Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Contact Dermatitis ; 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-39367763

RESUMO

BACKGROUND: Propolis types differ regarding their chemical composition. OBJECTIVES: To compare patch test results based on Brazilian (Green) propolis with data based on Chinese (poplar-type) propolis, and to evaluate the specifications of raw materials used for the PT preparations. METHODS: In the Information Network of Departments of Dermatology (IVDK), 1290 consecutive patients were patch tested with Brazilian (Green) propolis (NH400, SmartPractice Europe). Patch test reactivity was compared with results obtained with Chinese (poplar-type) propolis (NA71, SmartPractice Europe) by calculating frequencies and corresponding 95% confidence intervals. Data on the specifications of raw materials used for NH400 and NA71 were obtained from the manufacturer. RESULTS: Positive reactions to NH400 were found in 303 (23.5%) patients with unclear clinical relevance in most cases. Patients reacting to NH400 were less often sensitised to fragrances and colophony, but more often to nickel sulphate and cobalt chloride than patients reacting to NA71. The NH400 batch used contained high levels of aerobic bacteria, and was not purified by ethanolic extraction. CONCLUSIONS: Pattern of concomitant reactivity along with raw material properties suggests that the high frequency of positive reactions to NH400 may primarily result from bacterial contamination or impurities in the PT preparation rather than from propolis constituents.

2.
Anal Bioanal Chem ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39126504

RESUMO

Water, renowned for its sustainability and minimal toxicity, is an ideal candidate for environmentally friendly solvent-based microextraction. However, its potential as an extractant solvent in miniaturized sample preparation remains largely unexplored. This paper pioneers using water as the extraction solvent in headspace single-drop microextraction (HS-SDME) for N-nitrosamines from losartan tablets. Autonomous HS-SDME is executed by an Arduino-controlled, lab-made Cartesian robot, using water for the online preconcentration of enriched extracts through direct injection into a column-switching system. Critical experimental parameters influencing HS-SDME performance are systematically explored through univariate and multivariate experiments. While most previously reported methods for determining N-nitrosamines in pharmaceutical formulations rely on highly selective mass spectrometry detection techniques to handle the strong matrix effects typical of pharmaceutical samples, the water-based HS-SDME method efficiently eliminates the interfering effects of a large amount of the pharmaceutical active ingredient and tablet excipients, allowing straightforward analysis using high-performance liquid chromatography with ultraviolet detection (HPLC-UV-Vis). Under optimized conditions, the developed method exhibits linear responses from 100 to 2400 ng g-1, demonstrating appropriate detectability, precision, and accuracy for the proposed application. Additionally, the environmental sustainability of the method is assessed using the AGREEprep methodology, positioning it as an outstanding green alternative for determining hazardous contaminants in pharmaceutical products.

3.
Polymers (Basel) ; 16(14)2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-39065396

RESUMO

In this study, the impact of ethylene oxide, propylene oxide, 1,2-butene oxide, and 1,2-pentene oxide on the polymerization of propylene at an industrial level was investigated, focusing on their influence on the catalytic efficiency and the properties of polypropylene (PP) without additives. The results show that concentrations between 0 and 1.24 ppm of these epoxides negatively affect the reaction's productivity, the PP's mechanical properties, the polymer's fluidity index, and the PP's thermal properties. Fourier transform infrared spectroscopy (FTIR) revealed bands for the Ti-O bond and the Cl-Ti-O-CH2 bonds at 430 to 475 cm-1 and 957 to 1037 cm-1, respectively, indicating the interaction between the epoxides and the Ziegler-Natta catalyst. The thermal degradation of PP in the presence of these epoxides showed a similar trend, varying in magnitude depending on the concentration of the inhibitor. Sample M7, with 0.021 ppm propylene oxide, exhibited significant mass loss at both 540 °C and 600 °C, suggesting that even small concentrations of this epoxide can markedly increase the thermal degradation of PP. This pattern is repeated in samples with 1,2-butene oxide and 1,2-pentene oxide. These results highlight the need to strictly control the presence of impurities in PP production to optimize both the final product's quality and the polymerization process's efficiency.

4.
Crit Rev Anal Chem ; : 1-21, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058576

RESUMO

The presence of impurities in active pharmaceutical ingredients (APIs) and drug products represents a risk to patients' health. Such substances are related to diverse side effects and may have mutagenic potential. That's why it is necessary to establish acceptable limits for these by-products, to minimize the risk associated with medicinal therapy. This work focused on presenting a critical review of relevant points related to the presence of impurities in pharmaceuticals. The main legislation and guidelines from the FDA, EMA, ICH, and Pharmacopeias about the subject were evaluated, and recent articles related to the topic were searched in Scopus, ScienceDirect, PubMed, and Web of Science from 2013 to 2023. Additionally, the analytical techniques used for quantifying impurities were discussed, along with relevant tests for assessing the toxicological and mutagenic risks of these by-products. Recent legislation, including ICH Q3A (R2), ICH Q3B (R2), ICH M7 (R2), ICH Q3D (R2), ICH Q3C (R9), ICH Q3E, ICH Q6A, ICH M3 (R2), as well as FDA and EMA guidelines, highlights a comprehensive and effective framework for controlling impurities in pharmaceuticals. Despite this, there remains a lack of harmonization and standardized procedures across different regions. From the review of scientific literature, we observed that advancements in analytical techniques have significantly improved the sensitivity and selectivity in detecting impurities and degradation products. This underscores the ongoing commitment of health agencies and the pharmaceutical industry to ensure the safety and efficacy of medicinal products.

5.
Regul Toxicol Pharmacol ; 151: 105669, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38936796

RESUMO

Potentially mutagenic impurities are likely to be formed in any drug substance, since their synthesis requires reactive intermediates which may also react with DNA. The ICH M7 guideline, which defines how to risk assess and control mutagenic impurities, was first published in 2014 and is not to be applied retrospectively; however, some impurities have been found above the permitted limits in drug products which were already on the market. This study assessed the implications of applying ICH M7 retrospectively to anti-hypertensive drugs marketed in Brazil by performing a risk assessment and establishing control strategies. The manufacturing processes of 15 drug substances were evaluated and 262 impurities were identified, from which 21% were classified as potentially mutagenic. Most of the impurities were identified below ICH M7 acceptable limits, except for impurities described in a pharmacopoeial monograph. Compendial specifications are defined based on scientific evidence and play an important role in setting quality and safety standards for pharmaceuticals, however there are opportunities for further alignment with ICH guidelines, aiming for a holistic assessment of the impurities profile to ensure the safety of medicines.


Assuntos
Anti-Hipertensivos , Contaminação de Medicamentos , Mutagênicos , Brasil , Medição de Risco , Anti-Hipertensivos/toxicidade , Mutagênicos/toxicidade , Mutagênicos/análise , Estudos Retrospectivos , Humanos , Guias como Assunto
6.
J Sep Sci ; 46(17): e2300214, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37400419

RESUMO

The development of a fast, cost-effective, and efficient microextraction by packed sorbent setup was achieved by combining affordable laboratory-repackable devices of microextraction with a high-throughput cartesian robot. This setup was evaluated for the development of an analytical method to determine N-nitrosamines in losartan tablets. N-nitrosamines pose a significant concern in the pharmaceutical market due to their carcinogenic risk, necessitating their control and quantification in pharmaceutical products. The parameters influencing the performance of this sample preparation for N-nitrosamines were investigated through both univariate and multivariate experiments. Microextractions were performed using just 5.0 mg of carboxylic acid-modified polystyrene divinylbenzene copolymer as the extraction phase. Under the optimized conditions, the automated setup enabled the simultaneous treatment of six samples in less than 20 min, providing reliable analytical confidence for the proposed application. The analytical performance of the automated high-throughput microextraction by the packed sorbent method was evaluated using a matrix-matching calibration. Quantification was performed using ultra-high-performance liquid chromatography-tandem mass spectrometry with chemical ionization at atmospheric pressure. The method exhibited limits of detection as low as 50 ng/g, good linearity, and satisfactory intra-day (1.38-18.76) and inter-day (2.66-20.08) precision. Additionally, the method showed accuracy ranging from 80% to 136% for these impurities in pharmaceutical formulations.


Assuntos
Nitrosaminas , Robótica , Nitrosaminas/análise , Losartan/análise , Espectrometria de Massas em Tandem/métodos , Limite de Detecção , Microextração em Fase Sólida/métodos , Cromatografia Líquida , Cromatografia Líquida de Alta Pressão/métodos , Comprimidos
7.
MethodsX ; 10: 101952, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36636282

RESUMO

Caprolactam is a highly useful monomer obtained through the Beckmann arrangement, which generates large profits worldwide and is widely used in different industries. During the synthesis process, various components can be generated that weaken the quality of the final product, to have control of the monomer, monitoring is carried out during the synthesis and characterization of the final product. These characterizations generally take time due to the different techniques that must be performed to obtain the data. In this work, a method is designed that associates different techniques to reduce the number of steps carried out in the tests to determine the quality of the material, optimize the times and generate a quality and efficient process in a shorter time, in addition, it is due to a semi-automated system for the simultaneous characterization of caprolactam, which, according to the statistical data obtained for sodium, iron, volatile bases, and moisture analysis were reproducible. The developed prototype had 21 on-line valves that allowed taking the representative volumes of samples and reagents necessary for each measurement. There is excellent linearity where the correlation coefficient has values between 0,9992 and 1. The values obtained for the relative error are between 0.18 and 2.24% for laboratory tests using the traditional method and between 0.21 and 3.83% for tests carried out using the prototype. The P value of the evaluation of the means was 0.997, indicating that the means are not statistically different.•Caprolactam analysis•Process optimization•Determination of impurities.

8.
J Pharm Sci ; 112(5): 1305-1314, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36657719

RESUMO

N-nitrosamines (NA) impurities have unexpectedly been found in sartan products, angiotensin II receptor antagonists that are used to control hypertension, representing an urgent concern for industry, global regulators and for the patients. In this study, an HPLC-MS/MS method was developed and validated for the quantification of six NA (N-nitrosodimethylamine, N-Nitroso-N-methyl-4-aminobutyric acid, N-Nitrosodiethylamine, N-ethyl-N-nitroso-2-propanamine, N-nitroso-diisopropylamine and N-nitroso-di-n-butylamine) in losartan, valsartan, olmesartan, irbesartan, candesartan and telmisartan products. The method was validated in terms of sensitivity, linearity, accuracy, precision, robustness and stability. The limits of quantification were 100, 31.25, 250, 33, 312.5 and 125 µg kg-1 in losartan, valsartan, olmesartan, irbesartan, candesartan and telmisartan samples, respectively, which met the sensitivity requirements for the limits set by Food and Drug Administration of the United States. The standard curves showed good linearity. The recoveries ranged from 93.06 to 102.23% in losartan matrix, 83 to 85.9% in valsartan, 96.1 to 101.2% in olmesartan, 89.2 to 97.5% in irbesartan, 93.4 to 132.0% in candesartan and 62.3 to 106.2% in telmisartan matrix. The other parameters met the validation criteria, the good sensitivity and precision, high accuracy and simple and fast analysis provides a reliable method for quality control of NA in sartan pharmaceutical products. The developed method was successfully applied for the determination of N-nitrosamines in 71 sartan products marketed in Brazil.


Assuntos
Nitrosaminas , Humanos , Nitrosaminas/análise , Bloqueadores do Receptor Tipo 1 de Angiotensina II , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem/métodos , Losartan , Carcinógenos/análise , Irbesartana/análise , Preparações Farmacêuticas , Telmisartan , Brasil , Valsartana/análise , Valsartana/química
9.
Artigo em Inglês | MEDLINE | ID: mdl-36498066

RESUMO

An ultra-fast method for the simultaneous determination of heavy metals in Passiflora incarnata tea by capillary electrophoresis (CE) using a short-end injection combined with multivariate analysis was proposed. Separation was conducted by hydrodynamic injection (5 s at 0.5 psi) using the short-end injection procedure in a fused uncoated silica capillary (50 cm total length, 10.2 cm effective length, 50 µm i.d.) with separation time less than 2 min. An indirect UV detection at 214 nm was employed by using imidazole as a chromophore. The buffer used was 6 mmol/L hydroxybutyric acid (HIBA). The optimum conditions by full factorial with a central point were achieved by 18-crown-6 concentration (23.3 mmol L−1), voltage (+11.4 kV), methanol concentration (3.8%), and temperature (20 °C). The method showed good linearity (R2 > 0.998) for both Cd and Pb, inter-day precision of less than 14.49%, and an adequate limit of quantification only for Cd (LOQ < 0.5 µg mL−1 for Cd) based on the US Pharmacopeial Convention limit requirements for elemental impurities. After method validation, the method was applied to Passiflora incarnata tea samples from a local market. Furthermore, the developed method showed great potential for the determination of metals in other samples with proper sample preparation procedures.


Assuntos
Passiflora , Cádmio , Eletroforese Capilar/métodos , Análise Multivariada
10.
Sci Total Environ ; 833: 155068, 2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-35413346

RESUMO

We have investigated the source and role of light-absorbing impurities (LAIs) deposited on the glaciers of the Olivares catchment, in Central Chile. LAIs can considerably darken (lowered albedo) the glacier surface, enhancing their melt. We combined chemical and mineralogical laboratory analyses of surface and ice core samples with field-based spectral reflectance measurements to investigate the nature and properties of such LAIs. Using remote sensing-based albedo maps, we upscaled local information to glacier-wide coverage. We then used a model to evaluate the sensitivity of surface mass balance to a change in ice and snow albedo. The across-scale surface observations in combination with ice core analysis revealed a history of over half a century of LAIs deposition. We found traces of mining residuals in glacier surface samples. The glaciers with highest mass loss in the catchment present enhanced concentrations of surface dust particles with low reflectance properties. Our results indicate that dust particles with strong light-absorbing capacity have been mobilized from mine tailings and deposited on the nearby glacier surfaces. Large-scale assessment from satellite-based observations revealed darkening (ice albedo lowering) at most investigated glacier tongues from 1989 to 2018. Glacier melt is sensitive to ice albedo. We believe that an accelerated winter and spring snow albedo decrease, partially triggered by surface impurities, might be responsible for the above-average mass loss encountered in this catchment.


Assuntos
Camada de Gelo , Neve , Chile , Poeira/análise , Camada de Gelo/química , Estações do Ano , Neve/química
11.
Crit Rev Anal Chem ; 52(5): 1078-1093, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33347374

RESUMO

Ezetimibe (EZM) is a selective inhibitor of the sterol transporter Niemann-Pick C1-Like 1 in the small intestine used as an adjunctive therapy to lower cholesterol levels in cases of hyperlipidemia. The goal of this work was to summarize the main physical-chemical, pharmacological and pharmacokinetic characteristics of EZM, as well as to describe the main analytical methodologies for the quantification of the drug. Methods described in the United States Pharmacopeia for EZM raw material and tablets were also presented. The drug has a large number of process-related impurities and degradation products and needs strict quality control of its impurities. Specific chiral methods for the evaluation of its chiral impurities are also a need for EZM. The main advantages and disadvantages of the compiled analytical methods were presented, as well as the limits of detection and quantitation. The fastest and most efficient methods were highlighted. Most methods for analyzing EZM used C8 or C18 stationary phases in gradient mode with binary mobile phases containing acetonitrile and an acidic buffer solution with ultraviolet detection. For analysis of EZM in biological matrices, liquid chromatography-tandem mass spectrometry is generally employed using electron spray ionization in negative ionization mode using multiple reaction monitoring. Different methods in the literature evaluate a large number of impurities for EZM, however new stability-indicating high-performance liquid chromatography methods for the drug are still needed.


Assuntos
Ezetimiba , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Composição de Medicamentos , Ezetimiba/análise , Ezetimiba/química , Comprimidos
12.
Crit Rev Anal Chem ; 52(8): 1846-1862, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34024199

RESUMO

Lopinavir/ritonavir is a potent coformulation of protease inhibitors used against HIV infection. Lopinavir is the main responsible for viral load suppression, whereas ritonavir is a pharmacokinetic enhancer. Both of them have recently gained relevance as candidate drugs against severe coronavirus disease (COVID-19). However, significant beneficial effects were not observed in randomized clinical trials. This review summarizes the main physical-chemical, pharmacodynamic, and pharmacokinetic properties of ritonavir and lopinavir, along with the analytical methodologies applied for biological matrices, pharmaceutical formulations, and stability studies. The work also aimed to provide a comprehensive impurity profile for the combined formulation. Several analytical methods in four different pharmacopeias and 37 articles in literature were evaluated and summarized. Chromatographic methods for these drugs frequently use C8 or C18 stationary phases with acetonitrile and phosphate buffer (with ultraviolet detection) or acetate buffer (with tandem mass spectrometry detection) as the mobile phase. Official compendia methods show disadvantages as extended total run time and complex mobile phases. HPLC tandem-mass spectrometry provided high sensitivity in methodologies applied for human plasma and serum samples, supporting the therapeutic drug monitoring in HIV patients. Ritonavir and lopinavir major degradation products arise in alkaline and acidic environments, respectively. Other non-chromatographic methods were also summarized. Establishing the impurity profile for the combined formulation is challenging due to a large number of impurities reported. Easier and faster analytical methods for impurity assessment are still needed.


Assuntos
Tratamento Farmacológico da COVID-19 , Infecções por HIV , Inibidores da Protease de HIV , Humanos , Lopinavir/farmacocinética , Lopinavir/uso terapêutico , Ritonavir/efeitos adversos , Infecções por HIV/tratamento farmacológico , Infecções por HIV/induzido quimicamente , Inibidores da Protease de HIV/efeitos adversos , Composição de Medicamentos
13.
Rev. colomb. ciencias quim. farm ; 49(2): 509-522, May-Aug. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1144364

RESUMO

SUMMARY This study aimed to develop and validate a stability-indicating liquid chromatography method for the determination of tirofiban hydrochloride and two synthetic impurities (impurity A and impurity C). The method utilizes a RP-18 column (250 mm x 4.6 mm; 5 µm) with the PDA detector for quantitation. A mixture of triethylamine 0.1% (acidified to pH 5.5 with phosphoric acid) and acetonitrile was used as the mobile phase at a flow rate of 1 mL min-1 with gradient elution. The method presented satisfactory linearity, precision, accuracy and robustness, as well as low limits of detection and quantification, which demonstrate sensitivity in the determination of tirofiban and impurities A and C. It was selective for the determination of the drug and impurities analysed, without interference of the degradation products generated under forced conditions, demonstrating the stability-indicating capacity of the proposed method. Tirofiban showed to be practically stable to oxidative (30% H2O2 for 24 h) and thermal (75 °C for 24 h) conditions, but presented degradation to UVA light and acid hydrolysis, obeying the first order kinetics for both. In this way, it can be used as a stability-indicating method in the quality control of the raw material of tirofiban hydrochloride, as well as of the finished product. The obtained results demonstrate the importance of deepening the studies in this area, to guarantee the quality of commercialized pharmaceutical products.


RESUMO Este estudo teve como objetivo desenvolver e validar método indicativo da estabilidade por cromatografía líquida para determinação de cloridrato de tirofibana e duas impurezas de síntese (impureza A e impureza C). O método utilizou coluna de fase reversa RP-18 (250 mm x 4,6 mm; 5 µm) e detector PDA para quantificação. A fase móvel foi composta por uma mistura de trietilamina 0,1% (acidificada com ácido fosfórico para pH 5,5) e acetonitrila, à vazão de 1 mL/min, no modo gradiente. O método apresentou linearidade, precisão, exatidão, robustez, bem como baixos limites de detecção e quantificação, demonstrando sensibilidade na determinação da tirofibana e impurezas A e C. O método apresentou seletividade na determinação do fármaco e das impurezas, sem interferência dos produtos de degradação gerados na degradação forçada da tirofibana, demonstrando sua capacidade indicativa de estabilidade. O fármaco apresentou-se estável a oxidação (H2O2 30% por 24 h) e a degradação térmica (75 °C por 24 h), mas degradou frente à luz UVA e hidrolise ácida, obedecendo cinética de primeira ordem para ambas. Dessa forma, pode ser utilizado como um método indicativo de estabilidade no controle de qualidade da matéria -prima do cloridrato de tirofibana, bem como no produto acabado. Os resultados obtidos demonstram a importância de aprofundar os estudos na área, com intuito de garantir a qualidade dos produtos farmacêuticos comercializados.

14.
Anal Chim Acta ; 1098: 1-26, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31948571

RESUMO

The daily use of cosmetics may expose consumers to localized skin problems and systemic effects caused by absorption of chemical elements. The requirements for suitable quality control and maximum limits for toxic and potentially toxic elements in cosmetics have attracted the attention of the scientific community and of the official institutions around the world. Maximum limits for chemical elements in some cosmetics have been set, but there are disagreements between them. In the same context, many analytical methods have been proposed in the literature, but several challenges during the sample preparation and determination steps related to the high complexity of cosmetics' matrices composition still remain. It is extremely difficulty to establish suitable methods, free of interference, even using modern technology. In this review, methods for determining toxic and potentially toxic elements in cosmetics used for make-up on the lips and on the eye area, covering the period since 2000, are presented. Techniques enabling direct analysis and those requiring a sample preparation step prior to the analysis are also discussed. This review focused on cosmetics for make-up on the lips and on the eye area because the risks of percutaneous absorption and oral ingestion of toxic and potentially toxic elements is higher than in other body regions.


Assuntos
Cosméticos/efeitos adversos , Cosméticos/análise , Cosméticos/toxicidade , Humanos
15.
Braz. J. Pharm. Sci. (Online) ; 56: e18162, 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1089199

RESUMO

Resumo Amiodarone hydrochloride is one of the most important drugs used to treat arrhythmias. The USP monograph for amiodarone hydrochloride describes an HPLC method for the quantification of seven impurities, however, this method shows problems that result in unresolved peaks. Moreover, there is no monograph for tablets in this compendium. Thus, a stability indicating HPLC method was developed for the determination of amiodarone, its known impurities and degradation products in tablets. A detailed forced degradation study was performed submitting amiodarone API, tablets and placebo to different stress conditions: acid and alkaline hydrolysis, oxidation, metal ions, heat, humidity, and light. Amiodarone hydrochloride API was susceptible to degradation in all stress conditions. The tablets also showed degradation in all environments, except in acidic condition. The analytes separation and quantification were achieved on an Agilent Zorbax Eclipse XDB-C18 column (100 x 3.0 mm, 3.5 µm). The mobile phase was composed of 50 mM acetate buffer pH 5.5 (A) and a mixture of methanol-acetonitrile (3:4, v/v) (B) in gradient elution. The method was validated in the range of 350-650 µg/mL for assay and 10-24 µg/mL for impurities determination. Therefore, this method can be used both for stability studies and routine quality control analyses.

16.
BMC Pharmacol Toxicol ; 20(Suppl 1): 82, 2019 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-31852534

RESUMO

BACKGROUND: The presence of impurities in some drugs may compromise the safety and efficacy of the patient's treatment. Therefore, establishing of the biological safety of the impurities is essential. Diabetic patients are predisposed to tissue damage due to an increased oxidative stress process; and drug impurities may contribute to these toxic effects. In this context, the aim of this work was to study the toxicity, in 3 T3 cells, of the antidiabetic agents sitagliptin, vildagliptin, and their two main impurities of synthesis (S1 and S2; V1 and V2, respectively). METHODS: MTT reduction and neutral red uptake assays were performed in cytotoxicity tests. In addition, DNA damage (measured by comet assay), intracellular free radicals (by DCF), NO production, and mitochondrial membrane potential (ΔψM) were evaluated. RESULTS: Cytotoxicity was observed for impurity V2. Free radicals generation was found at 1000 µM of sitagliptin and 10 µM of both vildagliptin impurities (V1 and V2). A decrease in NO production was observed for all vildagliptin concentrations. No alterations were observed in ΔψM or DNA damage at the tested concentrations. CONCLUSIONS: This study demonstrated that the presence of impurities might increase the cytotoxicity and oxidative stress of the pharmaceutical formulations at the concentrations studied.


Assuntos
Composição de Medicamentos/normas , Contaminação de Medicamentos , Fibroblastos/efeitos dos fármacos , Hipoglicemiantes/toxicidade , Fosfato de Sitagliptina/toxicidade , Vildagliptina/toxicidade , Células 3T3 , Animais , Sobrevivência Celular/efeitos dos fármacos , Dano ao DNA , Fibroblastos/metabolismo , Fibroblastos/patologia , Hipoglicemiantes/química , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Camundongos , Óxido Nítrico/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Fosfato de Sitagliptina/química , Vildagliptina/química
17.
Talanta ; 197: 20-27, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771924

RESUMO

New guidelines for the limits of elemental impurities in drug products were introduced by the International Council for Harmonization in 2014. While the guidelines define a limit for each element, the complete quantification of the 24 elements included is, in fact, unnecessary. An accurate "pass/fail" test to determine whether the threshold was exceeded or not could be valuable in this context. In this study, a screening procedure using the features of high-resolution continuum source graphite furnace atomic absorption spectrometry for the evaluation of 12 elements in three different drugs was developed. The three-dimensional absorbance spectrum including time and wavelength in the vicinity of the main line of the element allows for a pass/fail decision related to the presence or absence of the element in the sample. Additionally, the bi-dimensional absorbance-wavelength spectrum defines the elements captured in the window when additional peaks are seen in the spectrum. The analysis of the selected drugs included sample digestion, the definition of pyrolysis and atomization temperatures, determination of the limit of detection and other validation parameters for each element. The evaluation of the spectra, both three- and bi-dimensional, revealed that only three elements, Cr, Ni, and Cu, were present in the samples in amounts above the LOD and therefore "fail" in the test. Nevertheless, they were quantified, and the analysis revealed that their levels were below the permitted daily exposure, which are at least 6 times higher than the LOD of the selected elements. Operating in a routine mode, the proposed method is a good option for the evaluation of elemental impurities in drug active ingredients or drug final products.


Assuntos
Grafite/química , Losartan/química , Metais Pesados/análise , Omeprazol/química , Sinvastatina/química , Espectrofotometria Atômica
18.
J Pept Sci ; 24(6): e3081, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29676523

RESUMO

CIGB-300 is a first-in-class synthetic peptide-based drug of 25 amino acids currently undergoing clinical trials in cancer patients. It contains an amidated disulfide cyclic undecapeptide fused to the TAT cell-penetrating peptide through a beta-alanine spacer. CIGB-300 inhibits the CK2-mediated phosphorylation leading to apoptosis of tumor cells in vitro, and in vivo in cancer patients. Despite the clinical development of CIGB-300, the characterization of peptide-related impurities present in the active pharmaceutical ingredient has not been reported earlier. In the decision tree of ICHQ3A(R2) guidelines, the daily doses intake, the abundance, and the identity of the peptide-related species are pivotal nodes that define actions to be taken (reporting, identification, and qualification). For this, purity was first assessed by reverse-phase chromatography (>97%) and low-abundance impurities (≤0.27%) were collected and identified by mass spectrometry. Most of the impurities were generated during peptide synthesis, the spontaneous air oxidation of the reduced peptide, and the lyophilization step. The most abundant impurity, with no biological activity, was the full-length peptide containing Met17 transformed into a sulfoxide residue. Interestingly, parallel and antiparallel dimers of CIGB-300 linked by 2 intermolecular disulfide bonds exhibited a higher antiproliferative activity than the CIGB-300 monomer. Likewise, very low abundance trimers and tetramers of CIGB-300 linked by disulfide bonds (≤0.01%) were also detected. Here we describe for the first time the presence of active dimeric species whose feasibility as novel CIGB-300 derived entities merits further investigation.


Assuntos
Antineoplásicos/farmacologia , Peptídeos Penetradores de Células/farmacologia , Peptídeos Cíclicos/farmacologia , Peptídeos/farmacologia , Antineoplásicos/síntese química , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Peptídeos Penetradores de Células/síntese química , Técnicas de Química Sintética/métodos , Humanos , Neoplasias/tratamento farmacológico , Peptídeos/síntese química , Peptídeos Cíclicos/síntese química , Fosforilação/efeitos dos fármacos
19.
Biomed Chromatogr ; 32(7): e4222, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29488235

RESUMO

Imatinib mesylate (IM) is an anti-neoplasic drug used for the treatment of cancer. Recent new guidelines specify daily doses and concentration limits for genotoxic impurities (GTIs) in pharmaceutical final products. Therefore, in this work an analytical method using UHPLC-MS/MS was developed, validated and applied to characterize IM tablets for two GTIs: N-(2-methyl-5-aminophenyl)-4-(3-pyridyl)-2-pyrimidine amine (Imp. 1), and N-[4-methyl-3-(4-methyl-3-yl-pyrimidin-2-ylamino)-phenyl]-4- chloromethyl benzamide (Imp. 2), simultaneously. Additionally, dissolution data of IM tablets were compared using a methodology recommended by the US Food and Drug Administration. The UHPLC method utilized an Acquity BEH C18 (150 × 2.1 mm, 1.7 µm) maintained at 40°C. The mobile phase consisted of ammonium formate 0.063% (phase A) and acetonitrile plus 0.05% formic acid (phase B) in gradient elution. A sensitive method for determination of previously mentioned GTIs in IM tablets was successfully developed and applied. Overall, the formulations analyzed in this work showed low levels of Imp. 1 and Imp. 2. However, the sample named D1 showed very high levels of Imp. 1 and failed to meet the requirements established by the US Food and Drug Administration for dissolution data. Periodic verification of GTIs in pharmaceutical formulations is important to minimize safety risks, so analytical methods to determine it need be available and implemented in routine analysis.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Medicamentos , Mesilato de Imatinib/análise , Mesilato de Imatinib/normas , Mutagênicos/análise , Espectrometria de Massas em Tandem/métodos , Mesilato de Imatinib/química , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Solubilidade , América do Sul , Comprimidos
20.
J Photochem Photobiol B ; 181: 157-163, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29571070

RESUMO

Folic acid, or pteroyl­l­glutamic acid (PteGlu) is a conjugated pterin derivative that is used in dietary supplementation as a source of folates, a group of compounds essential for a variety of physiological functions in humans. Photochemistry of PteGlu is important because folates are not synthesized by mammals, undergo photodegradation and their deficiency is related to many diseases. We have demonstrated that usual commercial PteGlu is unpurified with the unconjugated oxidized pterins 6­formylpterin (Fop) and 6­carboxypterin (Cap). These compounds are in such low amounts that a normal chromatographic control would not detect any pterinic contamination. However, the fluorescence of PteGlu solutions is due to the emission of Fop and Cap and the contribution of the PteGlu emission, much lower, is negligible. This is because the fluorescence quantum yield (ΦF) of PteGlu is extremely weak compared to the ΦF of Fop and Cap. Likewise, the PteGlu photodegradation upon UV-A radiation is an oxidation photosensitized by oxidized unconjugated pterins present in the solution, and not a process initiated by the direct absorption of photons by PteGlu. In brief, the fluorescence and photochemical properties of PteGlu solutions, prepared using commercially available solids, are due to their unconjugated pterins impurities and not to PteGlu itself. This fact calls into question many reported studies on fluorescence and photooxidation of this compound.


Assuntos
Ácido Fólico/química , Pterinas/química , Cromatografia Líquida de Alta Pressão , Ácido Fólico/análise , Espectrometria de Massas , Oxirredução , Fotólise/efeitos da radiação , Pterinas/análise , Espectrometria de Fluorescência , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA