Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Drug Deliv Rev ; 212: 115420, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39096937

RESUMEN

The evaluation of the diffusion properties of different molecules in tissues is a subject of great interest in various fields, such as dermatology/cosmetology, clinical medicine, implantology and food preservation. In this review, a discussion of recent studies that used kinetic spectroscopy measurements to evaluate such diffusion properties in various tissues is made. By immersing ex vivo tissues in agents or by topical application of those agents in vivo, their diffusion properties can be evaluated by kinetic collimated transmittance or diffuse reflectance spectroscopy. Using this method, recent studies were able to discriminate the diffusion properties of agents between healthy and diseased tissues, especially in the cases of cancer and diabetes mellitus. In the case of cancer, it was also possible to evaluate an increase of 5% in the mobile water content from the healthy to the cancerous colorectal and kidney tissues. Considering the application of some agents to living organisms or food products to protect them from deterioration during low temperature preservation (cryopreservation), and knowing that such agent inclusion may be reversed, some studies in these fields are also discussed. Considering the broadband application of the optical spectroscopy evaluation of the diffusion properties of agents in tissues and the physiological diagnostic data that such method can acquire, further studies concerning the optimization of fruit sweetness or evaluation of poison diffusion in tissues or antidote application for treatment optimization purposes are indicated as future perspectives.


Asunto(s)
Neoplasias , Humanos , Difusión , Animales , Neoplasias/metabolismo , Luz , Análisis Espectral/métodos , Diabetes Mellitus/metabolismo
2.
Biosensors (Basel) ; 14(8)2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39194614

RESUMEN

A label-free biosensor based on a tunable MEMS metamaterial structure is proposed in this paper. The adopted structure is a one-dimensional array of metamaterial gratings with movable and fixed fingers. The moving unit of the optical detection system is a component of the MEMS structure, driven by the surface stress effect. Thus, these suspended optical nanoribbons can be moved and change the grating pattern by the biological bonds that happened on the modified cantilever surface. Such structural variations lead to significant changes in the optical response of the metamaterial system under illuminating angled light and subsequently shift its resonance wavelength spectrum. As a result, the proposed biosensor shows appropriate analytical characteristics, including the mechanical sensitivity of Sm = 11.55 µm/Nm-1, the optical sensitivity of So = Δλ/Δd = 0.7 translated to So = Δλ/Δσ = 8.08 µm/Nm-1, and the quality factor of Q = 102.7. Also, considering the importance of multi-biomarker detection, a specific design of the proposed topology has been introduced as an array for identifying different biomolecules. Based on the conducted modeling and analyses, the presented device poses the capability of detecting multiple biomarkers of disease at very low concentrations with proper precision in fluidic environments, offering a suitable bio-platform for lab-on-chip structures.


Asunto(s)
Biomarcadores , Técnicas Biosensibles , Sistemas Microelectromecánicos , Humanos , Dispositivos Laboratorio en un Chip
3.
Sensors (Basel) ; 24(5)2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38474902

RESUMEN

Underwater optical imaging for information acquisition has always been an innovative and crucial research direction. Unlike imaging in the air medium, the underwater optical environment is more intricate. From an optical perspective, natural factors such as turbulence and suspended particles in the water cause issues like light scattering and attenuation, leading to color distortion, loss of details, decreased contrast, and overall blurriness. These challenges significantly impact the acquisition of underwater image information, rendering subsequent algorithms reliant on such data unable to function properly. Therefore, this paper proposes a method for underwater image restoration using Stokes linearly polarized light, specifically tailored to the challenges of underwater complex optical imaging environments. This method effectively utilizes linear polarization information and designs a system that uses the information of the first few frames to calculate the enhanced images of the later frames. By doing so, it achieves real-time underwater Stokes linear polarized imaging while minimizing human interference during the imaging process. Furthermore, the paper provides a comprehensive analysis of the deficiencies observed during the testing of the method and proposes improvement perspectives, along with offering insights into potential future research directions.

4.
Neurosurg Rev ; 47(1): 81, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355824

RESUMEN

Tremor, bradykinesia, and rigidity are incapacitating motor symptoms that can be suppressed with stereotactic neurosurgical treatment like deep brain stimulation (DBS) and ablative surgery (e.g., thalamotomy, pallidotomy). Traditionally, clinicians rely on clinical rating scales for intraoperative evaluation of these motor symptoms during awake stereotactic neurosurgery. However, these clinical scales have a relatively high inter-rater variability and rely on experienced raters. Therefore, objective registration (e.g., using movement sensors) is a reasonable extension for intraoperative assessment of tremor, bradykinesia, and rigidity. The main goal of this scoping review is to provide an overview of electronic motor measurements during awake stereotactic neurosurgery. The protocol was based on the PRISMA extension for scoping reviews. After a systematic database search (PubMed, Embase, and Web of Science), articles were screened for relevance. Hundred-and-three articles were subject to detailed screening. Key clinical and technical information was extracted. The inclusion criteria encompassed use of electronic motor measurements during stereotactic neurosurgery performed under local anesthesia. Twenty-three articles were included. These studies had various objectives, including correlating sensor-based outcome measures to clinical scores, identifying optimal DBS electrode positions, and translating clinical assessments to objective assessments. The studies were highly heterogeneous in device choice, sensor location, measurement protocol, design, outcome measures, and data analysis. This review shows that intraoperative quantification of motor symptoms is still limited by variable signal analysis techniques and lacking standardized measurement protocols. However, electronic motor measurements can complement visual evaluations and provide objective confirmation of correct placement of the DBS electrode and/or lesioning. On the long term, this might benefit patient outcomes and provide reliable outcome measures in scientific research.


Asunto(s)
Estimulación Encefálica Profunda , Procedimientos Neuroquirúrgicos , Humanos , Estimulación Encefálica Profunda/métodos , Hipocinesia , Resultado del Tratamiento , Temblor/diagnóstico , Temblor/cirugía , Vigilia
5.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38400410

RESUMEN

We describe a method for reducing the cost of optical frequency domain reflectometer (OFDR) hardware by replacing two reference channels, including an auxiliary interferometer and a gas cell, with a single channel. To extract useful information, digital signal processing methods were used: digital frequency filtering, as well as empirical mode decomposition. It is shown that the presented method helps to avoid the use of an unnecessary analog-to-digital converter and photodetector, while the OFDR trace is restored by the equal frequency resampling (EFR) algorithm without loss of high resolution and with good measurement repeatability.

6.
Sensors (Basel) ; 23(21)2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37960595

RESUMEN

This paper focuses on the experimental characterization of the polarization behavior of light backscattered through fog. A polarimetric orthogonal state contrast imager and an active, purely polarized white illuminator system are used to evaluate both linear and circular polarization signals. The experiments are carried out in a macro-scale fog chamber under controlled artificial fog conditions. We explore the effect of backscattering in each imaging channel, and the persistence of both polarization signals as a function of meteorological visibility. We confirm the presence of the polarization memory effect with circularly polarized light, and, as a consequence, the maintenance of helicity in backscattering. Moreover, the circular cross-polarized channel is found to be the imaging channel less affected by fog backscattering. These results are useful and should be taken into account when considering active polarimetric imaging techniques for outdoor applications under foggy conditions.

7.
Materials (Basel) ; 15(24)2022 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-36556681

RESUMEN

A material strength investigation along with a detailed microfractography analysis of fractures formed during static tensile tests of steel Armstal 550 was performed. The tests in this research were conducted in a temperature range of 298 to 973 K. In addition, during tensile tests at ambient temperature, optical measurements of strain maps and the curvature of the neck were performed. The minimum cross-sectional diameter and the radius of the neck curvature during tensile tests were obtained. The data can be directly used to obtain the true stress-strain curve. The material property analysis confirmed the high strength of the Armstal 550 alloy. The ultimate strength at room temperature equals 2.14 GPa, whereas the yield point equals 1.65 GPa. A decrease in the strength parameters along with an increase in temperature was noted. This is a typical phenomenon related to a change in the density and thermal expansion of steel under the influence of the temperature increase. For example, at a temperature of 500 °C, the ultimate strength is more than 50% less than at room temperature. An in-depth analysis of the metallography and microfractography of fractures resulting from static tensile tests showed the formation of atypical nano- and microstructures with an elongated shape. Local nano- and microstructures were observed at different levels of intensity for different temperatures. The largest clusters of nanoparticles were present on the surfaces of the specimens examined at a temperature of 973 K. Scanning microscopy analysis confirmed the presence of molybdenum oxides.

8.
Sensors (Basel) ; 22(16)2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36015793

RESUMEN

Proper measurements are extremely significant for the forest owner, the harvesting company, the hauler, the final buyer, and the wood processing company. The accuracy of round wood volume determination is of fundamental importance in planning and accounting for individual processes related to the wood trade. It is the basis for determining the maximum quantity in single load of wood that allows for using the permissible total gross vehicle weight. The determination of wood load in cubic meters does not allow unequivocally determining its weight, which often leads to overloading of vehicles. This paper presents a comparison of the photo-optical method for determining the volume of wood to be transported with the real measurement and determination of the weight of a load and the total gross vehicle weight (GVW) with the simultaneous application of conversion factors determining the weight of the load from the volume of wood. The measurement included 23 broadleaf round wood piles (193.73 m3) and 14 coniferous round wood piles (149.23 m3). The measurement error for broadleaf wood piles ranges from -47.67% to 63.16%, and from -43.31% to 24.72% for coniferous wood piles. Determination of the volume of a broadleaf wood pile using the iFOVEA method had an average error of 1.34%, while the Timbeter method had an average error of -1.83%. In the coniferous wood pile measurement, the error is -12.82% and 2.41%, respectively. Verification of the volume of the large-sized wood indicated on the delivery note (reference value) on the log sorting line (by laser scanning) showed larger volumes by 0.10 m3 to 2.54 m3, giving a percentage error of 0.35% and 8.62%, respectively. As a consequence of the application of such methods for determining the weight of wood loads, the transport truck sets are often significantly overloaded, which has a significant impact on the accelerated degradation of roads and safety in traffic and timber transportation.


Asunto(s)
Tracheophyta , Madera , Vehículos a Motor , Transportes
9.
Materials (Basel) ; 15(12)2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35744187

RESUMEN

Multisensor CMMs are systems with an established position on the market, but their popularity still grows, as they provide access to the advantages offered by tactile and contactless measurement methods. Yet there are still questions of the comparability of results obtained using the optical and tactile operation modes of multisensor system. This phenomenon can be assessed by measuring appropriate gauges, most often reference rings or spheres. Due to the completely different nature of probing processes for tactile and contactless measurements, the material from which reference object is made may significantly affect measurement results. In order to assess the influence of this factor on measurement accuracy, three reference spheres made from different materials were measured on optical multisensor CMMs. Measurements involved tactile measurements as well as optical measurements made using different probing systems: a video probe and white light sensor. Results obtained from performed experiments show large differences depending on the material used for spherical standard production. On the basis of obtained results, it can be stated that the best material for a reference object that can be used for comparability tests of tactile and optical measurements is a composite of alumina with at least one oxidic additive.

10.
Ultrason Sonochem ; 83: 105950, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35151987

RESUMEN

The present work addresses the correlation of bisphenol A (BPA) degradation by hydrodynamic cavitation with the fluid mechanical properties of the cavitating jet in the reactor. The effects of inlet pressure and two orifices were investigated. The fluid mechanics conditions during the reaction were evaluated by optical measurements to determine the jet length, bubble volume, number of bubbles, and bubble size distribution. In addition, chemiluminescence of luminol is used to localize chemically active bubbles due to the generation of hydroxyl radicals in the reactor chamber. The correlation between the rate constants of BPA degradation and the mechanical properties of the liquid is discussed. Here, linear dependencies between the degradation of BPA and the volume expansion of the bubble volume and chemiluminescence are found, allowing prediction of the rate constants and the hydroxyl radicals generated. BPA degradation of 50% was achieved in 30 min with the 1.7 mm nozzle at 25 bar. However, the 1 mm nozzle has been demonstrated to be more energetically efficient, achieving 10% degradation with 30% less power per 100 passes. There is a tendency for the number of small bubbles in the reactor to increase with smaller nozzle and increasing pressure difference.


Asunto(s)
Hidrodinámica , Agua , Compuestos de Bencidrilo , Fenoles
11.
Materials (Basel) ; 14(23)2021 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-34885614

RESUMEN

Sash gang saws with narrow-kerf saw blades are used in the production of glued laminate flooring elements in plants where dry technology is applied. This means that boards or friezes are sawn into top layer lamellae in dry conditions (moisture content of about 10-12%) from expensive wood species, often exotic. The object of this research was stellite-tipped teeth of narrow kerf saw blades sharpened under industrial conditions. A NIKON ECLIPSE Ti-S microscope equipped with a NIKON DS-Fi2 recording camera was used to take pictures of teeth, which were analysed in a graphical software to measure the radii of the main cutting edges. The high-quality images obtained were used to determine the values of the rounding radii of the cutting edges. It was noted that the quality of edges regenerated in industrial conditions, some of which had chipping, was lower than that of brand new saw blades.

12.
Materials (Basel) ; 14(17)2021 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-34501141

RESUMEN

Changes associated to atomic layer deposition (ALD) of SiO2 from 3-aminopropyl triethoxysilane (APTES) and O3, on a nanoporous alumina structure, obtained by two-step electrochemical anodization in oxalic acid electrolyte (Ox sample) are analysed. A reduction of 16% in pore size for the Ox sample, used as support, was determined by SEM analysis after its coverage by a SiO2 layer (Ox+SiO2 sample), independently of APTES or O3 modification (Ox+SiO2/APTES and Ox+SiO2/APTES/O3 samples). Chemical surface modification was determined by X-ray photoelectron spectroscopy (XPS) technique during the different stages of the ALD process, and differences induced at the surface level on the Ox nanoporous alumina substrate seem to affect interfacial effects of both samples when they are in contact with an electrolyte solution according to electrochemical impedance spectroscopy (EIS) measurements, or their refraction index as determined by spectroscopic ellipsometry (SE) technique. However, no substantial differences in properties related to the nanoporous structure of anodic alumina (photoluminescent (PL) character or geometrical parameters) were observed between Ox+SiO2/APTES and Ox+SiO2/APTES/O3 samples.

13.
Materials (Basel) ; 14(4)2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33562630

RESUMEN

This article describes the comparative analysis of tests on bond strength of hot-dip galvanized and black steel to concrete with and without chlorides. The bond effect was evaluated with six research methods: strength, electrochemical (measurements of potential, EIS and LPR), optical, and 3D scanning. The tests were conducted within a long period of 18 months on 48 test elements reinforced with smooth rebars ϕ8 mm from steel grade S235JR+AR and ribbed rebars ϕ8 mm and ϕ16 mm from steel grade B500SP. The main strength tests on the reinforcement bond to concrete were used to compare forces pulling out galvanized and black steel rebars from concrete. This comparative analysis was performed after 28, 180, and 540 days from the preparation of the elements. The electrochemical tests were performed to evaluate corrosion of steel rebars in concrete, particularly in chloride contaminated concrete. The behaviour of concrete elements while pulling out the rebar was observed using the system of digital cameras during the optical tests. As regards 3D scanning of ribbed rebars ϕ8 mm and ϕ16 mm, this method allowed the detailed identification of their complex geometry in terms of determining the polarization area to evaluate the corrosion rate of reinforcement in concrete. The test results indicated that the presence of zinc coating on rebars had an impact on the parameters of anchorage. In the case of ribbed rebars of 16 mm in diameter, the maximum values of adhesive stress and bond stiffness were reduced over time when compared to black steel rebars. Moreover, it was noticed that the stiffness of rebar anchorage in chloride contaminated concrete was considerably higher than in concrete without chlorides.

14.
J Electron Mater ; 50(4): 2287-2294, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33551540

RESUMEN

An Al/p-Si/poly[2-methoxy-5-(2-ethylhexoxy)-p-phenylenevinylene] (MEH-PPV)/Ag organic heterojunction has been prepared using homemade ultrasonic spray pyrolysis (USP) equipment for deposition of the organic thin film and physical vapor deposition (PVD) for the metallic contacts. The organic layer produced on glass was analyzed by optical and morphological methods. The bandgap of the organic thin film was found to be ~ 2.03 eV with a thickness of around 140 nm, using ultraviolet-visible (UV-Vis) and scanning electron microscopy (SEM) characterization, respectively. The amorphous nature of the MEH-PPV polymer was confirmed by its x-ray diffraction pattern. To determine the electrical parameters, the heterojunction based on MEH-PPV was characterized by current-voltage (I-V) and capacitance-voltage (C-V) measurements in the dark at room temperature. The ideality factor and barrier height of the organic heterojunction were found to be 3.6 eV and 0.56 eV to 0.59 eV, respectively, with an average series resistance of 94.39 Ω, based on the I-V characteristics. The barrier height was also calculated based on the capacitance-voltage measurements, yielding slightly different results due to the applied frequencies of 10 kHz ( ϕ B = 0.50 ) and 1 MHz ( ϕ B = 0.74 ) , respectively.

15.
Materials (Basel) ; 13(23)2020 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-33256249

RESUMEN

The paper presents the finite element method model (FEM) which allows the forecasting of the evolution of damage in a concrete cover together with experimental verification of the model. The objective of the model is to define the corrosive volume strain tensor rate effected by corrosion, which comprises the accumulation of corrosion products in pore spaces as well as in micro-cracks which develop at the initial stage of cover degradation. The propagation of damage in the contact zone was captured by taking into account the function describing the degradation of the interface transition zone depending on the cover tightening time-critical time. The method of determining the critical time along with the method of taking into account the effective electrochemical equivalent of iron was also analyzed in this paper. The work presents the experimental verification of the model using an accelerated corrosion test of reinforcement in concrete and strain measurements with optical methods. The conducted tests demonstrate satisfactory compliance of the model with the test results.

16.
Materials (Basel) ; 13(21)2020 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-33126714

RESUMEN

A correct diagnosis in dental medicine is typically provided only after clinical and radiological evaluations. They are also required for treatment assessments. The aim of this study is to establish the boundaries from which a modern, although established, imaging technique, Optical Coherence Tomography (OCT), is more suitable than the common X-ray radiography to assess dental issues and treatments. The most common methods for daily-basis clinical imaging are utilized in this study for extracted teeth (but also for other dental samples and materials), i.e., panoramic, intraoral radiography, and three-dimensional (3D) cone beam computed tomography (CBCT). The advantages of using OCT as an imaging method in dentistry are discussed, with a focus on its superior image resolution. Drawbacks related to its limited penetration depth and Field-of-View (FOV) are pointed out. High-quality radiological investigations are performed, measurements are done, and data collected. The same teeth and samples are also imaged (mostly) with an in-house developed Swept Source (SS)-OCT system, Master-Slave enhanced. Some of the OCT investigations employed two other in-house developed OCT systems, Spectral Domain (SD) and Time Domain (TD). Dedicated toolbars from Romexis software (Planmeca, Helsinki, Finland) are used to perform measurements using both radiography and OCT. Clinical conclusions are drawn from the investigations. Upsides and downsides of the two medical imaging techniques are concluded for each type of considered diagnosis. For treatment assessments, it is concluded that OCT is more appropriate than radiography in all applications, except bone-related investigations and periodontitis that demand data from higher-penetration depths than possible with the current level of OCT technology.

17.
Sensors (Basel) ; 20(18)2020 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-32961673

RESUMEN

The aim of Lab-on-a-chip systems is the downscaling of analytical protocols into microfluidic devices, including optical measurements. In this context, the growing interest of the scientific community in opto-microfluidic devices has fueled the development of new materials. Recently, lithium niobate has been presented as a promising material for this scope, thanks to its remarkable optical and physicochemical properties. Here, we present a novel microfluidic device realized starting from a lithium niobate crystal, combining engraved microfluidic channels with integrated and self-aligned optical waveguides. Notably, the proposed microfabrication strategy does not compromise the optical coupling between the waveguides and the microchannel, allowing one to measure the transmitted light through the liquid flowing in the channel. In addition, the device shows a high versatility in terms of the optical properties of the light source, such as wavelength and polarization. Finally, the developed opto-microfluidic system is successfully validated as a probe for real-time pH monitoring of the liquid flowing inside the microchannel, showing a high integrability and fast response.

18.
ACS Sens ; 5(7): 2044-2051, 2020 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-32363857

RESUMEN

3D printing has emerged as a robust technique to fabricate reliable and reproducible microfluidic devices. However, a limitation of 3D-printed devices has been the low transparency even when printed in a "clear" material. There are currently no reports regarding direct optical measurements through a 3D-printed device. Here, we present for the first time that the printing orientation can affect the transparency of a 3D-printed object. With the optimal orientation, we printed a microfluidic detector that was sufficiently transparent (transmittance ≈ 80%) for optical quantitation. This finding is significant because it shows the feasibility to directly 3D-print optical components for analytical applications. In addition, we created a novel microfluidic dialysis device via 3D printing, which enabled higher flow rates (for sampling with high temporal resolution) and increased extraction efficiency than commercially available ones. By coupling the microfluidic detector and dialysis probe, we successfully measured the release kinetics of indole from biofilms in a continuous, automated, and near real-time fashion. Indole is an intercellular signaling molecule in biofilms, which may regulate antibiotic resistance. The release kinetics of this molecule had not been quantitated likely because of the lack of a suitable analytical tool. Our results fill this knowledge gap.


Asunto(s)
Dispositivos Laboratorio en un Chip , Microfluídica , Impresión Tridimensional
19.
Sensors (Basel) ; 20(9)2020 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-32403452

RESUMEN

The paper addresses the problem of fusing the measurements from multiple cameras in order to estimate the position of fiducial markers. The objectives are to increase the precision and to extend the working area of the system. The proposed fusion method employs an adaptive Kalman algorithm which is used for calibrating the setup of cameras as well as for estimating the pose of the marker. Special measures are taken in order to mitigate the effect of the measurement noise. The proposed method is further tested in different scenarios using a Monte Carlo simulation, whose qualitative precision results are determined and compared. The solution is designed for specific positioning and alignment tasks in physics experiments, but also, has a degree of generality that makes it suitable for a wider range of applications.

20.
Sensors (Basel) ; 19(12)2019 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-31242659

RESUMEN

Charge-coupled device (CCD) spectrometers are widely used as detectors in analytical laboratory instruments and as sensors for in situ optical measurements. However, as the applications become more complex, the physical and electronic limits of the CCD spectrometers may restrict their applicability. The errors due to dark currents, temperature variations, and blooming can be readily corrected. However, a correction for uncertainty of integration time and wavelength calibration is typically lacking in most devices, and detector non-linearity may distort the signal by up to 5% for some measurements. Here, we propose a simple correction method to compensate for non-linearity errors in optical measurements where compact CCD spectrometers are used. The results indicate that the error due to the non-linearity of a spectrometer can be reduced from several hundred counts to about 40 counts if the proposed correction function is applied.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA