Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 271
Filtrar
1.
Phys Med Biol ; 69(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39008980

RESUMO

Objective.Accurate simulation of human tissues is imperative for advancements in diagnostic imaging, particularly in the fields of dosimetry and image quality evaluation. Developing Tissue Equivalent Materials (TEMs) with radiological characteristics akin to those of human tissues is essential for ensuring the reliability and relevance of imaging studies. This study presents the development of a mathematical model and a new toolkit (TEMPy) for obtaining the best composition of materials that mimic the radiological characteristics of human tissues. The model and the toolkit are described, along with an example showcasing its application to obtain desired TEMs.Approach.The methodology consisted of fitting volume fractions of the components of TEM in order to determine its linear attenuation coefficient as close as possible to the linear attenuation coefficient of the reference material. The fitting procedure adopted a modified Least Square Method including a weight function. This function reflects the contribution of the x-ray spectra in the suitable energy range of interest. TEMPy can also be used to estimate the effective atomic number and electron density of the resulting TEM.Main results.TEMPy was used to obtain the chemical composition of materials equivalent to water and soft tissue, in the energy range used in x-ray imaging (10 -150 keV) and for breast tissue using the energy range (5-40 keV). The maximum relative difference between the linear attenuation coefficients of the developed and reference materials was ±5% in the considered energy ranges.Significance.TEMPy facilitates the formulation of TEMs with radiological properties closely mimicking those of real tissues, aiding in the preparation of physical anthropomorphic or geometric phantoms for various applications. The toolkit is freely available to interested readers.


Assuntos
Imagens de Fantasmas , Humanos , Mama/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Modelos Biológicos , Feminino
2.
Med Phys ; 51(9): 6423-6431, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38851217

RESUMO

BACKGROUND: Although standard operational procedures for pre-therapeutic dosimetry already exist for the determination of the maximum safe activity to treat differentiated thyroid cancer patients, empiric activity administration of 131I is still the most frequent way of treatment. In this way, the absorbed dose to the blood/bone marrow remains unknown. PURPOSE: In this work, we present a strategy to estimate radiation dose to the blood in an outpatient setting. METHODS: A mobile application was developed, which together with an off-the-shelf compact semiconductor radiation detector allows the determination of whole-body time-integrated activity coefficients. The methodology was tested in a cohort of 79 differentiated cancer patients who received therapeutic 131I activities. Post-therapeutic whole-body time-integrated activity coefficients were compared against pre-therapeutic estimates in a subset of 13 patients. RESULTS: The 95% limits of agreement between pre whole-body and post whole-body time integrated activity coefficients were [-14.4; 6.6] h when considering outliers and [-6.2; 3.6] h without outliers. A high dispersion in blood dose coefficients was found, with a four-fold difference between the highest and lower values. Blood doses were significantly higher for patients treated with dosimetrically guided activities than for empirical activities (median dose = 118 vs. 49 cGy, respectively). Blood dose coefficients were significantly lower for patients prepared with recombinant human thyroid stimulating hormone (rhTSH) than for patients prepared with thyroid hormone withdrawal. A low correlation between blood dose and administered activity was found in empirically treated patients (R2 = 0.26). CONCLUSIONS: We successfully implemented a post-therapeutic internal dosimetry methodology for differentiated thyroid cancer therapy with 131I, which allows to estimate dose to the blood from outpatient measurements with mobile devices. The proposed methodology avoids the need of daily visits to the nuclear medicine department, thus reducing the burden for the patient and for the staff.


Assuntos
Radioisótopos do Iodo , Pacientes Ambulatoriais , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/sangue , Doses de Radiação , Masculino , Radiometria , Feminino , Pessoa de Meia-Idade , Adulto , Aplicativos Móveis , Dosagem Radioterapêutica , Idoso
3.
J Med Phys ; 49(1): 1-5, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828064

RESUMO

Purpose: To calculate the contribution of absorbed dose by organs in the biokinetics of Tc-99m when used for radiodiagnosis of the adult male heart employing a Matlab program. Methods: The absorbed self-dose of the adult male heart and absorbed dose by organs in the biokinetics of the heart when administering Tc-99m are estimated using the MIRD formalism and the Cristy-Eckerman representation, which have been employed to develop the algorithm in Matlab. Results: The results indicate that electron capture emissions of 1.446 (mGy/MBq) and Auger electrons of 0.062 (mGy/MBq) are entirely directed towards the target organ (heart) and contribute 29.33% and 1.25% respectively to its total dose. Additionally, the dosimetric contributions of biokinetic organs correspond to characteristic radiation emissions and gamma photons at 2.578 (mGy/MBq) for Tc-99m, representing 52.29% of its total dose. Conclusion: These dosimetric contributions are significant in estimating the total absorbed dose by the heart in adult males and should not be disregarded.

4.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535344

RESUMO

Purpose: To describe the acoustic characteristics of a classroom, voice quality, fatigue, and vocal load of university professors. Methods: Exploratory, observational, longitudinal, and descriptive study with a single group of participants, including vocal monitoring data over two weeks. Acoustic characterization of the classroom, perceptual-auditory evaluation, and acoustic analysis of voice samples were conducted before and after classes. Vocal dosimetry was performed during classes, and the Vocal Fatigue Index (VFI) was assessed at the beginning of each week. Descriptive analysis of the findings was conducted, and randomization test was performed to verify the internal reliability of the judge. Results: All participants reported speaking loudly in the classroom, with the majority reporting vocal changes in the past six months, and only one participant reported a current vocal change. The classroom had acoustical measures and estimations that deviated from established standards. The professors used high vocal intensities during classes. After the classes, an increase in the absolute values of the aggregated data for CAPE-V, jitter, and fundamental frequency was found, varying within the range of normality. Furthermore, there was an observed increase in both post-lesson intensity and VFI when comparing the two-week period. Conclusions: Vocal intensities and VFI were possibly impacted by the acoustics of the classroom. The increase in average VFI between the weeks may be attributed to a cumulative fatigue sensation. Further research with a larger number of participants and in acoustically conditioned classrooms is suggested in order to evaluate collective intervention proposals aimed at reducing the vocal load on teachers.


Objetivo: Describir las características acústicas, calidad vocal, fatiga y carga vocal de profesores universitarios. Métodos: Estudio exploratorio, observacional, longitudinal, descriptivo con un solo grupo de participantes y datos de monitoreo vocal durante dos semanas. Se realizó caracterización acústica de la sala, evaluación auditiva-perceptiva y acústica de muestras de voz antes y después de las clases. Se realizó dosimetría vocal durante las clases y se verificó el Índice de Fatiga Vocal (IFV) en dos semanas. Se realizó un análisis descriptivo de los hallazgos y una prueba de aleatorización para verificar la confiabilidad interna del juez. Resultados: Todos los participantes informaron hablar en voz alta en clase, la mayoría informó cambios vocales en los últimos seis meses y solo uno informó cambios vocales actuales. La sala presentó mediciones y estimaciones acústicas fuera de las normas establecidas. Los profesores utilizaron intensidades vocales altas durante las clases. Hubo un aumento en los valores absolutos de los datos agrupados para CAPE-V, jitter y frecuencia fundamental, variando dentro de los límites normales, después de las clases. La intensidad después de las clases y el IFV, en la comparación entre las dos semanas, mostraron un aumento. Conclusiones: La dosis vocal y el IFV posiblemente se vieron afectados por la acústica del aula. El aumento del IFV medio entre semanas pudo deberse a la sensación de cansancio acumulada. Se sugieren nuevas investigaciones con un mayor número de participantes y que se realicen en la sala acondicionada acústicamente para evaluar propuestas de intervención colectiva, con el objetivo de reducir la carga vocal de los docentes.

5.
J Radiol Prot ; 44(2)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38722296

RESUMO

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.


Assuntos
Exposição Ocupacional , Doses de Radiação , Humanos , Exposição Ocupacional/análise , Criança , Cateterismo Cardíaco , Proteção Radiológica , Cristalino/efeitos da radiação , Radiografia Intervencionista , Exposição à Radiação/análise
6.
Int J Radiat Biol ; 100(7): 1029-1040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38787719

RESUMO

PURPOSE: To analyze the effects of extending lymphocyte cultivation time on the Mitotic Index, frequency of first-division cells, and dose estimation after irradiating blood samples with different doses of radiation. MATERIALS AND METHODS: Blood samples from two healthy male volunteers were separately irradiated with three doses (3, 5, and 6 Gy) using a 60Co gamma source (average dose rate: 1.48 kGy.h-1) and cultivated in vitro for conventional (48 h) and extended (56, 68, and 72 h) amounts of time. Colcemid (0.01 µg.mL-1) was added at the beginning of the culture period. Cells were fixed, stained with fluorescence plus Giemsa (FPG), and analyzed under a light microscope. The effects of prolonged culture duration on the Mitotic Index (MI), frequency of first-division cells (M1 cells), and the First-Division Mitotic Index (FDMI) were investigated. The estimation of delivered doses was conducted using a conventional 48h-culture calibration curve. RESULTS: Overall, cells presented higher MI (up to 12-fold) with the extension of culture, while higher radiation doses led to lower MI values (up to 80% reduction at 48 h). Cells irradiated with higher doses (5 and 6 Gy) had the most significant increase (5- to 12-fold) of MI as the cultivation was prolonged. The frequency of M1 cells decreased with the prolongation of culture for all doses (up to 75% reduction), while irradiated cells presented higher frequencies of M1 cells than non-irradiated ones. FDMI increased for all irradiated cultures but most markedly in those irradiated with higher doses (up to 10-fold). The conventional 48h-culture calibration curve proved adequate for assessing the delivered dose based on dicentric frequency following a 72-hour culture. CONCLUSION: Compared to the conventional 48-hour protocol, extending the culture length to 72 hours significantly increased the Mitotic Index and the number of first-division metaphases of irradiated lymphocytes, providing slides with a better scorable metaphase density. Extending the culture time to 72 hours, combined with FPG staining to score exclusively first-division metaphases, improved the counting of dicentric chromosomes. The methodology presented and discussed in this study can be a powerful tool for dicentric-based biodosimetry, especially when exposure to high radiation doses is involved.


Assuntos
Relação Dose-Resposta à Radiação , Linfócitos , Índice Mitótico , Radiometria , Humanos , Masculino , Linfócitos/efeitos da radiação , Linfócitos/citologia , Análise Citogenética , Adulto , Fatores de Tempo , Doses de Radiação , Células Cultivadas , Técnicas de Cultura de Células/métodos
7.
Luminescence ; 39(4): e4732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38556715

RESUMO

In the present work, glass samples in the (100 - x)B2O3-xLi2O binary system, with x varying from 30 to 50 mol%, were prepared using the conventional melting and moulding method, with the main objective of evaluating the thermoluminescence response when exposing these materials to ultraviolet (UV) radiation. Complementary analysis based on density, optical absorption on the UV-visible region (UV-vis absorbance), Fourier transform infrared spectroscopy on the medium region, X-ray diffraction, and differential thermal analysis measurements were performed. Thermoluminescence measurements of vitreous samples showed glow curves with at least one peak with a maximum temperature of ~170°C after exposure to UV radiation in the temperature range 50-250°C. Samples were also exposed to beta radiation in the temperature range 25-275°C, also showing single peaks with a maximum temperature of ~150°C.


Assuntos
Partículas beta , Boratos , Boratos/química , Compostos de Lítio , Temperatura
8.
Biomed Phys Eng Express ; 10(3)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38631317

RESUMO

Introduction. The currently available dosimetry techniques in computed tomography can be inaccurate which overestimate the absorbed dose. Therefore, we aimed to provide an automated and fast methodology to more accurately calculate the SSDE usingDwobtained by using CNN from thorax and abdominal CT study images.Methods. The SSDE was determined from the 200 records files. For that purpose, patients' size was measured in two ways: (a) by developing an algorithm following the AAPM Report No. 204 methodology; and (b) using a CNN according to AAPM Report No. 220.Results. The patient's size measured by the in-house software in the region of thorax and abdomen was 27.63 ± 3.23 cm and 28.66 ± 3.37 cm, while CNN was 18.90 ± 2.6 cm and 21.77 ± 2.45 cm. The SSDE in thorax according to 204 and 220 reports were 17.26 ± 2.81 mGy and 23.70 ± 2.96 mGy for women and 17.08 ± 2.09 mGy and 23.47 ± 2.34 mGy for men. In abdomen was 18.54 ± 2.25 mGy and 23.40 ± 1.88 mGy in women and 18.37 ± 2.31 mGy and 23.84 ± 2.36 mGy in men.Conclusions. Implementing CNN-based automated methodologies can contribute to fast and accurate dose calculations, thereby improving patient-specific radiation safety in clinical practice.


Assuntos
Algoritmos , Doses de Radiação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Masculino , Feminino , Tamanho Corporal , Redes Neurais de Computação , Software , Automação , Tórax/diagnóstico por imagem , Adulto , Abdome/diagnóstico por imagem , Radiometria/métodos , Radiografia Torácica/métodos , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Radiografia Abdominal/métodos , Idoso
9.
Med Phys ; 51(7): 5094-5098, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38507246

RESUMO

BACKGROUND: Non-melanoma skin cancer is one of the most common types of cancer and one of the main approaches is brachytherapy. For small lesions, the treatment of this cancer with brachytherapy can be done with two commercial applicators, one of these is the Large Field Valencia Applicators (LFVA). PURPOSE: The aim of this study is to test the capabilities of the LFVA to use clinically 60Co sources instead of the 192Ir ones. This study was designed for the same dwell positions and weights for both sources. METHODS: The Penelope Monte Carlo code was used to evaluate dose distribution in a water phantom when a 60Co source is considered. The LFVA design and the optimized dwell weights reported for the case of 192Ir are maintained with the only exception of the dwell weight of the central position, that was increased. 2D dose distributions, field flatness, symmetry and the leakage dose distribution around the applicator were calculated. RESULTS: When comparing the dose distributions of both sources, field flatness and symmetry remain unchanged. The only evident difference is an increase of the penumbra regions for all depths when using the 60Co source. Regarding leakage, the maximum dose within the air volume surrounding the applicator is in the order of 20% of the prescription dose for the 60Co source, but it decreases to less than 5% at about 1 cm distance. CONCLUSIONS: Flatness and symmetry remains unaltered as compared with 192Ir sources, while an increase in leakage has been observed. This proves the feasibility of using the LFVA in a larger range of clinical applications.


Assuntos
Braquiterapia , Radioisótopos de Cobalto , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica , Braquiterapia/instrumentação , Radioisótopos de Cobalto/uso terapêutico , Radiometria/instrumentação , Imagens de Fantasmas , Radioisótopos de Irídio/uso terapêutico , Humanos
10.
Heliyon ; 10(3): e25025, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38318030

RESUMO

Topaz (Al2F1·44(OH)0·56SiO4)/corundum (Al2O3) composites were prepared by a facile and novel reversible process from the sintering of synthetic topaz and AlF3 powders, with corundum formed in situ into the topaz matrix. The corundum formation reaction occurs in the temperature range 875-975 °C, from 40 min sintering time, obtaining the topaz- Al2F1·44(OH)0·56SiO4/corundum- Al2O3 composites. Although sintering temperature and time increment lead to higher corundum formation in the topaz matrix (78.4 wt % Al2O3 at 975 °C for 60 min), longer residence times give place to corundum percentage decrease due to topaz reconversion. The composites' microstructure is characterized by a rectangular bar with stacked pyramidal ends and polycrystals of hexagonal plates for topaz and corundum, respectively. For the topaz/corundum composites, the maximum density was 3.05 g/cm3 (17 % porosity) for specimens sintered at 925 °C for 20 min. The glow curves of the topaz/in situ corundum composite sintered at 975 °C and 0 min dwell time show thermoluminescent peaks between 180 and 250 °C, useful for dosimetric applications. The most helpful peak (at 221 °C) in the topaz/corundum composite's glow curves determined by computational deconvolution is sharp and exhibits the highest thermoluminescent response. Dose-response analysis of the composite (sintered at 975 °C for 0 min) with the best thermoluminescent response revealed two ranges of linear behavior, the first from 2 to 200 mGy, with an adjustment of 99.9 % and the second in the range 5-300 Gy (99.8 % fitting). The thermoluminescent response improvement of the topaz/corundum composites is attributed to the corundum formed in situ during sintering. Fading rate studies of the composite with the best sintering treatment revealed a signal decrease of 4 % after 15 days, which remained constant for up to 30 days, and 8 % after 60 days. The kinetic parameters, kinetics order (b), activation energy (E), and frequency factor (s) determined using the glow peak shape method showed second-order kinetics. The topaz/corundum composite with the best TL response (975 °C, 0 min) presents an effective atomic number (Zeff) of 11.74. The detection of lower doses (mGy) and the linear response at higher doses (Gy) of beta 90Sr, together with the other thermoluminescent properties, suggest that the topaz/corundum composites sintered at 975° for 0 min dwell time may find application in radiotherapy, geological dating, and environmental dosimetry.

11.
Appl Radiat Isot ; 206: 111189, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309119

RESUMO

Since the end of the Brazilian state monopoly in 2006, allowing private enterprises to act in producing and commercializing short half-life radiopharmaceuticals, the country observed a growth in the laboratories that use 18F-FDG to PET/CT exams. Considering the radiological protection and safety techniques applied to radioisotope-producing facilities or units, this study assembled the current situation of radiological protection showing the received doses of the professionals of four facilities with cyclotrons for 18F-FDG located in south and southeast Brazil in the years 2020 and 2021. The dose values observed are below the dose limits established by national and international regulatory entities but can still be optimized considering differences between the production units.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Brasil , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Ciclotrons , Compostos Radiofarmacêuticos
12.
Appl Radiat Isot ; 205: 111158, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38159450

RESUMO

The risk of lung cancer or pneumoconiosis mortality, increases with radioactive radon gas exposures. This article report health risk for underground workers exposed to radioactive gas and radon daughters carried by airborne dust at the coal mining in the Central Mountainous Region of Colombia. A set of 33 measurement points located in that mine galleries were selected to monitor radon gas concentration activity, by passive LR-115 detectors, during two months. Resulting values provided radon concentrations, absorbed dose, environmental equivalent dose and the effective dose; miners increased risk of contracting lung cancer is included. It is concluded that the mine ventilation system satisfies the conditions required by the current radiological protection of the miners. Our study point out that Colombia can effectively address the potential risks associated with radon exposure and ensure a safer living environment for its citizens.


Assuntos
Neoplasias Pulmonares , Exposição Ocupacional , Radônio , Humanos , Radônio/efeitos adversos , Radônio/análise , Neoplasias Pulmonares/etiologia , Colômbia , Produtos de Decaimento de Radônio/análise , Carvão Mineral/efeitos adversos , Exposição Ocupacional/efeitos adversos
13.
Med Phys ; 51(2): 1117-1126, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38146824

RESUMO

BACKGROUND: Although the benefits of breast screening and early diagnosis are known for reducing breast cancer mortality rates, the effects and risks of low radiation doses to the cells in the breast are still ongoing topics of study. PURPOSE: To study specific energy distributions ( f ( z , D g ) $f(z,D_{g})$ ) in cytoplasm and nuclei of cells corresponding to glandular tissue for different x-ray breast imaging modalities. METHODS: A cubic lattice (500 µm length side) containing 4064 spherical cells was irradiated with photons loaded from phase space files with varying glandular voxel doses ( D g $D_{g}$ ). Specific energy distributions were scored for nucleus and cytoplasm compartments using the PENELOPE (v. 2018) + penEasy (v. 2020) Monte Carlo (MC) code. The phase space files, generated in part I of this work, were obtained from MC simulations in a voxelized anthropomorphic phantom corresponding to glandular voxels for different breast imaging modalities, including digital mammography (DM), digital breast tomosynthesis (DBT), contrast enhanced digital mammography (CEDM) and breast CT (BCT). RESULTS: In general, the average specific energy in nuclei is higher than the respective glandular dose scored in the same region, by up to 10%. The specific energy distributions for nucleus and cytoplasm are directly related to the magnitude of the glandular dose in the voxel ( D g $D_{g}$ ), with little dependence on the spatial location. For similar D g $D_{g}$ values, f ( z , D g ) $f(z,D_{g})$ for nuclei is different between DM/DBT and CEDM/BCT, indicating that distinct x-ray spectra play significant roles in f ( z , D g ) $f(z,D_{g})$ . In addition, this behavior is also present when the specific energy distribution ( F g ( z ) $F_{g}(z)$ ) is considered taking into account the GDD in the breast. CONCLUSIONS: Microdosimetry studies are complementary to the traditional macroscopic breast dosimetry based on the mean glandular dose (MGD). For the same MGD, the specific energy distribution in glandular tissue varies between breast imaging modalities, indicating that this effect could be considered for studying the risks of exposing the breast to ionizing radiation.


Assuntos
Mamografia , Radiometria , Raios X , Método de Monte Carlo , Radiometria/métodos , Mamografia/métodos , Imagens de Fantasmas , Doses de Radiação
14.
Med Phys ; 51(2): 1105-1116, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38156766

RESUMO

BACKGROUND: X-ray breast imaging modalities are commonly employed for breast cancer detection, from screening programs to diagnosis. Thus, dosimetry studies are important for quality control and risk estimation since ionizing radiation is used. PURPOSE: To perform multiscale dosimetry assessments for different breast imaging modalities and for a variety of breast sizes and compositions. The first part of our study is focused on macroscopic scales (down to millimeters). METHODS: Nine anthropomorphic breast phantoms with a voxel resolution of 0.5 mm were computationally generated using the BreastPhantom software, representing three breast sizes with three distinct values of volume glandular fraction (VGF) for each size. Four breast imaging modalities were studied: digital mammography (DM), contrast-enhanced digital mammography (CEDM), digital breast tomosynthesis (DBT) and dedicated breast computed tomography (BCT). Additionally, the impact of tissue elemental compositions from two databases were compared. Monte Carlo (MC) simulations were performed with the MC-GPU code to obtain the 3D glandular dose distribution (GDD) for each case considered with the mean glandular dose (MGD) fixed at 4 mGy (to facilitate comparisons). RESULTS: The GDD within the breast is more uniform for CEDM and BCT compared to DM and DBT. For large breasts and high VGF, the ratio between the minimum/maximum glandular dose to MGD is 0.12/4.02 for DM and 0.46/1.77 for BCT; the corresponding results for a small breast and low VGF are 0.35/1.98 (DM) and 0.63/1.42 (BCT). The elemental compositions of skin, adipose and glandular tissue have a considerable impact on the MGD, with variations up to 30% compared to the baseline. The inclusion of tissues other than glandular and adipose within the breast has a minor impact on MGD, with differences below 2%. Variations in the final compressed breast thickness alter the shape of the GDD, with a higher compression resulting in a more uniform GDD. CONCLUSIONS: For a constant MGD, the GDD varies with imaging modality and breast compression. Elemental tissue compositions are an important factor for obtaining MGD values, being a source of systematic uncertainties in MC simulations and, consequently, in breast dosimetry.


Assuntos
Mamografia , Radiometria , Raios X , Método de Monte Carlo , Radiometria/métodos , Mamografia/métodos , Imagens de Fantasmas , Doses de Radiação
15.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535327

RESUMO

Objectives: This was a single-subject study, aimed to demonstrate different vocal demand situations that are typical for primary school and teacher's vocal demand response under two acoustical conditions, with and without voice amplification, during five working days. Methods: The long-term voice dosimetry with Vocal Holter Med (PR.O. Voice Srl) was carried out on a 49-year-old female teacher with voice disorders during daily teaching activities. A sound field amplification system (SFAS) PentaClass Runa was installed in the classroom. Voice dosimetry was provided under two different acoustical conditions: without SFAS (2 days) and with SFAS (3 days). Results: Phonation time percentage, sound pressure level (SPL), SPL SD, fundamental frequency (F0), F0 SD, cycle, and distance doses were investigated in seven communication scenarios (lessons, group/individual classes, sports lessons in the gym and schoolyard, breaks, lunch breaks, and other activities). The median scores of all voice parameters differed significantly between different vocal demand contexts. The significant statistical difference in the vocal demand response was in the communication situations with and without SFAS. In addition, the number of children, reverberation time, and ambient air relative humidity impacted voice SPL and the cycle dose. Conclusions: Lessons, sports lessons held in the gym or schoolyard, breaks, and lunch breaks were considered as high vocal demand communication situations requiring higher voice intensity and fundamental frequency, higher phonation time percentage, cycle, and distance doses. Group/individual work and other teacher activities during the day, unrelated to direct work with students, were categorized as low vocal demand communication scenarios.


Objetivos: Este fue un estudio de sujeto único, cuyo objetivo fue demostrar diferentes situaciones de demanda vocal típicas de la escuela primaria y la respuesta vocal de los docentes bajo dos condiciones acústicas, con y sin amplificación de voz, durante cinco días laborables. Métodos: Se llevó a cabo dosimetría vocal a largo plazo con Vocal Holter Med (PR.O. Voice Srl) durante las actividades diarias de enseñanza en una docente de 49 años con trastornos de la voz. Se instaló un sistema de amplificación de campo sonoro (SFAS) PentaClass Runa en el aula. La dosimetría vocal se realizó bajo dos condiciones acústicas diferentes: sin SFAS (2 días) y con SFAS (3 días). Resultados: Se investigaron el porcentaje de tiempo de fonación, el nivel de presión sonora (SPL), SPL SD, la frecuencia fundamental (F0), F0 SD, ciclos y dosis de distancia en siete escenarios de comunicación diferentes (clases, clases grupales/individuales, clases de educación física en el gimnasio y el patio de la escuela, recreos, almuerzos y otras actividades). Las puntuaciones medias de todos los parámetros vocales diferían significativamente entre los diferentes contextos de demanda vocal. La diferencia estadísticamente significativa en la respuesta a la demanda vocal se observó en las situaciones de comunicación con y sin SFAS. Además, el número de niños, el tiempo de reverberación y la humedad relativa del aire ambiente afectaron al SPL de la voz y la dosis de ciclo. Conclusiones: Las lecciones, las clases de educación física en el gimnasio o el patio de la escuela, los recreos y los almuerzos se consideraron situaciones de comunicación de alta demanda vocal, que requerían una mayor intensidad y frecuencia fundamental de la voz, un mayor porcentaje de tiempo de fonación y dosis de ciclo y distancia más altas. El trabajo grupal/individual y otras actividades del profesor durante el día no relacionadas con el trabajo directo con los estudiantes se categorizaron como escenarios de comunicación de baja demanda vocal.

16.
Clin Oral Investig ; 27(12): 7881-7888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37993703

RESUMO

OBJECTIVE: To compare the dosimetry between convex triangular fields of view (FOV) and similar dimension cylindrical FOVs of two cone-beam computed tomography (CBCT) models. METHODS: Optically stimulated luminescence dosimeters (OSLDs) were placed in fiducial anatomical locations in an anthropomorphic phantom representing an adult head male for dosimetry scans. Convex triangular FOVs (100 × 80 mm/maxilla-mandible; 100 × 50 mm mandible; 100 × 50 mm/maxilla) from Veraviewepocs 3D R100 (J. Morita, Kyoto, Japan) (R100) and Veraview® X800 (J. Morita, Kyoto, Japan) (X800) and cylindrical FOVs from R100 and X800 (80 × 80 mm/maxilla-mandible; 80 × 50 mm/mandible; 80 × 50 mm/maxilla) were obtained, resulting in 12 different scan protocols. Equivalent doses for each relevant organ/tissue and the effective dose for each protocol were calculated. Mean effective doses were compared by the two-way analysis of variance (ANOVA) with Tukey's post hoc test to evaluate the effect of the FOV and device (α = 0.05). RESULTS: The effective doses ranged between 69 and 324 µSv for the convex triangular FOVs and 76 and 332 µSv for the cylindrical FOVs. Convex triangular FOVs from the R100 device had effective doses 2.3 to 15.3% lower than their corresponding cylindrical FOVs with similar height (p < 0.05), and that difference ranged between 8.8 and 11.8% for the X800 device (p < 0.05). CONCLUSION: Convex triangular fields of view delivered slightly lower effective doses than the cylindrical fields of view of similar dimensions in the R100 and X800 CBCT devices. CLINICAL RELEVANCE: Understanding the influence of the image geometry formation in effective dose allows optimization to reduce patient dose.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiometria , Adulto , Masculino , Humanos , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem , Maxila , Imagens de Fantasmas
17.
Phys Med Biol ; 68(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37852274

RESUMO

Metallic nanoparticles, such as gold (Au, Z = 79) and silver (Ag, Z = 47) nanoparticles (AuNPs and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high atomic number, which makes them ideal candidates for enhancing dosimeter sensitivity. In this study, we have inserted different mass percentages (from 0 to 0.015 wt%) of AuNPs into a gelatinous Fricke-xylenol-orange (FXO-f) gel matrix and irradiated it with doses ranging from 2 to 32 Gy, using a source of x-ray of low energy with an effective energy of 42 keV. Optical absorption increased significantly; sensitivity gains of up to 50% were achieved for the FXO-f gel matrix containing 0.011 wt% AuNPs. To elucidate the mechanism underlying this increased sensitivity, we also evaluated FXO-f gel matrixes containing AgNPs. AgNPs insertion into the FXO-f gel matrix did not enhance sensitivity, which suggested that the AgNPs plasmonic absorption band and the FXO-f gel matrix absorption band at 441 nm overlapped, to increase absorption even after the gel matrix was irradiated. To visualize the dose distribution, we recorded optical tomography and acquired 3D reconstruction maps. In addition, we analyzed the dose enhancement factor (DEF) by using magnetic resonance images. AuNPs insertion into the FXO-f gel matrix resulted in a DEF gain of 1.37, associated with the photoelectric effect originating from the increased number of free radicals.


Assuntos
Ouro , Nanopartículas Metálicas , Radiometria/métodos , Imageamento por Ressonância Magnética
18.
Heliyon ; 9(9): e19509, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37681134

RESUMO

Purpose: Optimization studies in digital radiology help to reduce the radiological risk to patients and maximize the benefits associated with their clinical purpose. The aim of this study was to assess the optimization of lateral lumbar spine projection via a combination of exposure parameters adjustments and additional filtration using a sectional anthropomorphic phantom. Materials and methods: We evaluated the effects of peak voltage, tube loading, and low-cost filters made of copper, titanium, brass, and nickel on both the perceived and physical quality of 125 radiographs obtained in a computer radiography system. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) with their Figure of Merit (FOM), based on the entrance surface air kerma with backscatter (ESAK), was used to assess physical image quality. Results: The standard image had a perceived image quality, SNR, FOMSNR, CNR, FOMCNR and ESAK of 3.4, 22.3, 386.4, 23.6, 433.7 and 1.28 mGy, respectively. Copper (90.3% purity) and titanium (95.0% purity) filters reduced ESAK by an average of 60% without compromising diagnostic quality, while brass and nickel filters increased dose under the conditions of the study. Conclusions: Our findings show that optimizing lumbar spine projection can reduce radiation dose without compromising image quality. Low-cost copper and titanium filters can be valuable in resource-limited settings. Further research can explore additional strategies for radiological optimization.

19.
Radiol Bras ; 56(3): 137-144, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37564075

RESUMO

Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.


Objetivo: Desenvolver corregistro automático e testar seu desempenho com ou sem marcador fiducial em imagens de tomografia computadorizada de emissão de fóton único (SPECT). Materiais e Métodos: Três SPECT/CTs foram adquiridas para cada rotação de um simulador de Jaszczak em relação ao eixo da maca (0°, 5° e 10°), com e sem fiducial. Dois métodos de corregistro inelástico foram aplicados - SPM12 e NMDose-coreg -, e a porcentagem do erro quadrático médio (%RMSE) foi usada para analisar a qualidade do corregistro. Uniformidade, contraste e resolução foram medidos antes e após o corregistro. NMDose com corregistro automático foi usado para calcular a dose renal de 12 pacientes tratados com 177Lu-DOTATATE e comparado com OLINDA/EXM. Resultados: A marcação fiducial não modificou a qualidade do corregistro das imagens SPECT, medida pela %RMSE (p = 0,40). Não houve impacto na uniformidade, contraste e resolução após o corregistro de imagens adquiridas com ou sem fiduciais. Aplicação clínica preliminar mostrou tempo total de processamento de 9 ± 3 min/paciente para NMDose e 64 ± 10 min/paciente para OLINDA/EXM, com alta correlação entre ambos, apesar de menor dose renal em NMDose. Conclusão: NMDose-coreg permite o corregistro rápido de imagens SPECT, sem perda de uniformidade, contraste ou resolução. O uso da marcação fiducial não aumentou a precisão do corregistro em fantomas.

20.
Appl Radiat Isot ; 200: 110975, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37579690

RESUMO

The luminescent and dosimetric properties of the MgB4O7 phosphor co-doped with Tm and Dy ions (MgB4O7:Tm,Dy) obtained by the solution combustion technique were investigated. With the prepared material, sintered dosimeters in pellet form were made. The MgB4O7 dosimeters doped with Tm and Dy with 0.25 and 0.10 mol% respectively and sintered at 1223 K for 3 h showed a sensitivity almost 11 times greater than the sensitivity of the TLD-100 commercial dosimeter. The TL response as a function of the gamma dose showed linearity up to 50 Gy followed by a supralinearity region and, above 500 Gy, the saturation region of the electron traps is reached. The fading of the main TL peak was negligible in the first five days after irradiation reaching 13% after 60 days and the lower detection limit was 43 µGy. The kinetic parameters were determined using the deconvolution method revealing general and second order kinetics. The morphology, crystallography and photoluminescence of the prepared phosphor samples are also reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA