Your browser doesn't support javascript.
loading
Nonlinear Two-Photon Absorption in the Near-Infrared Band for Lead Bromide Perovskite Films Using an F-Scan Nonlinear Spectrometer.
Rueda, Edgar; Serna, Juan; Uribe, Jose Ignacio; Ramírez, Daniel; Jaramillo, Franklin; Osorio, Jaime; García, Hernando.
Afiliação
  • Rueda E; Grupo de Óptica y Fotónica, Instituto de Física, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín 050010, Colombia.
  • Serna J; Grupo de Óptica y Espectroscopía, Centro de Ciencia Básica, Universidad Pontifícia Bolivariana, Cq. 1 No 70-01, Campus Laureles, Medellín 050031, Colombia.
  • Uribe JI; Centro de Investigación, Innovación y Desarrollo de Materiales-CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín 050010, Colombia.
  • Ramírez D; Grupo de Estado Sólido, Instituto de Física, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín 050010, Colombia.
  • Jaramillo F; Ingeniush, Institución Universitaria Salazar y Herrera, Medellín 050034, Colombia.
  • Osorio J; Centro de Investigación, Innovación y Desarrollo de Materiales-CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín 050010, Colombia.
  • García H; Centro de Investigación, Innovación y Desarrollo de Materiales-CIDEMAT, Facultad de Ingeniería, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín 050010, Colombia.
ACS Omega ; 7(33): 29100-29105, 2022 Aug 23.
Article em En | MEDLINE | ID: mdl-36033660
An F-scan nonlinear spectrometer is used to measure the two-photon absorption coefficient for CH3NH3PbBr3 perovskite films from 690 to 995 nm. This spectrometer uses an electrically focused tunable lens and a tunable femtosecond-pulse laser (Mai Tai-HP) with a resolution of 5 nm. Two-band models and saturation irradiance corrections are used to fit the experimental data. The nonlinear absorption in this wavelength range is of the order of cm/MW. We found that the best agreement between the experimental data, the reported values in the literature, and the theoretical model is obtained for an extended two-band model with irradiance saturation correction.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Estados Unidos