Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33.855
Filtrar
1.
Biomaterials ; 313: 122810, 2025 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39243673

RESUMEN

The development of biosensing electronics for real-time sweat analysis has attracted increasing research interest due to their promising applications for non-invasive health monitoring. However, one of the critical challenges lies in the sebum interference that largely limits the sensing reliability in practical scenarios. Herein, we report a flexible epidermal secretion-purified biosensing patch with a hydrogel filtering membrane that can effectively eliminate the impact of sebum and sebum-soluble substances. The as-prepared sebum filtering membranes feature a dual-layer sebum-resistant structure based on the poly(hydroxyethyl methacrylate) hydrogel functionalized with nano-brush structured poly(sulfobetaine) to eliminate interferences and provide self-cleaning capability. Furthermore, the unidirectional flow microfluidic channels design based on the Tesla valve was incorporated into the biosensing patch to prevent external sebum contamination and allow effective sweat refreshing for reliable sensing. By seamlessly combining these components, the epidermal secretion-purified biosensing patch enables continuous monitoring of sweat uric acid, pH, and sodium ions with significantly improved accuracy of up to 12 %. The proposed strategy for enhanced sweat sensing reliability without sebum interference shows desirable compatibility for different types of biosensors and would inspire the advances of flexible and wearable devices for non-invasive healthcare.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Sebo , Sudor , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Humanos , Sebo/metabolismo , Hidrogeles/química , Sudor/química , Epidermis/metabolismo , Dispositivos Electrónicos Vestibles , Microfluídica/métodos , Ácido Úrico/análisis , Membranas Artificiales , Concentración de Iones de Hidrógeno
2.
Int J Gen Med ; 17: 3755-3764, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39219672

RESUMEN

Background: The relationship between pulmonary hypertension (PH) and outcomes after transcatheter aortic valve replacement (TAVR) has been shown to be unfavorable. The impact of gender on TAVR outcomes remains controversial. There have been no studies evaluating the simultaneous effects of both factors on TAVR outcomes. Methods: We retrospectively analyzed a prospective cohort of patients who underwent TAVR between January 2016 and December 2022. The patients were stratified by gender and the presence of PH. The primary outcome of the study was all-cause mortality. Secondary outcome was a composite of all-cause mortality and heart failure hospitalization. Results: We identified a total of 133 female patients without PH, 179 males without PH, 87 females with PH, and 122 males with PH. The median follow-up period was 18 months. Female patients without PH demonstrated a lower cumulative mortality rate compared to those with male gender and/or PH. Adjusted multivariate Cox proportional hazard analyses revealed that male gender and PH status, either individually or in combination, were independently associated with long-term mortality when compared to female patients without PH. Specifically, females with PH (HR 6.80, 95% confidence interval (CI): 1.49-31.12, P=0.013), males without PH (HR 6.45, 95% CI: 1.47-28.22, P=0.013), and males with PH (HR 7.2, 95% CI: 1.63-31.81, P=0.009) demonstrated significantly higher risk for mortality. Conclusion: Patients who were male or had PH status had a higher risk of mortality. However, there was no synergistic effect between being male and having PH on the prognosis after TAVR.

3.
Clin Case Rep ; 12(9): e9352, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39219785

RESUMEN

Key Clinical Message: Recurrence of valvular involvement may occur after Libman-Sacks endocarditis surgery, emphasizing the need for frequent multivalvular evaluations with echocardiography or more sensitive methods to optimize surgical outcomes. Abstract: This report presented a 32-year-old woman, complaining of recurrent fever and chills. Physical examination revealed the presence of a third heart sound (S3), a pan-systolic murmur (III/VI) at mitral and tricuspid foci, tachycardia, and fine pulmonary crackles. Transesophageal echocardiography (TEE) revealed severe mitral regurgitation (MR) and moderate tricuspid regurgitation (TR) with vegetations on the mitral valve. Initially, intravenous antibiotic therapy was started simultaneously with diagnostic studies. Despite a positive TEE, negative blood cultures on three separate occasions precluded meeting the diagnostic criteria outlined in the modified Duke criteria. Moreover, the patient's condition continued to deteriorate after antibiotic therapy, leading to the diagnosis of Libman-Sacks endocarditis. The patient was considered a candidate for mitral valve surgery. All vegetations were completely debrided and then the mitral valve was reconstructed. Follow-up post-surgery echocardiography revealed the absence of MR and mitral stenosis (MS). Four months later, the patient presented again complaining of fatigue, dyspnea, lower extremity edema, and ascites with evidence of pulmonary hypertension and right heart failure on physical examination. TEE was performed, which revealed severe MR, severe TR, detached artificial chordae, and blood leak from the perforated pericardial patch. Therefore, she was necessitated for valvular surgery and underwent mitral and tricuspid valve surgery. The mitral ring and perforated pericardial patch were removed, and a mitral prosthetic valve was implanted. In addition, the tricuspid valve was repaired. Follow-up post-surgery echocardiography revealed the absence of MR and TR. To our knowledge, this is the first case of LSE recurrence with multi-valvular involvement.

4.
IDCases ; 37: e02052, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220422

RESUMEN

Escherichia coli (E. coli) is a facultative anaerobic gram-negative rod bacterium, which can acquire pathogenicity through the acquisition of additional genetic material. We present a case of E. coli ST1193, an emerging global multidrug-resistant (MDR) high-risk clone, causing native valve endocarditis and septic brain and splenic emboli in a 67-year-old woman.

5.
Regen Biomater ; 11: rbae084, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220742

RESUMEN

For patients with symptomatic and severe tricuspid regurgitation but inoperable with open surgery, transcatheter tricuspid valve intervention (TTVI) is a procedure of great clinical value. TTVI products include repair and replacement devices. TTVI products are one of the hotspots of investigation now, with different innovative biomaterials and structural designs in trials to satisfy divergent indications and reduce complications. With the emerging biomaterials, the technical difficulty of structural design will be greatly reduced, spurring further product innovation and development. The innovativeness and complexity of TTVI products have brought challenges to academia, industry, and regulatory agencies. Regulatory science provides a bridge to address these difficulties and challenges. This perspective article introduces the latest development of the TTVI products. With traditional methods, regulatory agencies face challenges in evaluating the safety and efficacy of TTVr/TTVR devices given the uncertainty of clinical use and the diversity of innovative structural design. This perspective article analyzes the regulatory challenges and discusses regulatory science that can be developed to assess the safety, efficacy, quality and performance of such products: including new approaches for innovative devices, pre-review path, computer modeling and simulation, accelerated wear testing methods for transcatheter heart valves and evidence-based research. This article reveals for the first time how to apply regulatory science systematically to TTVI products, which is of great relevance to their development and translation.

6.
Front Vet Sci ; 11: 1441839, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220767

RESUMEN

Introduction: Left atrial volume (LAV) obtained using real-time three-dimensional echocardiography (RT3DE) is an independent predictor of post-capillary pulmonary hypertension (PH) in humans; however, no studies have investigated LAV obtained using RT3DE as a predictor of post-capillary PH in dogs with myxomatous mitral valve disease (MMVD). Therefore, we aimed to evaluate the clinical applicability of LAV obtained using RT3DE compared to that obtained using two-dimensional echocardiography (2DE) in dogs with MMVD, with or without PH. Methods: Medical records and echocardiographic images of 237 privately owned dogs with naturally occurring MMVD with or without PH were retrospectively reviewed. A total of 49 privately owned dogs with naturally occurring MMVD, with or without PH, were finally included (35 MMVD without PH, 14 MMVD with PH). The LAV and left ventricular volumes were obtained using 2DE and RT3DE. Echocardiographic parameters were analyzed to identify independent predictors of post-capillary PH. Results: We found that the left atrial and left ventricular volumes obtained using 2DE and RT3DE indexed to body weight and several 2DE-derived variables were univariately associated with post-capillary PH. Furthermore, multivariable logistic regression analysis revealed that the RT3DE minimum LAV indexed to body weight (LAVi min) was the only significant independent predictor of post-capillary PH (odds ratio, 12.86; 95% confidence interval [CI], 2.40-68.99; p = 0.003), with the highest area under the curve value of 0.86 (95% CI, 0.75-0.96; p < 0.001). Discussion: In conclusion, LAV indexed to body weight obtained using 2DE and RT3DE, can be a useful predictor of post-capillary PH in dogs with MMVD. In particular, the RT3DE LAVi min was observed to be the strongest predictor of post-capillary PH.

9.
Interv Cardiol ; 19: e12, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39221063

RESUMEN

The demonstrated safety and effectiveness of transcatheter aortic valve implantation (TAVI) among low surgical risk patients opened the road to its application in younger low-risk patients. However, the occurrence of conduction abnormalities and need for permanent pacemaker implantation remains a frequent problem associated with adverse outcomes. The clinical implications may become greater when TAVI shifts towards younger populations, highlighting the need for comprehensive strategies to address this issue. Beyond currently available clinical and electrocardiographic predictors, patient-specific anatomical assessment of the aortic root using multi-sliced CT (MSCT) imaging can refine risk stratification. Moreover, leveraging MSCT data for computational 3D simulations to predict device-anatomy interactions may help guide procedural strategy to mitigate conduction abnormalities. The aims of this review are to summarise the incidence and clinical impact of new left bundle branch block and permanent pacemaker implantation post-TAVI using contemporary transcatheter heart valves; and highlight the value of MSCT data interpretation to improve the management of this complication.

10.
World J Cardiol ; 16(8): 436-447, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39221189

RESUMEN

Coronary heart disease and aortic stenosis are prevalent cardiovascular diseases worldwide, leading to morbidity and mortality. Coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) have therapeutic benefits, including improved postoperative quality of life (QoL) and enhanced patient functional capacity which are key indicators of cardiac surgery outcome. In this article, we review the latest studies of QoL outcomes and functional capacity in patients who underwent cardiac surgery. Many standardized instruments are used to evaluate QoL and functional conditions. Preoperative health status, age, length of intensive care unit stay, operative risk, type of procedure, and other pre-, intra-, and postoperative factors affect postoperative QoL. Elderly patients experience impaired physical status soon after cardiac surgery, but it improves in the following period. CABG and SAVR are associated with increases of physical and mental health and functional capacity in the immediate postoperative and the long long-term. Cardiac rehabilitation improves patient functional capacity, QoL, and frailty following cardiac surgery.

11.
Mater Today Bio ; 28: 101194, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39221196

RESUMEN

Valvular heart diseases (VHDs) have become one of the most prevalent heart diseases worldwide, and prosthetic valve replacement is one of the effective treatments. With the fast development of minimal invasive technology, transcatheter valves replacement has been exploring in recent years, such as transcatheter aortic valve replacement (TAVR) technology. In addition, basic research on prosthetic valves has begun to shift from traditional mechanical valves and biological valves to the development of polymeric heart valves. The polymeric heart valves (PHVs) have shown a bright future due to their advantages of longer durability, better biocompatibility and reduced cost. This review gives a brief history of the development of polymeric heart valves, provides a summary of the types of polymer materials suitable for heart leaflets and the emerging processing/preparation methods for polymeric heart valves in the basic research. Besides, we facilitate a deeper understanding of polymeric heart valve products that are currently in preclinical/clinical studies, also summary the limitations of the present researches as well as the future development trends. Hence, this review will provide a holistic understanding for researchers working in the field of prosthetic valves, and will offer ideas for the design and research of valves with better durability and biocompatibility.

12.
Artículo en Inglés | MEDLINE | ID: mdl-39223348

RESUMEN

Frailty assessment is essential for deciding the treatment strategy for patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Recently, the revised Japanese version of the Cardiovascular Health Study (J-CHS) criteria has been proposed for the frailty assessment; however, it is unclear whether the criteria are useful for the risk stratification in these patients. We investigated the impact of frailty assessment using the revised J-CHS criteria on clinical outcomes in patients with AS undergoing TAVR. We examined 205 consecutive severe AS patients who underwent TAVR at two tertiary hospitals from May 2018 to December 2022. Frailty was defined by the revised J-CHS criteria (score ≥ 3) before TAVR. The primary outcome was major adverse cardiac or cerebrovascular events (MACCE). Among the studied patients, the mean age was 84 years and 65% were female. Frailty was present in 51% of patients. During a median follow-up period of 1000 (interquartile range 677-1210) days, MACCE occurred in 22 patients. Frailty was significantly independently associated with higher risks of the MACCE adjusted for confounders related to nutritional status, severity of AS, comorbidities [hazard ratio (HR) 5.09, 95% confidence interval (CI) 1.70-15.23; HR 3.94, 95% CI 1.34-11.55; HR 3.12, 95% CI 1.14-8.53; HR 3.31, 95% CI 1.21-9.02, respectively]. Frailty determined by the revised J-CHS criteria was associated with clinical outcomes, suggesting these criteria would be useful for risk stratification in Japanese patients with AS undergoing TAVR.

13.
Artículo en Inglés | MEDLINE | ID: mdl-39224002

RESUMEN

Coronary obstruction (CO) is a potential pitfall for transcatheter aortic valve replacement (TAVR), especially in valve in valve procedures into degenerated surgical or transcatheter prostheses. Bioprosthetic leaflet modification techniques that incorporate electrosurgery are evolving as the preferred strategy to mitigate the risk of CO in high CO risk settings. The UNICORN method is proposed as a more predictable leaflet modification strategy than the earlier described BASILICA approach, but its proponents have hitherto mandated the use of a balloon-expandable valve (BEV) prosthesis. Many patients have small prostheses and therein face a significant risk of patient prosthesis mismatch with BEV in this setting. This risk may be curtailed if a self-expanding valve (SEV) prosthesis could be used. Herein described is a modified approach to allow for the utilization of SEV systems in this setting.

15.
Ann Biomed Eng ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225853

RESUMEN

The Ozaki procedure is a surgical technique which avoids to implant foreign aortic valve prostheses in human heart, using the patient's own pericardium. Although this approach has well-identified benefits, it is still a topic of debate in the cardiac surgical community, which prevents its larger use to treat valve pathologies. This is linked to the actual lack of knowledge regarding the dynamics of tissue deformations and surrounding blood flow for this autograft pericardial valve. So far, there is no numerical study examining the coupling between the blood flow characteristics and the Ozaki leaflets dynamics. To fill this gap, we propose here a comprehensive comparison of various performance criteria between a healthy native valve, its pericardium-based counterpart, and a bioprosthetic solution, this is done using a three-dimensional fluid-structure interaction solver. Our findings reveal similar physiological dynamics between the valves but with the emergence of fluttering for the Ozaki leaflets and higher velocity and wall shear stress for the bioprosthetic heart valve.

16.
JACC Adv ; 3(9): 101212, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39253713

RESUMEN

Background: Periprocedural myocardial injury impacts clinical outcome after transcatheter aortic valve replacement (TAVR). The optimal medical management strategy for TAVR-related periprocedural myocardial injury has not been established. Objectives: The authors aimed to investigate the prognostic association of renin-angiotensin system (RAS) inhibitors in patients with periprocedural myocardial injury after TAVR. Methods: In a prospective TAVR registry, patients were retrospectively stratified according to Valve Academic Research Consortium (VARC)-3 periprocedural myocardial injury and RAS inhibitor prescription after TAVR. The main outcomes of interest were prevalence of myocardial injury and cardiovascular death. Logistic and Cox proportional hazards regression were used to analyze outcomes of interest. Results: Among 2,083 eligible patients undergoing TAVR between August 2007 and June 2023, 283 patients (13.8%) developed VARC-3 periprocedural myocardial injury. RAS inhibitors were prescribed in 197 patients (70%) with periprocedural myocardial injury and in 1,251 patients (71.2%) without injury. Compared with patients without periprocedural myocardial injury, patients with myocardial injury had an increased risk of cardiovascular death at 1 year (HRadjusted: 2.08; 95% CI: 1.39-3.11). The use of RAS inhibitors after TAVR was associated with a reduced risk of cardiovascular death in patients with and without periprocedural myocardial injury (HRadjusted: 0.46; 95% CI: 0.22-0.95, and HRadjusted: 0.44; 95% CI: 0.30-0.65, respectively). Conclusions: One out of 7 patients undergoing TAVR experienced periprocedural myocardial injury. VARC-3 periprocedural myocardial injury was associated with a 2-fold increased risk of cardiovascular death at 1 year after TAVR. The favorable association of RAS inhibitor prescription was consistent in patients with and without periprocedural myocardial injury. (SwissTAVI Registry; NCT01368250).

17.
Amyloid ; : 1-7, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39255059

RESUMEN

BACKGROUND: To compare the efficacy of modified Ex-PRESS technique (ExP) versus Ahmed Glaucoma Valve (AGV) as primary surgery in hereditary transthyretin amyloidosis (ATTRv) secondary glaucoma. METHODS: Retrospective study at the national amyloidosis centre. Success was defined as an IOP ≥ 6 mmHg and ≤ 21 mmHg with no need for further glaucoma surgery or laser trabeculoplasty and without loss of light perception at the time of the last follow-up. Secondary outcomes included surgical complications, need for hypotensive drugs, and endothelial cell loss. Patients submitted to previous glaucoma surgery were excluded. RESULTS: We included 180 eyes of 150 patients, 121 in AGV and 59 in ExP group. No significant baseline differences were found between groups. At the time of last follow-up, both groups exhibited significant intraocular pressure (IOP) reduction (p < .001) and number of glaucoma medications (p < .001). Kaplan-Meyer analysis showed higher cumulative probability of success for AGV group (80.1% vs. 41.1%, p < .001) and higher mean time to failure (54.5 vs. 36.9 months, respectively, p < 0.001) at 60 months follow-up. AGV showed lower hazard (HR 0.21, 95% CI [0.111-0.407], p < .001) for failure. CONCLUSION: AGV and ExP are safe and effective techniques in the treatment of ATTRv secondary glaucoma. However, AGV's efficacy seems to be more durable.

18.
Clin Res Cardiol ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256220

RESUMEN

BACKGROUND AND OBJECTIVE: Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with symptomatic severe aortic stenosis across all stages of surgical risk. Rapid pacing during the procedure and the risk for the occurrence of conduction disturbances after TAVR requires the pre-interventional insertion of a temporary pacemaker (TP). However, this approach poses risks, including the risk of infection. For this reason, the following study aimed to investigate microbial growth on temporary pacemaker leads and its association with outcome post-TAVR and to identify associated pathogens and related risk factors. METHODS: A prospective study was conducted including 344 patients undergoing TAVR at the Heart Centre Bonn. Of these, 97 patients did not require TP leads as they already had permanent pacemakers; this group was considered as comparison group. The TP leads of the remaining 247 patients were removed, sonicated, and cultured to investigate bacterial growth over a period of 14 days. Finally, we compared patients without microbial growth (n = 184) and patients with microbial growth (n = 63). The primary endpoint of the study was 30-day all-cause mortality, secondary endpoints were periprocedural infections, the length of the postprocedural hospital stay, 30-day major vascular complications and the 30-day stroke rate. RESULTS: The majority of cases (74.5%) showed no bacterial growth. In the remaining cases (25.5%), diverse microorganisms were identified, mostly non-pathogenic bacteria. The statistical analysis revealed no significant differences between groups according to microbial growth in terms of 30-day mortality (p = 0.446), postprocedural hospital stay (p = 0.401), periprocedural infections (p = 0.434), 30-day major vascular complications (p = 1.0), and 30-day stroke rate (p = 1.0). Notably, the timing of sheath insertion was significantly associated with microbial growth; sheath placement more than 2 days prior to the procedure was associated with a significantly higher risk of microbial growth (OR: 2.1; 95% CI 1.1-4.3) (p = 0.030). CONCLUSIONS: The presence of temporary leads does not significantly impact clinical outcomes, irrespective of bacterial growth on the lead. However, the timing and duration of sheath placement plays a crucial role in contamination incidence. Thus, temporary leads/sheaths should be placed shortly before the procedure and removed promptly to reduce the risk of contamination/infection.

19.
Am J Med Genet A ; : e63873, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39257254

RESUMEN

The recurrent chromosome 16p11.2 BP4-BP5 microdeletion (MIM #611913) predisposes to a neurodevelopmental disorder with variable associated congenital anomalies and susceptibility to early-onset obesity. We identified 22 new individuals with proximal 16p11.2 deletions through retrospective data analysis at our institution and performed phenotyping through in-depth chart review. Our cohort exhibited a spectrum of neurodevelopmental abnormalities largely consistent with other publications, however they also were found to have a higher rate than expected of congenital anomalies, some of which have not yet been reported in association with 16p11.2 microdeletions to our knowledge. This series contributes to the body of data on this population, which we anticipate will continue to evolve along with increased uptake of genetic testing.

20.
Artículo en Inglés | MEDLINE | ID: mdl-39257293

RESUMEN

BACKGROUND: Bleeding and stroke are frequent complications after transcatheter aortic valve implantation (TAVI). The mortality risk associated with these events has been reported before, but data regarding their impact on health-related quality of life (QoL) is limited. AIM: To evaluate the impact of bleeding and stroke occurring within 30 days after TAVI, on mortality and QoL during the first year after TAVI. METHODS: POPular TAVI was a randomized clinical trial that evaluated the addition of clopidogrel to aspirin or oral anticoagulation in patients undergoing TAVI. Besides clinical outcomes, QoL was assessed using the Short Form-12 and EuroQoL Five Dimensions questionnaires before, and at 3, 6, and 12 months after TAVI. RESULTS: Major or life-threatening bleeding occurred in 81 patients (8.3%) and was associated with an increased risk of death (hazard ratio [HR] 1.95 [95% confidence interval (CI) 1.00-3.79]); minor bleeding occurred in 104 patients (10.6%) and was not associated with mortality (HR 0.75 [95% CI 0.30-1.89]). Stroke occurred in 35 patients (3.6%) and was associated with an increased risk of death (HR 2.90 [95% CI 1.23-6.83]). Mean mental component summary (MCS-12) scores over time were lower in patients with major or life-threatening bleeding (p = 0.01), and similar in patients with minor bleeding, compared to patients without bleeding; mean physical component summary (PCS-12) scores, EQ-5D index, and visual analog scale (VAS) were similar between those patients. Mean MCS-12 scores were lower in patients with stroke (p = 0.01), mean PCS-12, EQ-5D index, and VAS were similar compared to patients without stroke. CONCLUSION: Major or life-threatening bleeding and stroke were associated with an increased risk of death and decreased mental QoL in the first year after TAVI.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA