposed technique for anatomic ACL reconstruction using inverted hamstring grafts with their bend in the tibial tunnel, suspension-type fixation using a staple demonstrated good to excellent results after 1 year of follow up, with lower aggregate costs. Level of Evidence IV; Case series.


OBJETIVO: Apresentar uma variação técnica na fixação do enxerto quádruplo de tendões flexores à tíbia na reconstrução anatômica do ligamento cruzado anterior (LCA). O objetivo secundário é diminuir o custo associado ao procedimento. MÉTODOS: Foram selecionados 20 pacientes que seriam submetidos à reconstrução do LCA. O túnel tibial foi realizado usando técnica padrão, e o túnel femoral foi realizado pela técnica anatômica de fora para dentro. O enxerto (tendões flexores autólogos) foi passado com sua dobra dentro do túnel tibial e fixado com um agrafe simples pela técnica de suspensão. A fixação femoral foi realizada com parafuso de interferência de titânio. Os pacientes foram avaliados no pré-operatório e aos 3, 6 e 12 meses pós-operatórios usando o questionário International Knee Documentation Committee (IKDC) subjetivo e o questionário de Lysholm. RESULTADOS: Os resultados dos escores dos questionários IKDC e Lysholm tiveram sempre melhora com o tempo (p < 0,001) sem maiores complicações. O custo total da cirurgia foi reduzido usando material de custo menor (agrafe). CONCLUSÃO: A técnica proposta para reconstrução anatômica do LCA com enxerto de tendões flexores invertido com sua dobra no túnel tibial, com fixação tipo suspensão com um agrafe, mostrou bons a excelentes resultados após 1 ano de acompanhamento, com menor custo agregado. Nível de Evidência IV; Série de casos.

15.
Cureus ; 10(3): e2286, 2018 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-29740525

RESUMO

Objective The primary aim of this study was to survey current practices and preferences behind internal fixation of trochanteric femoral fractures among Brazilian orthopedic surgeons. The secondary aim was to identify the main reason for these preferences. Methods A survey containing 20 images of trochanteric fractures of the femur was presented to a group of 62 orthopedists, all members of the Brazilian Society of Orthopedics and Traumatology (SBOT). The first part of the questionnaire was created to identify the surgeons' degree of professional experience, type of practice, and areas of greatest interest and performance within the specialty. The second part of the questionnaire contained options for fixating different trochanteric fracture patterns in the femur for participants to choose, along with the main reason for their decision. Statistical analysis was descriptive and profiled the surgeons' major area of interest, treatment option, and the main reason for their therapeutic decision. Results Of the 62 orthopedists who participated in the study, 10 (16.0%) stated that their area of greatest interest was orthopedic trauma and 52 (83.9%) reported greater interest in another area of the specialty; these two groups were classified as the Trauma Group and Orthopedics Group, respectively. To treat AO 31A1 type fractures, the trauma group selected the sliding hip screw (SHS) in 66.7% of cases, while the orthopedics group chose the SHS in 65.8% of cases. For 31A2 type fractures, the trauma group chose the intramedullary (IM) nail in 64.0% of the cases, while the orthopedics group chose the IM nail in 76.7% of the cases. For 31A3 type fractures, the trauma group opted for the IM nail in 70.0% of the cases, while the orthopedics group selected the IM nail in 88.0% of the cases. The two most important factors in implant selection for the three types of fracture were fracture pattern and implant availability. Conclusion The sliding hip screw is preferred by most Brazilian orthopedic surgeons for fixation of 31A1 type trochanteric femoral fractures. For 31A2 and 31A3 type fractures, the IM nail is preferred.

16.
Acta ortop. bras ; Acta ortop. bras;26(2): 94-97, Mar.-Apr. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-949733

RESUMO

ABSTRACT Purpose: To present a technical variation in tibial fixation of quadruple hamstring grafts during anatomic reconstruction of the anterior cruciate ligament (ACL). The secondary purpose was to decrease the costs associated with this procedure. Methods: Twenty patients who underwent ACL reconstruction were selected. A tibial tunnel was constructed using standard techniques, and a femoral tunnel was anatomically created using the outside-in technique. The hamstring autograft was passed (with its bend) into the tibial tunnel and affixed to the tibia using the suspensory technique and a simple staple. Femoral fixation was performed using a titanium interference screw. The patients underwent postoperative evaluations at 0, 3, 6 and 12 months using the subjective International Knee Documentation Committee (IKDC) form and Lysholm knee scores. Results: The IKDC and Lysholm score results improved over time (p<0.001) without major complications. The cost of the procedure could be reduced by using lower-cost hardware (staples). Conclusion: The proposed technique for anatomic ACL reconstruction using inverted hamstring grafts with their bend in the tibial tunnel, suspension-type fixation using a staple demonstrated good to excellent results after 1 year of follow up, with lower aggregate costs. Level of Evidence IV; Case series.


RESUMO Objetivo: Apresentar uma variação técnica na fixação do enxerto quádruplo de tendões flexores à tíbia na reconstrução anatômica do ligamento cruzado anterior (LCA). O objetivo secundário é diminuir o custo associado ao procedimento. Métodos: Foram selecionados 20 pacientes que seriam submetidos à reconstrução do LCA. O túnel tibial foi realizado usando técnica padrão, e o túnel femoral foi realizado pela técnica anatômica de fora para dentro. O enxerto (tendões flexores autólogos) foi passado com sua dobra dentro do túnel tibial e fixado com um agrafe simples pela técnica de suspensão. A fixação femoral foi realizada com parafuso de interferência de titânio. Os pacientes foram avaliados no pré-operatório e aos 3, 6 e 12 meses pós-operatórios usando o questionário International Knee Documentation Committee (IKDC) subjetivo e o questionário de Lysholm. Resultados: Os resultados dos escores dos questionários IKDC e Lysholm tiveram sempre melhora com o tempo (p < 0,001) sem maiores complicações. O custo total da cirurgia foi reduzido usando material de custo menor (agrafe). Conclusão: A técnica proposta para reconstrução anatômica do LCA com enxerto de tendões flexores invertido com sua dobra no túnel tibial, com fixação tipo suspensão com um agrafe, mostrou bons a excelentes resultados após 1 ano de acompanhamento, com menor custo agregado. Nível de Evidência IV; Série de casos.

17.
Coluna/Columna ; 16(4): 265-269, Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890913

RESUMO

ABSTRACT Objectives: To evaluate the cervical alignment after the correction of idiopathic scoliosis using high screw density and direct vertebral derotation (DVD) and to correlate it with thoracic kyphosis, spinopelvic parameters, and quality of life. Methods: Retrospective cohort study. We assessed the medical records and radiographs of patients submitted to idiopathic scoliosis surgery using high density of pedicular screws (80%) and DVD with at least 6 months of follow-up. All the radiographic parameters were evaluated in the preoperative period and in the last postoperative visit. Results: A total of 43 patients were evaluated, of which 35 (81%) were female. The mean age was 15 years (11 to 30 years) with a mean follow-up of one year and four months. Regarding Lenke's classification, 14 were of group 1, five of group 2, 10 of group 3, eight of group 4, four of group 5 and two of group 6. Only four patients had sagittal modifier (+) and two sagittal modifier (-).There was no significant difference between pre and postoperative thoracic kyphosis. When we evaluated the groups with +, N and - thoracic modifiers, we observed hypokyphotic and normokyphotic patients (- and N) had an increase in kyphosis, whereas hyperkyphotic patients (+)had a decrease. There was no statistical difference in relation to the radiographic parameters of the cervical spine in the pre and postoperative periods. There was a significant improvement in most of the parameters of the quality of life questionnaires, but no correlation with the cervical radiographic parameters. Conclusion: Correction of idiopathic scoliosis using a high density of pedicular screws and a direct vertebral derotation technique failed to improve thoracic kyphosis or change the cervical sagittal alignment, despite promoting a significant improvement in the parameters of quality of life questionnaires.


RESUMO Objetivos: Avaliar o alinhamento cervical após a correção da escoliose idiopática utilizando alta densidade de parafusos e derrotação vertebral direta (DVD) e correlacionar com a cifose torácica, parâmetros espinopélvicos e qualidade de vida. Métodos: Estudo retrospectivo de coorte. Foram avaliados prontuários e radiografias de pacientes submetidos à cirurgia de escoliose idiopática utilizando alta densidade de parafusos pediculares (80%) e DVD com pelo menos seis meses de seguimento. Todos os parâmetros radiográficos foram avaliados no pré-operatório e no último acompanhamento do pós-operatório. Resultados: Foram avaliados 43 pacientes, sendo 35 (81%) do sexo feminino. A média de idade foi 15 anos (11 a 30 anos) com média de seguimento de um ano e quatro meses. Quanto à classificação de Lenke, 14 eram do grupo 1, cinco do grupo 2, 10 do grupo 3, oito do grupo 4, quatro do grupo 5 e dois do grupo 6. Apenas quatro pacientes apresentavam modificador sagital (+) e dois, modificador sagital (-). Não houve diferença significativa entre a cifose torácica pré e pós-operatória. Quando avaliados os grupos com modificadores torácicos +, N e -, constatamos que os pacientes hipocifóticos e normocifóticos (- e N) tiveram aumento da cifose, enquanto os pacientes hipercifóticos (+) tiveram diminuição. Não houve diferença estatística em relação aos parâmetros radiográficos da coluna cervical no pré e pós-operatório. Houve melhora significativa na maioria dos parâmetros dos questionários de qualidade de vida, mas sem nenhuma correlação com os parâmetros radiográficos cervicais. Conclusão: A correção da escoliose idiopática utilizando alta densidade de parafusos pediculares e técnica de derrotação vertebral direta não conseguiu melhorar a cifose torácica ou alterar o alinhamento sagital cervical, apesar de promover melhora significativa dos parâmetros dos questionários de qualidade de vida.


RESUMEN Objetivos: Evaluar la alineación cervical después de la corrección de la escoliosis idiopática utilizando alta densidad de tornillos y desrotación vertebral directa (DVD) y correlacionar con la cifosis torácica, parámetros espinopélvicos y calidad de vida. Métodos: Estudio retrospectivo de cohorte. Se evaluaron los historiales médicos y radiografías de pacientes sometidos a la cirugía de escoliosis idiopática utilizando alta densidad de tornillos pediculares (80%) y DVD con al menos seis meses de seguimiento. Todos los parámetros radiográficos fueron evaluados en el preoperatorio y en el último seguimiento del postoperatorio. Resultados: Se evaluaron 43 pacientes, siendo 35 (81%) del sexo femenino. El promedio de edad fue de 15 años (11 a 30 años) con una media de seguimiento de 1 año y cuatro meses. En cuanto a la clasificación de Lenke, 14 eran del grupo 1, cinco del grupo 2, 10 del grupo 3, ocho del grupo 4, cuatro del grupo 5 y dos del grupo 6. Sólo cuatro pacientes presentaban un modificador sagital (+) y dos, modificador sagital (-). No hubo diferencia significativa entre la cifosis torácica pre y postoperatoria. Cuando se evaluaron los grupos con modificadores torácicos +, N y -, constatamos que los pacientes hipocifóticos y normocifóticos (- y N) tuvieron aumento de la cifosis, mientras que los pacientes hipercifóticos (+) tuvieron disminución. No hubo diferencia estadística en relación a los parámetros radiográficos de la columna cervical en el pre y postoperatorio. Se observó una mejora significativa en la mayoría de los parámetros de cuestionarios de calidad de vida, pero sin ninguna correlación con los parámetros radiográficos cervicales. Conclusión: La corrección de la escoliosis idiopática utilizando alta densidad de tornillos pediculares y técnica de desrotación vertebral directa no logró mejorar la cifosis torácica o alterar la alineación sagital cervical, a pesar de promover una mejora significativa de los parámetros de los cuestionarios de calidad de vida.


Assuntos
Humanos , Escoliose/cirurgia , Dispositivos de Fixação Ortopédica , Resultado do Tratamento , Parafusos Pediculares
18.
Acta ortop. bras ; Acta ortop. bras;24(5): 262-266, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-797874

RESUMO

ABSTRACT Objective: Based on a literature review and on our own experience, this study proposes sheep as an experimental model to evaluate the bioactive capacity of bone substitute biomaterials, dental implant systems and orthopedics devices. The literature review covered relevant databases available on the Internet from 1990 until to date, and was supplemented by our own experience. Methods: For its resemblance in size and weight to humans, sheep are quite suitable for use as an experimental model. However, information about their utility as an experimental model is limited. The different stages involving sheep experiments were discussed, including the care during breeding and maintenance of the animals obtaining specimens for laboratory processing, and highlighting the unnecessary euthanasia of animals at the end of study, in accordance to the guidelines of the 3Rs Program. Results: All experiments have been completed without any complications regarding the animals and allowed us to evaluate hypotheses and explain their mechanisms. Conclusion: The sheep is an excellent animal model for evaluation of biomaterial for bone regeneration and dental implant osseointegration. From an ethical point of view, one sheep allows for up to 12 implants per animal, permitting to keep them alive at the end of the experiments. Level of Evidence II, Retrospective Study.

19.
Coluna/Columna ; 15(1): 22-25, Jan.-Mar. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-779075

RESUMO

ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°). The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°). There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.


RESUMO Objetivos: Comparar os resultados de tratamento cirúrgico com fixação lombar usando hastes de nitinol sem artrodese e com fixação lombar padrão com hastes de titânio e fusão intersomática. Métodos: Foram analisados os resultados do tratamento em 70 pacientes com escoliose lombar degenerativa com idades entre 40 e 82 anos. Em todos os casos, foram usados parafusos pediculares e hastes de nitinol com diâmetro de 5,5 mm. Trinta pacientes foram submetidos à fixação em L1-S1 e 40 pacientes tiveram fixação em L1-L5. Não foi realizada artrodese da coluna. Todos os pacientes fizeram radiografias, TC e RM. Os resultados foram avaliados de acordo com a escala de Oswestry, com o SRS 22, o SF 36 e EVA. O período mínimo de acompanhamento para todos os pacientes foi de 2,5 anos. No grupo controle, com 72 pacientes, realizou-se a fixação do pedículo com hastes de titânio e fusão intersomática na região lombossacral. Resultados: O nível médio de correção da deformidade correspondeu a 25° (10°-38°). A análise das radiografias e das TC revelou um único paciente com instabilidade, dois pacientes com reabsorção óssea ao redor dos parafusos e um paciente apresentou fraturas da haste. A radiografia funcional 2,5 anos após a cirurgia mostrou mobilidade média da coluna lombar de 21° (15°-30°). Não foram encontrados problemas nos níveis adjacentes. Conclusões: O uso de hastes de nitinol na cirurgia de deformidades da coluna é promissor. Essa tecnologia é uma alternativa à fixação rígida. É preciso manter a coleta continuada de dados clínicos e sua posterior avaliação.


RESUMEN Objetivos: Comparar los resultados de tratamiento quirúrgico con fijación lumbar usando varillas de nitinol sin artrodesis y con fijación lumbar estándar con varillas de titanio y fusión intersomática. Métodos: Fueron analizados los resultados del tratamiento en 70 pacientes con escoliosis lumbar degenerativa con edades entre 40 y 82 años. En todos los casos, fueron usados tornillos pediculares y varillas de nitinol con diámetro de 5,5 mm. Treinta pacientes fueron sometidos a fijación en L1-S1 y 40 pacientes tuvieron fijación en L1-L5. No fue realizada artrodesis de la columna. Todos los pacientes hicieron radiografías, TC y RM. Los resultados fueron evaluados de acuerdo con la escala de Oswestry, con SRS 22, SF 36 y EVA. El período mínimo de acompañamiento para todos los pacientes fue de 2,5 años. En el grupo control, con 72 pacientes, se realizó la fijación del pedículo con varillas de titanio y fusión intersomática en la región lumbosacra. Resultados: El nivel medio de corrección de la deformidad correspondió a 25° (10°-38°). El análisis de las radiografías y de las TC reveló un único paciente con inestabilidad, dos pacientes con reabsorción ósea alrededor de los tornillos y un paciente presentó fracturas de la varilla. La radiografía funcional 2,5 años después de la cirugía mostró movilidad media de la columna lumbar de 21° (15°-30°). No fueron encontrados problemas en los niveles adyacentes. Conclusiones: El uso de varillas de nitinol en la cirugía de deformidades de la columna es promisor. Esa tecnología es una alternativa para la fijación rígida. Es preciso mantener la colecta continuada de datos clínicos y su posterior evaluación.


Assuntos
Humanos , Escoliose/cirurgia , Dispositivos de Fixação Ortopédica , Fixadores Internos , Parafusos Pediculares
20.
Acta Ortop Bras ; 24(5): 262-266, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28149193

RESUMO

OBJECTIVE: Based on a literature review and on our own experience, this study proposes sheep as an experimental model to evaluate the bioactive capacity of bone substitute biomaterials, dental implant systems and orthopedics devices. The literature review covered relevant databases available on the Internet from 1990 until to date, and was supplemented by our own experience. METHODS: For its resemblance in size and weight to humans, sheep are quite suitable for use as an experimental model. However, information about their utility as an experimental model is limited. The different stages involving sheep experiments were discussed, including the care during breeding and maintenance of the animals obtaining specimens for laboratory processing, and highlighting the unnecessary euthanasia of animals at the end of study, in accordance to the guidelines of the 3Rs Program. RESULTS: All experiments have been completed without any complications regarding the animals and allowed us to evaluate hypotheses and explain their mechanisms. CONCLUSION: The sheep is an excellent animal model for evaluation of biomaterial for bone regeneration and dental implant osseointegration. From an ethical point of view, one sheep allows for up to 12 implants per animal, permitting to keep them alive at the end of the experiments. Level of Evidence II, Retrospective Study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA