Your browser doesn't support javascript.
loading
Evaluación del sistema serológico Febrille Antigen Brucella para la pesquisa de anticuerpos contra brucelas, en Cuba / Evaluation of the serological system Febrile Antigen Brucella for the detection of anti-Brucella antibodies in Cuba
Obregón Fuentes, Ana Margarita; Muñoz Núñez, Kiryan; Echevarría Pérez, Eduardo; Rodríguez Olivera, Yaindrys; Baly Gil, Alberto; Toledo Romaní, Maria Eugenia; Rodriguez Silveira, José; Valdés Labrador, Yanais.
Afiliação
  • Obregón Fuentes, Ana Margarita; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Muñoz Núñez, Kiryan; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Echevarría Pérez, Eduardo; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Rodríguez Olivera, Yaindrys; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Baly Gil, Alberto; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Toledo Romaní, Maria Eugenia; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Rodriguez Silveira, José; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Valdés Labrador, Yanais; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
Rev. cuba. med. trop ; 67(3)dic. 2015. ilus, tab
Article em Es | CUMED | ID: cum-64879
Biblioteca responsável: CU1.1
Localização: CU1.1
RESUMEN
Introducción: la brucelosis es una zoonosis perjudicial para la salud humana y veterinaria. Cuba incrementa la ganadería no controlada productora de alimentos que unida a otras prácticas agrícolas, inciden en el aumento de la morbilidad por esta enfermedad. La red nacional de laboratorios de salud pública de Cuba, carece de métodos de laboratorio para el diagnóstico de la brucelosis humana. Objetivos: evaluar cualitativamente el sistema serológico comercial Febrille Antigen Brucella, para detección de anticuerpos contra brucelas, con el uso de sueros de casos y controles. Confirmar la infección por brucelas con la aplicación del sistema serológico comercial para la detección de anticuerpos contra brucelas y los sistemas comerciales de referencia ELISA-IgM e IgG, en sueros de pacientes sospechosos de brucelosis. Realizar una descripción parcial de costos, del sistema serológico comercial Febrille Antigen Brucella. Métodos: se realizó una investigación en servicios y sistemas de tipo observacional con un estudio de caso control anidado, con cuarenta sueros de casos, 80 controles y 466 muestras de pacientes sospechosos, para evaluar el sistema comercial Febrille Antigen Brucella, (Diagnostic Senese SpA), al que se le efectuó también una evaluación económica parcial de costos. Se utilizaron como pruebas de referencia ELISA-IgM y ELISA-IgG (VIRCELL, España). Resultados: el sistema de Febrille Antigen Brucella mostró valores de sensibilidad de 100,00 por ciento, especificidad de 97,50 pir ciento y una concordancia de 98,33 por ciento. De los 72 casos clínicos, 25 presentaron títulos ≥ 160 por Febrille Antigen...(AU)
ABSTRACT
Introduction: brucellosis is a zoonosis detrimental to human and animal health. Cuba increases food-producing uncontrolled stockbreeding, a fact that, together with other farming activities, influences the increase in morbidity for this disease. The Cuban national network of public health laboratories lacks laboratory methods for diagnosis human brucellosis.Objectives: to qualitatively evaluate the commercial serological system Febrile Antigen Brucella for the detection of anti-Brucella antibodies, with the use of serums from cases and controls; to confirm Brucella infection, by means of the application of the commercial serological system for anti-Brucella antibodies detection and the commercial systems of reference ELISA-IgM and ELISA-IgG in serums from patients suspected of brucellosis; and to partially describe the costs of the commercial serological system Febrile Antigen Brucella. Methods: observational research carried out in services and systems, by a nested case-control study, with 40 serums from cases, 80 controls and 466 samples from suspect patients, in order to evaluate the commercial system Febrile Antigen Brucella (Diagnostica Senese SpA), which besides was object to a partial economic evaluation of costs. As reference tests, ELISA-IgM and ELISA-IgG (VIRCELL, España) were used. Results: the Febrile Antigen Brucella system showed sensitivity values of 100.00 percent, specificity of 97.50 percent and agreement coefficient of 98.33 percent. Out of the 72 clinical cases, 25 presented titles greater than or equal to 160 by Febrile Antigen Brucella and were positive also by ELISA-IgM and ELISA-IgG. The use of the systems ELISA-IgM and ELISA-IgG in Febrile Antigen Brucella-reactive and suspect serums increased serological positivity. Mean average cost (21.46 CUP) for one determination by Febrile Antigen...(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Brucelose / Ensaio de Imunoadsorção Enzimática Tipo de estudo: Diagnostic_studies / Observational_studies País/Região como assunto: Cuba Idioma: Es Revista: Rev. cuba. med. trop Ano de publicação: 2015 Tipo de documento: Article
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Brucelose / Ensaio de Imunoadsorção Enzimática Tipo de estudo: Diagnostic_studies / Observational_studies País/Região como assunto: Cuba Idioma: Es Revista: Rev. cuba. med. trop Ano de publicação: 2015 Tipo de documento: Article