Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.378
Filtrar
1.
Int J Chron Obstruct Pulmon Dis ; 19: 1989-2000, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247665

RESUMEN

Purpose: This study aimed to investigate the proportion and risk factors of paroxysmal atrial fibrillation (AF) and atrial arrhythmias (AA) in patients hospitalized for acute exacerbation of chronic obstructive pulmonary disease (AECOPD) in Vietnam. Patients and Methods: A prospective observational study was conducted at two major hospitals in Hanoi, Vietnam, from January 2022 to January 2023. A total of 197 AECOPD patients were recruited. ECG and 24-hour Holter ECG were used to diagnose paroxysmal AF and AA. Results: The prevalence of paroxysmal AF and AA were 15.2% and 72.6%, respectively. Factors associated with a higher likelihood of paroxysmal AF included aging 75 years old and above (aOR = 3.15; 95% CI: 1.28 to 8.48), Premature atrial complex (PAC) with 500 or more (aOR = 3.81; 95% CI: 1.48 to 10.97) and severity of COPD as group C and D (aOR = 3.41; 95% CI: 1.28 to 10.50). For AA, aging 75 years old and above (aOR = 2.25; 95% CI: 1.28 to 5.20), smoking (aOR = 2.10; 95% CI: 1.07 to 4.23) and P wave dispersion (PWD) with 40 milliseconds or more (aOR = 3.04; 95% CI: 1.54 to 6.19) were associated with a higher likelihood of AA. Conclusion: Overall, our findings highlight the associated factors with the paroxysmal AF and AA among AECOPD patients. This underscores the importance of a multifaceted approach to risk assessment and management in this vulnerable population, focusing not only on respiratory symptoms but also on comprehensive cardiovascular evaluation and intervention.


Asunto(s)
Fibrilación Atrial , Progresión de la Enfermedad , Hospitalización , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/terapia , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Masculino , Prevalencia , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Factores de Riesgo , Vietnam/epidemiología , Hospitalización/estadística & datos numéricos , Factores de Edad , Medición de Riesgo , Anciano de 80 o más Años , Complejos Atriales Prematuros/epidemiología , Complejos Atriales Prematuros/diagnóstico , Complejos Atriales Prematuros/fisiopatología , Electrocardiografía Ambulatoria
2.
Can Vet J ; 65(9): 874-879, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39219607

RESUMEN

A 10-year-old spayed female shih tzu dog was brought to the hospital because of recurring syncope that occurred simultaneously with a cough. Physical examination did not reveal an abnormal heart rhythm or abnormal heart sounds. Electrocardiography revealed sinus arrest of 4.7 s with intermittent escape beats during coughing. Additional examinations, including thoracic radiography, clinical pathology, and echocardiography, revealed no abnormalities of concern. Forty-eight-hour Holter monitoring captured 1 syncopal episode following severe coughing, during which the longest sinus arrest lasted 16 s with intermittent escape beats. This observation confirmed our strong suspicion that coughing was the cause of varying degrees of sinus arrest in this dog. Theophylline, codeine, and short-term prednisolone were prescribed to treat the dog's cough. The daily episodes of syncope ceased and coughing decreased. Subsequent 48-hour Holter monitoring revealed no abnormal pauses, and the owner did not report syncope. Theophylline and codeine were continued for 5 mo, during which time no syncope occurred. To our knowledge, this case provides the first clear evidence of a correlation between cough-induced sinus arrest and syncope in a veterinary patient, as confirmed by Holter monitoring and electrocardiography. Key clinical message: Cough-induced severe bradycardia and syncope were identified in a shih tzu dog. After the antitussive medication was adjusted, the signs resolved.


Bradycardie sévère et syncope provoquées par la toux chez un chienUne chienne shih tzu stérilisée âgée de 10 ans a été amenée à l'hôpital en raison d'une syncope récurrente survenue simultanément avec une toux. L'examen physique n'a révélé aucun rythme cardiaque anormal ni bruits cardiaques anormaux. L'électrocardiographie a révélé un arrêt sinusal de 4,7 s avec des battements d'échappements intermittents lors de la toux. Des examens complémentaires, notamment une radiographie thoracique, des analyses en pathologie clinique et une échocardiographie, n'ont révélé aucune anomalie préoccupante. Une surveillance Holter de 48 heures a capturé 1 épisode syncopal à la suite d'une toux sévère, au cours duquel l'arrêt sinusal le plus long a duré 16 s avec des battements d'échappements intermittents. Cette observation a confirmé nos fortes suspicions selon lesquelles la toux était la cause de divers degrés d'arrêt sinusal chez ce chien. De la théophylline, de la codéine et de la prednisolone de courte durée ont été prescrites pour traiter la toux du chien. Les épisodes quotidiens de syncope ont cessé et la toux a diminué. Une surveillance Holter ultérieure de 48 heures n'a révélé aucune pause anormale et le propriétaire n'a pas signalé de syncope. La théophylline et la codéine ont été poursuivies pendant 5 mois, période pendant laquelle aucune syncope ne s'est produite. À notre connaissance, ce cas constitue la première preuve claire d'une corrélation entre l'arrêt sinusal induit par la toux et la syncope chez un patient vétérinaire, comme le confirme la surveillance Holter et l'électrocardiographie.Message clinique clé :Une bradycardie et une syncope sévères induites par la toux ont été identifiées chez un chien shih tzu. Après ajustement du traitement antitussif, les signes ont disparu.(Traduit par Dr Serge Messier).


Asunto(s)
Bradicardia , Tos , Enfermedades de los Perros , Síncope , Animales , Perros , Femenino , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/tratamiento farmacológico , Síncope/veterinaria , Síncope/etiología , Tos/veterinaria , Tos/etiología , Bradicardia/veterinaria , Bradicardia/etiología , Teofilina/uso terapéutico , Electrocardiografía Ambulatoria/veterinaria , Electrocardiografía/veterinaria , Codeína/uso terapéutico
3.
Am Fam Physician ; 110(3): 259-269, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39283849

RESUMEN

Palpitations are a common symptom described by patients as a feeling of a racing or fluttering heart, a pounding chest, irregular or skipped heartbeats, or a pounding sensation in the neck. They are associated with a low mortality rate; however, recurrent palpitations have been shown to impair quality of life and increase health care use. Common triggers are cardiac disorders, endocrine and metabolic disorders, medication or illicit drug use, or psychosomatic disorders. A detailed history, physical examination, directed laboratory studies, and 12-lead electrocardiography are often sufficient to identify the etiology of palpitations. Additional testing may be indicated to include echocardiography, cardiac stress testing, electrocardiogram monitoring, or electrophysiologic studies to distinguish whether symptoms correlate with cardiac arrhythmia or structural or ischemic heart disease. Management of palpitations is based on the suspected etiology. In most cases of cardiac-induced palpitations, the treatment can include reassurance, education, trigger avoidance, or use of atrioventricular nodal blockers. Tachyarrhythmias may require cardiac ablation. Patients who have palpitations with no arrhythmia causality and no cardiac disease should be reassured; however, screening for psychosomatic disorders should be considered. Wearable smart devices with ambulatory electrocardiogram monitoring technologies are currently available to consumers; these tools have shown diagnostic accuracy for detection of arrhythmias, allowing patients to have greater participation in their health care. Am Fam Physician. 2024; 110(3):259-269.


Asunto(s)
Arritmias Cardíacas , Dispositivos Electrónicos Vestibles , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Electrocardiografía/métodos , Electrocardiografía/instrumentación
4.
Ann Noninvasive Electrocardiol ; 29(5): e70011, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39225437

RESUMEN

BACKGROUND: The aim of this study was to investigate the clinical implication of incidentally induced atrial fibrillation (AF) during programmed electrical stimulation (PES) in patients with left ventricular systolic dysfunction (≤40%) after an acute myocardial infarction (MI). METHODS: In this study, we included 231 patients from the Cardiac Arrhythmias and RIsk Stratification after Myocardial InfArction (CARISMA) study with left ventricular ejection fraction ≤40% and no prior history of AF. These patients underwent PES 6 weeks post-MI as part of the study protocol. Patients all received an implantable cardiac monitor (ICM) 3-21 days post-MI and were continuously monitored for cardiac arrhythmias for 2 years. Induction of AF was unwanted but reported if this incidentally occurred. RESULTS: A total of 61 patients (26%) developed AF within 2 years of follow-up, in which n = 10 (29%) had incidental AF during PES at baseline. The overall risk of AF was not significantly increased in patients with incidental AF (n = 34) during PES compared to patients without incidental AF (n = 197) (HR 1.6 [0.9-3.0], p = 0.14). The risk of bradyarrhythmia (HR = 0.2 [0.0-1.2], p = 0.07), ventricular arrhythmias (HR = 0.7 [0.1-5.8], p = 0.77), and major cardiovascular events (MACE) (HR 0.5 [0.2-1.7], p = 0.28) was not significantly different in patients with versus without incidental AF. CONCLUSIONS: Incidentally induced AF during PES in post-MI patients with reduced LVEF was not significantly associated with a higher risk of long-term atrial fibrillation, other cardiac arrhythmias, or major cardiac events. TRIAL REGISTRATION: NCT00145119.


Asunto(s)
Fibrilación Atrial , Infarto del Miocardio , Disfunción Ventricular Izquierda , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Electrocardiografía Ambulatoria/métodos , Estudios de Seguimiento , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/complicaciones
5.
Kardiologiia ; 64(8): 64-67, 2024 Aug 31.
Artículo en Ruso, Inglés | MEDLINE | ID: mdl-39262355

RESUMEN

In relation with the published article "Natriuretic Peptide Concentrations and Echocardiography Findings in Patients with Micro-atrial Fibrillation", we have issued a comment. The authors of the article addressed a widely discussed topic of "Short episodes of fast arrhythmias initially detected in records on implantable devices". Further, these episodes are studied already by Holter monitoring of different durations with assessment of their clinical significance. This is the subject of the cited article and our comment.


Asunto(s)
Fibrilación Atrial , Ecocardiografía , Electrocardiografía Ambulatoria , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ecocardiografía/métodos , Electrocardiografía Ambulatoria/métodos , Péptido Natriurético Encefálico/sangre , Biomarcadores
6.
Kardiologiia ; 64(8): 56-63, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39262354

RESUMEN

AIM: Atrial fibrillation (AF) is a rhythm disorder characterized by very rapid and disorganized atrial-derived electrical activations with uncoordinated atrial contractions. Very short periods of AF-like activity (micro-AF) may be precursors of undetected, silent episodes of atrial fibrillation. Here, we examined the relationship between natriuretic peptide concentrations and echocardiography findings in patients with micro-AF. MATERIAL AND METHODS: The electrocardiograms (ECGs) of patients complaining of palpitations were recorded with a 24­hour Holter monitor, and the patients were consecutively included in the study. Micro-AF was defined as sudden, irregular atrial tachycardia lasting less than 30 sec with episodes of ≥5 consecutive supraventricular depolarizations with the absolute absence of p-waves. After a G-power test, patients were consecutively included in the study: 45 patients in the micro-AF group and 45 patients in the control group. Laboratory parameters, ECG and echocardiographic findings of the two groups were compared. RESULTS: N-terminal pro B-type natriuretic peptide (Pro-BNP) and serum troponin T concentrations were higher in the micro-AF group, (375.5±63.6 pg / ml vs. 63.1±56.8 pg / ml, p<0.001; 13±11.4 ng / dl vs. 4.4±2.4 ng / dl, p<0.001 respectively.) Each 1 pg / ml increase in serum Pro-BNP increased the risk of micro-AF by 1.8 %. In the ROC analysis, the cut-off value of Pro-BNP for the diagnosis of micro-AF was 63.4 pg / ml, with a sensitivity of 91.1 % and a specificity of 73.3 %. Atrial electro-mechanical delay durations were significantly higher in the micro-AF group. To predict micro-AF, the inter-annulus plane electromechanical delay time (inter-annulus plane AEMD) had a cut-off value of 18.5 sec, with a sensitivity of 93.3 % and a specificity of 91.1 %. Left intra-annulus plane electro-mechanical delay time (intra-annulus AEMD LEFT) had a cut-off value of 11.5 sec with a 95.6 % sensitivity and 75.6 % specificity. In the ECG evaluation, maximum P wave duration (Pmax) (113±10.2 ms vs. 98±10.4 ms; p<0.001), minimum P wave duration (Pmin) (73.8±5.5 ms vs.70±6.3 ms; p<0.001) and P wave dispersion (PWD) (39.1±7.9 ms vs.28±7.6 ms; p<0.001) were longer in the micro-AF group. CONCLUSIONS: Micro-AF in patients may be predicted by evaluating ECG, echocardiographic, and serum natriuretic peptide data.


Asunto(s)
Fibrilación Atrial , Ecocardiografía , Péptido Natriurético Encefálico , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Ecocardiografía/métodos , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Electrocardiografía Ambulatoria/métodos , Anciano , Biomarcadores/sangre , Troponina T/sangre , Electrocardiografía/métodos
7.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39248622

RESUMEN

Ambulatory electrocardiogram (ECG) testing plays a crucial role in the early detection, diagnosis, treatment evaluation, and prevention of cardiovascular diseases. Clear ECG signals are essential for the subsequent analysis of these conditions. However, ECG signals obtained during exercise are susceptible to various noise interferences, including electrode motion artifact, baseline wander, and muscle artifact. These interferences can blur the characteristic ECG waveforms, potentially leading to misjudgment by physicians. To suppress noise in ECG signals more effectively, this paper proposes a novel deep learning-based noise reduction method. This method enhances the diffusion model network by introducing conditional noise, designing a multi-kernel convolutional transformer network structure based on noise prediction, and integrating the diffusion model inverse process to achieve noise reduction. Experiments were conducted on the QT database and MIT-BIH Noise Stress Test Database and compared with the algorithms in other papers to verify the effectiveness of the present method. The results indicate that the proposed method achieves optimal noise reduction performance across both statistical and distance-based evaluation metrics as well as waveform visualization, surpassing eight other state-of-the-art methods. The network proposed in this paper demonstrates stable performance in addressing electrode motion artifact, baseline wander, muscle artifact, and the mixed complex noise of these three types, and it is anticipated to be applied in future noise reduction analysis of clinical dynamic ECG signals.


Asunto(s)
Algoritmos , Artefactos , Humanos , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Relación Señal-Ruido , Procesamiento de Señales Asistido por Computador
8.
J Am Heart Assoc ; 13(17): e036236, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39206739

RESUMEN

BACKGROUND: Unknown cardioembolic sources are frequent causes of cryptogenic stroke. We analyzed the risk of atrial fibrillation (AF) or high burden of ectopic atrial activity (HBEA) in patients with cryptogenic stroke, assessing atrial function and 1-year outcomes. METHODS AND RESULTS: The ARIES (Atrial Imaging and Cardiac Rhythm in Cryptogenic Embolic Stroke) study is an observational study including patients with cryptogenic stroke. We analyzed the frequency of AF and HBEA (>3000 atrial ectopic beats/day or >2 bursts or atrial tachycardia between 3 beats and ≤30 seconds) in two 30-day Holter-ECGs, comparing advanced echocardiography signs of left atrial (LA) dysfunction according to rhythm: AF, HBEA, and normal sinus rhythm. We also evaluated 1-year stroke recurrence and mortality. The study included 109 patients; 35 (32.1%) patients had AF, 27 (24.8%) HBEA, and 47 (43.1%) normal sinus rhythm. Compared with those with normal sinus rhythm, patients with AF presented higher 2-dimensional and 3-dimensional LA indexed volumes (38.8±11.2 versus 27.3±11.8 mL/m2, and 50.6±17.2 versus 34.0±15.4 mL/m2, respectively, P<0.001), lower 3-dimensional LA ejection fraction (50±14.6 versus 62.7±11.8, P=0.001), LA reservoir strain (22.0±8.6 versus 30.4±10.5, P<0.001), and LA contraction strain (10.5±8.18 versus 17.1±7.5, P<0.001), remaining significant in multivariate analysis. Patients with HBEA showed higher LA indexed volumes and lower LA reservoir strain than patients with normal sinus rhythm only in univariate analysis. There were no differences in ischemic recurrence or mortality among the groups. CONCLUSIONS: Patients with cryptogenic stroke showed a high incidence of AF and HBEA. AF is strongly related to LA volume, LA function, and LA reservoir and contraction strain, whereas HBEA showed milder structural changes. Advanced LA echocardiography could help patient selection for long-term ECG monitoring in suspected cardiac sources.


Asunto(s)
Fibrilación Atrial , Función del Atrio Izquierdo , Electrocardiografía Ambulatoria , Accidente Cerebrovascular Embólico , Recurrencia , Humanos , Masculino , Femenino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Anciano , Persona de Mediana Edad , Accidente Cerebrovascular Embólico/etiología , Accidente Cerebrovascular Embólico/fisiopatología , Función del Atrio Izquierdo/fisiología , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca/fisiología , Factores de Riesgo , Complejos Atriales Prematuros/fisiopatología , Complejos Atriales Prematuros/diagnóstico , Complejos Atriales Prematuros/complicaciones , Complejos Atriales Prematuros/epidemiología , Ecocardiografía/métodos , Factores de Tiempo , Medición de Riesgo/métodos
9.
J Am Heart Assoc ; 13(17): e034994, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39190577

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a stroke risk factor that often remains undetected at hospital admission. Long-term Holter monitoring helps to identify patients with previously unrecognized AF. Asymmetric (ADMA) and symmetric dimethylarginine (SDMA) are elevated in AF in cross-sectional studies. We analyzed ADMA, SDMA, and other L-arginine metabolites to assess their association with AF in the Find-AF trial. METHODS AND RESULTS: We included 280 patients presenting with acute cerebral ischemia. Patients presenting in sinus rhythm received 7-day Holter-ECG. Biomarkers were quantified by ultra-performance liquid chromatography-tandem mass spectrometry. We also analyzed protein methylation and L-arginine-related metabolites in human induced pluripotent stem cell-derived cardiomyocytes in vitro. ADMA and SDMA were elevated in 44 patients who presented with AF. SDMA, but not ADMA, was significantly elevated in patients newly diagnosed with AF in Holter-ECG as compared with those in sinus rhythm. SDMA plasma concentration >0.571 µmol/L significantly predicted presence of AF in Holter-ECG (area under the curve=0.676 [0.530-0.822]; P=0.029; sensitivity 0.786, specificity 0.572). SDMA levels further increased in patients with AF during the first 24 hours in hospital, and ADMA levels remained stable. In vitro, induced pluripotent stem cell-derived cardiomyocytes showed increased symmetric protein methylation and elevated SDMA during rapid pacing (2.0 Hz versus 0.5 Hz), whereas asymmetric protein methylation and ADMA were unchanged. CONCLUSIONS: SDMA at admission was significantly elevated in stroke patients presenting with AF and showed a moderate but significant prospective association with previously unrecognized AF. Thus, stroke patients with elevated SDMA concentration at admission may specifically benefit from extended Holter-ECG monitoring.


Asunto(s)
Arginina , Fibrilación Atrial , Biomarcadores , Electrocardiografía Ambulatoria , Accidente Cerebrovascular Isquémico , Humanos , Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Arginina/análogos & derivados , Arginina/sangre , Masculino , Femenino , Accidente Cerebrovascular Isquémico/sangre , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Anciano , Biomarcadores/sangre , Persona de Mediana Edad , Miocitos Cardíacos/metabolismo , Valor Predictivo de las Pruebas , Espectrometría de Masas en Tándem , Células Madre Pluripotentes Inducidas/metabolismo
10.
Discov Med ; 36(187): 1610-1615, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39190376

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common type of arrhythmia. Heart rate variability (HRV) may be associated with AF risk. The aim of this study was to test HRV indices and arrhythmias as predictors of paroxysmal AF based on 24-hour dynamic electrocardiogram recordings of patients. METHODS: A total of 199 patients with paroxysmal AF (AF group) and 204 elderly volunteers over 60 years old (Control group) who underwent a 24-hour dynamic electrocardiogram from August 2022 to March 2023 were included. Time-domain indices, frequency-domain indices, and arrhythmia data of the two groups were classified and measured. Binary logistic regression analysis was performed on variables with significant differences to identify independent risk factors. A nomogram prediction model was established, and the sum of individual scores of each variable was calculated. RESULTS: Gender, age, body mass index and low-density lipoprotein (LDL) did not differ significantly between AF and Control groups (p > 0.05), whereas significant group differences were found for smoking, hypertension, diabetes, and high-density lipoprotein (HDL) (p < 0.05). The standard deviation of all normal to normal (NN) R-R intervals (SDNN), standard deviation of 5-minute average NN intervals (SDANN), root mean square of successive NN interval differences (rMSSD), 50 ms from the preceding interval (pNN50), low-frequency/high-frequency (LF/HF), LF, premature atrial contractions (PACs), atrial tachycardia (AT), T-wave index, and ST-segment index differed significantly between the two groups. Logistic regression analysis identified rMSSD, PACs, and AT as independent predictors of AF. For each unit increase in rMSSD and PACs, the odds of developing AF increased by 1.0357 and 1.0005 times, respectively. For each unit increase in AT, the odds of developing AF decreased by 0.9976 times. The total score of the nomogram prediction model ranged from 0 to 110. CONCLUSION: The autonomic nervous system (ANS) plays a pivotal role in the occurrence and development of AF. The individualized nomogram prediction model of AF occurrence contributes to the early identification of high-risk patients with AF.


Asunto(s)
Fibrilación Atrial , Frecuencia Cardíaca , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Frecuencia Cardíaca/fisiología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Factores de Riesgo , Electrocardiografía/métodos , Nomogramas , Electrocardiografía Ambulatoria/métodos , Análisis de Datos , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología
11.
Clinics (Sao Paulo) ; 79: 100448, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39096858

RESUMEN

OBJECTIVES: To study the complications and effectiveness of the treatment of chronic arrhythmias with cardiac Ganglion Plexus (GP) ablation, and to explore the value of the treatment of chronic arrhythmias with GP ablation. METHODS: This study was a one-arm interventional study of patients from the first hospital of Xinjiang Medical University and the People's Hospital of Xuancheng City admitted (09/2018-08/2021) because of bradyarrhythmia. The left atrium was modeled using the Carto3 mapping system. The ablation endpoint was the absence of a vagal response under anatomically localized and high-frequency stimulation guidance. Postoperative routine follow-up was conducted. Holter data at 3-, 6-, and 12-months were recorded. RESULTS: Fifty patients (25 male, mean age 33.16 ± 7.89 years) were induced vagal response by either LSGP, LIGP, RAGP, or RIGP. The heart rate was stable at 76 bpm, SNRT 1.092s. DC, DR, HR, SDNN, RMSSD values were lower than that before ablation. AC, SSR, TH values were higher than those before ablation, mean heart rate and the slowest heart rate were significantly increased. There were significant differences in follow-up data between the preoperative and postoperative periods (all p < 0.05). All the patients were successfully ablated, and their blood pressure decreased significantly. No complications such as vascular damage, vascular embolism and pericardial effusion occurred. CONCLUSIONS: Left Atrial GP ablation has good long-term clinical results and can be used as a treatment option for patients with bradyarrhythmia.


Asunto(s)
Bradicardia , Ablación por Catéter , Ganglios Autónomos , Humanos , Masculino , Femenino , Adulto , Ganglios Autónomos/cirugía , Bradicardia/etiología , Ablación por Catéter/métodos , Resultado del Tratamiento , Frecuencia Cardíaca/fisiología , Persona de Mediana Edad , Adulto Joven , Atrios Cardíacos/fisiopatología , Electrocardiografía Ambulatoria
12.
Acta Vet Hung ; 72(3): 178-185, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39172517

RESUMEN

Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.


Asunto(s)
Arritmias Cardíacas , Enfermedades de los Caballos , Animales , Caballos , Enfermedades de los Caballos/diagnóstico , Arritmias Cardíacas/veterinaria , Arritmias Cardíacas/diagnóstico , Masculino , Femenino , Electrocardiografía/veterinaria , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Electrocardiografía Ambulatoria/veterinaria , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos
13.
Arq Bras Cardiol ; 121(8): e20230771, 2024 Aug.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-39194043

RESUMEN

BACKGROUND: Heart rate (HR) has shown prognostic value in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm. However, the method of measurement is debated in the literature. OBJECTIVES: To compare HR on Holter with 3 resting electrocardiograms (ECG1, ECG2, and ECG3) in patients with HFrEF and sinus rhythm. METHODS: This was a cross-sectional study with 135 patients with heart failure with ejection fraction ≤ 40% and sinus rhythm. HR was assessed by ECG and Holter. Analyses included intraclass correlation coefficient (ICC), robust regression, root mean squared error, Bland-Altman, and area under the receiver operating characteristic (ROC) curve. A significance level of 0.05 and Bonferroni-Holm adjustment were adopted to minimize type I errors. RESULTS: The median [interquartile range] age and ejection fraction were 65 years [16] and 30% [11], respectively. The ICC of the 3 ECGs was 0.922 (95% confidence interval: 0.892; 0.942). The robust regression coefficients for ECG1 and ECG3 were 0.20 (95% confidence interval: 0.12; 0.29) and 0.21 (95% confidence interval: 0.06; 0.36). The robust R2 was 0.711 (95% confidence interval: 0.628; 0.76). In the Bland-Altman agreement analysis, the limits of agreement were -17.0 (95% confidence interval: -19.0; -15.0) and 32.0 (95% confidence interval: 30.0; 34.0). The area under the ROC curve was 0.896 (95% confidence interval: 0.865; 0.923). CONCLUSION: The HR on ECG showed high agreement with the HR on Holter, validating its clinical use in patients with HFrEF and sinus rhythm. However, agreement was suboptimal in one third of patients with HR below 70 bpm on ECG; thus, 24-hour Holter monitoring should be considered in this context.


FUNDAMENTO: A frequência cardíaca (FC) na insuficiência cardíaca com fração de ejeção reduzida (ICFEr) e ritmo sinusal apresenta valor prognóstico. Entretanto, o método de mensuração é debatido na literatura. OBJETIVOS: Comparar em pacientes com ICFEr e ritmo sinusal a FC no Holter com três eletrocardiogramas de repouso: ECG1, ECG2 e ECG3. METODOLOGIA: Estudo transversal com 135 pacientes portadores de insuficiência cardíaca com fração de ejeção ≤ 40% e ritmo sinusal. A FC foi avaliada por ECG e Holter. Análises incluíram o coeficiente de correlação intraclasse (CCI), regressão robusta, raiz do erro quadrático médio, Bland-Altman e a área sobre a curva ROC. Adotou-se nível de significância de 0,05 e o ajuste de Bonferroni-Holm para minimizar erros tipo I. RESULTADOS: As medianas [intervalo interquartil] de idade e fração de ejeção foram de 65 anos [16] e 30% [11], respectivamente. O CCI dos 3 ECG foi de 0,922 (intervalo de confiança de 95%: 0,892; 0,942). Os coeficientes de regressão robusta para ECG1 e ECG3 foram 0,20 (intervalo de confiança de 95%: 0,12; 0,29) e 0,21 (intervalo de confiança de 95%: 0,06; 0,36). O R2 robusto foi de 0,711 (intervalo de confiança de 95%: 0,628; 0,76). Na análise de concordância de Bland-Altman, os limites de concordância foram de −17,0 (intervalo de confiança de 95%: −19,0; −15,0) e 32,0 (intervalo de confiança de 95%: 30,0; 34,0). A área sob a curva ROC foi de 0,896 (intervalo de confiança de 95%: 0,865; 0,923). CONCLUSÃO: A FC do ECG mostrou alta concordância com a FC do Holter, validando seu uso clínico em pacientes com ICFEr e ritmo sinusal. Contudo, a concordância foi subótima em um terço dos pacientes com FC inferior a 70 bpm pelo ECG, devendo ser considerada a realização de Holter neste contexto.


Asunto(s)
Electrocardiografía Ambulatoria , Insuficiencia Cardíaca , Frecuencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Electrocardiografía Ambulatoria/métodos , Femenino , Masculino , Frecuencia Cardíaca/fisiología , Volumen Sistólico/fisiología , Anciano , Persona de Mediana Edad , Estudios Transversales , Reproducibilidad de los Resultados , Electrocardiografía/métodos , Curva ROC , Valores de Referencia
14.
Cardiovasc Diabetol ; 23(1): 295, 2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39127733

RESUMEN

BACKGROUND: A compromised cardiac autonomic function has been found in subjects with insulin resistance related disorders such as obesity, impaired glucose tolerance (IGT) and type 2 diabetes and confers an increased risk of adverse cardiovascular outcomes. Growing evidence indicate that 1 h plasma glucose levels (1hPG) during an oral glucose tolerance test (OGTT) ≥ 155 mg/dl identify amongst subjects with normal glucose tolerance (NGT) a new category of prediabetes (NGT 1 h-high), harboring an increased risk of cardiovascular organ damage. In this study we explored the relationship between 1 h post-load hyperglycemia and cardiac autonomic dysfunction. METHODS: Presence of cardiac autonomic neuropathy (CAN) defined by cardiovascular autonomic reflex tests (CARTs) and heart rate variability (HRV), assessed by 24-h electrocardiography were evaluated in 88 non-diabetic subjects subdivided on the basis of OGTT data in: NGT with 1 h PG < 155 mg/dl (NGT 1 h-low), NGT 1 h-high and IGT. RESULTS: As compared to subjects with NGT 1 h-low, those with NGT 1 h-high and IGT were more likely to have CARTs defined CAN and reduced values of the 24 h time domain HVR parameters including standard deviation of all normal heart cycles (SDNN), standard deviation of the average RR interval for each 5 min segment (SDANN), square root of the differences between adjacent RR intervals (RMSSD), percentage of beats with a consecutive RR interval difference > 50 ms (PNN50) and Triangular index. Univariate analyses showed that 1hPG, but not fasting and 2hPG, was inversely associated with all the explored HVR parameters and positively with CARTs determined presence of CAN. In multivariate regression analysis models including several confounders we found that 1hPG was an independent contributor of HRV and presence of CAN. CONCLUSION: Subjects with 1hPG ≥ 155 mg/dl have an impaired cardiac autonomic function.


Asunto(s)
Sistema Nervioso Autónomo , Glucemia , Prueba de Tolerancia a la Glucosa , Frecuencia Cardíaca , Hiperglucemia , Humanos , Estudios Transversales , Masculino , Femenino , Persona de Mediana Edad , Sistema Nervioso Autónomo/fisiopatología , Glucemia/metabolismo , Hiperglucemia/fisiopatología , Hiperglucemia/sangre , Hiperglucemia/diagnóstico , Adulto , Factores de Tiempo , Biomarcadores/sangre , Enfermedades del Sistema Nervioso Autónomo/fisiopatología , Enfermedades del Sistema Nervioso Autónomo/diagnóstico , Enfermedades del Sistema Nervioso Autónomo/sangre , Corazón/inervación , Corazón/fisiopatología , Electrocardiografía Ambulatoria , Estado Prediabético/fisiopatología , Estado Prediabético/diagnóstico , Estado Prediabético/sangre , Intolerancia a la Glucosa/diagnóstico , Intolerancia a la Glucosa/fisiopatología , Intolerancia a la Glucosa/sangre , Factores de Riesgo
15.
BMC Cardiovasc Disord ; 24(1): 460, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198735

RESUMEN

BACKGROUND AND OBJECTIVES: The hypothesis of the study was the assumption that the serum levels of soluble ST2 (sST2) and growth differentiation factor (GDF-15) can be predictors of atrial fibrillation (AF) recurrence in long-term period after primary radiofrequency catheter ablation (RFA). METHODS: Of the 165 patients included in the prospective follow-up, the final analysis included 131 patients whose follow-up duration reached 18 months after the end of the blanking period (3 months after RFA). The median age of patients was 59.0 (50.0; 64.0) years, and 80 (61%) were men. Paroxysmal AF was present in 103 (79%) and persistent AF in 28 (21%) patients. All patients underwent transthoracic and transesophageal echocardiography, and electroanatomic mapping was used to assess the area of low-voltage zones (LVZ). sST2 and GDF-15 levels were determined by ELISA using GDF-15/MIC-1 analytical kits (BioVender, Czech Republic) and Presage ST2 (Critical Diagnostics, USA) before RFA. After RFA, patients had regular follow-up visits at 3-6-9-12-18 months with 12-lead ECG or Holter ECG monitoring and with clinical evaluation. The primary endpoint was the occurrence of the first symptomatic AF recurrence (AFr) lasting > 30 s, recorded on an ECG or during daily ECG monitoring, after a blanking period. RESULTS: At the 18-month follow-up, 47 patients (35.9%) had AFr. The groups with and without AFr didn`t differ in the LVZ area. The medians of NT-proBNP, GDF-15 and sST2 also didn`t differ significantly between the groups, but in patients with AFr, the proportion of those with sST2 ≥ 36 ng/ml (the border of the lower and middle terziles) was higher (p = 0.03). According to the one-factor Cox regression analysis, AFr were associated with four factors: AF history ≥ 1 year, early AFr (during the blanking period), left atrial appendage flow velocity (LAAFV) < 54 cm/sec and sST2 ≥ 36 ng/ml. In the multivariate Cox analysis two independent predictors of AFr were obtained: sST2 ≥ 36 ng/ml (HR = 3.8; 95% CI 1.5-9.8, p = 0.006) and LAAFV < 54 сm/sec (HR = 1.96; 95% CI 1.01-3.82, p = 0.048). CONCLUSIONS: Serum sST2 level with a cut-off value of 36 ng/ml or more can be used as a predictor of AF recurrence in the long-term period after primary RFA.


Asunto(s)
Fibrilación Atrial , Biomarcadores , Ablación por Catéter , Factor 15 de Diferenciación de Crecimiento , Proteína 1 Similar al Receptor de Interleucina-1 , Valor Predictivo de las Pruebas , Recurrencia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/sangre , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Masculino , Proteína 1 Similar al Receptor de Interleucina-1/sangre , Femenino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Biomarcadores/sangre , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Factor 15 de Diferenciación de Crecimiento/sangre , Resultado del Tratamiento , Medición de Riesgo , Anciano , Electrocardiografía Ambulatoria
16.
Medicina (Kaunas) ; 60(8)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39202596

RESUMEN

Background and Objectives: Chronic heart failure (CHF) caused by ischemic heart disease (IHD) is the leading cause of death worldwide and presents significant health challenges. Effective management of IHD requires prevention, early detection, and treatment to improve patient outcomes. This study aims to expand the diagnostic utility of various 24 h Holter ECG parameters, such as T-wave alternans (TWA), late ventricular potentials (LVPs), and heart rate variability (HRV) in patients with CHF caused by IHD. Additionally, we seek to explore the association between these parameters and other comorbid conditions affecting the prognosis of CHF patients. Materials and Methods: We conducted a prospective case-control study with 150 patients divided into two subgroups: 100 patients with CHF caused by IHD, and 50 patients in the control group. Data included medical history, physical examination, laboratory tests, echocardiography, and 24 h Holter monitoring. Results: Our comparative analysis demonstrated that both TWA and LVPs were significantly higher in patients with CHF compared to the control group (p < 0.01), indicating increased myocardial electrical vulnerability in CHF patients. Both time and frequency-domain HRV parameters were significantly lower in the CHF group. However, the ratio of NN50 to the total count of NN intervals (PNN50) showed a borderline significance (p = 0.06). While the low-frequency (LF) domain was significantly lower in CHF patients, the high-frequency (HF) domain did not differ significantly between groups. Acceleration and deceleration capacities were also significantly altered in CHF patients. Categorizing CHF patients by left ventricular ejection fraction (LVEF) revealed that the mean of the 5-min normal-to-normal intervals over the complete recording (SDNN Index) was significantly higher in patients with LVEF ≥ 50% compared to those with CHF with reduced EF and CHF with mildly reduced EF (p < 0.001), whereas the other HRV parameters showed no significant differences among the groups. Conclusions: Holter ECG parameters can become a reliable tool in the assessment of patients with CHF. The integration of multiple Holter ECG parameters, such as TWA, LVPs, and HRV, can significantly enhance the diagnostic assessment of CHF caused by IHD. This comprehensive approach allows for a more nuanced understanding of the patient's condition and potential outcomes.


Asunto(s)
Electrocardiografía Ambulatoria , Insuficiencia Cardíaca , Isquemia Miocárdica , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Masculino , Estudios de Casos y Controles , Electrocardiografía Ambulatoria/métodos , Femenino , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Enfermedad Crónica , Frecuencia Cardíaca/fisiología
17.
J Am Coll Cardiol ; 84(10): 921-933, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39197982

RESUMEN

BACKGROUND: Young (<18 years of age) patients with Brugada syndrome (BrS) are often under-represented in BrS studies and their management, especially related to syncopal episodes, remains unclear. OBJECTIVES: This study sought to describe the arrhythmia prevalence among young patients with BrS undergoing continuous rhythm monitoring by implantable loop recorder (ILR) and to assess the etiology behind syncope of undetermined origin. METHODS: A total of 147 patients with BrS with ILR were enrolled in 12 international centers and divided into pediatric (age <12 years; n = 77, 52%) and adolescents (age 13-18 years; n = 70, 48%). RESULTS: Mean age was 11.3 years, 53 patients (36.1%) were female, and 31 (21.1%) had spontaneous type 1 electrocardiograms. Over a median follow-up of 3.6 years (Q1-Q3: 1.6-4.8 years), an arrhythmic event was recorded in 33 patients (22.4%), mainly of nonventricular origin: 15 atrial (10.2%) and 16 bradyarrhythmic events (10.9%). Ventricular arrhythmias occurred in 4 patients, all with spontaneous BrS, and were fever-related in one-half. Among all patients with recurrence of syncope during follow-up, true arrhythmic syncope was documented in 5 (17.8%), and it was due to bradyarrhythmias or atrial arrhythmias in 3 cases (60%). CONCLUSIONS: Continuous rhythm monitoring with ILRs in young patients with BrS detects a broad range of arrhythmias. Ventricular arrhythmias occur predominantly in patients with spontaneous type 1 electrocardiograms and during fever. Despite the young age, bradyarrhythmias and atrial arrhythmias are frequent and represent the cause of arrhythmic syncope in 60% of patients. Young patients with BrS with syncope of undetermined origin may benefit from ILR implant.


Asunto(s)
Síndrome de Brugada , Electrocardiografía Ambulatoria , Humanos , Adolescente , Femenino , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/complicaciones , Niño , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Estudios de Seguimiento , Síncope/diagnóstico , Síncope/etiología , Síncope/fisiopatología
18.
Herzschrittmacherther Elektrophysiol ; 35(3): 234-249, 2024 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-39158752

RESUMEN

Holter monitoring represents a valuable diagnostic tool to document intermittent arrhythmias in the work-up of, for example, syncope, presyncope, collapse, falls, dizziness, stroke, palpitations, and a rapid heartbeat. In addition, it may help in the diagnosis of intermittent ischemia and channelopathies, particularly in the form of 12-lead Holter monitoring. Continuous ECG registration typically lasts from 24-48 h. The use of Holter monitoring is limited in patients with rare symptoms (< 1â€¯× per month) and in recordings full of artifacts. The interpretation of a Holter recording combines an automatic analysis with a manual reassessment. The clinical relevance of many arrhythmias can only be considered together with symptoms and activity of the patient at the time of the event. Therefore, a patient diary accompanying the ECG recording is crucial. Systematic assessment of the ECG recording and knowledge about a number of pitfalls in Holter monitoring can optimize the interpretation of the recording.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía Ambulatoria , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Humanos , Arritmias Cardíacas/diagnóstico
19.
Stud Health Technol Inform ; 316: 471-472, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39176779

RESUMEN

Predicting lifespan much more accurately is important for the palliative care team and the families they accompany. However, the way physicians estimate survival time has a gap between the real conditions. This is the first study to use a senseless wearable sensor to collect electrocardiograms from hospice care patients and explore the final moments of patients' lives by analyzing heart rate variability.


Asunto(s)
Frecuencia Cardíaca , Dispositivos Electrónicos Vestibles , Humanos , Frecuencia Cardíaca/fisiología , Electrocardiografía Ambulatoria/instrumentación , Masculino , Cuidado Terminal , Femenino , Reproducibilidad de los Resultados , Anciano , Sensibilidad y Especificidad , Diseño de Equipo , Análisis de Falla de Equipo , Electrocardiografía , Persona de Mediana Edad
20.
Stud Health Technol Inform ; 316: 487-491, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39176784

RESUMEN

Smart wearables support continuous monitoring of vital signs for early detection of deteriorating health. However, the devices and sensors require sufficient quality to produce meaningful signals, in particular, if data is acquired in motion. In this study, we equipped 48 subjects with smart shirts recording one-lead electrocardiography (ECG), thoracic and abdominal respiratory inductance plethysmography, and three-axis acceleration. For 10 min each, the subjects sit, stand, walk, and run, with a resting period of 5 min in between each activity. We preprocessed the electrocardiogram and applied a signal quality index. We analyzed the signal quality index grouped by the activity and participants. For sitting, standing, walking, and running, the ECG signals provide acceptable quality over 73.20 %, 91.85 %, 12.26 %, and 13.14 % of the recording time. In conclusion, smart wearables may be useful for continuous health monitoring of people with a sedentary lifestyle, but rather not for sportive activities.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Vestuario , Masculino , Electrocardiografía , Adulto , Femenino , Electrocardiografía Ambulatoria/instrumentación , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA