J Bras Pneumol ; 40(3): 250-8, 2014.
Artigo em Inglês, Português | MEDLINE | ID: mdl-25029648

RESUMO

OBJECTIVE: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. METHODS: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. RESULTS: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). CONCLUSIONS: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples.


Assuntos
Corantes , Escarro/citologia , Adulto , Idoso , Asma/complicações , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doença Pulmonar Obstrutiva Crônica/complicações , Reprodutibilidade dos Testes , Espirometria , Adulto Jovem
2.
J. bras. pneumol ; J. bras. pneumol;40(3): 250-258, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-714689

RESUMO

Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. Results: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). Conclusions: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples. .


Objetivo: Determinar a confiabilidade da coloração hematológica rápida para a análise do escarro induzido. Métodos: Estudo transversal comparando a técnica padrão (coloração May-Grünwald-Giemsa) com a coloração hematológica rápida (panótico rápido). Participaram do estudo 50 indivíduos (21 asmáticos, 19 portadores de DPOC e 10 controles). Após a coleta do escarro induzido, foram preparadas 4 lâminas, sendo 2 coradas por May-Grünwald-Giemsa e 2 por panótico rápido. As lâminas foram lidas de forma independente por dois pesquisadores capacitados para o exame de escarro induzido e cegados para a identificação das lâminas. A confiabilidade para as contagens celulares dos dois métodos foi avaliada pela determinação dos coeficientes de correlação intraclasse (CCI) para as concordâncias intraobservador e interobservador. As concordâncias na identificação de escarro neutrofílico e eosinofílico entre observadores e entre as duas colorações foram calculadas por estatística kappa. Resultados: Nas duas colorações, os CCI apontaram concordância interobservador quase perfeita para as contagens de neutrófilos, eosinófilos e macrófagos (variação do CCI: 0,98-1,00) e substancial para as contagens de linfócitos (variação do CCI: 0,76-0,83). Na análise intraobservador, a concordância foi quase perfeita para as contagens de neutrófilos, eosinófilos e macrófagos (variação do CCI: 0,96-0,99) e de moderada a substancial para as contagens de linfócitos (CCI = 0,65 e 0,75 para observadores 1 e 2, respectivamente). A concordância interobservador na identificação de escarro eosinofílico e neutrofílico para os dois métodos de ...


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Corantes , Escarro/citologia , Asma/complicações , Estudos de Casos e Controles , Estudos Transversais , Variações Dependentes do Observador , Doença Pulmonar Obstrutiva Crônica/complicações , Reprodutibilidade dos Testes , Espirometria