Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 16(3): 271-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27621547

RESUMO

BACKGROUND: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. PURPOSE: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). MATERIALS AND METHODS: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. RESULTS: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens' failure modes were cohesive. CONCLUSIONS: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages.

2.
Full dent. sci ; 7(25): 64-69, jan.2016. tab
Artigo em Português | LILACS | ID: lil-790080

RESUMO

O objetivo deste estudo foi avaliar a correlação entre as cores nomeadas com identificações iguais de dentes artificiais de resina acrílica de diferentes marcas comerciais. Foram selecionadas cinco marcas: Vipi Dent Plus (VIPI), Biolux OMC (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás) e Tritone (VIPI), todas utilizando o mesmo padrão de nomenclatura. De cada marca comercial foram utilizadas as cores: 60, 62, 65, 66, 67 e 69. Para realizar as comparações de cor foi utilizado o aparelho espectrofotômetro Vita Easy Shade. Após três medições de cada cor, foi obtida a média das leituras, todas realizadas no centro do dente, no mesmo horário e com fundo cinza claro padronizado. Assim, os valores de L*, a* e b* foram obtidos. Esses valores foram tabulados para cálculos do ∆E, onde ∆E< ou = 3 representa diferença de cor significativa e perceptível. Observou-se correlação entre as marcas comerciais na cor 60 Biocler GII e Natus Dent (ΔE= 3); Biocler GII e Tritone (ΔE= 2,87), cor 62 Biolux OMC e Natus Dent (ΔE=1,33), cor 67 Natus Dent e Tritone (ΔE=2,06) e Tritone e Vipi Dent Plus (ΔE=1,92). Concluiu-se que os resultados demonstraram poucas correlações entre as marcas avaliadas e as correlações existentes não ocorreram de forma igual para todas as cores, dificultando o sucesso dos tratamentos protéticos, assim como a comunicação entre o cirurgião dentista e o técnico em prótese dentária...


The objective of this study was to evaluate the correlation between colors of artificial acrylic resin teeth from different brands with the same name and identification. Five brands were selected: Vipi Dent Plus (VIPI), Biolux WTO (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás), and Tritone (VIPI), all using the same naming pattern. The used colors from each brand were: 60, 62, 65, 66, 67, and 69. To perform comparisons of color the Vita Easy Shade spectrophotometer was used. After three measurements of each color a mean was obtained All readings were performed on the central area of the tooth, at the same time and with clear standard gray background, obtaining the values of L*, a*, and b*. These values were tabulated for ΔE calculations, where ΔE < or = 3 represented significant and noticeable color difference. There is a correlation between the trademarks in color 60 Biocler GII and Natus Dent (ΔE = 3); Biocler GII and Tritone (ΔE = 2.87), color 62 Biolux WTO and Natus Dent (ΔE = 1.33), color 67 Natus Dent and Tritone (ΔE = 2.06), and Tritone and Vipi Dent Plus (ΔE = 1, 92). It was concluded that the results showed little correlation between the evaluated brands and correlation did not occur equally to all colors, hindering the success of prosthetic treatments as well as communication between the dental surgeon and dental technician...


Assuntos
Humanos , Espectrofotômetros/métodos , Prótese Dentária , Resinas Compostas/química , Dente Artificial , Cor
3.
Rev. bras. pesqui. saúde ; 16(2): 15-21, abr.-jun.2014.
Artigo em Português | LILACS | ID: lil-783336

RESUMO

Fraturas de dentes artificiais de bases de próteses dentárias são problemas comuns. Objetivo: O propósito deste estudo foi avaliar a resistência da união ao cisalhamento de três marcas comerciais de dentes artificiais (Biolux® [B]; Vip Dent® [V]; Trybite® [T]) com e sem retenção mecânica a uma resina acrílica termopolimerizável (Vip Cril). Métodos: Dentes artificiais foram fixados com cera em 60 cilindros de PVC. A seguir, foram incluídos em mufla odontológica com gesso especial e, após a eliminação da cera os 60 cilindros, foram divididos em dois grupos experimentais com (CR=30) e sem (SR=30) retenção mecânica, destes ainda foram criados subgrupos (n=10) para cada marca de dente. Os corpos de prova, depois de preenchidos com a resina acrílica, polimerização, desinclusão e acabamento, foram armazenados em água destilada a 37°C por 24 horas e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min). Falhas foram analisadas em lupa (40 X). Resultados: A análise de variância não evidenciou diferença estatisticamente significante (P > 0,05) entre os grupos com ou sem retenção mecânica. O teste de Tukey (α = 0,05) evidenciou diferença significante (P < 0,001) entre as marcas: (T = 20,3 MPa; V = 17,8 MPa e B = 15,5 MPa). As falhas foram predominantemente mistas. Conclusão: A retenção mecânica não aumentou a resistência de união e as diferentes marcas de dentes podem influenciar na união...


Assuntos
Humanos , Dente Artificial , Prótese Dentária , Resinas Acrílicas
4.
J. appl. oral sci ; J. appl. oral sci;21(6): 590-596, Nov-Dec/2013. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-697822

RESUMO

Objective: This study evaluated the effect of three metal conditioners on the shear bond strength (SBS) of a prosthetic composite material to cpTi grade I having three surface treatments. Material and Methods: One hundred sixty eight rivet-shaped specimens (8.0x2.0 mm) were cast and subjected to polishing (P) or sandblasting with either 50 mm (50SB) or 250 mm (250SB) Al2O3. The metal conditioners Metal Photo Primer (MPP), Cesead II Opaque Primer (OP), Targis Link (TL), and one surface modification system Siloc (S), were applied to the specimen surfaces, which were covered with four 1-mm thick layers of resin composite. The resin layers were exposed to curing light for 90 s separately. Seven specimens from each experimental group were stored in water at 37ºC for 24 h while the other 7 specimens were subjected to 5,000 thermal cycles consisting of water baths at 4ºC and 60ºC (n=7). All specimens were subjected to SBS test (0.5 mm/min) until failure occurred, and further 28 specimens were analyzed using scanning electron microscope (SEM) and X-ray energy-dispersive spectroscopy (EDS). Data were analyzed by 3-way ANOVA followed by post-hoc Tukey's test (α=0.05). Results: On 50SB surfaces, OP groups showed higher SBS means than MPP (P<0.05), while no significant difference was found among OP, S, and TL groups. On 250SB surfaces, OP and TL groups exhibited higher SBS than MPP and S (P<0.05). No significant difference in SBS was found between OP and TL groups nor between MPP and S groups. The use of conditioners on 250SB surfaces resulted in higher SBS means than the use of the same products on 50SB surfaces (P<0.05). Conclusion: Sandblasting associated with the use of metal conditioners improves SBS of resin composites to cpTi. .


Assuntos
Resinas Compostas/química , Ligas Dentárias/química , Colagem Dentária/métodos , Metacrilatos/química , Resistência ao Cisalhamento/efeitos dos fármacos , Titânio/química , Análise de Variância , Cimentos Dentários/química , Falha de Restauração Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos , Valores de Referência , Silanos/química , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
5.
Full dent. sci ; 4(16): 526-531, out. 2013. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-695723

RESUMO

Com o sucesso da osseointegração, um dos obstáculos para o êxito das reabilitações sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos, porém ainda não está claro quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que desadaptações protéticas podem provocar problemas biomecânicos. O presente estudo teve como objetivo analisar e comparar a adaptação marginal vertical de seis diferentes marcas comerciais de pilares calcináveis antes da fundição a um implante hexágono externo de plataforma regular. Para tanto, os pilares foram divididos em sete grupos experimentais (n=5), sendo seis deles pilares totalmente calcináveis e um grupo controle com base pré-fabricada de Co-Cr. Os pilares foram fixados ao implante por meio de um parafuso da respectiva marca e receberam um torque de 10 Ncm com auxílio de um torquímetro manual. Em seguida as desadaptações foram analisadas em microscópio ótico em seis diferentes pontos, que resultaram em uma média, a qual foi submetida à análise estatística de variância (ANOVA) e aplicado o teste de Tukey (5%) para diferenciação. Os resultados mostraram valores médios para os grupos de 1,54µm (G I); 1,64µm (G II); 1,78µm (G III); 1,76µm (G IV); 1,78µm (G V); 1,46µm (G VI) e 1,18µm (GC), não sendo diferentes estatisticamente, exceto para o grupo controle. Dentro das limitações deste estudo, pode-se concluir que todas as marcas comerciais de cilindros calcináveis analisadas tiveram o mesmo padrão de precisão de adaptação e o com base metálica pré-fabricada apresentou melhor adaptação.


After the success of osseointegration, one of the obstacles to the success of implant restorations is to obtain good marginal fit of prosthetic components. However it is unclear what levels of misfit are considered clinically acceptable, but it is known that prosthetic misfit can cause biomechanical problems. This study aimed to analyze and compare the vertical misfit of six different brands of cast abutments of the external hexagon implant regular platform before casting. Therefore the abutments were divided into seven groups (n=5), six of them fully cast abutments and a control group with prefabricated Co-Cr base. The abutments were attached to the implant by a screw of the same brand, and received a torque of 10Ncm with the aid of a manual torque wrench. After the misfits were analyzed by optical microscopy at six different points, which resulted in an average submitted to statistical analysis of variance (ANOVA), and the test of Tukey (5%) was applied for differentiation. The results showed average values of 1.54µm (G I); 1.64µm (G II); 1.78µm (G III); 1.76µm (G IV); 1.78µm (G V); 1.46µm (G VI); 1.18µm (GC), and no statistically difference was observed except for the control group. Within the limitations of this study, it can be concluded that all the brands of cast abutments analyzed had the same standard of accuracy and adaptation and those with pre-fabricated metal base showed better adaptation.


Assuntos
Prótese Dentária Fixada por Implante , Implantação Dentária , Materiais Dentários/análise , Análise de Variância
6.
J Appl Oral Sci ; 21(6): 590-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24473727

RESUMO

OBJECTIVE: This study evaluated the effect of three metal conditioners on the shear bond strength (SBS) of a prosthetic composite material to cpTi grade I having three surface treatments. MATERIAL AND METHODS: One hundred sixty eight rivet-shaped specimens (8.0x2.0 mm) were cast and subjected to polishing (P) or sandblasting with either 50 mm (50SB) or 250 mm (250SB) Al2O3. The metal conditioners Metal Photo Primer (MPP), Cesead II Opaque Primer (OP), Targis Link (TL), and one surface modification system Siloc (S), were applied to the specimen surfaces, which were covered with four 1-mm thick layers of resin composite. The resin layers were exposed to curing light for 90 s separately. Seven specimens from each experimental group were stored in water at 37ºC for 24 h while the other 7 specimens were subjected to 5,000 thermal cycles consisting of water baths at 4ºC and 60ºC (n=7). All specimens were subjected to SBS test (0.5 mm/min) until failure occurred, and further 28 specimens were analyzed using scanning electron microscope (SEM) and X-ray energy-dispersive spectroscopy (EDS). Data were analyzed by 3-way ANOVA followed by post-hoc Tukey's test (α=0.05). RESULTS: On 50SB surfaces, OP groups showed higher SBS means than MPP (P<0.05), while no significant difference was found among OP, S, and TL groups. On 250SB surfaces, OP and TL groups exhibited higher SBS than MPP and S (P<0.05). No significant difference in SBS was found between OP and TL groups nor between MPP and S groups. The use of conditioners on 250SB surfaces resulted in higher SBS means than the use of the same products on 50SB surfaces (P<0.05). CONCLUSION: Sandblasting associated with the use of metal conditioners improves SBS of resin composites to cpTi.


Assuntos
Resinas Compostas/química , Ligas Dentárias/química , Colagem Dentária/métodos , Metacrilatos/química , Resistência ao Cisalhamento/efeitos dos fármacos , Titânio/química , Análise de Variância , Cimentos Dentários/química , Falha de Restauração Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos , Valores de Referência , Silanos/química , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
7.
J Prosthodont ; 18(8): 663-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19523025

RESUMO

PURPOSE: This study evaluated the effect of three metal conditioners [Metal Photo Primer (MPP), Cesead II Opaque Primer (OP), Targis Link (TL)], and one surface modification system [Siloc (S)] on the shear bond strength (SBS) of a prosthetic composite material to Ni-Cr alloy. MATERIALS AND METHODS: Rivet-shaped specimens were cast, and three surface treatments were evaluated: Polishing (P); sandblasting with either 50 microm (50SB) or 250 microm (250SB) Al(2)O(3). All products were applied to half of the specimens, while the other half remained without the materials. Veneering resin composite (8-mm diameter, 2-mm thick) was applied and light-exposed for 90 seconds in a laboratory light-curing unit. The specimens were stored in water at 37 degrees C for 24 hours, and half were subjected to 500 thermal cycles consisting of water baths at 4 degrees C and 60 degrees C. All specimens were submitted to SBS test (0.5 mm/min) until failure. Failure patterns were determined using optical and scanning electron microscope (SEM) analysis. Data were analyzed by ANOVA and post hoc Tukey's test (preset alpha of 5%). RESULTS: The SBS values of OP and TL groups were higher than those of MPP and S within the 50SB treatment (p < 0.05). No significant difference in SBS was noted between OP and TL as well as between MPP and S. On the other hand, no significant differences were found among conditioners within the 250SB group (p > 0.05). The SBS values of MPP, OP, and S from the 250SB group were higher than those from 50SB (p < 0.05). No significant difference in SBS was noted among most groups with conditioners after thermocycling. The only exception was observed for MPP, which showed an increase in SBS after thermocycling (p < 0.05). Differences in SBS were noted among the groups with conditioners (p < 0.05), and no significant difference in SBS was noted between TL and OP groups, which showed the highest values among all within the P group. No significant difference was noted between MPP and S. Debonded surfaces showed adhesive failures predominantly located between metal surface and opaque resin. CONCLUSIONS: The OP and TL conditioners and surface sandblasting with 250 microm Al(2)O(3) promoted the highest SBS between resin and the Ni-Cr metal surface.


Assuntos
Ligas de Cromo/química , Resinas Compostas/química , Colagem Dentária , Corrosão Dentária/métodos , Materiais Dentários/química , Níquel/química , Acrilatos/química , Óxido de Alumínio/química , Compostos Inorgânicos de Carbono/química , Cimentos Dentários/química , Polimento Dentário , Facetas Dentárias , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Silanos/química , Cimento de Silicato/química , Compostos de Silício/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Ácidos Tricarboxílicos/química , Água/química
8.
Artigo em Português | LILACS-Express | LILACS | ID: lil-536727

RESUMO

doenças como estomatite protética, cáries e doenças periodontais nos usuários de próteses removíveis parciaise totais. As características da placa microbiana presente nas próteses podem ser influenciadas porfatores relacionados ao paciente, como idade, sexo, condições sistêmicas, qualidade da microbiota bucal euso de medicamentos e por fatores relacionados à prótese como condições de estado (suporte, retenção eestabilidade), tempo de utilização, métodos de higienização, propriedades físico-químicas da resina acrílicautilizada para a confecção da base e técnicas de confecção e polimento da prótese. Este estudo tem por objetivodiscutir, por meio de uma revisão de literatura, os fatores associados à aderência de microrganismosaos materiais utilizados para a confecção de base de próteses


The adherence of microorganisms on denture base materials may help determine the development of diseasessuch as denture stomatitis, caries e periodontal diseases in complete and partial denture users. Thefeatures of the denture plaque may be influenced by factors related to the patient such as gender, age, systemicconditions, quality of oral environment and use of medication, and factors related to denture suchas conditions of support, retention, and stability, denture age, hygiene practices, chemical and physicalproperties of denture base resin and techniques for fabrication and polishing denture bases. This studyaimed to discuss, by a literature review, the factors related to the adherence of microorganisms on thedenture base materials

9.
Rev. dental press estét ; 5(4): 67-74, out.-dez. 2008. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-543705

RESUMO

Estudos comprovam que o sistema Procera (Nobel Biocare) é uma das maiores evoluções em restaurações livres de metal. Esse sistema utiliza a tecnologia CAD-CAM para a confecção de uma infra-estrutura altamente resistente e estética por meio da digitalização do troquel utilizando-se um scanner. No sistema Procera, a base cerâmica é construida em espessuras padronizadas de 0,4 ou 0,6mm, levando, consequentemente, a diferenças na espessura da cerâmica de cobertura. Essas alterações na forma ou espessura do contorno cerâmico atuam como regiões suscetíveis ao aumento de tensões, tornando a restauração mais sensível a falhas. Visando utilizar o sistema Procera em preparos com desgastes excessivos, uma técnica de duplo escaneamento foi desenvolvida. Objetiva-se, com esse relato de caso, a descrição da técnica do duplo escaneamento no sistema Procera como uma alternativa na confecção de infra-estruturas para restaurações livres de metal.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Cerâmica , Resinas Compostas , Restauração Dentária Permanente , Desenho Assistido por Computador , Estética Dentária , Sorriso/psicologia
11.
Rev. odontol. Univ. St. Amaro ; 10(1): 35-38, jan.-jun. 2005. graf
Artigo em Português | BBO - Odontologia | ID: biblio-858492

RESUMO

O objetivo deste estudo foi avaliar a resistência de união da porcelana (Dulceram) às liga Co-Cr (Vera PDI) e Ni-Cr (Vera Bond 11). Estruturas metálicas circulares foram usinadas, jateadas (A1203 - aam), e as porcelanas (opaco e corpo) aplicadas. Antes da aplicação do opaco na liga de Co-Cr, foi utiliza< agente de união (Chrome cobalt bonding agent). Os corpos-de-prova foram submetidos aos ensaios mecân de cisalhamento, e os resultados obtidos foram analisados estatisticamente, não mostrando diferel significativas (p>O,05) entre os valores de tensão de cisalhamento para as ligas de Ni-Cr (26,85 MPa) e Ce (24,76 MPa).


Assuntos
Prótese Parcial Fixa , Ligas Metalo-Cerâmicas , Resistência ao Cisalhamento
12.
Araraquara; s.n; 2004. 215 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-466907

RESUMO

Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S)aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3 foram obtidos três grupos experimentais para cada metal: Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 50 um e Grupo (J250), jateado com Al2O3 de 250um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250...


Assuntos
Resinas Compostas , Ligas Dentárias , Facetas Dentárias , Prótese Parcial Fixa , Titânio
13.
J Dent ; 31(3): 205-11, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12726705

RESUMO

OBJECTIVES: This study was undertaken to evaluate the shear bond strength of four materials used as aesthetic material bonded to Ni-Cr alloy. METHODS: Sixty-eight alloy discs were prepared and divided equally into four groups, and received four treatments for veneering: conventional feldspathic porcelain (Noritake EX-3) and three light-cured prosthodontic composite resins (Artglass, Solidex and Targis). The aesthetic materials were applied after metal structure conditioning in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37 degrees C for 7 days. A universal testing machine was used to measure the shear bond strength of the specimens at a cross head speed of 0.5 mm/min. Fractured specimens were examined by using both optical and scanning electron microscope. RESULTS: The analysis of variance and Tukey's test showed that the strongest mean shear bond was obtained with Noritake EX-3 (mean shear bond strength 42.90+/-7.82 MPa). For composites, the highest mean shear bond strength was observed for Targis (12.30+/-1.57 MPa); followed by Solidex (11.94+/-1.04 MPa) and Artglass (10.04+/-0.75 MPa). Optical analysis of the fractured surfaces indicated that for Targis and Noritake EX-3 all failures were a mixture of both cohesive and adhesive patterns. As for Artglass and Solidex, the fractures were mainly adhesive in nature. CONCLUSIONS: The Solidex system was equivalent to the Targis system in bond strength and exhibited greater strength than the Artglass system. The porcelain fused-to-metal showed considerably higher shear bond strength than the three metal-resin bonding techniques.


Assuntos
Ligas de Cromo , Resinas Compostas , Colagem Dentária , Porcelana Dentária , Ligas Metalo-Cerâmicas , Análise do Estresse Dentário , Teste de Materiais , Níquel , Resistência ao Cisalhamento
14.
JBA, J. Bras. ATM Oclusão Dor Orofac ; 2(8): 340-3, out.-dez. 2002. CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-851466

RESUMO

Devido à complexidade dos fatores responsáveis pelo desencadeamento das disfunções craniomandibulares e à dificuldade de se identificarem seus fatores etiológicos, a terapia por placas oclusais tem sido um dos primeiros recursos e, na maioria das vezes, o único tratamento proposto aos pacientes. A todo paciente deverá ser aplicado um programa individualizado de tratamento que poderá englobar a terapia por placas oclusais, a fisioterapia, a farmacologia, a psicoterapia, um simples aconselhamento ou até mesmo o ajuste oclusal por desgaste seletivo ou cirurgias. Assim, este artigo tem por objetivo discutir os mecanismos de funcionamento das placas oclusais para que seu uso possa ser mais efetivo


Assuntos
Transtornos Craniomandibulares/terapia , Placas Oclusais
15.
Pós-Grad. Rev ; 5(1): 58-63, jan.-abr. 2002. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-854088

RESUMO

Diferentes materiais estéticos e sistemas de união têm sido desenvolvidos com o objetivo de reduzir a infiltração marginal na interface resina-metal de coroas. O presente estudo avaliou esse fenômeno utilizando-se corpos-de-prova confeccionados com três diferentes resinas e uma liga de Ni-Cr. Após sua confecção foram armazenados em água destilada a 37ºC por 24 horas e, em seguida, submetidos a 100 ciclos alternados em água nos respectivos tempos e temperaturas: 15 segundos a 60 ± 2ºC e 15 segundos a 12 ± 2ºC. Após essa etapa foram colocados em solução aquosa de Rodamina B a 0,2 por cento por 24 horas. Posteriormente, foram seccionados em 4 setores expondo-se as áreas infiltradas, que foram avaliadas em um perfilômetro. A vista dos resultados obtidos e de acordo com a metodologia empregada, concluiu-se que: ocorreu microinfiltração em todas as situações; a maior infiltração ocorreu com o material SR-Chromasit


Assuntos
Resinas Compostas , Infiltração Dentária , Materiais Dentários , Facetas Dentárias , Prótese Parcial Fixa
16.
Araraquara; s.n; 2000. 208 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-864010

RESUMO

O objetivo deste estudo foi avaliar a resistência da união de quatro materiais utilizados como revestimento estético de próteses fixas à uma liga de Ni-Cr. Para tanto, foram construidas 68 estruturas metálicas circulares e divididas em quatro grupos para cada material a ser testado: porcelana feldspática convencional (Noritake EX-3) e três resinas compostas laboratoriais (sistema Artglass, Solidex e Targis) com seus respectivos agentes de união (Siloc Pre e Siloc Bond, Metal Photo Primer e Targis Link), que foram aplicados de acordo com as instruções dos fabricantes. Em seguida, os corpos-de-prova foram armazenados em água destilada a 37º C por 7 dias e, após, submetidos aos ensaios mecânicos de cisalhamento em máquina de ensaios universal com velocidade de 0,5 mm/min. Os tipos de falhas foram também avaliados macro e microscopicamente. Os resultados obtidos foram analisados estatisticamente, permitindo as seguintes conclusões: (1) a resistência da união metal-porcelana, utilizada como parâmetro de qualidade, foi superior em relação à das resinas estudadas; (2) os sistemas Solidex e Targis apresentaram resistências de união resina-metal semelhantes entre si e superiores a do sistema Artglass; (3) para os sistemas Targis e Noritake EX-3, as falhas foram predominantemente mistas, enquanto para os sistemas Solidex e Artglas as falhas foram predominantemente adesivas


The purpose of this study was to evaluate the shear bond strength of four materials used as esthetic material associated to Ni-Cr alloy. Sixth eight alloy discs were prepared and divided equally into four groups and received four treatments for bonding systems: conventional feldspatic porcelain (Noritake EX-3) and three adhesive bonding promoter (Siloc Pre and Siloc Bond - Artglass, Metal Photo Primer- Solidex and Targis Link - Targis) of a light-cured prosthodontic composite resin to metal. The esthetic materials were applied after metal structure conditioning in accordance with the manufacturers' recommendations. Specimens were stored in distilled water at 37º C for 7 days. An universal testing machine was used to measure the shear bond strength of the specimens at a cross head speed of 0.5 mm/min. Fractured specimens were examined by using both optical and scanning electron microscope. The results were statistically analyze and it was concluded that: (1) the porcelain fused-to-metal bonding method showed significantly higher shear bond strength than the metal-resin bonding techniques; (2) the system Solidex was equivalent to system Targis in bond strength and exhibited greater strength than the system Artglass; (3) optical analysis of the fracture surfaces indicated that for Targis and Noritake EX-3 all failures were a mixture of both cohesive and adhesive patterns. Artglass and Solidex the fractures were mainly adhesive in nature


Assuntos
Resistência ao Cisalhamento , Facetas Dentárias , Ligas de Cromo , Prótese Parcial Fixa , Resinas Compostas , Estética Dentária
17.
JBC j. bras. clin. estet. odontol ; 3(13): 72-6, jan.-fev. 1999.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-296616

RESUMO

Através de revisäo da literatura, procurou-se esclarecer qual a relaçäo entre bacteremias transitórias induzidas por procedimentos odontológicos e a infecçäo de próteses articulares. O uso ou näo da profilaxia antibiótica nesses pacientes é controverso, näo definido cientificamente e näo avalizado por nenhuma associaçäo médica. Sugere-se que, para qualquer paciente, seja realizada uma anamnese criteriosa e dirigida, bem como o indispensável contato com o médico ortopedista. Näo sendo possível o contato, e optando-se pela profilaxia, as cefalosporinas de primeira geraçäo (2 g oralmente 1 hora antes do procedimento) ou a clindamicina para pacientes alérgicos (600 mg oralmente 1 hora antes do procedimento) podem ser indicadas juntamente com bochechos de uma soluçäo de clorexidina 0,12 por cento antes da intervençäo


Assuntos
Antibioticoprofilaxia , Bacteriemia , Padrões de Prática Odontológica , Assistência Odontológica para a Pessoa com Deficiência , Prótese Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA