Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Pharm Nanotechnol ; 11(4): 373-382, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37018531

RESUMO

BACKGROUND: A drug with poor water-solubility, like Dexamethasone acetate, can present lower bioavailability conventional for pharmaceutical formulations, and the presence of polymorphs in the raw material can lead to drug quality problems. OBJECTIVE: In this study, nanocrystals of dexamethasone acetate were synthesized by high pressure homogenizer (HPH) method in surfactant poloxamer 188 (P188) solid dispersion and the bioavailable in raw material with polymorphism presence was evaluated. METHODS: The powder pre-suspension was prepared by the HPH process, and the nanoparticles formed were incorporated in P188 solutions. The nanocrystals formed were characterized by techniques of XRD, SEM, FTIR, thermal analysis by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA), dynamic light scattering (DLS) to analyze the particle size and zeta potential, and in vitro evaluation by dissolution studies. RESULTS: The characterization techniques were adequate to show the presence of raw material with physical moisture between two dexamethasone acetate polymorphs. The nanocrystals formed in the presence of the P188 in the formulation showed a considerable increase in the rate of dissolution of the drug in the medium and in the size of the stable nanocrystals, even in the presence of dexamethasone acetate polymorphs. CONCLUSION: The results showed that it was possible to produce dexamethasone nanocrystals by HPH process with regular size by the presence of the small amount of P188 surfactant. This article presents a novelty in the development of dexamethasone nanoparticles that have different polymorphic forms in their physical composition.


Assuntos
Nanopartículas , Poloxâmero , Solubilidade , Poloxâmero/química , Dexametasona , Tensoativos , Nanopartículas/química
2.
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);28(4): 1113-1123, abr. 2023. graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1430174

RESUMO

Resumo O objetivo deste artigo é investigar as evidências nacionais e internacionais disponíveis sobre o descarte de medicamentos e os impactos em matrizes ambientais. Trata-se de uma revisão integrativa da literatura realizada nas bases de dados PubMed, SciELO e Biblioteca Virtual em Saúde (BVS) e que incluiu artigos em inglês, espanhol e português publicados entre 2010 e 2020. Foram selecionados 26 artigos, que evidenciaram o descarte incorreto de medicamentos por profissionais e consumidores devido, principalmente, à falta de conhecimentos sobre os impactos ambientais que esses podem ocasionar. Estudos apontaram a contaminação de água, esgoto e sedimentos por fármacos descartados de forma incorreta. Além disso, observou-se que seres vivos aquáticos podem ser impactados pela presença de medicamentos em matrizes ambientais. O descarte de medicamentos incorreto ainda é uma realidade nas evidências avaliadas, que promove a contaminação de matrizes ambientais e muitas vezes não é removido por estações de tratamento de águas residuárias e interfere no equilíbrio da vida ambiental.


Abstract The scope of this article is to investigate the national and international evidence available on the forms of drug disposal and the presence of drugs in environmental matrices. It involved an integrative review of the literature conducted in the PubMed, SciELO and Virtual Health Library (VHL) databases, which included articles in English, Spanish and Portuguese published between 2010 and 2020. Twenty-six articles were selected, which revealed the incorrect disposal of medicines by professionals and consumers due mainly to the lack of knowledge about the environmental impacts that they may cause. Studies have highlighted the contamination of water, sewage and sediments by incorrectly discarded drugs. Furthermore, it was observed that aquatic living creatures can be impacted by the presence of drugs in environmental matrices. The incorrect disposal of drugs continues to be a reality in the evidence assessed, which leads to the contamination of environmental matrices and is often not removed by wastewater treatment plants and interferes with the equilibrium of environmental life.

3.
Anal Bioanal Chem ; 414(18): 5309-5318, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33890118

RESUMO

In this work, the batch injection analysis system with amperometric detection using reduced graphene oxide as a modifier of glassy carbon electrode (GCE) was investigated for the simple, fast, and sensitive monitoring of levofloxacin (LEVO) and ciprofloxacin (CIPRO) in samples of pharmaceutical formulations, synthetic urine, and milk (low- and high-fat content). LEVO and CIPRO were quantified in seven samples using amperometric measurements at +1.10 V vs Ag/AgCl, KCl(sat). The developed methods showed excellent analytical performance with limits of detection of 0.30 and 0.16 µmol L-1, linear range from 3.0 to 50 µmol L-1 and 1.0 to 50 µmol L-1, relative standard deviation below 9.7 and 3.1%, and recovery ranges ranging from 80 to 107% and from 78 to 109% for LEVO and CIPRO, respectively. In addition, the minimum sample preparation (simple dilution) combined with a high analytical frequency (130 to 180 analyses per hour) can be highlighted. Thus, the methods are promising for implementation in routine analysis and quality control to different samples.


Assuntos
Carbono , Fluoroquinolonas , Animais , Carbono/análise , Ciprofloxacina/análise , Composição de Medicamentos , Eletrodos , Fluoroquinolonas/análise , Grafite , Leite/química
4.
Nat Prod Res ; 35(24): 6034-6039, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32924590

RESUMO

Leaves of Kalanchoe pinnata are used worldwide for healing skin wounds. This study aimed to develop and compare two creams containing a leaf aqueous extract of K. pinnata (KP; 6%) and its major flavonoid [quercetin 3-O-α-L-arabinopyranosyl-(1→2)-α-L-rhamnopyranoside] (0.15%). Both creams were topically evaluated in a rat excision model for 15 days. On the 12th day, groups treated with KP leaf-extract and KP major flavonoid creams exhibited 95.3 ± 1.2% and 97.5 ± 0.8% of healing, respectively (positive control = 96.7 ± 0.8%; negative control = 76.1 ± 3.8%). Both resulted in better re-epithelialization and denser collagen fibres. Flavonol glycosides are the main phenolics in KP leaf-extract according to HPLC-ESI-MS/MS analysis. KP major flavonoid plays a fundamental role in the wound healing. The similar results found for both creams indicate that the use of KP crude extract should be more profitable than the isolated compound.


Assuntos
Kalanchoe , Animais , Flavonoides , Extratos Vegetais , Folhas de Planta , Ratos , Espectrometria de Massas em Tandem , Cicatrização
5.
Vet Res Commun ; 44(3-4): 89-100, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32656740

RESUMO

Antimicrobial resistance is a worldwide spread phenomenon that affects both human and veterinary medicine. This issue has led to a "One Health" approach in order to coordinate efforts and set back the development of drug-resistant microbes. In the search for alternatives therapies, bacteriocins or antimicrobial peptides have proven to be effective both in vitro and in vivo for multiples pathogens, even those resistant to many classic antibiotics. Gram-positive bacteriocins have been the most studied to the present. The use of bacteriocins as therapeutically active molecules is limited mainly due to difficulties in production, purification, delivery systems and regulatory approvals. To overcome some of these limitations, biotechnological and nanotechnological approaches are evaluated. Bacteriocins proved to be a good complement for conventional antibiotics therapy. Antimicrobial peptides are nowadays included in the veterinary products such as udder disinfectant for dairy cattle and dermatological medicated wipe for topical use on dogs, cats, and horses. But there are other potential uses to explore in the veterinary field for both companion and production animals.


Assuntos
Anti-Infecciosos/uso terapêutico , Bacteriocinas/uso terapêutico , Bactérias Gram-Positivas/efeitos dos fármacos , Medicina Veterinária , Medicina Veterinária/métodos
6.
Braz. J. Pharm. Sci. (Online) ; 56: e17784, 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1089223

RESUMO

Two simple, selective and sensitive spectrophotometric methods were developed and validated for the determination of valganciclovir hydrochloride (VLGH) in pure drug and tablets. The first method was based on the reduction of iron(III) to iron(II) by VLGH and subsequent formation of iron(III)-ferricyanide complex (Prussian blue) in acid medium which was measured at 730 nm (method A). In the second method (method B), permanganate was reduced by VLGH to bluish green manganate in alkaline medium and the absorbance was measured at 610 nm. The absorbance measured in each case was related to VLGH concentration. The experimental conditions were carefully studied and optimized. Beer's law was obeyed over the concentration ranges of 2.5-20.0 and 2.0-40.0 µg mL-1 for method A and method B, respectively, with corresponding molar absorptivity values of 1.28×104 and 6.88×103 L mol-1 cm-1. The limits of detection (LOD) and quantification (LOQ) were 0.11 and 0.33 µg mL-1 (method A) and 0.21 and 0.64 µg mL-1 (method B). Within-day and between-day relative standard deviations (%RSD) at three different concentrations levels were < 2.4%, and the respective relative errors (%RE) were ≤ 3%. The proposed methods were successfully applied to the determination of VLGH in tablets, and the results confirmed that the proposed methods were equally precise and accurate as the official method.

7.
J. Health Sci. Inst ; 37(3): 199-202, july-sept 2019. ilus
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1355142

RESUMO

Objetivo ­ Avaliar o uso da espectroscopia Raman como possível instrumento para a detecção do Ibuprofeno em diferentes formulações farmacêuticas a fim de se propor uma metodologia a ser utilizada em processos de controle de qualidade na produção destes medicamentos. Métodos ­ 05 amostras de cada grupo do medicamento (referência, genérico e similar) concentrado em 100 mg/dL, foram submetidas a espectroscopia Raman (espectrômetro dispersivo com 830 nm e 300 mW de excitação acoplado a um cabo de fibras ópticas Raman probe) e as aquisições foram replicadas 10 vezes de 3 segundos, com exposição total de 30 s para a coleta de cada espectro. Resultados ­ Ao se comparar o medicamento similar com o de referência, percebem-se picos mais elevados e largos no similar, principalmente nos deslocamentos de 510, 660 e 884 cm­1. Já os espectros dos medicamentos de referência e genérico mostraram-se mais semelhantes entre si. Conclusão ­ As três apresentações comerciais contêm o princípio ativo Ibuprofeno, porém os picos em diferentes intensidades sugerem diferentes concentrações nas formulações avaliadas.


Objective ­ To evaluate the use of Raman spectroscopy as a possible instrument for the detection of ibuprofen in different pharmaceutical formulations in order to propose a methodology to be used in quality control processes in the production of these drugs. Methods ­ 05 samples from each drug group (reference, 100 mg / dL, were subjected to Raman spectroscopy (830 nm dispersive spectrometer and 300 mW excitation coupled to a Raman probe fiber optic cable) and acquisitions replicated 10 times 3 seconds with exposure 30 s total for the collection of each spectrum. Results ­ When comparing the similar drug with the reference drug, higher and broader peaks in the similar one can be noticed, especially in the displacements of 510, 660 and 884 cm­1. Already the spectra of reference and generic drugs were more similar to each other. Conclusion ­ The three commercial presentations contain the active ingredient Ibuprofen, but the peaks at different intensities suggest different concentrations in the formulations evaluated.

8.
J Pharm Biomed Anal ; 167: 15-20, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30738239

RESUMO

Candida albicans is an opportunistic pathogenic yeast commonly found in mouth, gastrointestinal tract and vagina. Under certain conditions, it causes skin, mucosal and systemic infections. With growing concern over the emergence of resistant strains to conventional antifungals, the development of novel antifungal agents for the management of this pathogen is an urgent need. In the present work, novel bioextracts from folk medicinal plants were directly used as active ingredient in a topical formulation for dermal candidiasis. With the aim to replace hazardous traditional reagents, a natural solvent composed by lactic acid: glucose: water (LGH) was used as vehicle for bioactive compound extraction. Furthermore, phenolic and alkaloid composition were determined by HPLC and their individual antifungal effect was evaluated. LGH extracts of Larrea spices demonstrate a significant antimicrobial activity against C. albicans being higher than their individual bioactive constituents. Notably, the mixture of Larrea cuneifolia and L divaricata extracts in topical formulations reveal a synergistic antifungal effect highlighting their potential for candidiasis treatment.


Assuntos
Antifúngicos/farmacologia , Candida albicans/efeitos dos fármacos , Larrea/química , Extratos Vegetais/farmacologia , Solventes/química , Antifúngicos/isolamento & purificação , Composição de Medicamentos , Glucose/química , Ácido Láctico/química , Testes de Sensibilidade Microbiana , Extratos Vegetais/isolamento & purificação , Água/química
9.
Int J Pharm ; 552(1-2): 119-129, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30266516

RESUMO

In formulations of nanostructured lipid carriers, lipid solid dispersions and self-emulsifying drug delivery systems, it is common that a solid or semi-solid lipid excipient is mixed with a liquid solvent or liquid lipid. Even when the excipients are visually miscible upon melting, they might have microscopic non-homogeneities which could lead to instability over time and future phase separation. Raman mapping associated with chemometric methods can be useful to evaluate spatial distribution of compounds, however it has not been extensively applied to the formulations mentioned above. The aim of this work was to compare the outcomes of three different chemometric methods - principal components analysis (PCA), multivariate curve resolution with alternating least squares (MCR-ALS) and independent components analysis (ICA) - to study two systems of very different degrees of microscopic miscibility: cetyl palmitate + Transcutol© (heterogeneous) and polyethylene glycol 6000 (PEG 6000) + Tween 80© (homogeneous). These two samples were chosen due to large differences in spatial distribution of the compounds over the pixels which could require different approaches for data treatment. The three methods were compared regarding recovered concentrations (or scores), signals (or loadings) and the need for matrix augmentation to obtain reliable results. Results showed that PCA loadings were the mathematical differences of the spectra of pure compounds for both samples, and therefore only 'contrast images' could be generated. MCR and ICA provided signals that could be related to the chemical components, however MCR presented rotational ambiguities even for the very heterogeneous sample, a situation in which ICA performed better as a blind search method. For the homogeneous sample, both methods showed rank deficiency and therefore the use of a matrix augmentation was necessary. ICA and PCA allowed identifying physical modifications in the homogeneous semi-solid PEG 6000/Tween 80® sample over the time, probably due to the folding/unfolding of the crystalline chains of PEG 6000. Therefore, this work discusses the ability of the three chemometrics methods to extract information from Raman spectra in order to characterize the chemical, spatial and even physical aspects of semi-solid pharmaceutical formulations, which could be of much use for stability studies of different drug delivery systems.


Assuntos
Excipientes/química , Preparações Farmacêuticas/química , Análise Espectral Raman , Etilenoglicóis/química , Análise dos Mínimos Quadrados , Palmitatos/química , Polietilenoglicóis/química , Polissorbatos/química , Análise de Componente Principal
10.
Eur J Pharm Sci ; 112: 146-151, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-29174987

RESUMO

Meloxicam (MLX) is a non-steroidal anti-inflammatory cyclooxygenase (COX) inhibitor that is used to relieve inflammation and pain. MLX has a preferential affinity for COX-2, which is associated with a lower incidence of gastrointestinal side effects. The drug belongs to Class II of the Biopharmaceutical Classification System (BCS) in which dissolution is the limiting step of its bioavailability. In view of this classification, carrying out further studies regarding the compatibility of MLX with excipients and the mechanisms and kinetics of its degradation reactions is fundamental because any changes would directly influence the quality of the product. The aim of the present work is to evaluate solid pharmaceutical formulations containing MLX found on the market to define the more suitable excipients to improve the stability of the pharmaceutical formulations. Thermal analysis techniques were used to characterize and evaluate the compatibility between the drug and the excipients present in the market formulations. In the evaluation of its solid-state kinetics, MLX raw material under inert conditions had a shelf life of approximately 6years. In the study of compatibility between the drug and excipients, MLX was found to be incompatible with magnesium stearate after DSC analysis under binary mixtures, which was confirmed by stress studies and chromatographic analyzes.


Assuntos
Anti-Inflamatórios não Esteroides/química , Excipientes/química , Tiazinas/química , Tiazóis/química , Varredura Diferencial de Calorimetria , Composição de Medicamentos , Estabilidade de Medicamentos , Meloxicam
11.
Braz. J. Pharm. Sci. (Online) ; 53(3): e00075, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889408

RESUMO

ABSTRACT This work presents the development of a methodology based on the formation of a charge transfer complex between quinalizarin and rosuvastatin, allowing for the spectrophotometric determination of rosuvastatin at 579 nm. The factors involved in the sensitivity of the technique were studied (nature and proportion of the solvent, reaction time, pH of aqueous phase and quinalizarin concentration). The proposed spectrophotometric procedures were validated with respect to linearity, ranges, precision, accuracy, detection and quantification limits. Calibration curves of the formed color products showed good linear relationships over the concentration range of 6-15 mg L-1. The proposed method has been successfully applied, which can be confirmed by interference test (comparison between the standard curves and addition of analyte), method precision (RSD 2.3% to 6 mg L-1), and by accuracy (statistically equivalent results between the proposed method and a chromatographic method of reference).


Assuntos
Espectrofotometria/métodos , Composição de Medicamentos/estatística & dados numéricos , Rosuvastatina Cálcica/análise , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Metodologia como Assunto
12.
Braz. j. pharm. sci ; 52(4): 741-750, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951867

RESUMO

ABSTRACT Folic acid is a B complex water-soluble vitamin that is essential to humans, and its deficiency can cause problems including congenital malformations in the fetus as well as heart disease. Most countries affected by diseases associated with a lack of folic acid now supplement foods with the vitamin. There is therefore a need for the development of new analytical procedures able to determine folic acid present in different matrices. This work describes the development of zero order and first order derivative spectrophotometric methods for the determination of folic acid in different pharmaceutical formulations, using 0.1 mol L-1 NaOH as solvent. The methods are shown to be simple, selective, and robust. Good linearity was achieved, with correction coefficients ≥0.9996 and limits of detection and quantification ranging from 0.64 to 0.75 and from 1.80 to 2.85 mg L-1, respectively. Recoveries of 98-104% were obtained in accuracy tests, and precision (as RSD) was between 0.2 and 4.8%. The methods can be used in routine analyses for quality control purposes, offering an alternative to the procedures already reported in the literature


Assuntos
Preparações Farmacêuticas/administração & dosagem , Estudo de Validação , Ácido Fólico/análise , Espectrofotometria/métodos
13.
Braz. j. pharm. sci ; 51(2): 429-437, Apr.-June 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-755057

RESUMO

In this approach, a new voltammetric method for determination of norfloxacin was proposed with high sensitivity and wider detection linear range. The used voltammetric sensor was fabricated simply by coating a layer of graphene oxide (GO) and Nafion composited film on glassy carbon electrode. The advantage of proposed method was sensitive electrochemical response for norfloxacin, which was attributed to the excellent electrical conductivity of GO and the accumulating function of Nafion under optimum experimental conditions, the present method revealed a good linear response for determination of norfloxacin in the range of 1×10-8mol/L-7×10-6 mol/L with a detection limit of 5×10-9 mol/L. The proposed method was successfully applied in the determination of norfloxacin in capsules with satisfactory results...


Propos-se, por essa abordagem, novo método voltamétrico, com alta sensibilidade e faixa linear de detecção mais ampla, para a determinação de norfloxacino. O sensor voltamétrico utilizado foi fabricado simplismente por cobertura de camada de óxido de grafeno (GO) e filme de Nafion em eletrodo de cabrono vítreo. A vantagem do método proposto foi a resposta eletroquímica sensível para o norfloxacino, atribuída à condutividade elétrica excelente do GO e à função acumulada do Nafion. Sob condições experimentais ótimas, o presente método revelou boa resposta linear para a determinação do norfloxacino na faixa de limite de detecção de 1×10-8mol/L-7×10-6 mol/L. O método proposto foi aplicado com sucesso na determinação de norfloxacino em cápsulas, com resultados satisfatórios...


Assuntos
Humanos , Norfloxacino/análise , Química Farmacêutica/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos
14.
Braz. j. pharm. sci ; 51(2): 285-294, Apr.-June 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-755069

RESUMO

This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.87, and accuracy (relative error) was better than 4.12%. The method developed in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. In addition, the proposed technique was successfully applied to spiked human serum samples. No electro-active interferences from the endogenous substances were found in human serum...


Este artigo descreve um método de voltametria de pulso diferencial (VPD) para a determinação de diclofenaco em preparações farmacêuticas e em soro humano. O método proposto foi baseado em eletroxidação de diclofenaco no eléctrodo de platina em solução 0,1 M TBAClO4/acetonitrila. Dois picos de oxidação bem definidos foram observados em 0,87 e 1,27 V, respectivamente. As curvas de calibração obtidas utilizando-se valores de corrente medidos por segundo pico foram lineares no intervalo de concentração de 1,5-17,5 μg mL-1e 2-20 μg mL-1em eletrólito suporte e soro, respectivamente. Precisão e exatidão também foram verificadas em todos os meios. Valores de precisão intra- e inter-dia para o diclofenaco foram inferiores a 3.87 e a precisão (erro relativo) foi melhor do que 4,12%. O método desenvolvido neste estudo é exato, preciso e pode ser facilmente aplicado a Diclomec, Dicloflam e comprimidos Voltaren, como preparação farmacêutica. Além disso, a técnica proposta foi aplicada com sucesso em amostras de soro humano. Não se observaram interferências das substâncias endógenas no soro humano...


Assuntos
Humanos , Diclofenaco/análise , Diclofenaco/farmacologia , Diclofenaco/sangue , Testes de Química Clínica/métodos , Química Farmacêutica/métodos , Técnicas Eletroquímicas/métodos
15.
Luminescence ; 30(3): 337-42, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25060163

RESUMO

This work reports the development and optimization of a flow injection analysis system with fluorescence detection (FIA-FLUO) for gatifloxacin (GFX) determination in organized medium. The analytical system was based on the enhanced fluorescence of gatifloxacin in micellar medium containing sodium dodecyl sulfate (SDS) at pH 6.0. The influence of physical (carrier flow rate, sample volume and volume of reaction coil) and chemical (pH, concentration of buffer and concentration of SDS) parameters that could affect the performance of the FIA system was evaluated in order to reach optimum conditions in terms of sensitivity and analytical throughput. Under optimized conditions, the FIA-FLUO system allowed the injection of 40 samples per hour with a limit of quantification of 72 µg/L and a RSD of 3.5% at 0.20 mg/L. Real samples of commercial pharmaceutical formulations containing GFX were analyzed, and no statistical difference was observed between the results obtained using the developed system and those obtained using the reference method based on high-performance liquid chromatography with UV detection.


Assuntos
Análise de Injeção de Fluxo/instrumentação , Análise de Injeção de Fluxo/métodos , Fluoroquinolonas/análise , Espectrometria de Fluorescência/métodos , Cromatografia Líquida de Alta Pressão/métodos , Desenho de Equipamento , Gatifloxacina , Concentração de Íons de Hidrogênio , Limite de Detecção , Micelas , Soluções Oftálmicas/análise , Sensibilidade e Especificidade , Dodecilsulfato de Sódio , Espectrofotometria Ultravioleta
16.
Braz. j. pharm. sci ; 51(1): 43-52, Jan-Mar/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751362

RESUMO

One titrimetric and two spectrophotometric methods are proposed for the determination of diethylcarbamazine citrate (DEC) in bulk drug and in formulations using potassium iodate and potassium iodide as reagent. The methods employ the well-known analytical reaction between iodate and iodide in the presence of acid. In titrimetry (method A), the drug was treated with a measured excess of thiosulfate in the presence of unmeasured excess of iodate-iodide mixture and after a standing time of 10 min, the surplus thiosulfate was determined by back titration with iodine towards starch end point. Titrimetric assay is based on a 1:3 reaction stoichiometry between DEC and iodine and the method is applicable over 2.0-10.0 mg range. The liberated iodine is measured spectrophotometrically at 370 nm (method B) or the iodine-starch complex measured at 570 nm (method C). In both methods, the absorbance is found to be linearly dependent on the concentration of iodine, which in turn is related to DEC concentration. The calibration curves are linear over 2.5-50 and 2.5-30 µg mL-1 DEC for method B and method C, respectively. The calculated molar absorptivity and Sandell sensitivity values were 6.48×103 L mol-1 cm-1 and 0.0604 µg cm-2, respectively, for method B, and their respective values for method C are 9.96×103 L mol-1 cm-1 and 0.0393 µg cm-2. The intra-day and inter-day accuracy and precision studies were carried out according to the ICH guidelines. The methods were successfully applied to the analysis of DEC formulations.


Propõem-se titulação e dois métodos espectrofotométricos para a determinação de citrato de dietilcarbamazina (DEC) a granel e em suas formulações, usando iodato de potássio e iodeto de potássio como reagente. Os métodos utilizam a reação analítica conhecida entre iodato e iodeto, na presença de ácido. Na titulometria (Método A), o fármaco foi tratado com excesso medido de tiossulfato, na presença de excesso não medido de mistura iodato-iodeto e, depois de um tempo de repouso de 10 min, o excesso de tiossulfato foi determinado por titulação de retorno com iodo até o ponto final com amido. A titulação é baseada em reação com estequiometria 1:3 entre DEC e iodo e o método é aplicável na faixa de 2.0-10.0 mg. O iodo liberado é medido espectrofotometricamente a 370 nm (método B) ou o complexo de iodo-amido medido a 570 nm (método C). Em ambos os métodos, a absorvância é considerada linearmente dependente da concentração de iodo, a qual, por sua vez, está relacionada à concentração de DEC. As curvas de calibração são lineares para concentrações de DEC de 2.5-50 e 2.5-30 mg mL- 1 para o método B e para o método C, respectivamente. A absortividade molar calculada e os valores de sensibilidade Sandel foram 6.48×103 L mol-1 cm- 1 e 0.0604 ug cm-2, respectivamente, para o método B, e os seus respectivos valores para o método C são 9.96×103 L mol-1 cm-1 e 0.0393 mg cm-2. Os estudos de exatidão e precisão intra-dia e inter-dia foram realizados de acordo com as diretrizes da ICH. Os métodos foram aplicados com sucesso na análise de formulações de DEC.


Assuntos
Espectrofotometria , Dietilcarbamazina/análise , Iodatos/análise , Iodetos/análise , Química Farmacêutica/classificação , Titulometria/métodos
17.
Braz. j. pharm. sci ; 51(3): 699-708, July-Sept. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-766310

RESUMO

This article describes the application and performance of an inexpensive, simple and portable device for colorimetric quantitative determination of drugs in pharmaceutical preparations. The sensor is a light detector resistor (LDR) incorporated into a black PTFE cell and coupled to a low-cost multimeter (Ohmmeter). Quantitative studies were performed with captopril/p-chloranil/H2O2 and methyldopa/ammonium molybdate systems. Calibration curves were obtained by plotting the electrical resistance of the LDR against the concentration of the colored species in the ranges 1.84 × 10-4 to 1.29 × 10-3mol L-1 and 5.04 × 10-4 to 2.52 × 10-3 mol L-1 for captopril/p-chloranil/H2O2 and methyldopa/ammonium molybdate systems, respectively, exhibiting good coefficients of determination. Statistical analysis of the results obtained showed no significant difference between the proposed methodologies and the official reported methods, as evidenced by the t-test and variance ratio at a 95% confidence level. The results of this study demonstrate the applicability of the instrument for simple, accurate, precise, fast,in situ and low-cost colorimetric analysis of drugs in pharmaceutical products.


Este artigo descreve o desenvolvimento e a aplicação de um dispositivo portátil, simples e barato para a determinação colorimétrica quantitativa de fármacos em formulações farmacêuticas. O sensor é um resistor detector de luz (RDL) colocado numa célula de PTFE e acoplado a um multímetro de baixo custo. Os estudos quantitativos foram realizados utilizando captopril/p-cloranil/H2O2 e metildopa/molibdato de amônio como sistemas reacionais. As curvas de calibração foram obtidas através da representação gráfica da resistência elétrica do RDL contra a concentração dos complexos coloridos formados nas faixas de 1,84 × 10-4 e 1,29 × 10-3 mol L-1 e 5,04 × 10-4 e 2,52 × 10- 3 mol L-1 para captopril/p-cloranil/H2O2 e de metildopa/molibdato de amônio, respectivamente, com bons coeficientes de determinação. As análises estatísticas dos resultados obtidos mostraram que não houve diferença significativa entre os métodos propostos e os métodos oficiais como evidente a partir dos testes "t-Student" eF-Fisher, com nível de confiança de 95%. Os resultados deste estudo demonstram que o instrumento proposto neste trabalho é simples, de fácil operação, baixo custo e apresentou boa exatidão e boa precisão para o doseamento de fármacos em medicamentos.


Assuntos
Preparações Farmacêuticas , Colorimetria/métodos , Controle de Qualidade , Dosagem
18.
Braz. j. pharm. sci ; 51(3): 653-661, July-Sept. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-766319

RESUMO

The present work describes development and validation of a specific, sensitive, precise and stability-indicating high-performance liquid chromatographic method of analysis of atorvastatin calcium and celecoxib, both as a bulk drug and in niosomal formulation. The analysis has been performed by using Cosmosil-C18 column (4.6 mm´250 mm, 5 m) at 25 °C using acetonitrile: ammonium acetate buffer pH 5.0: methanol (50:25:25 v/v/v) as mobile phase. The detection was carried out at 277nm with a flow rate of 1.0mL/min. The retention times of Atorvastatin calcium and Celecoxib were 6.195 and 3.989min, respectively. The method was validated according to ICH guidelines, for specificity, precision, linearity, accuracy and robustness. Atorvastatin calcium and Celecoxib were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation was observed in oxidation and acid hydrolysis. The linearity for atorvastatin calcium and celecoxib were in the range of 100-500 µg/mL. The recovery study of atorvastatin and celecoxib were found to be in the range of 98.96 - 99.92% and 98.90-100%, respectively. The proposed method was validated and successfully applied to the estimation of Atorvastatin calcium and Celecoxib in combined in-house niosomal formulation.


O presente trabalho descreve o desenvolvimento e a validação de método de análise por cromatografia de alta eficiência específico, sensível, preciso e indicador de estabilidade de atorvastatina cálcica e celecoxibe, ambos como fármaco e como formulação niosômica. A análise foi realizada utilizando coluna Cosmosil-C18 (4,6 mm´250 mm, 5 m) a 25 °C, e acetonitrila: tampão acetato de amônio pH 5,0: metanol (50:25:25 v/v/v) como fase móvel. A detecção foi realizada a 277 nm, com fluxo de 1,0 mL/min. Os tempos de retenção de atorvastatina cálcica e de celecoxibe foram 6,195 e 3,989 min, respectivamente. O método foi validado de acordo com as regras da ICH para especificidade, precisão, exatidão e robustez. A atorvastatina cálcica e o celecoxibe foram submetidos a condições de estresse por hidrólise, oxidação, fotólise e degradação térmica. A degradação foi observada por oxidação e hidrólise ácida. Observou-se a linearidade da atorvastatina cálcica e do celecoxibe na faixa de 100-500 µg/mL. A recuperação da atorvastatina e do celecoxibe foi observada na faixa de 98,96-99,92% e 98,90-100%, respectivamente. O método proposto foi validado e aplicado com sucesso para a determinação de atorvastatina cálcica e celecoxibe em formulação niosômica caseira combinada.


Assuntos
Estudo de Validação , Cromatografia de Fase Reversa , Celecoxib/análise , Atorvastatina/análise , Química Farmacêutica/métodos , Cromatografia Líquida
19.
Talanta ; 123: 45-53, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24725863

RESUMO

The aim of this study was to develop a new multilayer coating with crosslinked quaternary ammonium chitosan (hydroxypropyltrimethyl ammonium chloride chitosan; HACC) and κ-carrageenan for use in capillary electrophoresis. A new semi-permanent multilayer coating was formed using the procedure developed and the method does not require the presence of polymers in the background electrolyte (BGE). The new capillary multilayer coating showed a cathodic electroosmotic flow (EOF) of around 30×10(-9) m(2) V(-1) s(-1) which is pH-independent in the range of pH 2 to 10. The enhanced EOF at low pH obtained contributed significantly to the development of a fast method of separation. The multilayer coating was then applied in the development of a fast separation method to determine betaine and methionine in pharmaceutical formulations by capillary zone electrophoresis (CZE). The BGE used to determine the betaine and methionine concentrations was composed of 10 mmol L(-1) tris(hydroxymethyl) aminomethane, 40 mmol L(-1) phosphoric acid and 10% (v/v) ethanol, at pH 2.1. A fused-silica capillary of 32 cm (50 µm ID×375 µm OD) was used in the experiments and samples and standards were analyzed employing the short-end injection procedure (8.5 cm effective length). The instrumental analysis time of the optimized method was 1.53 min (approx. 39 runs per hour). The validation of the proposed method for the determination of betaine and methionine showed good linearity (R(2)>0.999), adequate limit of detection (LOD <8 mg L(-1)) for the concentration in the samples and inter-day precision values lower than 3.5% (peak area and time migration). The results for the quantification of the amino acids in the samples determined by the CZE-UV method developed were statistically equal to those obtained with the comparative LC-MS/MS method according to the paired t-test with a confidence level of 95%.


Assuntos
Carragenina/química , Quitosana/análogos & derivados , Eletroforese Capilar/métodos , Compostos de Amônio Quaternário/química , Betaína/análise , Betaína/química , Sequência de Carboidratos , Quitosana/química , Cromatografia Líquida/métodos , Eletrólitos , Eletro-Osmose , Concentração de Íons de Hidrogênio , Metionina/análise , Metionina/química , Dados de Sequência Molecular , Estrutura Molecular , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Fatores de Tempo
20.
Luminescence ; 29(7): 901-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24585556

RESUMO

An automated multi-pumping flow system is proposed for the chemiluminometric determination of ascorbic acid in pharmaceutical formulations, relying on the ability of semiconductor nanocrystals to generate short-lived reactive species upon photo-irradiation. A photo-unit based on visible-light-emitting diodes is used to photo-excite cadmium telluride (CdTe) quantum dots capped with glutathione, leading to the generation of radicals that react with luminol under alkaline conditions, yielding the chemiluminescence. Ascorbic acid acts as a radical scavenger, preventing the oxidation of luminol, thus ensuring a concentration-dependent chemiluminescence quenching. After system optimization, a linear working range of 5.0 × 10(-7) to 5.0 × 10(-6) mol/L ascorbic acid (r = 0.9967, n = 5) was attained, with a detection limit of 3.05 × 10(-7) mol/L and a sampling rate of 200/h. The flow system was applied to the analysis of pharmaceutical formulations and the results were in good agreement with those obtained by the reference titrimetric procedure (RD < ± 4.3%, n = 7).


Assuntos
Ácido Ascórbico/análise , Compostos de Cádmio/química , Glutationa/química , Pontos Quânticos , Telúrio/química , Química Farmacêutica , Medições Luminescentes , Luminol/química , Estrutura Molecular , Processos Fotoquímicos , Espécies Reativas de Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA