Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Heliyon ; 10(12): e33210, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39021950

RESUMEN

Blasting vibration's effect on ground vibration is essentially an energy transfer and transformation process (Hongtao et al., 2010) [1]. In engineering, the blasting vibration duration is often used as an objective index to evaluate the blasting vibration hazard. Thus, this study on the factors influencing blasting vibration duration is essential. In this study, the blasting vibration duration prediction formula uses frequency and energy as independent parameters, which are analysed using a statistical t probability distribution. With the blasting vibration duration prediction formula, the delay time taken for the structure to reach the resonance frequency is obtained by calculating the dominant frequency of the structure. The results indicate that the frequency and energy of the blasting vibration signal are highly correlated with the duration of blasting vibration, and their introduction as independent parameters in the prediction formula can better improve the prediction accuracy. The dominant frequency should not be neglected in blasting vibration safety evaluations, and the use of blasting vibration duration prediction to calculate the dominant frequency can better avoid the resonance phenomenon in the structure.

2.
J Cardiovasc Electrophysiol ; 35(1): 182-197, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38031313

RESUMEN

INTRODUCTION: Multiple analysis techniques evaluate electrograms during atrial fibrillation (AF), but none have been established to guide catheter ablation. This study compares electrogram properties recorded from multiple right (RA) and left atrial (LA) sites. METHODS: Multisite LA/RA mapping (281 ± 176/239 ± 166 sites/patient) was performed in 42 patients (30 males, age 63 ± 9 years) undergoing first (n = 32) or redo-AF ablation (n = 10). All electrogram recordings were visually reviewed and artifactual signals were excluded leaving a total of 21 846 for analysis. Electrogram characteristics evaluated were cycle length (CL), amplitude, Shannon's entropy (ShEn), fractionation interval, dominant frequency, organizational index, and cycle length of most recurrent morphology (CLR ) from morphology recurrence plot analysis. RESULTS: Electrogram characteristics were correlated to each other. All pairwise comparisons were significant (p < .001) except for dominant frequency and CLR (p = .59), and amplitude and dominant frequency (p = .38). Only ShEn and fractionation interval demonstrated a strong negative correlation (r = -.94). All other pairwise comparisons were poor to moderately correlated. The relationships are highly conserved among patients, in the RA versus LA, and in those undergoing initial versus redo ablations. Antiarrhythmic drug therapy did not have a significant effect on electrogram characteristics, except minimum ShEn. Electrogram characteristics associated with ablation outcome were shorter minimum CLR , lower minimum ShEn, and longer mimimum CL. There was minimal overlap between the top 10 sites identified by one electrogram characteristic and the top 10 sites identified by the other 10 characteristics. CONCLUSION: Multiple techniques can be employed for electrogram analysis in AF. In this analysis of eight different electrogram characteristics, seven were poorly to moderately correlated and do not identify similar locations. Only some characteristics were predictive of ablation outcome. Further studies to consider electrogram properties, perhaps in combination, for categorizing and/or mapping AF are warranted.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Masculino , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
3.
Front Aging Neurosci ; 15: 1224264, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37818480

RESUMEN

Postoperative delirium (POD) is associated with adverse outcomes in elderly patients after surgery. Electroencephalography (EEG) can be used to develop a potential biomarker for degenerative cerebral dysfunctions, including mild cognitive impairment and dementia. This study aimed to explore the relationship between preoperative EEG and POD. We included 257 patients aged >70 years who underwent spinal surgery. We measured the median dominant frequency (MDF), which is a resting-state EEG biomarker involving intrinsic alpha oscillations that reflect an idle cortical state, from the prefrontal regions. Additionally, the mini-mental state examination and Montreal cognitive assessment (MoCA) were performed before surgery as well as 5 days after surgery. For long-term cognitive function follow up, the telephone interview for cognitive status™ (TICS) was performed 1 month and 1 year after surgery. Fifty-two (20.2%) patients were diagnosed with POD. A multivariable logistic regression analysis that included age, MoCA score, Charlson comorbidity index score, Mini Nutritional Assessment, and the MDF as variables revealed that the MDF had a significant odds ratio of 0.48 (95% confidence interval 0.27-0.85). Among the patients with POD, the postoperative neurocognitive disorders could last up to 1 year. Low MDF on preoperative EEG was associated with POD in elderly patients undergoing surgery. EEG could be a novel potential tool for identifying patients at a high risk of POD.

4.
Front Cardiovasc Med ; 10: 1145894, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37663412

RESUMEN

Background: Persistent Atrial Fibrillation (PersAF) electrogram-based ablation is complex, and appropriate identification of atrial substrate is critical. Little is known regarding the value of the Average Complex Interval (ACI) feature for PersAF ablation. Objective: Using the evolution of AF complexity by sequentially computing AF dominant frequency (DF) along the ablation procedure, we sought to evaluate the value of ACI for discriminating active drivers (AD) from bystander zones (BZ), for predicting AF termination during ablation, and for predicting AF recurrence during follow-up. Methods: We included PersAF patients undergoing radiofrequency catheter ablation by pulmonary vein isolation and ablation of atrial substrate identified by Spatiotemporal Dispersion or Complex Fractionated Atrial Electrograms (>70% of recording). Operators were blinded to ACI measurement which was sought for each documented atrial substrate area. AF DF was measured by Independent Component Analysis on 1-minute 12-lead ECGs at baseline and after ablation of each atrial zone. AD were differentiated from BZ either by a significant decrease in DF (>10%), or by AF termination. Arrhythmia recurrence was monitored during follow-up. Results: We analyzed 159 atrial areas (129 treated by radiofrequency during AF) in 29 patients. ACI was shorter in AD than BZ (76.4 ± 13.6 vs. 86.6 ± 20.3 ms; p = 0.0055), and mean ACI of all substrate zones was shorter in patients for whom radiofrequency failed to terminate AF [71.3 (67.5-77.8) vs. 82.4 (74.4-98.5) ms; p = 0.0126]. ACI predicted AD [AUC 0.728 (0.629-0.826)]. An ACI < 70 ms was specific for predicting AD (Sp 0.831, Se 0.526), whereas areas with an ACI > 100 ms had almost no chances of being active in AF maintenance. AF recurrence was associated with more ACI zones with identical shortest value [3.5 (3-4) vs. 1 (0-1) zones; p = 0.021]. In multivariate analysis, ACI < 70 ms predicted AD [OR = 4.02 (1.49-10.84), p = 0.006] and mean ACI > 75 ms predicted AF termination [OR = 9.94 (1.14-86.7), p = 0.038]. Conclusion: ACI helps in identifying AF drivers, and is correlated with AF termination and AF recurrence during follow-up. It can help in establishing an ablation plan, by prioritizing ablation from the shortest to the longest ACI zone.

5.
J Psycholinguist Res ; 52(6): 2499-2515, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37656324

RESUMEN

In Spanish, the plural form in plural dominant frequency pairs, like "diente/dientes" [tooth/teeth], occurs more frequently than the corresponding singular form. On the other hand, for the singular dominant frequency pairs such as "cometa/cometas" [kite/kites], the singular form is more common than the plural. The recognition of singular forms by adult readers is dependent on the dominance factor, while the identification of plural forms relies on the frequency of the stem. Given that age and reading experience may influence morphological processing of words, we investigate the representation of singulars and plurals in Spanish primary school children in Third Grade (8/9) and Sixth Grade (11/12) and adults through a lexical decision task. Though children's lexical decisions were twice as slow as adults, the pattern of morphological processing was consistent across ages: dominant plural forms resulted in decision times that were comparable to those of non-dominant singular forms, while recognition of singular-dominant forms was quicker than recognition of plural non-dominant forms. It appears that singulars are accessed and stored in the lexical memory as separate entities, while plurals depend on their morphological closer relatives, in this case, the singular forms.


Asunto(s)
Lectura , Reconocimiento en Psicología , Niño , Adulto , Humanos
6.
Circ J ; 87(7): 973-981, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37258220

RESUMEN

BACKGROUND: An epicardial connection (EC) between the right-sided pulmonary venous (RtPV) carina and right atrium (RA) may preclude PV isolation, but its electrophysiological role during atrial fibrillation (AF) remains unknown.Methods and Results: This prospective observational study included 98 consecutive patients undergoing catheter ablation for AF, subdivided into the EC group (n=17) and non-EC group (n=80) based on observation of RA posterior wall breakthrough during RtPV pacing. Mean left atrial (LA) dominant frequency (mean DFLA) was defined as the averaged DFs at the right and left PVs and LA appendage. The regional DF was higher in the EC group vs. the non-EC group except at the left PV antrum. The DF at the RA appendage (RAA) and mean DFLAwere equivocal (6.5±0.7 vs. 6.6±0.7 Hz) in the EC group, but the mean DFLAwas significantly higher than that at the RAA (5.8±0.6 vs. 6.1±0.5 Hz, P=0.001) in the non-EC group, suggesting an LA-to-RA DF gradient. A significant correlation of DF between the RtPV antrum and RAA was observed in the EC group (P<0.001, r=0.84) but not in the non-EC group. CONCLUSIONS: An electrophysiological link via interatrial ECs might attenuate the hierarchical nature of activation frequencies of AF, leading to advanced electrical remodeling of the atria.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Atrios Cardíacos , Venas Pulmonares/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Ablación por Catéter/métodos
7.
Foot (Edinb) ; 56: 102038, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37201241

RESUMEN

BACKGROUND: Diabetes mellitus (DM) is a clinical condition that affects gait performance and control in millions of individuals worldwide. Contrary to basic spatiotemporal parameters, gait-based spectral analysis may provide useful insights into gait neuromotor control. Hence, this study was set to investigate the spectral content of gait at the preferred speed in patients with DM. METHODS: Total 1117 individuals [658 DM and 649 healthy adults (HA)] performed a 10 m walk while wearing an inertial measurement unit over the fourth lumbar vertebra. Mann-Whitney-U test was used for between-group gait parameters comparisons. RESULTS: DM group had a slower step time (1.2%, p < 0.05) and gait speed (2.4%, p < 0.05) than HA. Additionally, DM individuals showed reduced dominant frequency (DM:0.24 Hz vs HA:0.25 Hz on average, p < 0.05). Increased antero-posterior and vertical dominant frequency width (DM:1.73 Hz vs HA:1.76 Hz on average, p < 0.05) and medio-lateral relative power spectral density at the dominant frequency (DM:6.19% vs HA:5.96%, p < 0.05). CONCLUSIONS: It was demonstrated for the first time that the gait spectral content, not only corroborates spatiotemporal characteristics, but also provides further insight into their neuromotor control deficits in diabetic patients. Ultimately, this type of analysis in the diabetic population can help guide the therapeutic interventions to prevent diabetic foot.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Adulto , Humanos , Marcha , Caminata , Velocidad al Caminar
8.
Cogn Neurodyn ; 17(2): 477-487, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37007193

RESUMEN

The external globus pallidus (GPe), a subcortical nucleus located in the indirect pathway of the basal ganglia, is widely considered to have tight associations with abnormal beta oscillations (13-30 Hz) observed in Parkinson's disease (PD). Despite that many mechanisms have been put forward to explain the emergence of these beta oscillations, however, it is still unclear the functional contributions of the GPe, especially, whether the GPe itself can generate beta oscillations. To investigate the role played by the GPe in producing beta oscillations, we employ a well described firing rate model of the GPe neural population. Through extensive simulations, we find that the transmission delay within the GPe-GPe pathway contributes significantly to inducing beta oscillations, and the impacts of the time constant and connection strength of the GPe-GPe pathway on generating beta oscillations are non-negligible. Moreover, the GPe firing patterns can be significantly modulated by the time constant and connection strength of the GPe-GPe pathway, as well as the transmission delay within the GPe-GPe pathway. Interestingly, both increasing and decreasing the transmission delay can push the GPe firing pattern from beta oscillations to other firing patterns, including oscillation and non-oscillation firing patterns. These findings suggest that if the transmission delays within the GPe are at least 9.8 ms, beta oscillations can be produced originally in the GPe neural population, which also may be the origin of PD-related beta oscillations and should be regarded as a promising target for treatments for PD.

9.
JACC Basic Transl Sci ; 8(1): 68-84, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36777167

RESUMEN

Traditional anatomically guided ablation and attempts to perform electrogram-guided atrial fibrillation (AF) ablation (CFAE, DF, and FIRM) have not been shown to be sufficient treatment for persistent AF. Using biatrial high-density electrophysiologic mapping in a canine rapid atrial pacing model of AF, we systematically investigated the relationship of electrogram morphology recurrence (EMR) (Rec% and CLR) with established AF electrogram parameters and tissue characteristics. Rec% correlates with stability of rotational activity and with the spatial distribution of parasympathetic nerve fibers. These results have indicated that EMR may therefore be a viable therapeutic target in persistent AF.

10.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36772669

RESUMEN

This article deals with the design of a methodology for vibration and noise measurement on a six-axis collaborative robotic arm. A vibration and noise measurement methodology is proposed for six robot positions. In each position, measurements were performed under defined equal boundary conditions. The boundary conditions were related to the velocities of the joints and the load on the robotic arm. The second part of the article is an evaluation of the initial experimental results. So far, only the acceleration of the sixth joint of the robotic arm-Wrist 3-has been measured. The aim of the measurements was to verify if the methodology presented can be used for vibration measurements. From the evaluation of the experimental measurements, it was determined that the given methodology can be used for vibration measurements. It was also found that the acceleration is transmitted in the axes other than the axis of motion of the robotic arm. In future experiments, the vibration at the other joints of the robotic arm will be measured and the noise of the robotic arm will be measured to confirm whether the proposed methodology is indeed functional.

11.
Sensors (Basel) ; 22(24)2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36560220

RESUMEN

Ground-penetrating radar (GPR) has been widely used in investigations of contaminated areas because of its sensitivity to variations associated with the nature of pore fluids. However, most of the studies were usually based on the visual interpretation of radargrams or on a time domain amplitude analysis. In this work, we propose a methodology that consists of analyzing the spectral content of the signal recorded in multi-frequency 3D GPR profiles. A remarkable advantage of this type of antenna is its step-frequency system, which provides a much wider emission spectrum than the one corresponding to conventional single-frequency antennas. From the data in the frequency domain, the dominant frequency and bandwidth were calculated as parameters whose variation could be related to the presence of light non-aqueous phase liquid (LNAPL) in the subsurface. By analyzing the variations of these two parameters simultaneously, we were able to delimit the contaminated zones in a case study, associating them with a significant shift of the frequency spectrum with respect to the average of the study area. Finally, as a validation method of the proposed methodology, the results of the frequency analysis were compared with resistivity data obtained with an electromagnetic conductivity meter, showing a very good correlation between the results.

12.
J Pers Med ; 12(10)2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-36294860

RESUMEN

Catheter ablation (CA) is a commonly used treatment for persistent atrial fibrillation (AF). Since its medium/long-term success rate remains limited, preoperative prediction of its outcome is gaining clinical interest to optimally select candidates for the procedure. Among predictors based on the surface electrocardiogram, the dominant frequency (DF) and harmonic exponential decay (γ) of the fibrillatory waves (f-waves) have reported promising but clinically insufficient results. Hence, the main goal of this work was to conduct a broader analysis of the f-wave harmonic spectral structure to improve CA outcome prediction through several entropy-based measures computed on different frequency bands. On a database of 151 persistent AF patients under radio-frequency CA and a follow-up of 9 months, the newly introduced parameters discriminated between patients who relapsed to AF and those who maintained SR at about 70%, which was statistically superior to the DF and approximately similar to γ. They also provided complementary information to γ through different combinations in multivariate models based on lineal discriminant analysis and report classification performance improvement of about 5%. These results suggest that the presence of larger harmonics and a proportionally smaller DF peak is associated with a decreased probability of AF recurrence after CA.

13.
Front Cardiovasc Med ; 9: 942998, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35928934

RESUMEN

Introduction: Atrial fibrillation (AF) is a heritable disease, and the paired-like homeodomain transcription factor 2 (PITX2) gene is highly associated with AF. We explored the differences in the circumferential pulmonary vein isolation (CPVI), which is the cornerstone procedure for AF catheter ablation, additional high dominant frequency (DF) site ablation, and antiarrhythmic drug (AAD) effects according to the patient genotype (wild-type and PITX2 +/- deficient) using computational modeling. Methods: We included 25 patients with AF (68% men, 59.8 ± 9.8 years of age, 32% paroxysmal AF) who underwent AF catheter ablation to develop a realistic computational AF model. The ion currents for baseline AF and the amiodarone, dronedarone, and flecainide AADs according to the patient genotype (wild type and PITX2 +/- deficient) were defined by relevant publications. We tested the virtual CPVI (V-CPVI) with and without DF ablation (±DFA) and three virtual AADs (V-AADs, amiodarone, dronedarone, and flecainide) and evaluated the AF defragmentation rates (AF termination or changes to regular atrial tachycardia (AT), DF, and maximal slope of the action potential duration restitution curves (Smax), which indicates the vulnerability of wave-breaks. Results: At the baseline AF, mean DF (p = 0.003), and Smax (p < 0.001) were significantly lower in PITX2 +/- deficient patients than wild-type patients. In the overall AF episodes, V-CPVI (±DFA) resulted in a higher AF defragmentation relative to V-AADs (65 vs. 42%, p < 0.001) without changing the DF or Smax. Although a PITX2 +/- deficiency did not affect the AF defragmentation rate after the V-CPVI (±DFA), V-AADs had a higher AF defragmentation rate (p = 0.014), lower DF (p < 0.001), and lower Smax (p = 0.001) in PITX2 +/- deficient AF than in wild-type patients. In the clinical setting, the PITX2 +/- genetic risk score did not affect the AF ablation rhythm outcome (Log-rank p = 0.273). Conclusion: Consistent with previous clinical studies, the V-CPVI had effective anti-AF effects regardless of the PITX2 genotype, whereas V-AADs exhibited more significant defragmentation or wave-dynamic change in the PITX2 +/- deficient patients.

14.
Alzheimers Res Ther ; 14(1): 109, 2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35932060

RESUMEN

INTRODUCTION: The differentiation of Lewy body dementia from other common dementia types clinically is difficult, with a considerable number of cases only being found post-mortem. Consequently, there is a clear need for inexpensive and accurate diagnostic approaches for clinical use. Electroencephalography (EEG) is one potential candidate due to its relatively low cost and non-invasive nature. Previous studies examining the use of EEG as a dementia diagnostic have focussed on the eyes closed (EC) resting state; however, eyes open (EO) EEG may also be a useful adjunct to quantitative analysis due to clinical availability. METHODS: We extracted spectral properties from EEG signals recorded under research study protocols (1024 Hz sampling rate, 10:5 EEG layout). The data stems from a total of 40 dementia patients with an average age of 74.42, 75.81 and 73.88 years for Alzheimer's disease (AD), dementia with Lewy bodies (DLB) and Parkinson's disease dementia (PDD), respectively, and 15 healthy controls (HC) with an average age of 76.93 years. We utilised k-nearest neighbour, support vector machine and logistic regression machine learning to differentiate between groups utilising spectral data from the delta, theta, high theta, alpha and beta EEG bands. RESULTS: We found that the combination of EC and EO resting state EEG data significantly increased inter-group classification accuracy compared to methods not using EO data. Secondly, we observed a distinct increase in the dominant frequency variance for HC between the EO and EC state, which was not observed within any dementia subgroup. For inter-group classification, we achieved a specificity of 0.87 and sensitivity of 0.92 for HC vs dementia classification and 0.75 specificity and 0.91 sensitivity for AD vs DLB classification, with a k-nearest neighbour machine learning model which outperformed other machine learning methods. CONCLUSIONS: The findings of our study indicate that the combination of both EC and EO quantitative EEG features improves overall classification accuracy when classifying dementia types in older age adults. In addition, we demonstrate that healthy controls display a definite change in dominant frequency variance between the EC and EO state. In future, a validation cohort should be utilised to further solidify these findings.


Asunto(s)
Enfermedad de Alzheimer , Demencia , Enfermedad por Cuerpos de Lewy , Enfermedad de Parkinson , Adulto , Anciano , Enfermedad de Alzheimer/diagnóstico , Demencia/diagnóstico , Electroencefalografía/métodos , Humanos , Enfermedad por Cuerpos de Lewy/diagnóstico
15.
Front Physiol ; 13: 946718, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35991173

RESUMEN

Purpose: Several studies have emphasised the significance of high dominant frequency (HDF) and rotors in the perpetuation of AF. However, the co-localisation relationship between both attributes is not completely understood yet. In this study, we aim to evaluate the spatial distributions of HDF regions and rotor sites within the left atrium (LA) pre and post HDF-guided ablation in PersAF. Methods: This study involved 10 PersAF patients undergoing catheter ablation targeting HDF regions in the LA. 2048-channels of atrial electrograms (AEG) were collected pre- and post-ablation using a non-contact array (EnSite, Abbott). The dominant frequency (DF, 4-10 Hz) areas with DF within 0.25 Hz of the maximum out of the 2048 points were defined as "high" DF (HDF). Rotors were defined as PSs that last more than 100 ms and at a similar location through subsequent phase frames over time. Results: The results indicated an extremely poor spatial correlation between the HDF regions and sites of the rotors in pre-versus post-ablation cases for the non-terminated (pre: CORR; 0.05 ± 0.17. vs. post: CORR; -0.030 ± 0.19, and with terminated patients (pre: CORR; -0.016 ± 0.03. post: CORR; -0.022 ± 0.04). Rotors associated with AF terminations had a long-lasting life-span post-ablation (non-terminated vs. terminated 120.7 ± 6.5 ms vs. 139.9 ± 39.8 ms), high core velocity (1.35 ± 1.3 mm/ms vs. 1.32 ± 0.9 mm/ms), and were less meandering (3.4 ± 3.04 mm vs. 1.5 ± 1.2 mm). Although the results suggest a poor spatial overlapping between rotors' sites and sites of AFCL changes in terminated and non-terminated patients, a higher correlation was determined in terminated patients (spatial overlapping percentage pre: 25 ± 4.2% vs. 17 ± 3.8% vs. post: 8 ± 4.2% vs. 3.7 ± 1.7% p < 0.05, respectively). Conclusion: Using non-contact AEG, it was noted that the correlation is poor between the spatial distribution of HDF regions and sites of rotors. Rotors were longer-lasting, faster and more stationary in patients with AF termination post-ablation. Rotors sites demonstrated poor spatial overlapping with sites of AFCL changes that lead to AF termination.

16.
Tohoku J Exp Med ; 258(3): 213-218, 2022 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-36002254

RESUMEN

The study aimed to evaluate the diagnostic and prognostic value of indexes detected by electrogastrography in Parkinson's disease patients. One hundred twenty early Parkinson's disease patients and 120 healthy controls were recruited, and underwent electrogastrography to detect dominant frequency (DF), instability coefficient of DF (ICDF), low frequency range (LFR), high frequency range (HFR), and normal frequency range (NFR). The receiver operating characteristic (ROC) curve was drawn for the diagnostic value analysis. The motor function was scored with the Unified Parkinson's Disease Rating Scale (UPDRS). Sniffin' Sticks test was used for the olfactory evaluation, and the TDI score consisting of odor threshold (T), odor discrimination (D) and odor identification (I) tests was calculated. The preprandial ICDF of Parkinson's disease patients was significantly higher than that of the control group, and decreased slowly during the late postprandial phase. The levels of LFR%, HFR% and NFR% in Parkinson's disease patients were higher than the control group during both the preprandial and late postprandial phase, and the changes of each index before and after meals were not obvious. Preprandial ICDF value and TDI score had the ability to distinguish Parkinson's disease patients with the AUC of 0.874 and 0.859 respectively. The ICDF detected by electrogastrography has high clinical value in the early diagnosis of Parkinson's disease, and the combination of ICDF and TDI can improve the diagnostic sensitivity and specificity of a single indicator. High ICDF levels during the preprandial phase are related to the poor prognosis of Parkinson's disease patients after treatment.


Asunto(s)
Trastornos del Olfato , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/diagnóstico , Olfato , Odorantes , Sensibilidad y Especificidad , Progresión de la Enfermedad
17.
Europace ; 24(11): 1788-1799, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35851611

RESUMEN

AIMS: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans. METHODS AND RESULTS: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes. Episodes of self-terminated PVT/VF lasted 8.6 s [95% confidence interval (CI): 8.1-9.1] and shock-terminated lasted 13.9 s (13.6-14.3) (P < 0.001). Recordings from patients with primarily electrical pathologies displayed higher DF and RI values than those from patients with primarily structural pathologies (P < 0.05) independently of ventricular function or antiarrhythmic drug therapy. Regardless of the underlying pathology, the average DF and RI intensities were lower in self-terminated than shock-terminated episodes [DF: 3.67 (4.04-4.58) vs. 4.32 (3.46-3.93) Hz, P < 0.001; RI: 0.53 (0.48-0.56) vs. 0.63 (0.60-0.65), P < 0.001]. In a multivariate analysis controlled by the type of pathology and clinical variables, regularity remained an independent predictor of self-termination [hazard ratio: 0.954 (0.928-0.980)]. Receiver operating characteristic (ROC) curve analysis of DF and RI intensities demonstrated increased predictability for self-termination in time with 95% CI above the 0.5 cut-off limit at about t = 8.6 s and t = 6.95 s, respectively. CONCLUSION: Consistent with the notion that fast organized sources maintain PVT/VF in humans, reduction of frequency and regularity correlates with early self-termination. Our findings might help generate ICD methods aiming to reduce inappropriate shock deliveries.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia
18.
Front Physiol ; 13: 826449, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35370796

RESUMEN

Purpose: Sites of highest dominant frequency (HDF) are implicated by many proposed mechanisms underlying persistent atrial fibrillation (persAF). We hypothesized that prospectively identifying and ablating dynamic left atrial HDF sites would favorably impact the electrophysiological substrate of persAF. We aim to assess the feasibility of prospectively identifying HDF sites by global simultaneous left atrial mapping. Methods: PersAF patients with no prior ablation history underwent global simultaneous left atrial non-contact mapping. 30 s of electrograms recorded during AF were exported into a bespoke MATLAB interface to identify HDF regions, which were then targeted for ablation, prior to pulmonary vein isolation. Following ablation of each region, change in AF cycle length (AFCL) was documented (≥ 10 ms considered significant). Baseline isopotential maps of ablated regions were retrospectively analyzed looking for rotors and focal activation or extinction events. Results: A total of 51 HDF regions were identified and ablated in 10 patients (median DF 5.8Hz, range 4.4-7.1Hz). An increase in AFCL of was seen in 20 of the 51 regions (39%), including AF termination in 4 patients. 5 out of 10 patients (including the 4 patients where AF termination occurred with HDF-guided ablation) were free from AF recurrence at 1 year. The proportion of HDF occurrences in an ablated region was not associated with change in AFCL (τ = 0.11, p = 0.24). Regions where AFCL decreased by 10 ms or more (i.e., AF disorganization) after ablation also showed lowest baseline spectral organization (p < 0.033 for any comparison). Considering all ablated regions, the average proportion of HDF events which were also HRI events was 8.0 ± 13%. Focal activations predominated (537/1253 events) in the ablated regions on isopotential maps, were modestly associated with the proportion of HDF occurrences represented by the ablated region (Kendall's τ = 0.40, p < 0.0001), and very strongly associated with focal extinction events (τ = 0.79, p < 0.0001). Rotors were rare (4/1253 events). Conclusion: Targeting dynamic HDF sites is feasible and can be efficacious, but lacks specificity in identifying relevant human persAF substrate. Spectral organization may have an adjunctive role in preventing unnecessary substrate ablation. Dynamic HDF sites are not associated with observable rotational activity on isopotential mapping, but epi-endocardial breakthroughs could be contributory.

19.
Front Physiol ; 13: 846620, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35370797

RESUMEN

Background: Although pulmonary vein isolation (PVI) gaps contribute to recurrence after atrial fibrillation (AF) catheter ablation, the mechanism is unclear. We used realistic computational human AF modeling to explore the AF wave-dynamic changes of PVI with gaps (PVI-gaps). Methods: We included 40 patients (80% male, 61.0 ± 9.8 years old, 92.5% persistent AF) who underwent AF catheter ablation to develop our realistic computational AF model. We compared the effects of a complete PVI (CPVI) and PVI-gap (2-mm × 4) on the AF wave-dynamics by evaluating the dominant frequency (DF), spatial change of DF, maximal slope of the action potential duration restitution curve (Smax), and AF defragmentation rate (termination or change to atrial tachycardia), and tested the effects of additional virtual interventions and flecainide on ongoing AF with PVI-gaps. Results: Compared with the baseline AF, CPVIs significantly reduced extra-PV DFs (p < 0.001), but PVI-gaps did not. COV-DFs were greater after CPVIs than PVI-gaps (p < 0.001). Neither CPVIs nor PVI-gaps changed the mean Smax. CPVIs resulted in higher AF defragmentation rates (80%) than PVI-gaps (12.5%, p < 0.001). In ongoing AF after PVI-gaps, the AF defragmentation rates after a wave-breaking gap ablation, extra-PV DF ablation, or flecainide were 60.0, 34.3, and 25.7%, respectively (p = 0.010). Conclusion: CPVIs effectively reduced the DF, increased its spatial heterogeneity in extra-PV areas, and offered better anti-AF effects than extra-PV DF ablation or additional flecainide in PVI-gap conditions.

20.
Front Cardiovasc Med ; 9: 838646, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35310982

RESUMEN

Introduction: Although the dominant frequency (DF) localizes the reentrant drivers and the maximal slope of the action potential duration (APD) restitution curve (Smax) reflects the tendency of the wave-break, their interaction has never been studied. We hypothesized that DF ablation has different effects on atrial fibrillation (AF) depending on Smax. Methods: We studied the DF and Smax in 25 realistic human persistent AF model samples (68% male, 60 ± 10 years old). Virtual AF was induced by ramp pacing measuring Smax, followed by spatiotemporal DF evaluation for 34 s. We assessed the DF ablation effect depending on Smax in both computational modeling and a previous clinical trial, CUVIA-AF (170 patients with persistent AF, 70.6% male, 60 ± 11 years old). Results: Mean DF had an inverse relationship with Smax regardless of AF acquisition timing (p < 0.001). Virtual DF ablations increased the defragmentation rate compared to pulmonary vein isolation (PVI) alone (p = 0.015), especially at Smax <1 (61.5 vs. 7.7%, p = 0.011). In post-DF ablation defragmentation episodes, DF was significantly higher (p = 0.002), and Smax was lower (p = 0.003) than in episodes without defragmentation. In the post-hoc analysis of CUVIA-AF2, we replicated the inverse relationship between Smax and DF (r = -0.47, p < 0.001), and we observed better rhythm outcomes of clinical DF ablations in addition to a PVI than of empirical PVI at Smax <1 [hazard ratio 0.45, 95% CI (0.22-0.89), p = 0.022; log-rank p = 0.021] but not at ≥ 1 (log-rank p = 0.177). Conclusion: We found an inverse relationship between DF and Smax and the outcome of DF ablation after PVI was superior at the condition with Smax <1 in both in-silico and clinical trials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA