Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 7(33): 29100-29105, 2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36033660

RESUMO

An F-scan nonlinear spectrometer is used to measure the two-photon absorption coefficient for CH3NH3PbBr3 perovskite films from 690 to 995 nm. This spectrometer uses an electrically focused tunable lens and a tunable femtosecond-pulse laser (Mai Tai-HP) with a resolution of 5 nm. Two-band models and saturation irradiance corrections are used to fit the experimental data. The nonlinear absorption in this wavelength range is of the order of cm/MW. We found that the best agreement between the experimental data, the reported values in the literature, and the theoretical model is obtained for an extended two-band model with irradiance saturation correction.

2.
Nanomaterials (Basel) ; 10(8)2020 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-32751330

RESUMO

Recently, the combination of conventional chemical methods for enhanced oil recovery (EOR) and nanotechnology has received lots of attention. This experimental study explores the dynamic changes in the oil configuration due to the addition of nanoparticles (NPs) to biopolymer flooding. The tests were performed in water-wet micromodels using Xanthan Gum and Scleroglucan, and silica-based NPs in a secondary mode. The microfluidic setup was integrated with a microscope to capture the micro-scale fluid configurations. The change in saturation, connectivity, and cluster size distributions of the non-wetting phase was evaluated by means of image analysis. The biopolymer content did not affect the ability of the NPs to reduce the interfacial tension. The experiments showed that the reference nanofluid (NF) flood led to the highest ultimate oil recovery, compared to the Xanthan Gum, Scleroglucan and brine flooding at the same capillary number. In the cases of adding NPs to the biopolymer solutions, NPs-assisted Xanthan flooding achieved the highest ultimate oil recovery. This behavior was also evident at a higher capillary number. The overall finding suggests a more homogenous dispersion of the NPs in the solution and a reduction in the polymer adsorption in the Xanthan Gum/NPs solution, which explains the improvement in the sweep efficiency and recovery factor.

3.
Appl Opt ; 51(11): 1822-7, 2012 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-22505176

RESUMO

In experimental optodigital encrypting architectures, the use of a reference wave is essential. In this contribution, we present an experimental alternative to avoid the reference wave during the encrypting procedure in a joint transform correlator architecture by introducing the concept of a master key. Besides, the master key represents an additional security element for the entire protocol. In our method, the master key is holographically processed and used during the encryption process with the encrypting key. We give the mathematical description for the process in case of a single input object and then we extend it to multiple input objects. We present the experimental demonstration of the proposed method including two examples where this technique is successfully applied for several input objects.

4.
Opt Express ; 20(4): 3388-93, 2012 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-22418097

RESUMO

We present the first experimental technique to encrypt a movie under a joint transform correlator architecture. We also extend the method to multiplex several movies in a single package. We use a Mach-Zehnder interferometer to encrypt experimentally each movie. One arm of the interferometer is the joint transform correlator and the other arm is the reference wave. We include the complete description of the procedure along with experimental results supporting the proposal.

5.
Opt Lett ; 35(3): 333-5, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20125712

RESUMO

We present a method that allows storing multiple encrypted data using digital holography and a joint transform correlator architecture with a controllable angle reference wave. In this method, the information is multiplexed by using a key and a different reference wave angle for each object. In the recovering process, the use of different reference wave angles prevents noise produced by the nonrecovered objects from being superimposed on the recovered object; moreover, the position of the recovered object in the exit plane can be fully controlled. We present the theoretical analysis and the experimental results that show the potential and applicability of the method.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA