RESUMO
BACKGROUND AND PURPOSE: Enhancing afferent information from the paretic limb can improve post-stroke motor recovery. However, uncertainties exist regarding varied sensory peripheral neuromodulation protocols and their specific impacts. This study outlines the use of repetitive peripheral sensory stimulation (RPSS) and repetitive magnetic stimulation (rPMS) in individuals with stroke. METHODS: This scoping review was conducted according to the JBI Evidence Synthesis guidelines. We searched studies published until June 2023 on several databases using a three-step analysis and categorization of the studies: pre-analysis, exploration of the material, and data processing. RESULTS: We identified 916 studies, 52 of which were included (N = 1,125 participants). Approximately 53.84% of the participants were in the chronic phase, displaying moderate-to-severe functional impairment. Thirty-two studies used RPSS often combining it with task-oriented training, while 20 used rPMS as a standalone intervention. The RPSS primarily targeted the median and ulnar nerves, stimulating for an average of 92.78 min at an intensity that induced paresthesia. RPMS targeted the upper and lower limb paretic muscles, employing a 20 Hz frequency in most studies. The mean stimulation time was 12.74 min, with an intensity of 70% of the maximal stimulator output. Among the 114 variables analyzed in the 52 studies, 88 (77.20%) were in the "s,b" domain, with 26 (22.8%) falling under the "d" domain of the ICF. DISCUSSION AND CONCLUSION: Sensory peripheral neuromodulation protocols hold the potential for enhancing post-stroke motor recovery, yet optimal outcomes were obtained when integrated with intensive or task-oriented motor training.
Assuntos
Recuperação de Função Fisiológica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Reabilitação do Acidente Vascular Cerebral/métodos , Recuperação de Função Fisiológica/fisiologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/fisiopatologia , Terapia por Estimulação Elétrica/métodosRESUMO
Objective: The aim of the present study was to verify the intra- and inter-rater reliability and agreement of the stimulus electrodiagnostic test (SET) measurements obtained by pen and square electrodes in the vastus lateralis and tibialis anterior muscles. Design: An intra- and inter-rater reliability and agreement study was performed for the SET by two independent raters. Two different sizes of cathode electrodes (1 cm2 and 25 cm2) and two muscles were assessed (tibialis anterior and vastus lateralis). Results: Chronaxie did not change according to the different electrodes. A high intra-rater reliability (0.72 ≤ r ≤ 0.88) was detected independently of the electrode and muscle assessed. Moreover, moderate and almost perfect agreements (0.51 ≤ Kappa ≤ 1.00) were detected on intra-rater assessment. Similar correlations (0.74 ≤ r ≤ 0.79) were found for intra-rater reliability. However, dissimilar inter-rater agreement was detected: Kappa ≤ 0.40 for tibialis anterior and Kappa = 1.00 for vastus lateralis. Conclusion: The SET presented high reliability and moderate agreement in intra-rater evaluations. A fair agreement was found in the inter-rater assessment of the tibialis anterior. Evaluations performed with different electrode sizes did not influence the results. Therefore, the SET should be performed by a unique rater in test retest situations.