Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 275
Filtrar
1.
Int. j. morphol ; 42(3): 554-560, jun. 2024. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1564614

RESUMEN

SUMMARY: The average volumes of normal heart chambers in computed tomography (CT) are used not only as clinical criterions for heart disease diagnosis, but also as references in cardiology. With the development of artificial intelligence (AI), numerous CT data can be analyzed and segmented automatically. This study aimed to determine the average volumes of the four chambers in healthy adult hearts and present surface models with the average volume. Coronary CT angiographs of 508 Korean individuals (330 men and 178 women, 20 - 39 years old) were obtained. An automatic segmentation module for 3D Slicer was developed using machine learning in Anatomage KoreaTM. Using the module, the four chambers and heart valves in the CT were segmented and reconstructed into surface models. Surface models of the four chambers of identical hearts in the CT were produced using SimplewareTM. The volumes of structures were measured using Sim4life Light and statistically analyzed. After determining the average volumes of the four chambers, surface models of the average volumes were constructed. In both software measurements, the atrial volumes of females increased with age, and the ventricular volumes of males decreased significantly with age. The atrial and ventricular volumes of Simpleware were larger and smaller than those of Anatomage, respectively, because of errors in the Simpleware. Regarding the volume measurement, our module developed in this study was more accurate than the Simpleware. The average volume and three-dimensional models used in this study can be used not only for clinical purposes, but also for educational or industrial purposes.


Los volúmenes medios de las cámaras cardíacas normales en la tomografía computarizada (TC) se utilizan no sólo como criterios clínicos para el diagnóstico de enfermedades cardíacas, sino también como referencia en cardiología. Con el desarrollo de la inteligencia artificial (IA), numerosos datos de TC se pueden analizar y segmentar automáticamente. Este estudio tuvo como objetivo determinar los volúmenes promedio de las cuatro cámaras en corazones adultos sanos y presentar modelos de superficie con el volumen promedio. Se obtuvieron angiografías coronarias por TC de 508 individuos coreanos (330 hombres y 178 mujeres, de 20 a 39 años). Se desarrolló un módulo de segmentación automática para 3D Slicer utilizando aprendizaje automático en Anatomage KoreaTM. Utilizando el módulo, las cuatro cámaras y valvas cardíacas de la TC se segmentaron y reconstruyeron en modelos de superficie. Se produjeron modelos de superficie de las cuatro cámaras de corazones idénticos en la TC utilizando SimplewareTM. Los volúmenes de las estructuras se midieron utilizando Sim4life Light y se analizaron estadísticamente. Después de determinar los volúmenes promedio de las cuatro cámaras, se construyeron modelos de superficie de los volúmenes promedio. En ambas mediciones de software, los volúmenes atriales de las mujeres aumentaron con la edad y los volúmenes ventriculares de los hombres disminuyeron significativamente con la edad. Los volúmenes atrial y ventricular de Simpleware eran mayores y menores que los de Anatomage, respectivamente, debido a errores en Simpleware. En cuanto a la medición de volumen, nuestro módulo desarrollado en este estudio fue más preciso que el Simpleware. Los modelos tridimensionales y de volumen medio utilizados en este estudio se pueden utilizar no solo con fines clínicos, sino también con fines educativos o industriales.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Adulto Joven , Inteligencia Artificial , Volumen Cardíaco , Angiografía por Tomografía Computarizada , Corazón/diagnóstico por imagen , Imagenología Tridimensional
2.
Curr Cardiol Rep ; 26(6): 635-641, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38656586

RESUMEN

PURPOSE OF REVIEW: More than a century since its discovery, the pathogenesis of Chagas heart disease (CHD) remains incompletely understood. The role of derangements in the autonomic control of the heart in triggering malignant arrhythmia before the appearance of contractile ventricular impairment was reviewed. RECENT FINDINGS: Although previous investigations had demonstrated the anatomical and functional consequences of parasympathetic dysautonomia upon the heart rate control, only recently, coronary microvascular disturbances and sympathetic denervation at the ventricular level have been reported in patients and experimental models of CHD, exploring with nuclear medicine methods their impact on the progression of myocardial dysfunction and cardiac arrhythmias. More important than parasympathetic impaired sinus node regulation, recent evidence indicates that myocardial sympathetic denervation associated with coronary microvascular derangements is causally related to myocardial injury and arrhythmia in CHD. Additionally, 123I-MIBG imaging is a promising tool for risk stratification of progression of ventricular dysfunction and sudden death.


Asunto(s)
Cardiomiopatía Chagásica , Simpatectomía , Humanos , Simpatectomía/métodos , Cardiomiopatía Chagásica/fisiopatología , Cardiomiopatía Chagásica/cirugía , Cardiomiopatía Chagásica/complicaciones , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Corazón/inervación , Corazón/diagnóstico por imagen , 3-Yodobencilguanidina , Sistema Nervioso Simpático/fisiopatología
3.
PLoS One ; 18(10): e0293560, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37889912

RESUMEN

Cardiovascular diseases related to the right side of the heart, such as Pulmonary Hypertension, are some of the leading causes of death among the Mexican (and worldwide) population. To avoid invasive techniques such as catheterizing the heart, improving the segmenting performance of medical echocardiographic systems can be an option to early detect diseases related to the right-side of the heart. While current medical imaging systems perform well segmenting automatically the left side of the heart, they typically struggle segmenting the right-side cavities. This paper presents a robust cardiac segmentation algorithm based on the popular U-NET architecture capable of accurately segmenting the four cavities with a reduced training dataset. Moreover, we propose two additional steps to improve the quality of the results in our machine learning model, 1) a segmentation algorithm capable of accurately detecting cone shapes (as it has been trained and refined with multiple data sources) and 2) a post-processing step which refines the shape and contours of the segmentation based on heuristics provided by the clinicians. Our results demonstrate that the proposed techniques achieve segmentation accuracy comparable to state-of-the-art methods in datasets commonly used for this practice, as well as in datasets compiled by our medical team. Furthermore, we tested the validity of the post-processing correction step within the same sequence of images and demonstrated its consistency with manual segmentations performed by clinicians.


Asunto(s)
Heurística , Procesamiento de Imagen Asistido por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Corazón/diagnóstico por imagen , Aprendizaje Automático
4.
ABC., imagem cardiovasc ; 36(1): e372, abr. 2023. tab.
Artículo en Portugués | LILACS | ID: biblio-1451685

RESUMEN

Fundamento: O exercício intenso e continuado em atletas provoca fenótipos de remodelamento adaptativo, cujos parâmetros podem ser avaliados pela ecocardiografia convencional, e de deformação miocárdica. Assim, foi comparado o remodelamento miocárdico em atletas do sexo feminino (grupo atletas) com mulheres sedentárias da mesma faixa etária (grupo-controle) e entre atletas com maior e menor tempo de treinamento. Métodos: Foram selecionadas 57 futebolistas femininas (grupo atletas) e 25 mulheres sadias sedentárias (grupocontrole). As atletas foram divididas em dois grupos: grupo principal, com 32 atletas, e grupo sub-17, com 25 atletas. Foram determinadas, através de ecocardiografia, as dimensões, a função sistólica e diastólica das câmaras cardíacas e a deformação miocárdica (strain longitudinal, circunferencial, radial e mecânica rotacional), utilizando a estatística Z com significância de p < 0,05. Resultados: A idade dos grupos atletas, controle, principal e sub-17 foi de 22,1±6,3; 21,2±5,0; 26,5±5,1; e 16,5±0,6, respectivamente. O peso, o índice de massa corporal e a frequência cardíaca foram menores no grupo atletas. A espessura das paredes, o índice de massa do ventrículo esquerdo (VE), o volume do átrio esquerdo (AE), a fração de ejeção e as dimensões do ventrículo direito (VD) foram maiores no grupo atletas, mas dentro de valores normais. A deformação miocárdica mostrou diminuição do strain radial, da rotação basal, da rotação apical e do twist, sugerindo mecanismo de reserva contrátil. Esses parâmetros foram menores no grupo principal, que também apresentava maior espessura das paredes, maior volume do AE e maior tamanho do VD, sugerindo que o aumento da reserva contrátil se relaciona com maior tempo de treinamento. Conclusões: As atletas do sexo feminino com treinamento intenso de longa duração apresentam remodelamento adaptativo das câmaras cardíacas e aumento da reserva contrátil observada em repouso, com esses parâmetros mais acentuados nas atletas com maior tempo de treinamento.(AU)


Background: Intense continuous exercise provokes adaptive remodeling phenotypes in athletes, the parameters of which can be evaluated through conventional echocardiography and myocardial deformation. We compared myocardial remodeling in female athletes (athlete group) with sedentary women of the same age range (control group) and between older and younger athletes. Methods: A total of 57 female soccer players and 25 healthy sedentary women were selected. The athlete group was subdivided into a main group and those under 17 years of age (< 17 group). The dimensions and systolic and diastolic function of the cardiac chambers and myocardial deformation (longitudinal and circumferential, as well as radial strain and rotational mechanics) was determined through echocardiography, using the Z statistic with a significance level of p< 0.05. Results: The mean age of the athlete, control, main, and < 17 groups was 22.1 (SD, 6.3); 21.2 (SD, 5.0); 26.5 (SD, 5.1); 16.5 (SD, 0.6) years, respectively. Weight, body mass index and heart rate were lower in the athlete group. Wall thickness, left ventricular mass index, left atrial (LA) volume, ejection fraction, and right ventricular dimensions were higher in athlete group, but remained within normal ranges. Regarding myocardial deformation, there was decreased radial strain, basal rotation, apical rotation, and twisting in the athlete group, suggesting a contractile reserve mechanism. These parameters were lesser in the main athlete group, who also had greater wall thickness, greater volume in the left atrium (LA) and larger size in the right ventricle (RV), suggesting that increased contractile reserve is related to longer time spent in the sport. Conclusions: In female athletes who had undergone intense long-term training, we observed adaptive remodeling of the cardiac chambers and increased contractile reserve (at rest), and these changes were more pronounced in those with longer involvement in the sport.(AU)


Asunto(s)
Humanos , Femenino , Adolescente , Adulto , Atletas , Remodelación Atrial/fisiología , Corazón/fisiopatología , Corazón/diagnóstico por imagen , Ecocardiografía/métodos , Conducta Sedentaria , Entrenamiento de Intervalos de Alta Intensidad/efectos adversos , Tensión Longitudinal Global/efectos de la radiación
5.
ABC., imagem cardiovasc ; 36(1): e20230002, abr. 2023. ilus, tab
Artículo en Portugués | LILACS | ID: biblio-1452586

RESUMEN

A prática regular de esportes pode induzir adaptações no coração, sendo essa condição comumente chamada de "coração de atleta". As alterações observadas incluem dilatação das câmaras cardíacas, aumento da espessura miocárdica, melhora do enchimento ventricular, aumento da trabeculação do ventrículo esquerdo (VE), dilatação da veia cava inferior, entre outras. Essas alterações também podem ser observadas em algumas doenças cardíacas, como cardiomiopatia (CMP) dilatada, hipertrófica e outras. Dessa forma, os exames de imagem cardíaca são fundamentais na identificação dessas alterações e na diferenciação entre o "coração de atleta" e uma possível cardiopatia.(AU)


Exercise-induced adaptation may occur in amateur and professional athletes. This condition is commonly named "athlete's heart". The alterations observed include dilation of the heart chambers, increased myocardial thickness, improved ventricular filling, increased left ventricular trabeculation, dilation of the inferior vena cava, among others. These changes can also be observed in some heart diseases, such as dilated, hypertrophic and other cardiomyopathies (CMP). Thus, cardiac imaging tests are fundamental in identifying these alterations and in differentiating between "athlete's heart" and possible heart disease. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Cardiomiopatía Dilatada/diagnóstico , Cardiomegalia Inducida por el Ejercicio/fisiología , Corazón/anatomía & histología , Corazón/diagnóstico por imagen , Ecocardiografía/métodos , Espectroscopía de Resonancia Magnética/métodos , Radiografía Torácica/métodos , Ecocardiografía Doppler/métodos , Ejercicio Físico/fisiología , Electrocardiografía/métodos
7.
J Bras Pneumol ; 48(5): e20220098, 2022.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36383779

RESUMEN

OBJECTIVE: Patients with COPD are prone to cardiac remodeling; however, little is known about cardiac function in patients recovering from an acute exacerbation of COPD (AECOPD) and its association with exercise capacity. The aim of this study was to evaluate the cardiac function and structure and to compare their relationship with exercise capacity in patients with a recent AECOPD and patients with clinically stable COPD. METHODS: This was a cross-sectional study including 40 COPD patients equally divided into two groups: recent AECOPD group (AEG) and clinically stable COPD group (STG). Echocardiography was performed to assess cardiac function and chamber structure. The six-minute walk distance (6MWD) and the Duke Activity Status Index (estimated Vo2) were used in order to assess exercise capacity. RESULTS: No significant differences in cardiac function and structure were found between the groups. The 6MWD was associated with early/late diastolic mitral filling velocity ratio (r = 0.50; p < 0.01), left ventricular posterior wall thickness (r = -0.33; p = 0.03), and right atrium volume index (r = -0.34; p = 0.04), whereas Vo2 was associated with right atrium volume index (r = -0.40; p = 0.02). CONCLUSIONS: Regardless of the clinical condition (recent AECOPD vs. stable COPD), the cardiac function and structure were similar between the groups, and exercise capacity (determined by the 6MWD and Vo2) was associated with cardiac features.


Asunto(s)
Tolerancia al Ejercicio , Corazón , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Estudios Transversales , Ecocardiografía , Prueba de Esfuerzo , Tolerancia al Ejercicio/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Pruebas de Función Cardíaca , Corazón/diagnóstico por imagen , Corazón/fisiología
8.
Arq Bras Cardiol ; 118(2): 519-524, 2022 02.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-35262590

RESUMEN

Hyperactivation of the sympathetic nervous system plays a central role in the pathophysiology of hypertension. The aim of this study was to assess cardiac sympathetic activity and investigate the role of myocardial123I-labelled meta-iodo benzyl guanidine ([123I] MIBG) scintigraphy in cardiovascular risk stratification of patients with resistant hypertension treated with renal denervation (RDN). Eighteen patients were included in this prospective study (mean age 56 ± 10 years old, 27.8% females). Transthoracic echocardiogram, general blood analysis and myocardial ([123I] MIBG scintigraphy were performed before and six-months after RDN. A patient was considered a responder (R) if a drop ≥ 5mmHg on mean systolic ambulatory blood pressure (BP) monitoring was observed at the six-month follow-up. 66.7% of patients were R (drop in systolic BP of 20.6 ± 14.5mmHg, vs minus 8 ± 11.6mmHg in non-responders (NR), p=0.001). Early heart-mediastinum ratio (HMR) was significantly lower at baseline in the R group (1.6 ± 0.1 vs 1.72 ± 0.1, p<0.02) but similar at six months. Considering both instants in time, the R group had lower early HMR values than the NR group (p<0.05). Both the late HMR and the washout rate were identical and no significant correlation between response to RDN or any MIBG imaging index was found. Renal denervation effectively lowered blood pressure in the majority of patients but [123I] MIBG was not useful in predicting the response. However, there was evidence of sympathetic overdrive and, both early and late HMR were overall reduced, probably putting this population at a higher risk of adverse events.


A hiperativação do sistema nervoso simpático desempenha um papel central na fisiopatologia da hipertensão. O objetivo deste estudo foi avaliar a atividade simpática cardíaca e investigar o papel da cintigrafia miocárdica com metaiodobenzilguanidina com 123I ([123I] MIBG) na estratificação de risco cardiovascular de pacientes com hipertensão resistente tratados com denervação renal (DR). Dezoito pacientes foram incluídos neste estudo prospectivo (média de idade de 56 ± 10 anos, 27,8% mulheres). Ecocardiograma transtorácico, análise geral do sangue e cintilografia miocárdica com [(123I) MIBG] foram realizados antes e seis meses após a DR. Um paciente era considerado respondedor (R) se uma diminuição ≥ 5 mmHg na pressão arterial sistólica (PAS) média ambulatorial fosse observada no seguimento de seis meses. 66,7% dos pacientes foram R (diminuição na PAS de 20,6 ± 14,5 mmHg, vs. menos 8 ± 11,6 mmHg em não-respondedores (NR), p = 0,001). A relação coração-mediastino (RCM) inicial foi significativamente menor na linha basal no grupo R (1,6 ± 0,1 vs. 1,72 ± 0,1, p <0,02), mas semelhante em seis meses. Considerando os dois momentos no tempo, o grupo R teve valores iniciais de RCM mais baixos do que o grupo NR (p <0,05). Tanto o RCM tardio quanto a taxa de washout foram idênticos e nenhuma correlação significativa entre a resposta à DR ou qualquer índice de imagem com MIBG foi encontrada. A denervação renal efetivamente reduziu a pressão arterial na maioria dos pacientes, mas a imagem com [123I] MIBG não foi útil na previsão da resposta. Entretanto, houve evidência de overdrive do sistema nervoso simpático e, tanto a RCM inicial quanto tardia estavam reduzidas em geral, provavelmente colocando essa população em um risco maior de eventos adversos.


Asunto(s)
3-Yodobencilguanidina , Monitoreo Ambulatorio de la Presión Arterial , Anciano , Desnervación , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiología , Humanos , Radioisótopos de Yodo , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiofármacos , Medición de Riesgo , Sistema Nervioso Simpático/diagnóstico por imagen
10.
ABC., imagem cardiovasc ; 35(3): erer_07, 2022. ilus, tab
Artículo en Portugués | LILACS | ID: biblio-1411516

RESUMEN

A necessidade de examinar o coração com uma ferramenta tridimensional não é nova na ecocardiografia. O órgão complexo e dinâmico em estudo sempre exigiu o entendimento em três dimensões e em tempo real. Sem o recurso, o examinador precisa transformar as imagens em bidimensional para uma compreensão de volume que exige complexa interação de conhecimentos e aproximações. A invenção da tridimensão já contabiliza três décadas, e seu aprimoramento levou a produtos comerciais no início do século. Estudos demonstram, no mínimo, equivalência da tridimensão com ganhos no manuseio do tempo necessário. Utilizamos as modalidades Tri Plano na rotina com ganho de tempo e menor estresse do membro superior do examinador. A tridimensão pode responder perguntas mais complexas e auxilia em nossa abordagem mais geométrica da contração, sendo o espessamento analisado em segundo plano.(AU)


The need to examine the heart using a three-dimensional (3D) tool is not new. This complex and dynamic organ has always required 3D and real-time understanding. Without this feature, the examiner has to transform two-dimensional images to understand its volume, which requires complex knowledge and approximation interactions. Echocardiography was invented three decades ago, and its improvements resulted in commercial products at the beginning of the century. Some studies demonstrate 3D equivalence with gains in handling the necessary time. We use triplane modalities in our routine, with time gain and less stress on the examiner's upper limb. Thus, 3D examinations can answer more complex questions and provide a more geometric approach to contraction, with thickening being analyzed in the background. (AU)


Asunto(s)
Humanos , Técnicas de Imagen Cardíaca/métodos , Corazón/anatomía & histología , Corazón/diagnóstico por imagen , Ecocardiografía/métodos , Espectroscopía de Resonancia Magnética/métodos , Ecocardiografía Tridimensional/métodos , Imagenología Tridimensional/métodos , Ecocardiografía de Estrés/métodos
11.
Arq. bras. cardiol ; Arq. bras. cardiol;118(2): 519-524, 2022. tab, graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-1364326

RESUMEN

Resumo A hiperativação do sistema nervoso simpático desempenha um papel central na fisiopatologia da hipertensão. O objetivo deste estudo foi avaliar a atividade simpática cardíaca e investigar o papel da cintigrafia miocárdica com metaiodobenzilguanidina com 123I ([123I] MIBG) na estratificação de risco cardiovascular de pacientes com hipertensão resistente tratados com denervação renal (DR). Dezoito pacientes foram incluídos neste estudo prospectivo (média de idade de 56 ± 10 anos, 27,8% mulheres). Ecocardiograma transtorácico, análise geral do sangue e cintilografia miocárdica com [(123I) MIBG] foram realizados antes e seis meses após a DR. Um paciente era considerado respondedor (R) se uma diminuição ≥ 5 mmHg na pressão arterial sistólica (PAS) média ambulatorial fosse observada no seguimento de seis meses. 66,7% dos pacientes foram R (diminuição na PAS de 20,6 ± 14,5 mmHg, vs. menos 8 ± 11,6 mmHg em não-respondedores (NR), p = 0,001). A relação coração-mediastino (RCM) inicial foi significativamente menor na linha basal no grupo R (1,6 ± 0,1 vs. 1,72 ± 0,1, p <0,02), mas semelhante em seis meses. Considerando os dois momentos no tempo, o grupo R teve valores iniciais de RCM mais baixos do que o grupo NR (p <0,05). Tanto o RCM tardio quanto a taxa de washout foram idênticos e nenhuma correlação significativa entre a resposta à DR ou qualquer índice de imagem com MIBG foi encontrada. A denervação renal efetivamente reduziu a pressão arterial na maioria dos pacientes, mas a imagem com [123I] MIBG não foi útil na previsão da resposta. Entretanto, houve evidência de overdrive do sistema nervoso simpático e, tanto a RCM inicial quanto tardia estavam reduzidas em geral, provavelmente colocando essa população em um risco maior de eventos adversos.


Abstract Hyperactivation of the sympathetic nervous system plays a central role in the pathophysiology of hypertension. The aim of this study was to assess cardiac sympathetic activity and investigate the role of myocardial123I-labelled meta-iodo benzyl guanidine ([123I] MIBG) scintigraphy in cardiovascular risk stratification of patients with resistant hypertension treated with renal denervation (RDN). Eighteen patients were included in this prospective study (mean age 56 ± 10 years old, 27.8% females). Transthoracic echocardiogram, general blood analysis and myocardial ([123I] MIBG scintigraphy were performed before and six-months after RDN. A patient was considered a responder (R) if a drop ≥ 5mmHg on mean systolic ambulatory blood pressure (BP) monitoring was observed at the six-month follow-up. 66.7% of patients were R (drop in systolic BP of 20.6 ± 14.5mmHg, vs minus 8 ± 11.6mmHg in non-responders (NR), p=0.001). Early heart-mediastinum ratio (HMR) was significantly lower at baseline in the R group (1.6 ± 0.1 vs 1.72 ± 0.1, p<0.02) but similar at six months. Considering both instants in time, the R group had lower early HMR values than the NR group (p<0.05). Both the late HMR and the washout rate were identical and no significant correlation between response to RDN or any MIBG imaging index was found. Renal denervation effectively lowered blood pressure in the majority of patients but [123I] MIBG was not useful in predicting the response. However, there was evidence of sympathetic overdrive and, both early and late HMR were overall reduced, probably putting this population at a higher risk of adverse events.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Monitoreo Ambulatorio de la Presión Arterial , 3-Yodobencilguanidina , Sistema Nervioso Simpático/diagnóstico por imagen , Estudios Prospectivos , Medición de Riesgo , Radiofármacos , Desnervación , Corazón/fisiología , Corazón/diagnóstico por imagen , Radioisótopos de Yodo , Persona de Mediana Edad
12.
PLoS One ; 16(12): e0261112, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34905585

RESUMEN

The Deepwater Horizon (DWH) oil spill profoundly impacted the health of bottlenose dolphins (Tursiops truncatus) in Barataria Bay, LA (BB). To comprehensively assess the cardiac health of dolphins living within the DWH oil spill footprint, techniques for in-water cardiac evaluation were refined with dolphins cared for by the U.S. Navy Marine Mammal Program in 2018 and applied to free-ranging bottlenose dolphins in BB (n = 34) and Sarasota Bay, Florida (SB) (n = 19), a non-oiled reference population. Cardiac auscultation detected systolic murmurs in the majority of dolphins from both sites (88% BB, 89% SB) and echocardiography showed most of the murmurs were innocent flow murmurs attributed to elevated blood flow velocity [1]. Telemetric six-lead electrocardiography detected arrhythmias in BB dolphins (43%) and SB dolphins (31%), all of which were considered low to moderate risk for adverse cardiac events. Echocardiography showed BB dolphins had thinner left ventricular walls, with significant differences in intraventricular septum thickness at the end of diastole (p = 0.002), and left ventricular posterior wall thickness at the end of diastole (p = 0.033). BB dolphins also had smaller left atrial size (p = 0.004), higher prevalence of tricuspid valve prolapse (p = 0.003), higher prevalence of tricuspid valve thickening (p = 0.033), and higher prevalence of aortic valve thickening (p = 0.008). Two dolphins in BB were diagnosed with pulmonary arterial hypertension based on Doppler echocardiography-derived estimates and supporting echocardiographic findings. Histopathology of dolphins who stranded within the DWH oil spill footprint showed a significantly higher prevalence of myocardial fibrosis (p = 0.003), regardless of age, compared to dolphins outside the oil spill footprint. In conclusion, there were substantial cardiac abnormalities identified in BB dolphins which may be related to DWH oil exposure, however, future work is needed to rule out other hypotheses and further elucidate the connection between oil exposure, pulmonary disease, and the observed cardiac abnormalities.


Asunto(s)
Delfín Mular , Lesiones Cardíacas/veterinaria , Contaminación por Petróleo/efectos adversos , Animales , Delfín Mular/anomalías , Delfín Mular/fisiología , Ecocardiografía/veterinaria , Electrocardiografía/veterinaria , Fibrosis/diagnóstico por imagen , Fibrosis/veterinaria , Corazón/diagnóstico por imagen , Corazón/fisiología , Lesiones Cardíacas/diagnóstico por imagen , Hipertensión/veterinaria
13.
PLoS One ; 16(11): e0258767, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34735475

RESUMEN

BACKGROUND: Chagas disease remains a major cause of cardiovascular death in endemic areas. Focused echocardiography (FoCUS) is a point-of-care means of assessing cardiac function which can be useful for the diagnosis of cardiac involvement. OBJECTIVE: This study aims evaluating the characteristics of validity and reliability of FoCUS applied on Chagas disease patients. METHODS: Patients with Chagas disease coming from an endemic area were selected from a large cohort (SaMi-Trop). A simplified echocardiogram with only three images was extracted from the conventional echocardiogram performed in this cohort. The images were evaluated by an observer who was blinded to the clinical and echocardiographic data, to determine the accuracy and reliability of FoCUS for cardiac assessment. The analysis constituted of 5 prespecified variables, dichotomized in absence or presence: left ventricular (LV) size and systolic function, right ventricular (RV) size and systolic function, and LV aneurysm. RESULTS: We included 725 patients with a mean age of 63.4 ± 12.3 years, 483 (67%) female. Abnormal electrocardiogram was observed in 81.5% of the patients. Left and right ventricular dysfunctions were found in 103 (14%) and 49 (7%) of the patients, respectively. Sensitivity, specificity, positive predictive value and negative predictive value were 84%, 94%, 70% and 97% for LV enlargement and 81%, 93%, 68% and 97% for LV systolic dysfunction, respectively, and 46%, 99%, 60% and 98% for RV dilatation, and 37%, 100%, 100% and 96% for RV dysfunction, respectively. Inter and intraobserver agreement were 61% and 87% for LV enlargement and 63% and 92% for LV dysfunction, respectively, and 50% and 49% for RV size and 46% and 79% for RV dysfunction, respectively. LV apical aneurysm was found in 45 patients (6.2%) with the lowest sensitivity of FoCUS study (11%; 95% CI 2-28%). CONCLUSIONS: FoCUS showed satisfactory values of validity and reliability for assessment of cardiac chambers in patients with Chagas disease, except for apical aneurysm. This tool can identify heart disease with potential impact on patient management in the limited-resource setting.


Asunto(s)
Enfermedad de Chagas/diagnóstico , Ecocardiografía , Corazón/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Derecha/diagnóstico , Anciano , Cardiomiopatía Chagásica/diagnóstico , Cardiomiopatía Chagásica/diagnóstico por imagen , Cardiomiopatía Chagásica/fisiopatología , Enfermedad de Chagas/diagnóstico por imagen , Enfermedad de Chagas/fisiopatología , Femenino , Corazón/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Sístole/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/fisiopatología
14.
Med Biol Eng Comput ; 59(11-12): 2373-2382, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34625862

RESUMEN

An approach recently proposed to assess ultra-rapid patterns of heart rate variability, namely heart rate fragmentation (HRF), is increased in aging and coronary disease. We aimed to evaluate and to correlate HRF with cardiac functional parameters in a rat model of myocardial infarction (MI). Wistar rats were submitted to MI (n = 18) or sham operation (n = 20), and after 4 or 12 weeks, their arterial pressure was recorded. Subsequently, cardiac function was evaluated by echocardiography. From pulse interval series, HRF patterns with zero, one, two, or three inflection points were estimated, as well as the total percentage of inflection points (PIP). Cardiac function was reduced in MI rats. Ejection fraction was smaller 4 (28 ± 3 vs 68 ± 2%, p < 0.0001) and 12 weeks after MI (38 ± 3 vs 70 ± 3%, p < 0.0001). Fractional shortening was also smaller 4 (13 ± 2 vs 41 ± 2%, p < 0.0001) and 12 weeks after MI (20 ± 2 vs 41 ± 3%, p < 0.0001). PIP was increased in MI rats 4 (74 ± 2 vs 69 ± 1%, p = 0.03) and 12 weeks after surgery (70 ± 2 vs 63 ± 1%, p = 0.02). We found a significant negative correlation between cardiac functional parameters and HRF at both 4 and 12 weeks after MI. These findings reveal that MI increases HRF, reinforcing the importance of this approach to explore pathophysiological conditions. Evaluation of heart rate fragmentation (HRF) in a rat model of myocardial infarction (MI). Wistar rats were submitted to MI (n = 18) or sham operation (n = 20), and after 4 or 12 weeks, their arterial pressure was recorded. Cardiac function was evaluated by echocardiography. From pulse interval series, HRF patterns with zero (W0), one (W1), two (W3), or three (W3) inflection points were estimated, as well as the total percentage of inflection points (PIP). Cardiac function was reduced, while PIP was increased in all MI rats. Fluent patterns (W0 and W1) decreased in MI rats after 12 weeks. Altogether, the findings reveal that MI increases HRF, reinforcing the potential of this approach to explore pathophysiological conditions.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Animales , Corazón/diagnóstico por imagen , Frecuencia Cardíaca , Ratas , Ratas Wistar
15.
J Pediatr ; 236: 34-39, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34022248

RESUMEN

OBJECTIVE: To identify the measures of biventricular function and surrogates of pulmonary vascular resistance that can be expected in relatively stable extremely premature neonates, and evaluate maturational changes in myocardial performance in this patient population. STUDY DESIGN: This was a prospective observational study. Clinically stable extremely preterm newborns were divided into 3 cohorts based on gestational age: cohort 1 (240/7-256/7 weeks), cohort 2 (260/7-276/7 weeks), and cohort 3 (280/7-296/7 weeks). Serial echocardiograms were obtained on day of life 3-5, 7-10, and just prior to discharge. RESULTS: In total, 46 subjects met the criteria aimed at capturing only the most clinically healthy and stable newborns less than 296/7 weeks of gestational age. Myocardial performance was reliably assessed by echocardiography with high inter-reader correlation. Normative values were identified for right ventricular function, left ventricular function, and surrogates of pulmonary vascular resistance. CONCLUSIONS: Biventricular systolic performance is significantly different in the clinically stable extremely premature neonate when compared with healthy full-term newborns. All participants had evidence of poor biventricular compliance at birth which improved with maturation. Extreme prematurity does not appear to adversely affect myocardial functional maturation at the time of term corrected age and/or discharge.


Asunto(s)
Corazón/crecimiento & desarrollo , Recien Nacido Extremadamente Prematuro/crecimiento & desarrollo , Recién Nacido/crecimiento & desarrollo , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Factores de Edad , Ecocardiografía , Femenino , Edad Gestacional , Corazón/diagnóstico por imagen , Humanos , Masculino , Estudios Prospectivos , Valores de Referencia , Sístole , Resistencia Vascular/fisiología
16.
BMC Infect Dis ; 21(1): 396, 2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33926389

RESUMEN

BACKGROUND: In the Brazilian Amazon, a new epidemiological profile of Chagas disease transmission, the oral route, has been detected and cited as being responsible for the increase in acute cases in Brazil. The clinical evaluation of acute Chagas disease (ACD) has been a challenge since it can progress to a chronic phase with cardiac alterations, and the follow-up by modern diagnostic methods is very difficult due to the socio-geographical characteristics of the Brazilian Amazon. Thus, alternatives should be sought to alleviate this problem. We conducted a study to evaluate subjects with ACD using the 12-lead ECG QRS score (Selvester score) as an estimative of myocardial injury progression before and after ACD treatment. METHODS: The study included indigenous subjects from the Amazon region with ACD in clinical follow-up at the Fundação de Medicina Tropical Dr. Heitor Vieira Dourado (FMT-HVD) Chagas Disease outpatient clinic in the state of Amazonas, Brazil. The control group consisted of 31 healthy volunteers with no history of heart disease and no reactive serology for Chagas disease. Baseline ECG was performed in all subjects. The Selvester scoring method was performed according to the standardized guide (< 3 points: no myocardial injury,> 3: points × 3% = % of the predicted LV infarction). RESULTS: A total of 62 subjects were included, 31 as cases and 31 as controls. The mean follow-up of the case group was 17 months. The control group presented normal ECG. The case group presented 13 alterations before treatment and 11 after. Nineteen individuals presented scores > 3 points, 6 before and 13 after. In 19.36% of subjects, myocardial injury was found before treatment and in 41.94% after treatment. CONCLUSION: This is the first study that uses the Selvester score (SS) to predict myocardial injury in subjects with ACD. The results of this study suggest the significant presence of myocardial injury from the beginning of treatment to the period post treatment of ACD, which demonstrates that the SS can be applied for stratification and follow-up of Chagas disease in the Amazon region.


Asunto(s)
Enfermedad de Chagas/fisiopatología , Electrocardiografía/métodos , Corazón/fisiopatología , Adulto , Brasil/etnología , Enfermedad de Chagas/complicaciones , Enfermedad de Chagas/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Corazón/diagnóstico por imagen , Humanos , Pueblos Indígenas , Estudios Longitudinales , Masculino , Persona de Mediana Edad
17.
High Blood Press Cardiovasc Prev ; 28(2): 185-249, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33620672

RESUMEN

INTRODUCTION: Systolic blood pressure (SBPA) and pulse pressure amplification (PPA) were quantified using different methodological and calibration approaches to analyze (1) the association and agreement between different SBPA and PPA parameters and (2) the association between these SBPA and PPA parameters and left ventricle (LV) and atrium (LA) structural and functional characteristics. METHODS: In 269 healthy subjects, LV and LA parameters were echocardiography-derived. SBPA and PPA parameters were quantified using: (1) different equations (n = 9), (2) methodological approaches (n = 3): brachial sub-diastolic (Mobil-O-Graph®) and supra-systolic oscillometry (Arteriograph®) and aortic diameter waveform re-calibration (RCD; ultrasonography), and (3) using three different calibration schemes: systo-diastolic (SD), calculated mean (CM) and oscillometric mean (OscM). RESULTS: SBPA and PPA parameters obtained with different equations, techniques, and calibration schemes show a highly variable association level (negative, non-significant, and/or positive) among them. The association between SBPA and PPA with cardiac parameters were highly variable (negative, non-significant, or positive associations). Differences in BPA parameter data between approaches were more sensitive to the calibration method than to the device used. Both, SBPA and PPA obtained with brachial sub-diastolic technique and calibrated to CM or OscM showed higher levels of association with LV and LA structural characteristics. CONCLUSIONS: Our data show that many of the parameters that assume to quantify the same phenomenon of BPA are not related to each other in the different age groups. Both, SBPA and PPA obtained with brachial sub-diastolic technique and calibrated to CM or OscM showed higher levels of association with LV and LA structural characteristics.


Asunto(s)
Función del Atrio Izquierdo , Determinación de la Presión Sanguínea/normas , Presión Sanguínea , Corazón/fisiología , Función Ventricular Izquierda , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Determinación de la Presión Sanguínea/instrumentación , Calibración , Niño , Estudios Transversales , Ecocardiografía Doppler , Femenino , Voluntarios Sanos , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Oscilometría , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
18.
J Anat ; 238(6): 1359-1370, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33491213

RESUMEN

In the human heart, the atrioventricular node is located toward the apex of the triangle of Koch, which is also at the apex of the inferior pyramidal space. It is adjacent to the atrioventricular portion of the membranous septum, through which it penetrates to become the atrioventricular bundle. Subsequent to its penetration, the conduction axis is located on the crest of the ventricular septum, sandwiched between the muscular septum and ventricular component of the membranous septum, where it gives rise to the ramifications of the left bundle branch. In contrast, the bovine conduction axis has a long non-branching component, which penetrates into a thick muscular atrioventricular septum having skirted the main cardiac bone and the rightward half of the non-coronary sinus of the aortic root. It commonly gives rise to both right and left bundle branches within the muscular ventricular septum. Unlike the situation in man, the left bundle branch is long and thin before it branches into its fascicles. These differences from the human heart, however, have yet to be shown in three-dimensions relative to the surrounding structures. We have now achieved this goal by injecting contrast material into the insulating sheaths that surround the conduction network, evaluating the results by subsequent computed tomography. The fibrous atrioventricular membranous septum of the human heart is replaced in the ox by the main cardiac bone and the muscular atrioventricular septum. The apex of the inferior pyramidal space, which in the bovine, as in the human, is related to the atrioventricular node, is placed inferiorly relative to the left ventricular outflow tract. The bovine atrioventricular conduction axis, therefore, originates from a node itself located inferiorly compared to the human arrangement. The axis must then skirt the non-coronary sinus of the aortic root prior to penetrating the thicker muscular ventricular septum, thus accounting for its long non-branching course. We envisage that our findings will further enhance comparative anatomical research.


Asunto(s)
Aorta/diagnóstico por imagen , Sistema de Conducción Cardíaco/diagnóstico por imagen , Corazón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Animales , Bovinos , Humanos , Imagenología Tridimensional , Especificidad de la Especie
19.
Comput Biol Med ; 130: 104200, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33421825

RESUMEN

The use of different cardiac imaging modalities such as MRI, CT or ultrasound enables the visualization and interpretation of altered morphological structures and function of the heart. In recent years, there has been an increasing interest in AI and deep learning that take into account spatial and temporal information in medical image analysis. In particular, deep learning tools using temporal information in image processing have not yet found their way into daily clinical practice, despite its presumed high diagnostic and prognostic value. This review aims to synthesize the most relevant deep learning methods and discuss their clinical usability in dynamic cardiac imaging using for example the complete spatiotemporal image information of the heart cycle. Selected articles were categorized according to the following indicators: clinical applications, quality of datasets, preprocessing and annotation, learning methods and training strategy, and test performance. Clinical usability was evaluated based on these criteria by classifying the selected papers into (i) clinical level, (ii) robust candidate and (iii) proof of concept applications. Interestingly, not a single one of the reviewed papers was classified as a "clinical level" study. Almost 39% of the articles achieved a "robust candidate" and as many as 61% a "proof of concept" status. In summary, deep learning in spatiotemporal cardiac imaging is still strongly research-oriented and its implementation in clinical application still requires considerable efforts. Challenges that need to be addressed are the quality of datasets together with clinical verification and validation of the performance achieved by the used method.


Asunto(s)
Aprendizaje Profundo , Técnicas de Imagen Cardíaca , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética
20.
Int J Comput Assist Radiol Surg ; 16(1): 65-79, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33196972

RESUMEN

PURPOSE: This paper presents CardIAc, an open-source application designed as an alternative to commercial software for left ventricle myocardial strain quantification in short-axis cardiac magnetic resonance images. The aim is to provide a useful extension for myocardial strain analysis that can be easily adapted to incorporate different strategies of motion tracking to improve the strain accuracy. In this way, users with programming skills can easily modify the code and adjust the program's performance according to their own scientific or clinical requirements. The software is intended for research and clinical use is not advised. METHODS: CardIAc was developed as a 3D Slicer extension for an easy installation and usability. The main contribution of this article is to provide a general workflow, going from data and segmentation loading, 3D heart modeling, analysis and several options for visualization of the myocardial strain. RESULTS: CardIAc strain feature was evaluated on a public dataset (Cardiac Motion Analysis Challenge-STACOM 2011) of 15 volunteers, and a synthetic one generated from this real dataset. Results on the real dataset show that cardIAc achieves suitable accuracy for myocardial motion estimation with a median error of 3.66 mm. In particular, global strain curves show strong correlation with the bibliography for healthy patients and similar approaches. On the other hand, results on the synthetic dataset show a mean global error of 4.07%, 7.76% and 8.18% for circumferential, radial and longitudinal strain. CONCLUSION: This paper introduces a new open-source application for strain analysis distributed under a BSD-style open-source license. Results demonstrate the capability and merits of the proposed application for strain analysis.


Asunto(s)
Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Miocardio , Programas Informáticos , Función Ventricular Izquierda/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Modelos Cardiovasculares , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA