Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 453
Filtrar
1.
EBioMedicine ; 108: 105355, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39293213

RESUMEN

BACKGROUND: Vascular dysfunction is closely associated with the progression of Alzheimer's disease (AD). A critical research gap exists that no studies have explored the in vivo temporal changes of cerebrovascular alterations with AD progression in mouse models, encompassing both structure and flow dynamics at micron-scale resolution across the early, middle, and late stages of the disease. METHODS: In this study, ultrasound localisation microscopy (ULM) was applied to image the cerebrovascular alterations of the transgenic female 5×FAD mouse model across different stages of disease progression: early (4 months), moderate (7 months), and late (12 months). Age-matched non-transgenic (non-Tg) littermates were used as controls. Immunohistology examinations were performed to evaluate the influence of disease progression on the ß-amyloid (Aß) load and microvascular alterations, including morphological changes and the blood-brain barrier (BBB) leakage. FINDINGS: Our findings revealed a significant decline in both vascular density and flow velocity in the retrosplenial cortex of 5×FAD mice at an early stage, which subsequently became more pronounced in the visual cortex and hippocampus as the disease progressed. Additionally, we observed a reduction in vascular length preceding diminished flow velocities in cortical penetrating arterioles during the early stages. The quantification of vascular metrics derived from ULM imaging showed significant correlations with those obtained from vascular histological images. Immunofluorescence staining identified early vascular abnormalities in the retrosplenial cortex. As the disease advanced, there was an exacerbation of Aß accumulation and BBB disruption in a regionally variable manner. The vascular changes observed through ULM imaging exhibited a negative correlation with amyloid load and were associated with the compromise of the BBB integrity. INTERPRETATION: Through high-resolution, in vivo imaging of cerebrovasculature, this study reveals significant spatiotemporal dysfunction in cerebrovascular dynamics accompanying disease progression in a mouse model of AD, enhancing our understanding of its pathophysiology. FUNDING: This study is supported by grants from National Key Research and Development Program of China (2020YFA0908800), National Natural Science Foundation of China (12074269, 82272014, 82327804, 62071310), Shenzhen Basic Science Research (20220808185138001, JCYJ20220818095612027, JCYJ20210324093006017), STI 2030-Major Projects (2021ZD0200500) and Guangdong Natural Science Foundation (2024A1515012591, 2024A1515011342).

2.
Bio Protoc ; 14(17): e5060, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39282233

RESUMEN

Current ischemic models strive to replicate ischemia-mediated injury. However, they face challenges such as inadequate reproducibility, difficulties in translating rodent findings to humans, and ethical, financial, and practical constraints that limit the accuracy of extensive research. This study introduces a novel approach to inducing persistent ischemia in 3-day-old chicken embryos using endothelin-1. The protocol targets the right vitelline arteries, validated with Doppler blood flow imaging and molecular biology experiments. This innovative approach facilitates the exploration of oxidative stress, inflammatory responses, cellular death, and potential drug screening suitability utilizing a 3-day-old chicken embryo. Key features • This model enables the evaluation and investigation of the pathology related to persistent ischemia • This model allows for the assessment of parameters like oxidative stress, inflammation, and cellular death • This model enables quantification of molecular changes at the nucleic acid and protein levels • This model allows for the efficient screening of drugs and their targets Graphical overview.

3.
J Ultrasound Med ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39240034

RESUMEN

OBJECTIVES: This study aimed to develop an ultrasound-guided high-intensity-focused ultrasound (USgHIFU) probe for arterial sonication and to evaluate vascular contraction. METHODS: The USgHIFU probe comprised two confocal spherical transducers for sonication and a US color Doppler flow imaging probe for guidance. A vessel-mimicking phantom was sonicated in two directions. In the vascular radial direction, an isolated rabbit aorta embedded in ex vivo pork liver was sonicated at different acoustic powers (245 and 519 W), flow rates (25, 30, and 50 mL/minute), and sonication energies (519, 980, and 1038 J). Changes in the postsonication vessels were evaluated using US imaging, microscopic observation, and histopathological analysis. RESULTS: Beam focusing along the vascular radial direction caused significant deformation of both tube walls (n = 4), whereas focusing along the axial direction only affected the contraction of the anterior wall (n = 4). The contraction index (Dc) of the vessel sonicated at 245 W and 980 J was 56.2 ± 9.7% (n = 12) with 25 mL/minute. The Dc of the vessel sonicated at 519 W and 1038 J was 56.5 ± 7.8% (n = 17). The Dc of the vessel sonicated at 519 J total energy was 18.3 ± 5.1% (n = 12). CONCLUSION: The developed USgHIFU probe induced greater vascular contractions by covering a larger area of the vessel wall in the radial direction. Sonication energy affects vascular contraction through temperature elevation of the vessel wall. When the acoustic power was high, an increase in acoustic power, even with comparable sonication energy, did not result in greater vessel contraction.

4.
Ultrasound Med Biol ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39244482

RESUMEN

OBJECTIVE: Local flow dynamics impact atherosclerosis yet are difficult to quantify with conventional ultrasound techniques. This study investigates the performance of ultrasound vector flow imaging (US-VFI) with and without ultrasound contrast agents in the healthy femoral bifurcation. METHODS: High-frame-rate ultrasound data with incremental acoustic outputs were acquired in the femoral bifurcations of 20 healthy subjects before (50V) and after contrast injection (2V, 5V and 10V). 2-D blood-velocity profiles were obtained through native blood speckle tracking (BST) and contrast tracking (echo particle image velocimetry [echoPIV]). As a reference, 4-D flow magnetic resonance imaging (4-D flow MRI) was acquired. Contrast-to-background ratio and vector correlation were used to assess the quality of the US-VFI acquisitions. Spatiotemporal velocity profiles were extracted, from which peak velocities (PSV) were compared between the modalities. Furthermore, root-mean-square error analysis was performed. RESULTS: US-VFI was successful in 99% of the cases and optimal VFI quality was established with the 10V echoPIV and BST settings. A good correspondence between 10V echoPIV and BST was found, with a mean PSV difference of -0.5 cm/s (limits of agreement: -14.1-13.2). Both US-VFI techniques compared well with 4-D flow MRI, with a mean PSV difference of 1.4 cm/s (-18.7-21.6) between 10V echoPIV and MRI, and 0.3 cm/s (-23.8-24.4) between BST and MRI. Similar complex flow patterns among all modalities were observed. CONCLUSION: 2-D blood-flow quantification of femoral bifurcation is feasible with echoPIV and BST. Both modalities showed good agreement compared to 4-D flow MRI. For the femoral tract the administration of contrast was not needed to increase the echogenicity of the blood for optimal image quality.

5.
Ultrasound Med Biol ; 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39122609

RESUMEN

OBJECTIVE: The proximal isovelocity surface area (PISA) method is a well-established approach for mitral regurgitation (MR) quantification. However, it exhibits high inter-observer variability and inaccuracies in cases of non-hemispherical flow convergence and non-holosystolic MR. To address this, we present EasyPISA, a framework for automated integrated PISA measurements taken directly from 2-D color-Doppler sequences. METHODS: We trained convolutional neural networks (UNet/Attention UNet) on 1171 images from 196 recordings (54 patients) to detect and segment flow convergence zones in 2-D color-Doppler images. Different preprocessing schemes and model architectures were compared. Flow convergence surface areas were estimated, accounting for non-hemispherical convergence, and regurgitant volume (RVol) was computed by integrating the flow rate over time. EasyPISA was retrospectively applied to 26 MR patient examinations, comparing results with reference PISA RVol measurements, severity grades, and cMRI RVol measurements for 13 patients. RESULTS: The UNet trained on duplex images achieved the best results (precision: 0.63, recall: 0.95, dice: 0.58, flow rate error: 10.4 ml/s). Mitigation of false-positive segmentation on the atrial side of the mitral valve was achieved through integration with a mitral valve segmentation network. The intraclass correlation coefficient was 0.83 between EasyPISA and PISA, and 0.66 between EasyPISA and cMRI. Relative standard deviations were 46% and 53%, respectively. Receiver operator characteristics demonstrated a mean area under the curve between 0.90 and 0.97 for EasyPISA RVol estimates and reference severity grades. CONCLUSION: EasyPISA demonstrates promising results for fully automated integrated PISA measurements in MR, offering potential benefits in workload reduction and mitigating inter-observer variability in MR assessment.

6.
Dig Endosc ; 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39129171

RESUMEN

OBJECTIVES: Detective flow imaging endoscopic ultrasonography (DFI-EUS) is a recent imaging modality developed for detecting fine vessels without the need for ultrasound contrast agents. The aim of the present study was to evaluate the utility of DFI-EUS for solid pancreatic lesions and to compare the diagnostic ability for pancreatic cancer (PC) between DFI-EUS, directional power Doppler (eFLOW) EUS, and contrast-enhanced harmonic (CH)-EUS. METHODS: Patients with a pancreatic lesion who underwent DFI-EUS, eFLOW-EUS, and CH-EUS between March 2019 and November 2023 were retrospectively enrolled. Final diagnoses were confirmed by pathologic examination of EUS-guided tissue acquisition and/or resected specimens. Lesions were categorized into the three patterns of poor, mild, and rich vascularity on DFI-EUS and eFLOW-EUS, and hypo-, iso-, and hypervascular on CH-EUS. PC was defined as a poor pattern on DFI-EUS and eFLOW-EUS, and a hypovascular pattern on CH-EUS. RESULTS: The final diagnoses of 90 examined tumors were PC (n = 57), inflammatory mass (n = 6), autoimmune pancreatitis (n = 13), neuroendocrine tumor (n = 9), and others (n = 5). The sensitivity, specificity, and accuracy for diagnosis of PC were 93%, 82%, and 88%, respectively, on DFI-EUS, 97%, 42%, and 77% on eFLOW-EUS, and 95%, 89%, and 92% on CH-EUS. The accuracy of DFI-EUS was significantly superior to eFLOW-EUS (P = 0.005), but no significant difference was found between DFI-EUS and CH-EUS. CONCLUSION: DFI-EUS is more sensitive for depicting vasculature than eFLOW-EUS, and has higher diagnostic sensitivity for PC. Evaluation of vascularity on DFI-EUS is useful for the differential diagnosis of pancreatic lesions without the need for intravenous contrast agent.

7.
Phys Med Biol ; 69(18)2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39168145

RESUMEN

Objective. Ultrafast ultrasound imaging using planar or diverging waves for transmission is a promising approach for efficient 3D imaging with matrix arrays. This technique has advantages for B-mode imaging and advanced techniques, such as 3D vector flow imaging (VFI). The computation load of the cross-beam technique is associated with the number of transmit anglesmand receive anglesn. The full velocity vector is obtained using the least square fashion. However, the beamforming is repeatedm × ntimes using a conventional time-domain delay-and-sum (DAS) beamformer. In the 3D case, the collection and processing of data from different beams increase the amount of data that must be processed, requiring more storage capacity and processing power. Furthermore, the large computation complexity of DAS is another major concern. These challenges translate into longer computational times, increased complexity in data processing, and difficulty in real-time applications.Approach. In response to this issue, this study proposes a novel Fourier domain beamformer for 3D plane wave imaging, which significantly increases the computational speed. Additionally, a selective compounding strategy is proposed for VFI, which reduces the beamforming process fromm × ntom(wheremandnrepresent the number of transmission and reception, respectively), effectively shortening the processing time. The underlying principle is to decompose the receive wavefront into a series of plane waves with different slant angles. Each slant angle can produce a sub-volume for coherent or selective compounding. This method does not rely on the assumption that the plane wave is perfect and the results show that our proposed beamformer is better than DAS in terms of resolution and image contrast. In the case of velocity estimation, for the Fourier-based method, only Tx angles are assigned in the beamformer and the selective compounding method produces the final image with a specialized Rx angle.Main results. Simulation studies andin vitroexperiments confirm the efficacy of this new method. The proposed beamformer shows improved resolution and contrast performance compared to the DAS beamformer for B-mode imaging, with a suppressed sidelobe level. Furthermore, the proposed technique outperforms the conventional DAS method, as evidenced by lower mean bias and standard deviation in velocity estimation for VFI. Notably, the computation time has been shortened by 40 times, thus promoting the real-time application of this technique. The efficacy of this new method is verified through simulation studies andin vitroexperiments and evaluated by mean bias and standard deviation. Thein vitroresults reveal a better velocity estimation: the mean bias is 2.3%, 3.4%, and 5.0% forvx,vy, andvz, respectively. The mean standard deviation is 1.8%, 1.7%, and 3.4%. With DAS, the evaluated mean bias is 9.8%, 4.6%, and 6.7% and the measured mean standard deviation is 7.5%, 2.5%, and 3.9%.Significance. In this work, we propose a novel Fourier-based method for both B-mode imaging and functional VFI. The new beamformer is shown to produce better image quality and improved velocity estimation. Moreover, the new VFI computation time is reduced by 40 times compared to conventional methods. This new method may pave a new way for real-time 3D VFI applications.


Asunto(s)
Análisis de Fourier , Imagenología Tridimensional , Imagenología Tridimensional/métodos , Ultrasonografía/métodos , Fantasmas de Imagen
8.
J Cardiovasc Magn Reson ; 26(2): 101078, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39098572

RESUMEN

BACKGROUND: Aortic diameter growth in type B aortic dissection (TBAD) is associated with progressive aortic dilation, resulting in increased mortality in patients with both de novo TBAD (dnTBAD) and residual dissection after type A dissection repair (rTAAD). Preemptive thoracic endovascular aortic repair may improve mortality in patients with TBAD, although it is unclear which patients may benefit most from early intervention. In vivo hemodynamic assessment using four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has been used to characterize TBAD patients with growing aortas. In this longitudinal study, we investigated whether changes over time in 4D flow-derived true and false lumen (TL and FL) hemodynamic parameters correlate with aortic growth rate, which is a marker of increased risk. METHODS: We retrospectively identified TBAD patients with baseline and follow-up 4D flow CMR at least 120 days apart. Patients with TBAD intervention before baseline or between scans were excluded. 4D flow CMR data analysis included segmentation of the TL and FL, followed by voxel-wise calculation of TL and FL total kinetic energy (KE), maximum velocity (MV), mean forward flow (FF), and mean reverse flow (RF). Changes over time (Δ) were calculated for all hemodynamic parameters. Maximal diameter in the descending aorta was measured from magnetic resonance angiogram images acquired at the time of 4D flow. Aortic growth rate was defined as the change in diameter divided by baseline diameter and standardized to scan interval. RESULTS: Thirty-two patients met inclusion criteria (age: 56.9 ± 14.1 years, female: 13, n = 19 rTAAD, n = 13 dnTBAD). Mean follow-up time was 538 days (range: 135-1689). Baseline aortic diameter did not correlate with growth rate. In the entire cohort, Δ FL MV (Spearman's rho [rho] = 0.37, p = 0.04) and Δ FL RF (rho = 0.45, p = 0.01) correlated with growth rate. In rTAAD only, Δ FL MV (rho = 0.48, p = 0.04) and Δ FL RF (rho = 0.51, p = 0.03) correlated with growth rate, while in dnTBAD only, Δ TL KE (rho = 0.63, p = 0.02) and Δ TL MV (rho = 0.69, p = 0.01) correlated with growth rate. CONCLUSION: 4D flow-derived longitudinal hemodynamic changes correlate with aortic growth rate in TBAD and may provide additional prognostic value for risk stratification. 4D flow MRI could be integrated into existing imaging protocols to allow for the identification of TBAD patients who would benefit from preemptive surgical or endovascular intervention.

9.
Int J Mol Sci ; 25(14)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39062800

RESUMEN

Transient ischemic attack (TIA) is an early warning sign of stroke and death, necessitating suitable animal models due to the associated clinical diagnostic challenges. In this study, we developed a TIA model using flexible spatially targeted photothrombosis combined with real-time blood flow imaging feedback. By modulating the excitation light using wavefront technology, we precisely created a square light spot (50 × 250 µm), targeted at the distal middle cerebral artery (dMCA). The use of laser speckle contrast imaging (LSCI) provided real-time feedback on the ischemia, while the excitation light was ceased upon reaching complete occlusion. Our results demonstrated that the photothrombus formed in the dMCA and spontaneously recanalized within 10 min (416.8 ± 96.4 s), with no sensorimotor deficits or infarction 24 h post-TIA. During the acute phase, ischemic spreading depression occurred in the ipsilateral dorsal cortex, leading to more severe ischemia and collateral circulation establishment synchronized with the onset of dMCA narrowing. Post-reperfusion, the thrombi were primarily in the sensorimotor and visual cortex, disappearing within 24 h. The blood flow changes in the dMCA were more indicative of cortical ischemic conditions than diameter changes. Our method successfully establishes a photochemical TIA model based on the dMCA, allowing for the dynamic observation and control of thrombus formation and recanalization and enabling real-time monitoring of the impacts on cerebral blood flow during the acute phase of TIA.


Asunto(s)
Circulación Cerebrovascular , Modelos Animales de Enfermedad , Ataque Isquémico Transitorio , Ataque Isquémico Transitorio/diagnóstico por imagen , Ataque Isquémico Transitorio/fisiopatología , Animales , Masculino , Trombosis/diagnóstico por imagen , Ratones , Imágenes de Contraste de Punto Láser/métodos , Arteria Cerebral Media/diagnóstico por imagen
10.
J Clin Ultrasound ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39011759

RESUMEN

We report a case of metastatic melanoma of the gallbladder diagnosed by contrast-enhanced ultrasound and systematically review the characteristics of transabdominal ultrasound, clinical manifestations, and treatment methods of gallbladder metastatic melanoma in order to provide reference ideas for the diagnosis and treatment of metastatic melanoma of gallbladder.

11.
Environ Sci Technol ; 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028920

RESUMEN

Manual microscopy is the gold standard for phytoplankton monitoring in diverse engineered and natural environments. However, it is both labor-intensive and requires specialized training for accuracy and consistency, and therefore difficult to implement on a routine basis without significant time investment. Automation can reduce this burden by simplifying the measurement to a single indicator (e.g., chlorophyll fluorescence) measurable by a probe, or by processing samples on an automated cytometer for more granular information. The cost of commercially available flow imaging cytometers, however, poses a steep financial barrier to adoption. To overcome these labor and cost barriers, we developed ARTiMiS: the Autonomous Real-Time Microbial 'Scope. The ARTiMiS is a low-cost flow imaging microscopy-based platform with onboard software capable of providing taxonomically resolved quantitation of phytoplankton communities in real-time. ARTiMiS leverages novel multimodal imaging and onboard machine learning-based data processing that is currently optimized for a curated and expandable database of industrially relevant microalgae. We demonstrate its operational limits, performance in identification of laboratory-cultivated microalgae, and potential for continuous monitoring of complex microalgal communities in full-scale industrial cultivation systems.

12.
Adv Sci (Weinh) ; 11(32): e2401173, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39031549

RESUMEN

Ultrasound velocimetry has been widely used for blood flow imaging. However, the flow measurements are constrained to resolve the in-plane 2D flow components when using a 1D transducer array. In this work, an ultrasound speckle decorrelation analysis-based velocimetry (3C-vUS) is proposed for 3D velocity components measurement using a 1D transducer array. The 3C-vUS theory is first derived and validated with numerical simulations and phantom experiments. The in vivo testing results show that 3C-vUS can accurately measure the blood flow 3D-velocity-components of the human carotid artery at arbitrary probe-to-vessel angles throughout the cardiac cycle. With such capability, the 3C-vUS will alleviate the requirement of operators and promote disease screening for blood flow-related disorders.


Asunto(s)
Arterias Carótidas , Imagenología Tridimensional , Fantasmas de Imagen , Reología , Transductores , Ultrasonografía , Humanos , Reología/métodos , Arterias Carótidas/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Imagenología Tridimensional/métodos , Ultrasonografía/métodos , Ultrasonografía/instrumentación
13.
Br J Radiol ; 97(1160): 1476-1482, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38885374

RESUMEN

OBJECTIVE: To explore the role of quantitative evaluation using carotid ultrasonography (US)-based high-frame-rate vector flow (V Flow) imaging in patients with low carotid stenosis. METHODS: This single-centre cross-sectional study consecutively recruited volunteers without carotid plaque and patients with low carotid stenosis from August 2022 to May 2023. Patients were divided into symptomatic and asymptomatic groups according to their head CT or MRI results within 8 weeks. All V Flow imaging examinations were performed using a Mindray Resona R9 US system. The wall shear stress (WSS) values, oscillatory shear index (OSI) values, and turbulence (Tur) indexes in the normal common carotid artery (CCA), normal carotid bifurcation (CB), and on the upstream and downstream surface of carotid plaque were measured. Pearson Chi-square test and Fisher exact test were used for counting data according to their type. For measurement data, independent sample t test and non-parametric rank sum test were used. RESULTS: The results proved that patients have higher WSS values and Tur indexes of CB than volunteers, and higher WSS values were detected on the surface of the plaques in symptomatic patients. What's more, the downstream side of the plaque was more vulnerable to plaque rupture than the upstream side due to more dynamic blood flow. CONCLUSION: Therefore, carotid US-based high-frame-rate V Flow imaging provides reliable mechanical biomarkers for assessing the haemodynamic change in patients with low stenosis. Our study may provide a new imaging tool for monitoring the progression of atherosclerosis and aiding the management of early atherosclerotic patients. ADVANCES IN KNOWLEDGE: Our study firstly investigated the difference of V Flow parameters on the surface of carotid plaques between symptomatic and asymptomatic patients with low carotid stenosis, which is expected to provide haemodynamic information and the mechanical basis for plaque rupture.


Asunto(s)
Estenosis Carotídea , Humanos , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/fisiopatología , Masculino , Femenino , Estudios Transversales , Persona de Mediana Edad , Anciano , Ultrasonografía/métodos , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiopatología , Ultrasonografía de las Arterias Carótidas
14.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38885741

RESUMEN

INTRODUCTION AND OBJECTIVES: Different degrees of testicular torsion result in varying degrees of testicular damage, which influences treatment options and outcomes. Therefore, establishing a testicular torsion model with different degrees is necessary for clinical diagnosis. MATERIALS AND METHODS: Rabbits were randomly divided into four groups and their spermatic cords were twisted at 0 °, 180 °, 360 °, and 720 °, respectively. Color Doppler flow imaging (CDFI) were performed to evaluate the blood supply in testicles. The twisted testicles were surgically removed at six hours post-operation and were evaluated by morphological observation and Hematoxylin and Eosin staining. RESULTS: CDFI signals were gradually decreased as the degree of testicular torsion increased, and scores of CDFI in the 360 ° and 720 ° groups were significantly decreased at postoperative six hours compared to pre-surgery. Compared to the sham, the testicle in the 180 ° group exhibited slight congestion, whereas the testicles in the 360 ° and 720 ° groups were dark red in color and had severe congestion and unrecognizable vessels. Hematoxylin and Eosin staining showed mild spermatogenic cell reduction and testicular interstitial hemorrhage in the 180 ° group. In the 360 ° and 720 ° groups, disordered seminiferous tubules, shed spermatogenic cells in tubules, inflammatory cell infiltration, and severe hemorrhage were found. In comparison with the sham, interstitial hemorrhage scores in the 360 ° and 720 ° groups were significantly higher, and scores of germinal epithelial cell thickness in the three testicular torsion groups were significantly decreased. CONCLUSIONS: Collectively, we successfully constructed a testicular torsion model with different degrees in rabbits.

15.
J Med Ultrason (2001) ; 51(3): 429-436, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38879837

RESUMEN

Gallbladder wall thickening is relatively common in clinical settings, and for appropriate diagnosis, the size, shape, internal structure, surface contour, and vascularity of the gallbladder wall must be evaluated. Morphological evaluation is the most important; however, some gallbladder lesions resemble gallbladder cancer in imaging studies, making differential diagnosis challenging. Vascular evaluation is indispensable for a precise diagnosis in these cases. In this review, we present the current status of vascular evaluation using US and diagnosis using vascular imaging for gallbladder lesions, including those presenting with wall thickening. To date, several ultrasound imaging techniques have been developed to assess vascularity, including Doppler imaging with high sensitivity, use of contrast agents, and microvascular imaging using a novel filter for Doppler imaging. Although conventional color Doppler imaging is rarely used for the diagnosis of gallbladder lesions, the efficacy of contrast-enhanced ultrasound in assessing the vascularity, enhancement pattern, or timing of enhancement/washout has been reported. Presence of multiple irregular microvessels has been speculated to indicate malignancy. However, few reports on microvessels have been published, and further studies are required for the precise diagnosis of gallbladder lesions with microvascular evaluation.


Asunto(s)
Medios de Contraste , Enfermedades de la Vesícula Biliar , Neoplasias de la Vesícula Biliar , Vesícula Biliar , Ultrasonografía , Humanos , Vesícula Biliar/diagnóstico por imagen , Vesícula Biliar/irrigación sanguínea , Enfermedades de la Vesícula Biliar/diagnóstico por imagen , Neoplasias de la Vesícula Biliar/diagnóstico por imagen , Neoplasias de la Vesícula Biliar/irrigación sanguínea , Ultrasonografía/métodos , Diagnóstico Diferencial , Ultrasonografía Doppler en Color/métodos
16.
Comput Biol Med ; 179: 108760, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38944903

RESUMEN

BACKGROUND: Extracting phenotype-representative flow patterns and their associated numerical metrics is a bottleneck in the clinical translation of advanced cardiac flow imaging modalities. We hypothesized that reduced-order models (ROMs) are a suitable strategy for deriving simple and interpretable clinical metrics of intraventricular flow suitable for further assessments. Combined with machine learning (ML) flow-based ROMs could provide new insight to help diagnose and risk-stratify patients. METHODS: We analyzed 2D color-Doppler echocardiograms of 81 non-ischemic dilated cardiomyopathy (DCM) patients, 51 hypertrophic cardiomyopathy (HCM) patients, and 77 normal volunteers (Control). We applied proper orthogonal decomposition (POD) to build patient-specific and cohort-specific ROMs of LV flow. Each ROM aggregates a low number of components representing a spatially dependent velocity map modulated along the cardiac cycle by a time-dependent coefficient. We tested three classifiers using deliberately simple ML analyses of these ROMs with varying supervision levels. In supervised models, hyperparameter grid search was used to derive the ROMs that maximize classification power. The classifiers were blinded to LV chamber geometry and function. We ran vector flow mapping on the color-Doppler sequences to help visualize flow patterns and interpret the ML results. RESULTS: POD-based ROMs stably represented each cohort through 10-fold cross-validation. The principal POD mode captured >80 % of the flow kinetic energy (KE) in all cohorts and represented the LV filling/emptying jets. Mode 2 represented the diastolic vortex and its KE contribution ranged from <1 % (HCM) to 13 % (DCM). Semi-unsupervised classification using patient-specific ROMs revealed that the KE ratio of these two principal modes, the vortex-to-jet (V2J) energy ratio, is a simple, interpretable metric that discriminates DCM, HCM, and Control patients. Receiver operating characteristic curves using V2J as classifier had areas under the curve of 0.81, 0.91, and 0.95 for distinguishing HCM vs. Control, DCM vs. Control, and DCM vs. HCM, respectively. CONCLUSIONS: Modal decomposition of cardiac flow can be used to create ROMs of normal and pathological flow patterns, uncovering simple interpretable flow metrics with power to discriminate disease states, and particularly suitable for further processing using ML.


Asunto(s)
Modelos Cardiovasculares , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Aprendizaje Automático , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/diagnóstico por imagen , Fenotipo , Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía Doppler en Color/métodos
17.
Innov Surg Sci ; 9(1): 25-35, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38826630

RESUMEN

Objectives: Intraoperative monitoring of blood flow (BF) remains vital to guiding surgical decisions. Here, we report the use of SurgeON™ Blood Flow Monitor (BFM), a prototype system that attaches to surgical microscopes and implements laser speckle contrast imaging (LSCI) to noninvasively obtain and present vascular BF information in real-time within the microscope's eyepiece. Methods: The ability of SurgeON BFM to monitor BF status during reversible vascular occlusion procedures was investigated in two large animal models: occlusion of saphenous veins in six NZW rabbit hindlimbs and clipping of middle cerebral artery (MCA) branches in four Dorset sheep brain hemispheres. SurgeON BFM acquired, presented, and stored LSCI-based blood flow velocity index (BFVi) data and performed indocyanine green video angiography (ICG-VA) for corroboration. Results: Stored BFVi data were analyzed for each phase: pre-occlusion (baseline), with the vessel occluded (occlusion), and after reversal of occlusion (re-perfusion). In saphenous veins, BFVi relative to baseline reduced to 5.2±3.7 % during occlusion and returned to 102.9±14.9 % during re-perfusion. Unlike ICG-VA, SurgeON BFM was able to monitor reduced BFVi and characterize re-perfusion robustly during five serial occlusion procedures conducted 2-5 min apart on the same vessel. Across four sheep MCA vessels, BFVi reduced to 18.6±7.7 % and returned to 120.1±27.8 % of baseline during occlusion and re-perfusion phases, respectively. Conclusions: SurgeON BFM can noninvasively monitor vascular occlusion status and provide intuitive visualization of BF information in real-time to an operating surgeon. This technology may find application in vascular, plastic, and neurovascular surgery.

18.
Magn Reson Med ; 92(3): 1248-1262, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38733066

RESUMEN

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications.


Asunto(s)
Algoritmos , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Artefactos , Simulación por Computador , Movimiento (Física) , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Corazón/diagnóstico por imagen
19.
J Appl Physiol (1985) ; 137(1): 32-41, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38813612

RESUMEN

Blood volume shifts during postural adjustment lead to irregular distension of the internal jugular vein (IJV). In microgravity, distension may contribute to flow stasis and thromboembolism, though the regional implications and associated risk remain unexplored. We characterized regional differences in IJV volume distension and flow complexity during progressive head-down tilt (HDT) (0°, -6°, -15°, -30°) using conventional ultrasound and vector flow imaging. We also evaluated low-pressure thigh cuffs (40 mmHg) as a fluid shifting countermeasure during -6° HDT. Total IJV volume expanded 139 ± 95% from supine position (4.6 ± 2.7 mL) to -30° HDT (10.3 ± 5.0 mL). Blood flow profiles had greater vector uniformity at the cranial IJV region (P < 0.01) and became more dispersed with increasing tilt (P < 0.01). Qualitatively, flow was more uniform throughout the IJV during its early flow cycle phase and more disorganized during late flow phase. This disorganized flow was accentuated closer to the vessel wall, near the caudal region, and during greater HDT. Low-pressure thigh cuffs during -6° HDT decreased IJV volume at the cranial region (-12 ± 15%; P < 0.01) but not the caudal region (P = 0.20), although flow uniformity was unchanged (both regions, P > 0.25). We describe a distensible IJV accommodating large volume shifts along its length. Prominent flow dispersion was primarily found at the caudal region, suggesting multidirectional blood flow. Thigh cuffs appear effective for decreasing IJV volume but effects on flow complexity are minor. Flow complexity along the vessel length is likely related to IJV distension during chronic volume shifting and may be a precipitating factor for flow stasis and future thromboembolism risk.NEW & NOTEWORTHY The internal jugular vein (IJV) facilitates cerebral outflow and is sensitive to volume shifts. Concerns about IJV expansion and fluid flow behavior in astronauts have surfaced following thromboembolism reports. Our study explored regional volume distension and blood flow complexity in the IJV during progressive volume shifting. We observed stepwise volume distension and increasing flow dispersion with head-down tilting across all regions. Flow dispersion may pose a risk of future thromboembolism during prolonged volume shifts.


Asunto(s)
Inclinación de Cabeza , Venas Yugulares , Humanos , Venas Yugulares/fisiología , Venas Yugulares/diagnóstico por imagen , Masculino , Inclinación de Cabeza/fisiología , Adulto , Femenino , Volumen Sanguíneo/fisiología , Adulto Joven , Flujo Sanguíneo Regional/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Ultrasonografía/métodos
20.
Clin Cosmet Investig Dermatol ; 17: 1183-1191, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38800356

RESUMEN

Background: Hematoporphyrin monomethyl ether (HMME) is a promising photosensitizer for photodynamic therapy (PDT) and has found wide application in the treatment of port-wine stains (PWS). Objective: This study aims to observe and analyze the clinical efficacy and safety of HMME-PDT in the treatment of PWS patients. It also aims to evaluate the usefulness of color Doppler flow imaging (CDFI), an ultrasound technique for detecting blood flow in skin lesions, in assessing clinical efficacy. Methods: Thirty-three patients with PWS underwent HMME-PDT at our dermatology outpatient clinic between January 2019 and March 2020. Data on patient demographics, lesion location, lesion type (pink, purple, nodular thickening), treatment frequency, and pre- and post-treatment images were collected and retrospectively analyzed. CDFI was performed on three patients. Results: All patients received intravenous HMME and underwent irradiation with 532 nm green LED light. Of these, 5 patients received 1 session of HMME-PDT, 14 received 2 sessions, 9 received 3 sessions and the remaining 5 patients received more than 3 sessions. Of the 33 patients, 9 were cured (27.27%), 10 showed improvement (30.30%), 11 experienced a reduction in symptoms (33.33%), and 3 showed no significant improvement (9.09%). Most patients reported local pain and oedema, and no systemic adverse effects were observed. Clinical efficacy correlated with lesion type and total number of treatment sessions. CDFI appears to be an excellent technique for assessing clinical efficacy. Conclusion: HMME-PDT is a safe and effective method for the treatment of PWS. CDFI examination appears to be a promising assessment tool. However, further validation with larger sample sizes is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA