Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.713
Filtrar
1.
Luminescence ; 39(9): e4890, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39234919

RESUMEN

Three dyes-diesters of monoimides of perylene-3,4,9,10-tetracarboxylic acid were synthesized in three-stage process: esterification, hydrolysis, and monoimidation as potential fluorescent light-stable colorants for high visibility safety wear. The structure of these compounds was confirmed by 1H nuclear magnetic resonance spectroscopy and mass spectrometry, and their spectroscopic and physicochemical properties were determined. Colorants were applied to dyeing polyester fibre and polystyrene and poly (methyl methacrylate) films. The light, wash, and rubbing fastness of the dyeings were determined, and chromaticity coordinates were measured and discussed.


Asunto(s)
Perileno , Poliésteres , Polimetil Metacrilato , Poliestirenos , Poliestirenos/química , Poliestirenos/síntesis química , Perileno/química , Perileno/síntesis química , Perileno/análogos & derivados , Poliésteres/química , Poliésteres/síntesis química , Polimetil Metacrilato/química , Polimetil Metacrilato/síntesis química , Estructura Molecular , Ésteres/química , Imidas/química , Imidas/síntesis química , Colorantes/química , Colorantes/síntesis química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química
2.
BMC Oral Health ; 24(1): 1081, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39272090

RESUMEN

BACKGROUND: Decreased salivary flow can make the patients uncomfortable with their complete dentures and affects the retention of the dentures. Milling and 3D printing have become an alternative to conventional denture construction techniques. The goal of this study was to evaluate the effect of conventional and digital techniques of the complete denture construction on the denture surface wettability with distilled water and saliva substitute before and after thermocycling. METHODS: A total of 30 specimens were utilized in the present study. Specimens were divided according to the construction techniques into 3 groups (n = 10 each). Group I: Heat-polymerized polymethylmethacrylate (PMMA) group, group II: Milled group, and group III: 3-dimensional (3D)-printed group. All the specimens were subjected to 2000 cycles of thermal aging in a thermocycler. The wettability of all specimens to water and saliva substitute was measured via a contact angle goniometer (Olympus TGHM, Rame-hart Inc, USA) before and after thermocycling. Descriptive statistical analysis, plots, and the Shapiro-Wilk test were used to verify normality for each variable. One-way ANOVA was used to compare the 3 study groups, while paired samples t-test was used to compare the differences within each group (P < .05). RESULTS: The smallest contact angle of drop of water to the denture base specimens before and after thermocycling were recorded in the milled group (53.0 ± 4.77 and 50.27 ± 2.30, respectively), followed by the heat polymerized PMMA group (85.65 ± 4.71 and 65.06 ± 2.27, respectively), and the 3D-printed group (91.34 ± 6.74 and 90.86 ± 8.57, respectively). While the smallest contact angle of drop of saliva substitute to denture base specimens was recorded in the milled group (56.82 ± 2.29 and 34.85 ± 7.51, respectively), followed by the 3D-printed group (72.87 ± 4.83 and 58.14 ± 9.58, respectively) and the heat polymerized PMMA group (83.62 ± 4.12 and 67.82 ± 4.93, respectively). There was statistically significant difference between the groups (P < .05). A significant decline in the average contact angle of drop of saliva has been reported in all groups after thermocycling. The contact angle values differed significantly between saliva substitute and distilled water in both 3D-printed and milled groups after thermocycling (P < .001). CONCLUSIONS: The milled denture base material presented the best wettability to water and saliva substitute than the 3D-printed and the heat-polymerized PMMA materials. Saliva substitutes improve the wetting ability of denture base materials manufactured by CAD/CAM compared with water.


Asunto(s)
Bases para Dentadura , Dentadura Completa , Polimetil Metacrilato , Impresión Tridimensional , Humectabilidad , Polimetil Metacrilato/química , Humanos , Técnicas In Vitro , Diseño de Dentadura , Materiales Dentales/química , Ensayo de Materiales , Propiedades de Superficie , Diseño Asistido por Computadora , Agua
3.
ACS Biomater Sci Eng ; 10(9): 5624-5631, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39107258

RESUMEN

Poly(methyl methacrylate) (PMMA) bone cements have been widely used in orthopedics; thanks to their excellent mechanical properties, biocompatibility, and chemical stability. Barium sulfate and zirconia are usually added into PMMA bone cement to enhance the X-ray radiopacity, while the mechanical strength, radiopacity, and biocompatibility are not well improved. In this study, an insoluble and corrosion-resistant ceramic, tantalum carbide (TaC), was added into the PMMA bone cement as radiopacifies, significantly improving the mechanical, radiopaque, biocompatibility, and osteogenic performance of bone cement. The TaC-PMMA bone cement with varied TaC contents exhibits compressive strength over 100 MPa, higher than that of the commercial 30% BaSO4-PMMA bone cement. Intriguingly, when the TaC content reaches 20%, the radiopacity is equivalent to the commercial bone cement with 30% of BaSO4 in PMMA. The cytotoxicity and osteogenic performance indicate that the incorporation of TaC not only enhances the osteogenic properties of PMMA but also does not reduce cell viability. This study suggests that TaC could be a superior and multifunctional radio-pacifier for PMMA bone cement, offering a promising avenue for improving patient outcomes in orthopedic applications.


Asunto(s)
Materiales Biocompatibles , Cementos para Huesos , Osteogénesis , Polimetil Metacrilato , Tantalio , Cementos para Huesos/química , Tantalio/química , Polimetil Metacrilato/química , Osteogénesis/efectos de los fármacos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Ensayo de Materiales , Supervivencia Celular/efectos de los fármacos , Humanos , Animales , Fuerza Compresiva , Ratones
4.
Biomacromolecules ; 25(9): 6135-6145, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39158737

RESUMEN

Reversible addition-fragmentation chain transfer (RAFT) dispersion polymerization-induced self-assembly (PISA) was conducted in the presence of poly(methyl methacrylate) (PMMA) stabilizer in ethanol/water mixture (80/20 by volume). Two different systems were explored by utilizing (i) 2-ethylhexyl methacrylate (EHMA) and (ii) n-butyl methacrylate (BMA). The morphology transitions of these systems were investigated by varying the polymerization conditions, i.e., the presence of the solvophilic comonomer MMA, the solids content, and the target degree of polymerization (DP). As observed in conventional PISA, the presence of solvophilic comonomer, increase in solids content and target DP promoted the formation of high-order morphology. However, unusual morphology transitions were observed whereby the morphology transformed from high-order morphologies to a mixture of spherical nanoparticles, worms, and vesicles and finally to vesicles with increasing target DP. This unusual evolution may be attributed to the limited solubility of PMMA in the ethanol/water solvent mixture, whereby PMMA is soluble at the polymerization temperature but insoluble at lower temperatures.


Asunto(s)
Polimerizacion , Polimetil Metacrilato , Agua , Polimetil Metacrilato/química , Agua/química , Metacrilatos/química , Etanol/química
5.
J Mech Behav Biomed Mater ; 158: 106680, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39153408

RESUMEN

This research paper explores the advancement of physical models simulating the human skull-brain complex, focusing on applications in simulating mild Traumatic Brain Injury (mTBI). Existing models, especially head forms, lack biofidelity in accurately representing the native structures of the skull, limiting the understanding of intracranial injury parameters beyond kinematic head accelerations. This study addresses this gap by investigating the use of additive manufacturing (AM) techniques to develop biofidelic skull surrogates. Materials such as Polylactic Acid (PLA), a bone-simulant PLA variant, and Hydroxyapatite-coated Poly(methyl methacrylate) (PMMA) were used to create models tested for their flexural modulus and strength. The trabecular bone regions were simulated by adjusting infill densities (30%, 50%, 80%) and print raster directions, optimizing manufacturing parameters for biofidelic performance. Among the tested materials, PLA and its bone-simulating variant printed at 80% infill density with a side (tangential) print orientation demonstrated the closest approximation to the mechanical properties of cranial bone, yielding a mean flexural modulus of 1337.2 MPa and a mean ultimate strength of 56.9 MPa. Statistical analyses showed that infill density significantly influenced the moduli and strength of the printed simulants. Digital Image Correlation (DIC) corroborated the comparable performance of the simulants, showing similar strain and displacement behaviors to native skull bone. Notably, the performance of the manufactured cortical and trabecular regions underscored their crucial role in achieving biofidelity, with the trabecular structure providing critical dampening effects when the native bone is loaded. This study establishes PLA, particularly its bone-simulant variant, as an optimal candidate for cranial bone simulants, offering significant potential for developing more accurate biofidelic head models in mTBI research.


Asunto(s)
Cráneo , Fenómenos Biomecánicos , Ensayo de Materiales , Humanos , Poliésteres/química , Polimetil Metacrilato/química , Fenómenos Mecánicos , Cabeza/anatomía & histología
6.
Am J Dent ; 37(4): 206-209, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39186602

RESUMEN

PURPOSE: To evaluate the in vitro antibacterial effect of Softsoap and Efferdent used as solutions to disinfect Lucitone 199 poly(methyl methacrylate) (PMMA) resin used for dentures. METHODS: S. mutans and plaque bacteria were grown for 24 hours, and suspended to a concentration of 1x106 cells/ml. Bacterial suspensions (0.2 mL) were added to the decontaminated PMMA discs placed in a 48-well culture plate and incubated for 3 days at 37°C. The discs were rinsed to remove the unbound bacterial cells and then incubated for 60 minutes with 5% and 1% dilutions (triplicates) of each of the detergent solutions (0.3 ml). Discs were rinsed and then MTT reagent (0.2 ml) was added and incubated for 2 hours, then overnight with a solubilizing agent. An aliquot from each well (0.1 ml) was transferred to a 96-well flat bottom plate and absorbance was measured to OD @ 595 nm (MTT) of four samples for each data point. Normalized data was compared and statistically analyzed using a three-way ANOVA with Student-Newman-Keuls on Rank data with P< 0.05 for significance. Additionally, data were double-checked with the Holm-Sidak test. RESULTS: There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration in time at 24 hours and 21 days (P= 0.07). Statistically significant differences were found between all treatment solutions group combinations (P< 0.001) except for 30% Softsoap versus Efferdent (P= 0.056). CLINICAL SIGNIFICANCE: There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration at 24 hours and 21 days (P= 0.07). Statistically significant differences were noted between all treatment solutions group combinations (P< 0.001), However, there was no difference between 30% Softsoap and Efferdent (P= 0.056).


Asunto(s)
Antibacterianos , Polimetil Metacrilato , Polimetil Metacrilato/química , Antibacterianos/farmacología , Streptococcus mutans/efectos de los fármacos , Humanos , Placa Dental/microbiología , Desinfección/métodos , Detergentes/farmacología , Dentaduras/microbiología , Ensayo de Materiales , Limpiadores de Dentadura/farmacología
7.
Med Eng Phys ; 130: 104215, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39160013

RESUMEN

Cranioplasty is the surgical repair of a bone defect in the skull resulting from a previous operation or injury, which involves lifting the scalp and restoring the contour of the skull with a graft made from material that is reconstructed from scans of the patient's own skull. The paper introduces a 3D printing technology in creating molds, which are filled with polymethyl methacrylate (PMMA) to reconstruct the missing bone part of the skull. The procedure included several steps to create a 3D model in an STL format, conversion into a G-code which is further used to produce the mold itself using a 3D printer. The paper presents our initial experience with 5 patients who undergone cranioplasty utilizing 3D printed molds. Making a patient-specific model is a very complex process and consists of several steps. The creation of a patient-specific 3D model loading of DICOM images obtained by CT scanning, followed by thresholding-based segmentation and generation of a precise 3D model of part of the patient's skull. Next step is creating the G-code models for 3D printing, after which the actual models are printed using Fused Deposition Modeling printer and PLA material. All surgeries showed good match of the missing bone part and part created using 3D printed mold, without additional steps in refinement. In such a way, 3D printing technology helps in creating personalized and visually appealing bone replacements, at a low cost of the final product.


Asunto(s)
Procedimientos de Cirugía Plástica , Impresión Tridimensional , Cráneo , Humanos , Cráneo/cirugía , Cráneo/diagnóstico por imagen , Procedimientos de Cirugía Plástica/instrumentación , Procedimientos de Cirugía Plástica/métodos , Polimetil Metacrilato , Tomografía Computarizada por Rayos X , Medicina de Precisión , Masculino
8.
BMC Oral Health ; 24(1): 1000, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39183299

RESUMEN

BACKGROUND: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling. Additionally, the impact of thermocycling on the TBS were also evaluated. METHODS: The TBS of 4 different denture base materials (Palapress (PL), Vertex Rapid Simplified (VR), Smile CAM total prosthesis (SC), and NextDent denture 3D+ (ND)) bonded to 2 acrylic-based (GC Soft-Liner (GC) and Tokuyama Rebase II (RB)) and 2 silicone-based (Ufi Gel P (UP) and Sofreliner Tough M (ST)) denture liners were tested. Specimens (n = 8) were divided into non-thermocycling and thermocycling groups. Non-thermocycling specimens were tested after 24-hours water immersion, while thermocycling specimens were underwent 5000 cycle and were immediately tested. Mode of failure was examined under a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey HSD tests (α = 0.05), and independent samples t test (α = 0.05) for TBS between non-thermocycling and thermocycling groups. RESULTS: For the non-thermocycling groups, within the same denture liner material, no significant differences were found between denture base materials, except the ND + RB group, which had significantly lower TBS. For the thermocycling groups, within the same denture liner material, the TBS in the PL group exhibited the highest and the ND group exhibited the lowest. Within the same denture base material, in both non-thermocycling and thermocycling groups, the TBS in the ST group exhibited the highest; in contrast, that in the GC group exhibited the lowest. No significant differences were observed in TBS between non-thermocycling and thermocycling groups, except for denture base materials bonded to the ST group, SC + UP, and ND + UP groups. CONCLUSIONS: Milled denture base can be relined with acrylic-based or silicone-based denture liner. However, cautions should be exercised when relining 3D printed denture base. Thermocycling did not affect TBS between acrylic-based denture liners and denture bases. In contrast, it affected the bond between silicone-based denture liner and denture base.


Asunto(s)
Bases para Dentadura , Alineadores Dentales , Ensayo de Materiales , Impresión Tridimensional , Resistencia a la Tracción , Resinas Acrílicas/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Polimerizacion , Materiales Dentales/química , Técnicas In Vitro , Calor , Análisis del Estrés Dental , Polimetil Metacrilato/química , Siliconas/química , Elastómeros de Silicona/química
9.
Biomed Phys Eng Express ; 10(6)2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39145621

RESUMEN

Objective.To investigate the potential of 3D-printable thermoplastics as tissue-equivalent materials to be used in multimodal radiotherapy end-to-end quality assurance (QA) devices.Approach.Six thermoplastics were investigated: Polylactic Acid (PLA), Acrylonitrile Butadiene Styrene (ABS), Polyethylene Terephthalate Glycol (PETG), Polymethyl Methacrylate (PMMA), High Impact Polystyrene (HIPS) and StoneFil. Measurements of mass density (ρ), Relative Electron Density (RED), in a nominal 6 MV photon beam, and Relative Stopping Power (RSP), in a 210 MeV proton pencil-beam, were performed. Average Hounsfield Units (HU) were derived from CTs acquired with two independent scanners. The calibration curves of both scanners were used to predict averageρ,RED and RSP values and compared against the experimental data. Finally, measured data ofρ,RED and RSP was compared against theoretical values estimated for the thermoplastic materials and biological tissues.Main results.Overall, goodρand RSP CT predictions were made; only PMMA and PETG showed differences >5%. The differences between experimental and CT predicted RED values were also <5% for PLA, ABS, PETG and PMMA; for HIPS and StoneFil higher differences were found (6.94% and 9.42/15.34%, respectively). Small HU variations were obtained in the CTs for all materials indicating good uniform density distribution in the samples production. ABS, PLA, PETG and PMMA showed potential equivalency for a variety of soft tissues (adipose tissue, skeletal muscle, brain and lung tissues, differences within 0.19%-8.35% for all properties). StoneFil was the closest substitute to bone, but differences were >10%. Theoretical calculations of all properties agreed with experimental values within 5% difference for most thermoplastics.Significance.Several 3D-printed thermoplastics were promising tissue-equivalent materials to be used in devices for end-to-end multimodal radiotherapy QA and may not require corrections in treatment planning systems' dose calculations. Theoretical calculations showed promise in identifying thermoplastics matching target biological tissues before experiments are performed.


Asunto(s)
Fotones , Polimetil Metacrilato , Impresión Tridimensional , Terapia de Protones , Humanos , Terapia de Protones/métodos , Terapia de Protones/instrumentación , Polimetil Metacrilato/química , Poliésteres/química , Plásticos , Poliestirenos/química , Calibración , Garantía de la Calidad de Atención de Salud , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Ensayo de Materiales , Resinas Acrílicas , Butadienos
10.
Anal Chem ; 96(33): 13588-13597, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39116295

RESUMEN

The excellent versatility of 5-axis computer numerical control (CNC) micromilling has led to its application for prototyping NMR microcoils tailored to mass-limited samples (reducing development time and cost). However, vibrations during 5-axis milling can hinder the creation of complex 3D volume microcoils (i.e., solenoids and saddle coils). To address these limitations, a high-resolution NSCNC ELARA 4-axis milling machine was developed with the extra precision required for making complex 3D volume microcoils. Upon investigating the performance of resonators made with various copper-coated dielectrics, resonators with poly(methyl methacrylate) (PMMA) provided the best SNR/line shape. Thus, complex 1.7 mm microcoil designs were machined from Cu-coated PMMA. A milled 6.4 mm solenoid also provided 6.6× the total carbon signal for a 13C-labeled broccoli seed compared to a commercial inverse 5 mm NMR probe (demonstrating potential for larger coil designs). However, the manufacture of coils <1.7 mm with copper-coated PMMA rods was challenging as ∼0.5 mm of remaining PMMA was needed to retain their structural integrity. To manufacture smaller microcoils, both a solenoid and saddle coil (both with 1 mm O.D., 0.1 mm thick walls) were etched from Cu-coated glass capillaries using a UV picosecond laser that was mounted onto an NSCNC 5-axis MiRA7L. Both resonators showed excellent signal and identified a wide range of metabolites in a 13C-labeled algae extract, while the solenoid was further tested on two copepod egg sacs (∼4 µg of total sample). In summary, the flexibility to prototype complex microcoils in-house allows laboratories to tailor microcoils to specific mass-limited samples while avoiding the costs of cleanrooms.


Asunto(s)
Rayos Láser , Espectroscopía de Resonancia Magnética , Polimetil Metacrilato , Espectroscopía de Resonancia Magnética/instrumentación , Polimetil Metacrilato/química , Cobre/química
11.
J Mech Behav Biomed Mater ; 158: 106662, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39096682

RESUMEN

Minimally invasive spine treatments have been sought after for elderly patients with comorbidities suffering from advanced degenerative disc disease. Percutaneous cement discoplasty (PCD) is one such technique where cement is injected into a degenerated disc with a vacuum phenomenon to relieve patients from pain. Adjacent vertebral fractures (AVFs) are however an inherent risk, particularly for osteoporotic patients, due to the high stiffness of the used cements. While low-modulus cements have been developed for vertebroplasty through the addition of linoleic acid, there are no such variations with a high-viscosity base cement, which is likely needed for the discoplasty application. Therefore, a low-modulus polymethyl methacrylate was developed by the addition of 12%vol. linoleic acid to a high-viscosity bone cement (hv-LA-PMMA). Initial experimental validation of the cement was performed by mechanical testing under compression over a period of 24 weeks, after storage in 37 °C phosphate buffer saline (PBS) solution. Furthermore, cement extracts were used to evaluate residual monomer release and the cytotoxicity of hv-LA-PMMA using fibroblastic cells. Relative to the base commercial cement, a significant reduction of Young's modulus and compressive strength of 36% and 42% was observed, respectively. Compression-tension fatigue tests at 5 MPa gave an average fatigue limit of 31,078 cycles. This was higher than another low-modulus cement and comparable to the fatigue properties of the disc annulus tissue. Monomer release tests showed that hv-LA-PMMA had a significantly higher release between 24 h and 7 days compared to the original bone cement, similarly to other low-modulus cements. Also, the control cement showed cytocompatibility at all time points of extract collection for 20-fold dilution, while hv-LA-PMMA only showed the same for extract collections at day 7. However, the 20-fold dilution was needed for both the control and the hv-LA-PMMA extracts to demonstrate more than 70% fibroblast viability at day 7. In conclusion, the mechanical testing showed promise in the use of linoleic acid in combination with a high-viscosity PMMA cement to achieve properties adequate to the application. Further testing and in vivo studies are however required to fully evaluate the mechanical performance and biocompatibility of hv-LA-PMMA for possible future clinical application.


Asunto(s)
Cementos para Huesos , Ácido Linoleico , Ensayo de Materiales , Fenómenos Mecánicos , Cementos para Huesos/química , Animales , Ácido Linoleico/química , Ratones , Pruebas Mecánicas , Polimetil Metacrilato/química , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Viscosidad , Fuerza Compresiva , Humanos
12.
Int J Nanomedicine ; 19: 8485-8499, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39185343

RESUMEN

Introduction: With the development of technology, personal heat management has become a focus of attention. Phase change fabrics, as intelligent materials, are expected to be widely used in multiple fields, bringing comfortable, intelligent and convenient living experience. Methods: In this study, miniature phase change microcapsules (MPCM) with n-octadecane as core and poly(methyl methacrylate) as shell were successfully prepared. Using the in-situ reduction property of polydopamine, gold nanoparticles were deposited on the surface of the microcapsules, which retained the heat storage function and imparted photothermal and antibacterial properties. The MPCM with photothermal conversion function was modified on the surface of silk fabric using aqueous polyurethane after verified by comprehensive material characterisation techniques. Results: Under the near infrared light of 808 nm wavelength and 0.134 W/cm² irradiation intensity, the MPCM@PDA@Au modified silk fabrics showed excellent photothermal conversion performance, which could be increased from 25°C to 60°C in 50s. After the light source was cut off, the fabrics showed good heat release ability, with melting enthalpy and crystallisation enthalpy reaching 41.58 J/g and 43.3 J/g, respectively, which were not changed after repeated cycles. After the light source is cut off, the fabric has good heat release ability, and the enthalpy of melting and crystallisation reaches 41.58 J/g and 43.3 J/g, respectively, and the photothermal efficiency remains unchanged after many cycles of use, which proves that it has excellent durability and stability. The antimicrobial test shows that the fabric has significant antibacterial effect on Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). Discussion: MPCM@PDA@Au silk fabrics bring new possibilities for the future of personal thermal management and antimicrobial protection in the field of medical health, outdoor sports and other areas of broad application prospects, heralding the birth of a series of innovative applications and solutions.


Asunto(s)
Antibacterianos , Cápsulas , Oro , Nanopartículas del Metal , Seda , Textiles , Oro/química , Nanopartículas del Metal/química , Cápsulas/química , Seda/química , Antibacterianos/química , Antibacterianos/farmacología , Indoles/química , Indoles/farmacología , Escherichia coli/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Polímeros/química , Humanos , Transición de Fase , Polimetil Metacrilato/química , Rayos Infrarrojos
13.
BMC Oral Health ; 24(1): 1013, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39210376

RESUMEN

BACKGROUND: Enhancing the antibacterial properties of polymethyl methacrylate (PMMA) dental resins is crucial in preventing secondary infections following dental procedures. Despite the necessity for such improvement, a universally applicable method for augmenting the antibacterial properties of PMMA without compromising its mechanical properties and cytotoxicity remains elusive. Consequently, this study aims to address the aforementioned challenges by developing and implementing a composite material known as zinc oxide/graphene oxide (ZnO/GO) nanocomposites, to modify the PMMA. METHODS: ZnO/GO nanocomposites were successfully synthesized by a one-step procedure and fully characterized by TEM, EDS, FTIR and XRD. Then the physical and mechanical properties of PMMA modified by ZnO/GO nanocomposites were evaluated through water absorption and solubility test, contact angle test, three-point bending tests, and compression test. Furthermore, the biological properties of the modified PMMA were evaluated by direct microscopic colony count method, crystal violet staining and CCK-8. RESULTS: The results revealed that ZnO/GO nanocomposites were successfully constructed. When the concentration of nanocomposites in PMMA was 0.2 wt. %, the flexural strength of the resin was increased by 23.4%, the compressive strength was increased by 31.1%, and the number of bacterial colonies was reduced by 60.33%. Meanwhile, It was found that the aging of the resin did not affect its antibacterial properties, and CCK-8 revealed that the modified PMMA had no cytotoxicity. CONCLUSION: ZnO/GO nanocomposites effectively improved the antibacterial properties of PMMA. Moreover, the mechanical properties of the resin were improved by adding ZnO/GO nanocomposites at a lower range of concentrations.


Asunto(s)
Antibacterianos , Grafito , Ensayo de Materiales , Nanocompuestos , Polimetil Metacrilato , Óxido de Zinc , Óxido de Zinc/farmacología , Óxido de Zinc/química , Nanocompuestos/química , Grafito/farmacología , Grafito/química , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacología , Antibacterianos/farmacología , Resistencia Flexional , Fuerza Compresiva , Difracción de Rayos X , Espectroscopía Infrarroja por Transformada de Fourier , Microscopía Electrónica de Transmisión
14.
PLoS One ; 19(8): e0305315, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39159167

RESUMEN

The morphological dynamics of microbial cell proliferation on an antimicrobial surface at an early growth stage was studied with Escherichia coli on the surface of a gel supplied with AgNbO3 antimicrobial particles. We demonstrated an inhibitory surface concentration, analogous to minimum inhibitory concentration, beyond which the growth of colonies and formation of biofilm are inhibited. In contrast, at lower concentrations of particles, after a lag time the cells circumvent the antimicrobial activity of the particles and grow with a rate similar to the case in the absence of particles. The lag time depends on the surface concentration of the particles and amounts to 2 h at a concentration of ½ minimum inhibitory concentration. The applicability of these findings, in terms of estimating inhibitory surface concentration, was tested in the case of antimicrobial polymethyl methacrylate (PMMA) bone cement.


Asunto(s)
Escherichia coli , Pruebas de Sensibilidad Microbiana , Escherichia coli/efectos de los fármacos , Escherichia coli/crecimiento & desarrollo , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Polimetil Metacrilato/química , Antiinfecciosos/farmacología , Propiedades de Superficie , Antibacterianos/farmacología , Niobio/farmacología , Niobio/química , Cementos para Huesos/farmacología
15.
Water Res ; 263: 122177, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39111211

RESUMEN

For the resource recovery of biomass waste, it is a challenge to simultaneously remove micro-/nano-plastics pollution but preserve organic resources. Wet oxidation is a promising technology for valorization of organic wastes through thermal hydrolysis and oxidation. This might in turn result in the degradation of microplastics in the presence of oxygen and high temperatures. Based on this hypothesis, this study quantified both microplastics and nanoplastics in an industrial-scale wet oxidation reactor from a full-size coverage perspective. Wet oxidation significantly reduced the size and mass of individual microplastics, and decreased total mass concentration of microplastics and nanoplastics by 94.8 % to 98.6 %. This technology also reduced the micro- and nanoplastic shapes and polymer types, resulting in a complete removal of fibers, clusters, polypropylene (PP) and poly(methyl methacrylate) (PMMA). The present study confirms that wet oxidation technology is effective in removing microplastics and nanoplastics while recovering organic waste.


Asunto(s)
Microplásticos , Oxidación-Reducción , Contaminantes Químicos del Agua/química , Polipropilenos/química , Plásticos/química , Polimetil Metacrilato/química
16.
BMC Oral Health ; 24(1): 893, 2024 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-39098928

RESUMEN

BACKGROUND: Polymethylmethacrylate (PMMA) bone cement is used in orthopedics and dentistry to get primary fixation to bone but doesn't provide a mechanically and biologically stable bone interface. Therefore, there was a great demand to improve the properties of the PMMA bone cement to reduce its clinical usage limitations and enhance its success rate. Recent studies demonstrated that the addition of halloysite nanotubes (HNTs) to a polymeric-based material can improve its mechanical and thermal characteristics. OBJECTIVES: The purpose of the study is to assess the compressive strength, flexural strength, maximum temperature, and setting time of traditional PMMA bone cements that have been manually blended with 7 wt% HNT fillers. METHODS: PMMA powder and monomer liquid were combined to create the control group, the reinforced group was made by mixing the PMMA powder with 7 wt% HNT fillers before liquid mixing. Chemical characterization of the HNT fillers was employed by X-ray fluorescence (XRF). The morphological examination of the cements was done using a scanning electron microscope (SEM). Analytical measurements were made for the compressive strength, flexural strength, maximum temperature, and setting time. Utilizing independent sample t-tests, the data was statistically assessed to compare mean values (p < 0.05). RESULTS: The findings demonstrated that the novel reinforced PMMA-based bone cement with 7 wt% HNT fillers showed higher mean compressive strength values (93 MPa) and higher flexural strength (72 MPa). and lower maximum temperature values (34.8 °C) than the conventional PMMA bone cement control group, which was (76 MPa), (51 MPa), and (40 °C), respectively (P < 0.05). While there was no significant difference in the setting time between the control and the modified groups. CONCLUSION: The novel PMMA-based bone cement with the addition of 7 wt% HNTs can effectively be used in orthopedic and dental applications, as they have the potential to enhance the compressive and flexural strength and reduce the maximum temperatures.


Asunto(s)
Cementos para Huesos , Arcilla , Fuerza Compresiva , Resistencia Flexional , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Nanotubos , Polimetil Metacrilato , Polimetil Metacrilato/química , Nanotubos/química , Arcilla/química , Cementos para Huesos/química , Silicatos de Aluminio/química , Espectrometría por Rayos X , Temperatura , Propiedades de Superficie
17.
Methods Mol Biol ; 2835: 307-315, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39105926

RESUMEN

Cell therapy and engineered tissue creation based on the use of human stem cells involves cell isolation, expansion, and cell growth and differentiation on the scaffolds. Microbial infections dramatically can affect stem cell survival and increase the risk of implant failure. To prevent these events, it is necessary to develop new materials with antibacterial properties for coating scaffold surfaces as well as medical devices, and all other surfaces at high risk of contamination. This chapter describes strategies for obtaining antibacterial blends for coating inert surfaces (polymethylmethacrylate, polycarbonate, Carbon Fiber Reinforced Polymer (CFRP)). In particular, the procedures for preparing antibacterial blends by mixing polymer resins with two types of antibacterial additives and depositing these blends on inert surfaces are described.


Asunto(s)
Células Madre , Ingeniería de Tejidos , Humanos , Ingeniería de Tejidos/métodos , Células Madre/citología , Propiedades de Superficie , Andamios del Tejido/química , Antibacterianos/farmacología , Cemento de Policarboxilato/química , Técnicas de Cultivo de Célula/métodos , Polimetil Metacrilato/química , Fibra de Carbono/química , Carbono/química , Antiinfecciosos/farmacología
18.
J Mater Sci Mater Med ; 35(1): 50, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39136804

RESUMEN

The human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure that involves replacing the removed portion with either autologous bone or alloplastic material. While titanium has traditionally been the preferred material for cranial implants due to its excellent properties and biocompatibility, its limitations have prompted the search for alternative materials. This research aimed to explore alternative materials to titanium for cranial implants in order to address the limitations of titanium implants and improve the performance of the cranioplasty process. A 3D model of a defective skull was reconstructed with a cranial implant, and the implant was simulated using various stiff and soft materials (such as alumina, zirconia, hydroxyapatite, zirconia-reinforced PMMA, and PMMA) as alternatives to titanium under 2000N impact forces. Alumina and zirconia implants were found to reduce stresses and strains on the skull and brain compared to titanium implants. However, PMMA implants showed potential for causing skull damage under current loading conditions. Additionally, PMMA and hydroxyapatite implants were prone to fracture. Despite these findings, none of the implants exceeded the limits for tensile and compressive stresses and strains on the brain. Zirconia-reinforced PMMA implants were also shown to reduce stresses and strains on the skull and brain compared to PMMA implants. Alumina and zirconia show promise as alternatives to titanium for the production of cranial implants. The use of alternative implant materials to titanium has the potential to enhance the success of cranial reconstruction by overcoming the limitations associated with titanium implants.


Asunto(s)
Materiales Biocompatibles , Análisis de Elementos Finitos , Ensayo de Materiales , Procedimientos de Cirugía Plástica , Cráneo , Estrés Mecánico , Titanio , Circonio , Humanos , Cráneo/cirugía , Titanio/química , Materiales Biocompatibles/química , Circonio/química , Procedimientos de Cirugía Plástica/métodos , Prótesis e Implantes , Durapatita/química , Polimetil Metacrilato/química , Óxido de Aluminio/química , Resistencia a la Tracción , Fracturas Craneales/cirugía , Fuerza Compresiva
19.
ACS Appl Mater Interfaces ; 16(31): 40767-40786, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39047263

RESUMEN

A modular and 3D compartmentalized microfluidic system with electrospun porous membranes (PMs) for epithelialized organ-on-a-chip systems is presented. Our novel approach involves direct deposition of polymer nanofibers onto a patterned poly(methyl methacrylate) (PMMA) substrate using electrospinning, resulting in an integrated PM within the microfluidic chip. The in situ deposition of the PM eliminates the need for additional assembly processes. To demonstrate the high throughput membrane integration capability of our approach, we successfully deposited nanofibers onto various chip designs with complex microfluidic planar structures and expanded dimensions. We characterized and tested the fully PMMA chip by growing an epithelial monolayer using the Caco-2 cell line to study drug permeability. A comprehensive analysis of the bulk and surface properties of the membrane's fibers made of PMMA and polystyrene (PS) was conducted to determine the polymer with the best performance for cell culture and drug transport applications. The PMMA-based membrane, with a PMMA/PVP ratio of 5:1, allowed for the fabrication of a uniform membrane structure along the aligned nanofibers. By modulating the fiber diameter and total thickness of the membrane, we could adjust the membrane's porosity for specific cell culture applications. The PMMA-PVP nanofibers exhibited a low polydispersity index value, indicating monodispersed nanofibers and a more homogeneous and uniform fiber network. Both types of membranes demonstrated excellent mechanical integrity under medium perfusion flow rates. However, the PMMA-PVP composition offered a tailored porous structure with modulable porosity based on the fiber diameter and thickness. Our developed platform enables dynamic in vitro modeling of the epithelial barrier and has applications in drug transport and in vitro microphysiological systems.


Asunto(s)
Dispositivos Laboratorio en un Chip , Nanofibras , Polimetil Metacrilato , Humanos , Células CACO-2 , Porosidad , Polimetil Metacrilato/química , Nanofibras/química , Membranas Artificiales , Poliestirenos/química
20.
J Indian Prosthodont Soc ; 24(3): 240-244, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946506

RESUMEN

AIM: The aim is to determine thermal conduction by heat-activated polymethylmethacrylate (PMMA) infiltrated with 1 weight% Titanium Dioxide (TiO2) and 1 weight% Zirconium Dioxide (ZrO2) nanoparticles and to compare with that of conventional PMMA. STUDY SETTING AND DESIGN: In vitro experimental study. MATERIALS AND METHODS: Eighteen disc shaped specimens with a thickness of 5 mm and diameter of 50 mm, were fabricated and grouped according to the material used: Group B1 (resin infiltrated with 1 weight% TiO2), Group B2 (resin infiltrated with 1 weight% ZrO2), and Control Group B3 (heat-activated conventional PMMA resin). Disc-shaped specimens were analyzed for thermal conductivity using "modified guarded hot plate apparatus" in the thermal lab of the Indian Space Research Organisation. STATISTICAL ANALYSIS USED: One-way ANOVA followed by Tukey's post hoc test was used to compare the arithmetic means of all three groups. RESULTS: A statistically significant difference was noted among all three groups. Group B2 had the maximum thermal conductivity, followed by Group B1. Thermal conductivity was the least for Group B3. A post hoc comparison revealed that the difference was significant between Group B2 and Group B3. CONCLUSION: Nano ZrO2 addition in PMMA increased its thermal conductivity. There is evidence that it improves its mechanical properties as well. Hence, Nano ZrO2 addition in PMMA is highly recommended. Nano TiO2 addition in PMMA did not provide any significant advantage in terms of thermal conductivity, but its addition in PMMA is justified because of its mechanical and antimicrobial properties.


Asunto(s)
Calor , Nanopartículas , Polimetil Metacrilato , Conductividad Térmica , Titanio , Circonio , Titanio/química , Circonio/química , Circonio/farmacología , Polimetil Metacrilato/química , Nanopartículas/química , Bases para Dentadura , Ensayo de Materiales , Técnicas In Vitro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA