Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Rev. cuba. med. trop ; 67(3)dic. 2015. ilus, tab
Artigo em Espanhol | CUMED | ID: cum-64879

RESUMO

Introducción: la brucelosis es una zoonosis perjudicial para la salud humana y veterinaria. Cuba incrementa la ganadería no controlada productora de alimentos que unida a otras prácticas agrícolas, inciden en el aumento de la morbilidad por esta enfermedad. La red nacional de laboratorios de salud pública de Cuba, carece de métodos de laboratorio para el diagnóstico de la brucelosis humana. Objetivos: evaluar cualitativamente el sistema serológico comercial Febrille Antigen Brucella, para detección de anticuerpos contra brucelas, con el uso de sueros de casos y controles. Confirmar la infección por brucelas con la aplicación del sistema serológico comercial para la detección de anticuerpos contra brucelas y los sistemas comerciales de referencia ELISA-IgM e IgG, en sueros de pacientes sospechosos de brucelosis. Realizar una descripción parcial de costos, del sistema serológico comercial Febrille Antigen Brucella. Métodos: se realizó una investigación en servicios y sistemas de tipo observacional con un estudio de caso control anidado, con cuarenta sueros de casos, 80 controles y 466 muestras de pacientes sospechosos, para evaluar el sistema comercial Febrille Antigen Brucella, (Diagnostic Senese SpA), al que se le efectuó también una evaluación económica parcial de costos. Se utilizaron como pruebas de referencia ELISA-IgM y ELISA-IgG (VIRCELL, España). Resultados: el sistema de Febrille Antigen Brucella mostró valores de sensibilidad de 100,00 por ciento, especificidad de 97,50 pir ciento y una concordancia de 98,33 por ciento. De los 72 casos clínicos, 25 presentaron títulos ≥ 160 por Febrille Antigen...(AU)


Introduction: brucellosis is a zoonosis detrimental to human and animal health. Cuba increases food-producing uncontrolled stockbreeding, a fact that, together with other farming activities, influences the increase in morbidity for this disease. The Cuban national network of public health laboratories lacks laboratory methods for diagnosis human brucellosis.Objectives: to qualitatively evaluate the commercial serological system Febrile Antigen Brucella for the detection of anti-Brucella antibodies, with the use of serums from cases and controls; to confirm Brucella infection, by means of the application of the commercial serological system for anti-Brucella antibodies detection and the commercial systems of reference ELISA-IgM and ELISA-IgG in serums from patients suspected of brucellosis; and to partially describe the costs of the commercial serological system Febrile Antigen Brucella. Methods: observational research carried out in services and systems, by a nested case-control study, with 40 serums from cases, 80 controls and 466 samples from suspect patients, in order to evaluate the commercial system Febrile Antigen Brucella (Diagnostica Senese SpA), which besides was object to a partial economic evaluation of costs. As reference tests, ELISA-IgM and ELISA-IgG (VIRCELL, España) were used. Results: the Febrile Antigen Brucella system showed sensitivity values of 100.00 percent, specificity of 97.50 percent and agreement coefficient of 98.33 percent. Out of the 72 clinical cases, 25 presented titles greater than or equal to 160 by Febrile Antigen Brucella and were positive also by ELISA-IgM and ELISA-IgG. The use of the systems ELISA-IgM and ELISA-IgG in Febrile Antigen Brucella-reactive and suspect serums increased serological positivity. Mean average cost (21.46 CUP) for one determination by Febrile Antigen...(AU)


Assuntos
Brucelose/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA