Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 270: 114040, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38554746

RESUMO

Infants with severe bronchopulmonary dysplasia may require high doses of neurosedative medications to ensure pain control and stability following tracheostomy placement. Subsequent weaning of these medications safely and rapidly is a challenge. We describe a 24-hour propofol infusion to reduce neurosedative medications in 3 high-risk infants following tracheostomy placement.


Assuntos
Displasia Broncopulmonar , Propofol , Traqueostomia , Humanos , Propofol/administração & dosagem , Traqueostomia/métodos , Masculino , Recém-Nascido , Feminino , Lactente , Hipnóticos e Sedativos/administração & dosagem , Infusões Intravenosas , Analgésicos/administração & dosagem , Analgésicos/uso terapêutico , Anestésicos Intravenosos/administração & dosagem , Dor Pós-Operatória/tratamento farmacológico
2.
J Pediatr Pharmacol Ther ; 28(1): 84-92, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36777987

RESUMO

OBJECTIVE: To evaluate the physical intravenous Y-site compatibility of 29 combinations of medications at commonly used pediatric concentrations using both existing and novel techniques. METHODS: Medication combinations included were selected by a varied group of pediatric inpatient pharmacists, and then assessed by 3 independent reviewers for existing literature. For each combination, 2 different medications were mixed together in a 1:1 ratio and incubated at room temperature for 4 hours to simulate Y-site administration. Each sample was then analyzed using the US Pharmacopeia (USP) <788> recommended analytical technique of light obscuration (LO) in addition to novel flow imaging (FI) microscopy and backgrounded membrane imaging (BMI). Physical compatibility was determined using USP chapter <788> large volume particle count limits for all techniques. RESULTS: A total of 29 different medication combinations were studied. Five combinations met criteria for compatibility by all 3 techniques. The remaining 24 combinations reached the threshold to be considered incompatible by at least 1 of the 3 techniques. Light obscuration, BMI, and FI identified 14%, 59%, and 76% of combinations as incompatible, respectively. All samples deemed incompatible by LO were also incompatible by at least 1 of the other 2 techniques. Flow imaging and BMI results agreed in 69% of samples tested. CONCLUSIONS: Most combinations tested were found to be incompatible by at least 1 of the 3 instruments used. Light obscuration appears to have reduced accuracy for identifying particulate resulting in physical medication incompatibility when compared with the novel techniques of FI and BMI.

3.
Am J Health Syst Pharm ; 77(23): 1980-1985, 2020 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-32974650

RESUMO

PURPOSE: To determine the physical intravenous Y-site compatibility of 19 commonly used medications at pediatric concentrations with 3 different types of lipid emulsion. METHODS: Medications at commonly used pediatric concentrations were mixed in a 1:1 ratio with lipid emulsions (Intralipid, Nutrilipid, and Smoflipid) and incubated at room temperature for 4 hours to simulate Y-site administration. Each sample was then diluted with particle-free water and analyzed using the analytical technique of light obscuration recommended in United States Pharmacopeia (USP) general information chapter 729 (USP <729>). Physical compatibility was determined by measuring the percentage of fat residing in globules larger than 5 µm (PFAT5) per USP <729> recommendations. RESULTS: Most combinations tested were physically compatible based on USP <729> regulations. Incompatibilities differed for the different brands of lipid emulsion. The two combinations that met USP <729> criteria for physical incompatibility were cisatracurium 2 mg/mL with Intralipid and gentamicin 2 mg/mL with Smoflipid. CONCLUSION: Three different lipid emulsions were physically compatible at the Y site with the majority of medications tested. Data regarding Y-site compatibility for one lipid emulsion product cannot be safely extrapolated to another without additional testing.


Assuntos
Emulsões Gordurosas Intravenosas/química , Preparações Farmacêuticas/química , Química Farmacêutica , Incompatibilidade de Medicamentos , Emulsões/química , Óleos de Peixe/química , Humanos , Azeite de Oliva/química , Pediatria , Fosfolipídeos/química , Óleo de Soja/química , Triglicerídeos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA