Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 13(27): 31406-31417, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34185501

RESUMO

The use of ultraviolet (UV) and blue irradiation to sterilize surfaces is well established, but commercial applications would be enhanced if the light source is replaced with ambient light. In this paper, it is shown that nanofibers can be explored as an alternative methodology to UV and blue irradiation for bacterial inactivation. It is demonstrated that this is indeed possible using spun nanofibers of poly[lactic-co-(glycolic acid)] (PLGA). This work shows that PLGA spun scaffolds can promote photoinactivation of Staphylococcus aureus and Escherichia coli bacteria with ambient light or with laser irradiation at 630 nm. With the optimized scaffold composition of PLGA85:15 nanofibers, the minimum intensity required to kill the bacteria is much lower than in antimicrobial blue light applications. The enhanced effect introduced by PLGA scaffolds is due to their nanofiber structures since PLGA spun nanofibers were able to inactivate both S. aureus and E. coli bacteria, but cast films had no effect. These findings pave the way for an entirely different method to sterilize surfaces, which is less costly and environmentally friendly than current procedures. In addition, the scaffolds could also be used in cancer treatment with fewer side effects since photosensitizers are not required.


Assuntos
Eletricidade , Escherichia coli/fisiologia , Viabilidade Microbiana/efeitos dos fármacos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/farmacologia , Staphylococcus aureus/fisiologia , Raios Ultravioleta , Escherichia coli/efeitos dos fármacos , Escherichia coli/efeitos da radiação , Viabilidade Microbiana/efeitos da radiação , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/efeitos da radiação
2.
J Phys Chem A ; 120(49): 9702-9706, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27973811

RESUMO

We studied the absorption line-shape of poly(p-phenylenevinylene) (PPV) films deposited via spin coating and Langmuir-Blodgett techniques with the intent of identifying the conjugation length distribution in these two types of films, a key morphological aspect of conjugated polymer films. We treated the excitons in the polymer as independent oligomer excitons and modeled the absorption spectra of the individual oligomers using simple expressions for the oligomer size dependence of the gap energy, the line-broadening factor, the transition dipole moment and the Huang-Rhys parameter. We validated these expressions by independent measurements on phenyl-based oligomers and Density Functional Theory calculations. Our results show clear evidence that, for both types of PPV films, the conjugation length distribution depends exponentially on the segment size. Our results also set a lower limit, of about ten repeat units, for the maximum exciton length of three different phenyl-based oligomers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA