Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Food Sci Anim Resour ; 42(2): 313-320, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35310571

RESUMO

Brazil is considered as a great broiler feet exporter, especially for the Chinese trade. Contact lesions at the tibiotarsal region are responsible for economic losses and there is no model for its classification, thereby this study presents a fast and practical grade system to be used in the poultry industry and proposes these lesion characterizations into three different grades. For this, correlation was made between macroscopic, histological findings and microbiological quantification (Escherichia coli, Staphylococcus spp., Streptococcus spp. and sulphite-reducing clostridia) from contact lesions in the tibiotarsal region of 112 broiler carcasses, divided in four groups (n=28), accordingly to the lesion's intensity. There were no significant differences in microbiological quantification among the groups (p>0.05) except for the grade 3 group, as grade 1 and 2 lesions were in the early stages and histopathological changes such as ulceration were not observed. In grade 3 lesion group, it was observed bacterial cocci grume and ulceration at the articular region and significantly higher microbiological count (p<0.05) for E. coli and Staphylococcus spp. In conclusion, the visual standard proposed in this work, correlated and confirmed by the histopathologic, and microbiologic characterization, allows to precise and fast ascertainment of the contact lesion grade in the tibiotarsal regions of broiler carcasses. Moreover, it should be highlighted that grades 1 and 2 alterations are not caused by an inflammatory process caused by pathogenic agents and should not be considered a public health risk.

2.
J Food Prot ; 76(8): 1330-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23905787

RESUMO

Countries have different official programs and implement different sampling methods for the detection of Salmonella on poultry carcasses. In Brazil, a 25-g sample of skin and muscle excision (SME) from the wings, neck, and pericloacal parts is used; in the European Union (EU), a 25-g sample of neck skin (NSE) is used; and, in the United States, the whole carcass is rinsed with 400 ml of diluent (WCR). In the present study, these methods were evaluated to compare Salmonella occurrence and counts of hygiene indicator microorganisms (Escherichia coli, Enterobacteriaceae, and total viable count of aerobic mesophilic bacteria) using different carcasses from the same flock and also using different analytical units taken from the same carcass. Eighty flocks, with four broiler carcasses from each, were included in this study; three broilers were sampled according to protocols from Brazil, the EU, and the United States, and the last one by all three methods. SME, NSE, and WCR provided equivalent results (P > 0.05) for Salmonella detection on broiler carcasses when using different carcasses from the same flock and when using the same carcass. The predominant serovar was Salmonella Enteritidis. For the enumeration of hygiene indicator microorganisms, WRC provided higher counts than SME or NSE (P < 0.05), when using both the same or different carcasses. Therefore, it is possible to directly compare Salmonella results in poultry carcasses when using the methods recommended by the legislative bodies of Brazil, the United States, and the EU. However, WCR provides the best results for hygiene indicator microorganisms.


Assuntos
Contaminação de Alimentos/análise , Manipulação de Alimentos/métodos , Imersão , Carne/microbiologia , Salmonella/isolamento & purificação , Animais , Brasil , Galinhas/microbiologia , Contagem de Colônia Microbiana/métodos , Enterobacteriaceae/isolamento & purificação , Escherichia coli/isolamento & purificação , União Europeia , Humanos , Higiene , Salmonella enteritidis/isolamento & purificação , Pele/microbiologia , Estados Unidos
3.
Ciênc. rural ; Ciênc. rural (Online);40(7): 1603-1609, jul. 2010. tab
Artigo em Inglês | LILACS | ID: lil-557045

RESUMO

Poultry processing facilities are known for using a great amount of water, which is mainly used on carcasses chilling stage. In Brazil, meat regulations state that each chiller tank must be emptied, cleaned and sanitized every 8 working hours. The aim of the current study was to assess the microbial load of chiller water used in poultry immersion chilling system after 8, 16 and 24 working hours in order to evaluate the reduction of water changes and chiller sanitization. Conventional physicochemical and microbiological assays were done in water supply samples (n=69) to suppress interferences caused by freshwater addition; pre chilled (n=345) post chilled carcasses (n=345) and chiller water samples of the last stage (n=69). The results showed no significant differences on microbial load samples between the three shifts suggesting that the proposed reduction may be secure and reduces the volume of wastewater that would impact the environment, besides improving the rational use of processing time.


As atividades dos estabelecimentos de abate de frangos são conhecidas por utilizarem grandes volumes de água durante seus processos, principalmente no processo de resfriamento das carcaças de frangos. Parte desse volume utilizado se faz necessário, em cumprimento à legislação que determina que cada tanque do sistema de pré-resfriadores contínuos por imersão deve ser completamente esvaziado, limpo e desinfetado no final de cada período de trabalho (oito horas). O objetivo deste estudo foi comparar a carga microbiana das águas do sistema de resfriamento e das carcaças de frango ao final de oito, dezesseis e vinte e quatro horas de trabalho do abatedouro, para possível redução do número de vezes do completo esvaziamento dos tanques do sistema de resfriamento. Foram avaliadas, por meio de métodos convencionais microbiológicos e físico-químicos, amostras da água de abastecimento (n=69), visando a evitar possível interferência nas contagens das águas do sistema de resfriamento, amostras de carcaças de frango antes (n=345) e após (n=345) sua passagem pelo sistema de resfriamento e amostras de águas do último estágio do sistema de resfriamento de carcaças (n=69). Os resultados obtidos demonstraram que não houve diferença significativa na carga microbiana das amostras entre as três jornadas de trabalho do estabelecimento, sugerindo que a redução é segura, diminuindo assim o volume de águas residuais e seu impacto no meio ambiente, bem como melhorando o uso racional do tempo de processamento.

4.
Ci. Rural ; 40(7)2010.
Artigo em Inglês | VETINDEX | ID: vti-707005

RESUMO

Poultry processing facilities are known for using a great amount of water, which is mainly used on carcasses chilling stage. In Brazil, meat regulations state that each chiller tank must be emptied, cleaned and sanitized every 8 working hours. The aim of the current study was to assess the microbial load of chiller water used in poultry immersion chilling system after 8, 16 and 24 working hours in order to evaluate the reduction of water changes and chiller sanitization. Conventional physicochemical and microbiological assays were done in water supply samples (n=69) to suppress interferences caused by freshwater addition; pre chilled (n=345) post chilled carcasses (n=345) and chiller water samples of the last stage (n=69). The results showed no significant differences on microbial load samples between the three shifts suggesting that the proposed reduction may be secure and reduces the volume of wastewater that would impact the environment, besides improving the rational use of processing time.


As atividades dos estabelecimentos de abate de frangos são conhecidas por utilizarem grandes volumes de água durante seus processos, principalmente no processo de resfriamento das carcaças de frangos. Parte desse volume utilizado se faz necessário, em cumprimento à legislação que determina que cada tanque do sistema de pré-resfriadores contínuos por imersão deve ser completamente esvaziado, limpo e desinfetado no final de cada período de trabalho (oito horas). O objetivo deste estudo foi comparar a carga microbiana das águas do sistema de resfriamento e das carcaças de frango ao final de oito, dezesseis e vinte e quatro horas de trabalho do abatedouro, para possível redução do número de vezes do completo esvaziamento dos tanques do sistema de resfriamento. Foram avaliadas, por meio de métodos convencionais microbiológicos e físico-químicos, amostras da água de abastecimento (n=69), visando a evitar possível interferência nas contagens das águas do sistema de resfriamento, amostras de carcaças de frango antes (n=345) e após (n=345) sua passagem pelo sistema de resfriamento e amostras de águas do último estágio do sistema de resfriamento de carcaças (n=69). Os resultados obtidos demonstraram que não houve diferença significativa na carga microbiana das amostras entre as três jornadas de trabalho do estabelecimento, sugerindo que a redução é segura, diminuindo assim o volume de águas residuais e seu impacto no meio ambiente, bem como melhorando o uso racional do tempo de processamento.

5.
Ci. Rural ; 40(7)2010.
Artigo em Inglês | VETINDEX | ID: vti-706716

RESUMO

Poultry processing facilities are known for using a great amount of water, which is mainly used on carcasses chilling stage. In Brazil, meat regulations state that each chiller tank must be emptied, cleaned and sanitized every 8 working hours. The aim of the current study was to assess the microbial load of chiller water used in poultry immersion chilling system after 8, 16 and 24 working hours in order to evaluate the reduction of water changes and chiller sanitization. Conventional physicochemical and microbiological assays were done in water supply samples (n=69) to suppress interferences caused by freshwater addition; pre chilled (n=345) post chilled carcasses (n=345) and chiller water samples of the last stage (n=69). The results showed no significant differences on microbial load samples between the three shifts suggesting that the proposed reduction may be secure and reduces the volume of wastewater that would impact the environment, besides improving the rational use of processing time.


As atividades dos estabelecimentos de abate de frangos são conhecidas por utilizarem grandes volumes de água durante seus processos, principalmente no processo de resfriamento das carcaças de frangos. Parte desse volume utilizado se faz necessário, em cumprimento à legislação que determina que cada tanque do sistema de pré-resfriadores contínuos por imersão deve ser completamente esvaziado, limpo e desinfetado no final de cada período de trabalho (oito horas). O objetivo deste estudo foi comparar a carga microbiana das águas do sistema de resfriamento e das carcaças de frango ao final de oito, dezesseis e vinte e quatro horas de trabalho do abatedouro, para possível redução do número de vezes do completo esvaziamento dos tanques do sistema de resfriamento. Foram avaliadas, por meio de métodos convencionais microbiológicos e físico-químicos, amostras da água de abastecimento (n=69), visando a evitar possível interferência nas contagens das águas do sistema de resfriamento, amostras de carcaças de frango antes (n=345) e após (n=345) sua passagem pelo sistema de resfriamento e amostras de águas do último estágio do sistema de resfriamento de carcaças (n=69). Os resultados obtidos demonstraram que não houve diferença significativa na carga microbiana das amostras entre as três jornadas de trabalho do estabelecimento, sugerindo que a redução é segura, diminuindo assim o volume de águas residuais e seu impacto no meio ambiente, bem como melhorando o uso racional do tempo de processamento.

6.
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1478256

RESUMO

Poultry processing facilities are known for using a great amount of water, which is mainly used on carcasses chilling stage. In Brazil, meat regulations state that each chiller tank must be emptied, cleaned and sanitized every 8 working hours. The aim of the current study was to assess the microbial load of chiller water used in poultry immersion chilling system after 8, 16 and 24 working hours in order to evaluate the reduction of water changes and chiller sanitization. Conventional physicochemical and microbiological assays were done in water supply samples (n=69) to suppress interferences caused by freshwater addition; pre chilled (n=345) post chilled carcasses (n=345) and chiller water samples of the last stage (n=69). The results showed no significant differences on microbial load samples between the three shifts suggesting that the proposed reduction may be secure and reduces the volume of wastewater that would impact the environment, besides improving the rational use of processing time.


As atividades dos estabelecimentos de abate de frangos são conhecidas por utilizarem grandes volumes de água durante seus processos, principalmente no processo de resfriamento das carcaças de frangos. Parte desse volume utilizado se faz necessário, em cumprimento à legislação que determina que cada tanque do sistema de pré-resfriadores contínuos por imersão deve ser completamente esvaziado, limpo e desinfetado no final de cada período de trabalho (oito horas). O objetivo deste estudo foi comparar a carga microbiana das águas do sistema de resfriamento e das carcaças de frango ao final de oito, dezesseis e vinte e quatro horas de trabalho do abatedouro, para possível redução do número de vezes do completo esvaziamento dos tanques do sistema de resfriamento. Foram avaliadas, por meio de métodos convencionais microbiológicos e físico-químicos, amostras da água de abastecimento (n=69), visando a evitar possível interferência nas contagens das águas do sistema de resfriamento, amostras de carcaças de frango antes (n=345) e após (n=345) sua passagem pelo sistema de resfriamento e amostras de águas do último estágio do sistema de resfriamento de carcaças (n=69). Os resultados obtidos demonstraram que não houve diferença significativa na carga microbiana das amostras entre as três jornadas de trabalho do estabelecimento, sugerindo que a redução é segura, diminuindo assim o volume de águas residuais e seu impacto no meio ambiente, bem como melhorando o uso racional do tempo de processamento.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA