Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Sci Rep ; 14(1): 21804, 2024 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294267

RESUMEN

This study aimed to determine the reliability and concurrent validity of a low-cost pressure mapping system (Smart mat) and reference standard pressure mapping (MatScan). Thirty healthy volunteers aged 29.57 ± 4.50 years who could sit still for at least one minute and had a hip width of less than 40 cm (36 ± 2.05 cm) were recruited. The participants sat on the Smart mat system and MatScan for 60 s per trial for 3 trials. The reliability of Smart mat using intraclass correlation coefficients (ICC) showed an excellent ICC of normalised total force (nTF) and normalised ischial width (nIW) in sitting (0.93, 0.98). The validity was assessed using Spearman correlation coefficients, which showed that nTF in sitting had a significantly strong correlation (r = 0.70**) and nIW in sitting had a significantly moderate correlation (r = 0.67**). This study's satisfactory results indicated that a low-cost pressure mapping system could be used for assessing forced distribution and ischial width during sitting.


Asunto(s)
Presión , Sedestación , Humanos , Adulto , Masculino , Femenino , Diseño de Equipo , Reproducibilidad de los Resultados , Voluntarios Sanos
2.
Am J Sports Med ; 52(11): 2775-2781, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39214078

RESUMEN

BACKGROUND: Data are lacking as to when a meniscal allograft transplant (MAT) may be biomechanically superior to a partially resected lateral meniscus. HYPOTHESIS: Lateral MAT using a bone bridge technique would restore load distribution and contact pressures in the tibiofemoral joint to levels superior to those of a partial lateral meniscectomy. STUDY DESIGN: Controlled laboratory study. METHODS: Eleven fresh-frozen human cadaveric knees were evaluated in 5 lateral meniscal testing conditions (native, one-third posterior horn meniscectomy, two-thirds posterior horn meniscectomy, total meniscectomy, MAT) at 3 flexion angles (0°, 30°, and 60°) under a 1600-N axial load. Pressure sensors were used to acquire contact pressure, contact area, and peak contact pressure within the tibiofemoral joint. RESULTS: Limited (one-third and two-thirds) partial lateral posterior horn meniscectomy showed no significant increase in mean and peak contact pressures as well as no significant decrease in contact area compared with the intact state. Total meniscectomy significantly increased mean contact pressure at 0° and 30° (P = .008 and P < .001, respectively), increased peak contact pressure at 30° (P = .04), and decreased mean contact area in all flexion angles compared with the native condition (P < .01). Lateral MAT significantly improved mean contact pressure compared with total meniscectomy at 0° and 30° (P = .002 and P = .003, respectively) and increased contact area at 30° and 60° (P = .003 and P = .009, respectively), although contact area was still significantly smaller (24.1%) after MAT relative to the native meniscus (P = 0.015). However, allograft transplant did not result in better tibiofemoral contact biomechanics compared with limited partial meniscectomy (P > .05). CONCLUSION: The peripheral portion of the lateral meniscus provided the most important contribution to the distribution of contact pressure across the tibiofemoral joint in the cadaveric model. Total meniscectomy significantly increased mean and peak contact pressure in the cadaveric model and decreased contact area. Lateral MAT restored contact biomechanics close to normal but was not superior to the partially meniscectomized status. CLINICAL RELEVANCE: Surgeons should attempt to preserve a peripheral rim of the posterior lateral meniscus. Meniscal allograft transplant appears to improve but not normalize mean contact pressure and contact area relative to total lateral meniscectomy.


Asunto(s)
Cadáver , Meniscectomía , Meniscos Tibiales , Humanos , Fenómenos Biomecánicos , Meniscos Tibiales/cirugía , Persona de Mediana Edad , Masculino , Soporte de Peso/fisiología , Aloinjertos , Anciano , Femenino , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Adulto
3.
Clin Orthop Surg ; 16(4): 570-577, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39092300

RESUMEN

Background: Increased load bearing across the patellofemoral and tibiofemoral articulations has been associated with total knee arthroplasty (TKA) complications. Therefore, the purpose of this study was to quantify the biomechanical characteristics of the patellofemoral and tibiofemoral joints and simulate varying weight-bearing demands after posterior cruciate ligament-retaining (CR) and posterior-stabilized (PS) TKAs. Methods: Eight fresh-frozen cadaveric knees (average age, 68.4 years; range, 40-86 years) were tested using a custom knee system with muscle-loading capabilities. The TKA knees were tested with a CR and then a PS TKA implant and were loaded at 6 different flexion angles from 15° to 90° with progressively increasing loads. The independent variables were the implant types (CR and PS TKA), progressively increased loading, and knee flexion angle (KFA). The dependent variables were the patellofemoral and tibiofemoral kinematics and contact characteristics. Results: The results showed that at higher KFAs, the position of the femur translated significantly more posterior in CR implants than in PS implants (36.6 ± 5.2 mm and 32.5 ± 5.7 mm, respectively). The patellofemoral contact force and contact area were significantly greater in PS than in CR implants at higher KFAs and loads (102.4 ± 12.5 N and 88.1 ± 10.9 N, respectively). Lastly, the tibiofemoral contact force was significantly greater in the CR than the PS implant at flexion angles of 45°, 60°, 75°, and 90° KFA, the average at these flexion angles for all loads tested being 246.1 ± 42.1 N and 192.8 ± 54.8 N for CR and PS implants, respectively. Conclusions: In this biomechanical study, CR TKAs showed less patellofemoral contact force, but more tibiofemoral contact force than PS TKAs. For higher loads across the joint and at increased flexion angles, there was significantly more posterior femur translation in the CR design with a preserved posterior cruciate ligament and therefore significantly less patellofemoral contact area and force than in the PS design. The different effects of loading on implants are an important consideration for physicians as patients with higher load demands should consider the significantly greater patellofemoral contact force and area of the PS over the CR design.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ligamento Cruzado Posterior , Soporte de Peso , Humanos , Anciano , Fenómenos Biomecánicos , Anciano de 80 o más Años , Soporte de Peso/fisiología , Persona de Mediana Edad , Ligamento Cruzado Posterior/cirugía , Adulto , Masculino , Femenino , Cadáver , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Articulación Patelofemoral/cirugía , Articulación Patelofemoral/fisiología , Rango del Movimiento Articular
4.
J Orthop Surg Res ; 19(1): 520, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39210457

RESUMEN

BACKGROUND: Commercially available osseointegrated devices for transfemoral amputees are limited in size and thus fail to meet the significant anatomical variability in the femoral medullary canal. This study aimed to develop a customized osseointegrated stem to better accommodate a variety of femoral anatomies in transfemoral amputees than off-the-shelf stems. Customization is expected to enhance cortical bone preservation and increase the stem-bone contact area, which are critical for the long-term stability and success of implants. METHODS: A customized stem (OsteoCustom) was designed based on the statistical shape variability of the medullary canal. The implantability of the OsteoCustom stem was tested via 70 computed tomography (CT) images of human femurs and compared to that of a commercial device (OFI-C) for two different resection levels. The evaluations included the volume of cortical bone removed and the percentage of stem-bone contact area for both resection levels. Statistical significance was analyzed using paired and unpaired t tests. RESULTS: The OsteoCustom stem could be virtually implanted in all 70 femurs, while the OFI-C was unsuitable in 19 cases due to insufficient cortical thickness after implantation, further emphasizing its adaptability to varying anatomical conditions. The OsteoCustom stem preserved a greater volume of cortical bone than did the OFI-C. In fact, 42% less bone was removed at the proximal resection level (3.15 cm³ vs. 5.42 cm³, p ≤ 0.0001), and 33% less at the distal resection level (2.25 cm³ vs. 3.39 cm³, p = 0.003). The stem-bone contact area was also greater for the OsteoCustom stem, particularly at the distal resection level, showing a 20% increase in contact area (52.3% vs. 32.2%, p = 0.002) compared to that of the OFI-C. CONCLUSIONS: The OsteoCustom stem performed better than the commercial stem by preserving more cortical bone and achieving a greater stem-bone contact area, especially at distal resection levels where the shape of the medullary canal exhibits more inter-subject variability. Optimal fit in the distal region is of paramount importance for ensuring the stability of osseointegrated implants. This study highlights the potential benefits of customized osseointegrated stems in accommodating a broader range of femoral anatomies, with enhanced fit in the medullary canal.


Asunto(s)
Amputados , Prótesis Anclada al Hueso , Fémur , Oseointegración , Diseño de Prótesis , Humanos , Fémur/cirugía , Fémur/diagnóstico por imagen , Masculino , Oseointegración/fisiología , Femenino , Persona de Mediana Edad , Adulto , Anciano , Miembros Artificiales , Tomografía Computarizada por Rayos X , Implantación de Prótesis/métodos , Adulto Joven
5.
BMC Musculoskelet Disord ; 25(1): 532, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38987711

RESUMEN

BACKGROUND: The Sauvé-Kapandji (S-K) method is a surgical procedure performed for chronic deformities of the distal radial ulnar joint (DRUJ). Changes to the joint contact surface from pre- to postoperatively under physiological in vivo conditions have not yet been determined for this useful treatment. The aim of the present study was therefore to compare the articular contact area of the wrist joint between before and after the S-K method for DRUJ disorders. METHODS: The SK method was performed for 15 patients with DRUJ osteoarthritis and ulnar impaction syndrome. We calculated the Mayo Wrist Score as the patient's clinical findings and created 3-dimensional bone models of cases in which the S-K method was performed and calculated the contact area and shift in the center of the contact area using customized software. RESULTS: The Mean modified Mayo Wrist Score improved significantly from 60.3 preoperatively to 80.3 postoperatively (P < 0.01). Scaphoid contact area to the radius increased significantly from 112.6 ± 37.0 mm2 preoperatively to 127.5 ± 27.8 mm2 postoperatively (P = 0.03). Lunate contact area to radius-ulna was 121.3 ± 43.3 mm2 preoperatively and 112.5 ± 37.6 mm2 postoperatively, but this decrease was not significant (P = 0.38). Contact area ratio of scaphoid to lunate increased significantly from 1.01 ± 0.4 preoperatively to 1.20 ± 0.3 postoperatively (P = 0.02). Postoperative translations of the center of the scaphoid and lunate contact areas were decomposed into ulnar and proximal directions. Ulnar and proximal translation distances of the scaphoid contact area were 0.8 ± 1.7 mm and 0.4 ± 0.6 mm, respectively, and those of the lunate contact area were 1.1 ± 1.7 mm and 0.4 ± 1.1 mm, respectively. This study revealed changes in wrist contact area and center of the contact area before and after the S-K method. CONCLUSION: These results may accurately indicate changes in wrist joint contact area from pre- to postoperatively using the S-K method for patients with DRUJ disorder. Evaluation of changes in contact area due to bone surface modeling of the wrist joint using 3DCT images may be useful in considering surgical methods.


Asunto(s)
Radio (Anatomía) , Cúbito , Articulación de la Muñeca , Humanos , Articulación de la Muñeca/cirugía , Articulación de la Muñeca/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Cúbito/cirugía , Cúbito/diagnóstico por imagen , Radio (Anatomía)/cirugía , Radio (Anatomía)/diagnóstico por imagen , Adulto , Osteoartritis/cirugía , Osteoartritis/diagnóstico por imagen , Anciano , Procedimientos Ortopédicos/métodos , Resultado del Tratamiento
6.
Clin Oral Investig ; 28(7): 374, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38878070

RESUMEN

OBJECTIVE: We aimed to evaluate changes in the zygomatic pillar during orthodontic treatment involving premolar extraction, analyze the effects of maxillary first molar movement on zygomatic pillar remodeling, and examine occlusal characteristics and stress distribution after remodeling. METHODS: Twenty-five patients who underwent premolar extraction were included in the study. The zygomatic pillar measurement range was defined, and cross-sectional areas, surface landmark coordinates, alveolar and cortical bone thicknesses, and density changes were assessed using Mimics software based on the cone-beam computed tomography scans taken before (T0) and after the treatment (T1). Multiple linear regression analysis was performed to determine the correlation between changes in the zygomatic pillar and maxillary first molar three-dimensional (3D) movement and rotation. Additionally, the correlation between pillar remodeling and occlusal characteristics was analyzed by Teetester. Pre- and post-reconstruction 3D finite element models were constructed and loaded with an average occlusal force of two periods. RESULTS: The morphological and structural remodeling of the zygomatic pillar after orthodontic treatment involving premolar extraction showed a decreased cross-sectional area of the lower segment of the zygomatic pillar. The zygomatic process point moved inward and backward, whereas the zygomatico-maxillary suture point moved backward. The thicknesses of the zygomatic pillar alveolar and cortical bones were thinner, and reduced alveolar bone density was observed. Simultaneously, the movement and angle change of the maxillary first molar could predict zygomatic pillar reconstruction to a certain extent. With decreasing the total occlusal force and the occlusal force of the first molar, occlusal force distribution was more uniform. With zygomatic pillar remodeling, occlusal stress distribution in the zygomatic alveolar ridge decreased, and occlusal stress was concentrated at the junction of the vertical and horizontal parts of the zygomatic bone and the posterior part of the zygomatic arch. CONCLUSIONS: Orthodontic treatment involving premolar extraction led to zygomatic pillar remodeling, making it more fragile than before and reducing the occlusal force of the maxillary first molar and the entire dentition with stress concentrated in weak areas. CLINICAL RELEVANCE: No other study has focused on the effects of orthodontics on pillar structures. The present study indicates that the mesial movement of the maxillary first molar weakened the zygomatic pillar and reduced occlusal function, thereby providing insights for inserting anchorage screws and facial esthetics.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Análisis de Elementos Finitos , Diente Molar , Técnicas de Movimiento Dental , Cigoma , Humanos , Técnicas de Movimiento Dental/métodos , Femenino , Masculino , Diente Premolar , Maxilar , Extracción Dental , Imagenología Tridimensional , Adolescente , Remodelación Ósea/fisiología , Análisis del Estrés Dental , Adulto , Adulto Joven
7.
J Oral Rehabil ; 51(9): 1675-1683, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38926933

RESUMEN

BACKGROUND: The T-scan system has been used previously to analyse occlusion, but the quantitative analysis of occlusal contact by T-Scan system has yet to be reported. OBJECTIVES: To evaluate the reliability and validity of T-Scan system for quantitatively measuring occlusal contact area and occlusal contact number. METHODS: Twenty-two individuals with normal occlusion, 11 men and 11 women, were recruited for the study. Two occlusal analysis methods, including silicone transmission analysis method (STA) and T-Scan occlusion analysis method (TSO), were used to make quantitative analysis to measure occlusal contact area (OCA) and occlusal contact number (OCN). A test-retest check was performed with an interval of 2 weeks. The values of intraclass correlation coefficients (ICC) between test-retest of each method were calculated for reliability evaluation. Pearson correlations analysis, paired t-tests, regression analysis and Bland-Altman analysis were performed for validity evaluation. RESULTS: The ICC values of STA were greater than those of TSO for OCA while for OCN, ICC values of TSO were greater than STA. The higher OCA and OCN values were found in TSO compared with STA. Pearson's correlation coefficient indicated strong relations between TSO and STA (0.730-0.812) for OCA, while good relations between then (0.569-0.583) for OCN. Paired t-test showed a significant difference between the OCA and OCN values between TSO and STA. Bland-Altman analysis showed good agreement between OCA and OCN values of TSO and STA both in men and women. Regression analysis identified a linear correlation between OCA values obtained from these two methods. CONCLUSIONS: T-Scan method showed strong reliability for measuring OCA and OCN quantitatively. Strong correlations were found between OCA values from TSO and STA method, but the validity of TSO for measuring OCN needs to be promoted. CLINICAL SIGNIFICANCE: T-Scan system demonstrates good potential in quantitative analysis of occlusion, which will expand its clinical application.


Asunto(s)
Oclusión Dental , Humanos , Femenino , Masculino , Reproducibilidad de los Resultados , Adulto , Adulto Joven , Registro de la Relación Maxilomandibular/métodos , Registro de la Relación Maxilomandibular/instrumentación
8.
Orthod Craniofac Res ; 2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38881173

RESUMEN

AIM: This in vitro study aimed to evaluate and compare the bone-miniscrew contact surface area (BMC) and the cortical bone microcracks (CM) resulting from manual (hand-driven) and automated (motor-driven) orthodontic miniscrew (OM) insertion methods. METHODS: Thirty-three OM were inserted in the femurs of nine New Zealand rabbits using manual (n = 16) and automated (n = 17) insertions. After euthanizing the rabbits, bone blocks, each including one OM, were sawed. Micro-CT scanning was performed, and data analysis included reconstruction, binarization and quantification of morphometric parameters of BMC and the number and length of CM. Means and standard deviations for complete BMC, complete BMC proportion, cortical BMC, cortical BMC proportion, and length and number of CM were calculated. Mixed model analysis was used to adjust for more than one sample/CM per animal. A paired t-test was used to compare the number of CM between the two groups. RESULTS: Compared to the automated insertion, manually inserted miniscrews had significantly lower complete BMC (7.54 ± 1.80 mm2 vs. 11.99 ± 3.64 mm2), cortical BMC (5.91 ± 1.48 mm2 vs. 8.48 ± 1.90 mm2) and cortical BMC proportion (79.44 ± 5.84% vs. 87.94 ± 3.66%). However, it was not statistically significant in complete BMC proportion (p = .052). The automated insertion also resulted in a significantly lower mean number of CM than the manual method (p = .012). However, the length of the cracks was shorter in the manual group but with no significant difference (p = 0.256). CONCLUSION: Motor-driven OM insertion results in superior BMC and reduction in the number of CM, which may lead to better miniscrew stability.

9.
Materials (Basel) ; 17(7)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38612054

RESUMEN

The application of low-density polyethylene (LDPE) has been confined to packaging applications due to its inadequate mechanical and tribological characteristics. We propose enhancing LDPE by integrating hard carbon spheres (CSs) to improve its strength, frictional characteristics, and wear resistance. LDPE/CS composites were created by blending LDPE with varying CS amounts (0.5-8 wt.%). Analysis using scanning electron microscopy and Raman spectroscopy confirmed CS presence in the LDPE matrix, with X-ray diffraction showing no microstructural changes post-blending. Thermal characterization exhibited notable improvements in thermal stability (~4%) and crystallinity (~7%). Mechanical properties such as hardness and Young's modulus were improved by up to 4% and 24%, respectively. Tribological studies on different composite samples with varying surface roughness under various load and speed conditions revealed the critical role of surface roughness in reducing friction by decreasing real contact area and adhesive interactions between asperities. Increased load and speed amplified shear stress on asperities, possibly leading to deformation and failure. Notably, integrating CSs into LDPE, starting at 1 wt.%, effectively reduced friction and wear. The composite with the highest loading (8 wt.%) displayed the most significant tribological enhancement, achieving a remarkable 75% friction reduction and a substantial 78% wear reduction.

10.
J Esthet Restor Dent ; 36(9): 1258-1266, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38634200

RESUMEN

OBJECTIVE: This study aimed to present three indicators that represent the proximal contact area gap change under intercuspal occlusion and to see if and how these indicators influence food impaction with tight proximal contact. MATERIALS AND METHODS: Ninety volunteers were recruited for bite force measurement and intraoral scanning. Three-dimensional surface data and buccal bite data were obtained for 60 impacted and 60 non-impacted teeth. The scanning data were imported into the Geomagic Studio 2013 to measure three indicators, which included the gap change maximum (Δdm, µm), the buccolingual position of Δdm (P), and the gap expanded buccolingual range (S, mm). The difference between two groups of three indicators and their relationship with food impaction with tight proximal contact were analyzed by the t test, the Pearson chi-squared test, the nonparametric Mann-Whitney U test, and the binary logistic regression analysis (a = 0.05). RESULTS: All indicators (Δdm, P, and S) were statistically different (p < 0.001, p = 0.002, and p < 0.001) in the impacted and non-impacted groups. Food impaction with tight proximal contact was affected by Δdm and S (p < 0.001, p = 0.039), but not by P (p = 0.409). CONCLUSION: The excessive increase of the gap change maximum and the gap expanded buccolingual range under bite force promoted the occurrence of food impaction with tight proximal contact. CLINICAL SIGNIFICANCE: The use of intraoral scanning to measure the characteristics of the proximal contact area gap change under bite force may help to deepen our understanding of the pathogenesis of food impaction with tight proximal contact. Importantly it can provide a reference basis for individualizing and quantifying occlusal adjustment treatment.


Asunto(s)
Alimentos , Humanos , Masculino , Adulto , Femenino , Oclusión Dental , Fuerza de la Mordida , Imagenología Tridimensional/métodos , Adulto Joven
11.
Materials (Basel) ; 17(5)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38473665

RESUMEN

We developed a soft contact probe capable of making electrical contact with a specimen without causing damage. This probe is now commercially available. However, the contact area with the probe changes according to the pressure applied during electric contact, potentially affecting electric measurements when current density or electric field strength is critical. To address this, we developed methods to control the area of electric contact. This article reports on these methods, as well as variations in probe size, pressure for electric contact, probe materials, and attachment to commercial probers.

12.
Cureus ; 16(2): e53803, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465079

RESUMEN

BACKGROUND: The biomechanical effect of distal tibial oblique osteotomy (DTOO) on osteoarthritic ankles has not been investigated. Using finite element (FE) models, we aimed to elucidate the effect of DTOO on the ankle contact pressure (CP) distribution. METHODS: This study included two patients with ankle osteoarthritis who underwent DTOO and one asymptomatic control. Patient-specific FE models were reconstructed by matching standing radiographs with supine computed tomography scans. The joint contact area (CA) and maximum CP on the articular surface of the talus were calculated before and after DTOO and compared with those of the control. RESULTS: In the control, the CA was 584 mm2 and the maximum CP was 2.6 MPa. In case 1, the CA increased by 125% from 166 mm2 preoperatively to 375 mm2 postoperatively, accompanied by a 36% decrease in the maximum CP from 9.8 MPa to 6.3 MPa. Similarly, in case 2, the CA increased by 46% from 301 mm2 to 439 mm2, accompanied by a 27% decrease in the maximum CP from 6.7 MPa to 4.9 MPa. CONCLUSIONS: This study suggests DTOO improves the biomechanics of the ankle, but not sufficiently compared to the control. This analytical approach may enhance understanding of ankle pathophysiology and assist in the design of the ideal corrective osteotomy.

13.
Polymers (Basel) ; 16(3)2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-38337228

RESUMEN

In the field of bone tissue engineering, which is being developed for the ideal restoration of bone defects, researchers are exploring the improvement of the bone regeneration efficacy of scaffolds through various approaches involving osteoconductive, osteoinductive, and angiogenic factors. In the current trend of research, there is also a suggestion that the topological factors of recent scaffolds may influence the attachment, migration, proliferation, and differentiation of bone cells. Building upon experimental confirmation of the effect of scaffold conformity with the defect site on enhanced bone regeneration in previous studies, we conducted this research to experimentally investigate the relationship between contact area with the defect site and bone regeneration efficacy. The results demonstrated that as the contact area of the scaffold increased, not only did the resistance to bone tissue growth increase, more significant bone regeneration also occurred, as evidenced through histological analysis and micro-CT analysis. This research confirms that the contact area between the scaffold and the defect site is a critical variable affecting bone regeneration efficacy, emphasizing its importance when designing customized scaffolds. This finding holds promising implications for future studies and applications in the field.

14.
Clin Oral Investig ; 28(3): 182, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38424318

RESUMEN

OBJECTIVES: The present study aims to assess the impact of bilateral and high oblique sagittal split osteotomy (BSSO/HSSO), as well as displacement distances and directions on the expected and achievable bone contact area (BCA) and changes in the intercondylar distance (ICD). The primary question addressed is whether mandibular splitting through BSSO results in a greater BCA and/or ICD when compared to splitting through HSSO. MATERIALS AND METHODS: Totally 80 mandibular displacements were performed on 20 fresh cadavers, for each subject, four splints were produces to facilitate mandibular advancement as well as setbacks of 4 and 8 mm. Pre- and postoperative CBCT scans were performed to plan the surgical procedures and to analyze the expected and achieved BCA and ICD. RESULTS: Regarding the maximum mandibular displacement, the expected BCA for HSSO/BSSO were 352.58 ± 96.55mm2 and 1164.00 ± 295.50mm2, respectively, after advancement and 349.11 ± 98.42mm2 and 1344.70 ± 287.23mm2, respectively, after setback. The achieved BCA for HSSO/BSSO were 229.37 ± 75.90mm2 and 391.38 ± 189.01mm2, respectively, after advancement and 278.03 ± 97.65mm2 and 413.52 ± 169.52 mm2, respectively after setback. The expected ICD for HSSO/BSSO were 4.51 ± 0.73 mm and 3.25 ± 1.17 mm after advancement and - 5.76 ± 1.07 mm and - 4.28 ± 1.58 mm after setback. The achieved ICD for HSSO/BSSO were 2.07 ± 2.9 mm and 1.7 ± 0.60 mm after advancement and - 2.57 ± 2.78 mm and - 1.28 ± 0.84 mm after setback. Significant differences between the BCA after HSSO and BSSO were at each displacement (p < 0.001), except for the achieved BCA after 8-mm setback and advancement (p ≥ 0.266). No significant differences were observed regarding ICD, except for the expected ICD after 8-mm setback and advancement (p ≤ 0.037). CONCLUSIONS: Compared to the virtual planning, the predictability regarding BCA and ICD was limited. ICD showed smaller clinical changes, BCA decreased significantly in the BSSO group. CLINICAL RELEVANCE: BCA and ICD might have been less important in choosing the suitable split technique. in orthognathic surgery.


Asunto(s)
Maloclusión , Avance Mandibular , Cirugía Ortognática , Sitoesteroles , Humanos , Osteotomía Sagital de Rama Mandibular/métodos , Mandíbula/cirugía
15.
Biomimetics (Basel) ; 9(1)2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38248626

RESUMEN

The quasi-static regime of friction between a rigid steel indenter and a soft elastomer with high adhesion is studied experimentally. An analysis of the formally calculated dependencies of a friction coefficient on an external load (normal force) shows that the friction coefficient monotonically decreases with an increase in the load, following a power law relationship. Over the entire range of contact loads, a friction mode is realized in which constant shear stresses are maintained in the tangential contact, which corresponds to the "adhesive" friction mode. In this mode, Amonton's law is inapplicable, and the friction coefficient loses its original meaning. Some classical works, which show the existence of a transition between "adhesive" and "normal" friction, were analyzed. It is shown that, in fact, there is no such transition. A computer simulation of the indentation process was carried out within the framework of the boundary element method, which confirmed the experimental results.

16.
Foot Ankle Surg ; 30(2): 135-144, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37919180

RESUMEN

INTRODUCTION: Ankle fractures account for approximately 10 % of all fractures. Approximately 5-68 % of patients with ankle fractures may suffer from malunion. Besides, suboptimal reduction of fracture fragments can affect the biomechanics of the ankle joint, ultimately leading to damage to the ankle joint. However, there are certain controversies over the conclusion of previous cadaveric studies. METHODS: In this study, a three-dimensional model of the ankle joint was established based on CT image data. In addition, the effects of backward offset (1-2 mm) and outward offset (0.5-1 mm) of the fracture fragment on the contact area, contact pressure, and ligament force of the ankle joint were investigated via the finite element method. Moreover, lateral malleolus fracture malunion in five ankle positions (neutral, 10° dorsiflexion, 10° plantarflexion, 20° dorsiflexion, and 20° plantarflexion) was investigated. RESULTS: This model predicted an overall increased contact area in the ankle joint in patients with lateral malleolus fracture malunion compared with the normal ankle joint. The results demonstrated that the outward offset had a more significant effect than the backward one. The larger the dorsiflexion-plantarflexion angle, the more pronounced the effect of malunion. Further, an outward offset can cause the fibula to lose its function. CONCLUSION: Post-traumatic osteoarthritis occurs under the action of unaccustomed cartilage forces due to altered tibial talar joint contact patterns, rather than increased contact pressure reported in previous studies. Malunion leads to an increase or decrease in force on the affected ligament, while the cause of malunion can be envisioned based on a decrease in the force on the ligaments.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Humanos , Fracturas de Tobillo/cirugía , Articulación del Tobillo/cirugía , Tobillo , Fenómenos Biomecánicos , Traumatismos del Tobillo/cirugía
17.
Materials (Basel) ; 16(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38068192

RESUMEN

The contact state of a seamless internal threaded copper tube and an aluminium foil fin not only affects the heat transfer efficiency of a tube-fin heat exchanger but also seriously affects its service life. In this study, hydraulic expansion technology was used to connect the copper tube with an internal thread with a 7 mm diameter to the fin of the heat exchanger. The influence of the expansion pressure and pressure holding time on the contact state was analysed through experiments and finite element simulation, and the variation law of the two on the contact state was obtained. The contact state was characterised by the contact gap and contact area. In order to obtain the specific contact area value, a new method of measuring the contact area was developed to reveal the variation in contact area between the copper tube and the fin after expansion. The results show that the contact gap decreases with an increase in expansion pressure, while the pressure holding time remains the same. The contact area increases with an increase in expansion pressure, and the rate of increase slows. When the expansion pressure is 18 MPa, the average contact gap is approximately 0.018 mm. When the expansion pressure reaches 16 MPa, the contact area ratio is 91.0%. When the expansion pressure increases to 18 MPa, the contact area ratio only increases by approximately 0.6%. Compared with the influence of the expansion pressure on the increase in contact area, the influence of the pressure holding time on the contact area is lower.

18.
BMC Musculoskelet Disord ; 24(1): 857, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37907910

RESUMEN

OBJECT: Varus-valgus lower alignment is a risk factor for patellofemoral osteoarthritis, but malalignment alone affect not only the tibiofemoral joint but also the patellofemoral joint. The aim of the present study was to analyse the contact area of patellofemoral joint in varus alignment and valgus alignment of healthy subjects using magnetic resonance imaging. METHODS: Twenty-six healthy subjects with valgus lower limb alignment (Group I, n = 26) and twenty-six volunteers with varus lower limb alignment (Group II, n = 26) was performed. An MRI scan was used to capture and measure the patellofemoral joint articular cartilage contact area at different degrees of knee flexion (20°, 40°,60°) in passive movement. All subjects were categorized on the basis of the global limb alignment and mechanical alignment of the femur and tibia. Varus alignment is hip-knee-ankle angle ≥ 3°; and valgus alignment is hip-knee-ankle angle ≥ - 3°. To obtain medial facet contact area and lateral facet contact area for each slice, the length of each respective line of contact was multiplied by the 5 mm slice thickness. RESULTS: The overall joint contact area increased from 168.0 ± 20.5 mm2 at 20° knee flexion to 334.4 ± 30.5 mm2 at 60° knee flexion in group (I) The overall joint contact area increased from 178.0 ± 18.9 mm2 at 20° knee flexion to 328.9 ± 27.2 mm2 at 60° knee flexion in group (II) There was a significant difference in lateral facet contact area between group I and group II at 40° of knee flexion. There was significantly different in medial facet contact area between group I and group II at 20° and 40° of knee flexion. CONCLUSIONS: Throughout the knee movement, the contact area on the lateral facet of the patellofemoral joint was greater in the valgus group. In the early phase of knee flexion, the contact area of the medial patellofemoral joint was larger in the varus group. Lower alignment is an important factor in patellofemoral joint degeneration.


Asunto(s)
Enfermedades Óseas , Osteoartritis de la Rodilla , Articulación Patelofemoral , Humanos , Articulación Patelofemoral/diagnóstico por imagen , Rodilla , Articulación de la Rodilla/diagnóstico por imagen , Extremidad Inferior , Tibia/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fenómenos Biomecánicos
19.
Biomedicines ; 11(11)2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-38001902

RESUMEN

Increased ulcer risk diminishes the quality of life in diabetes. This study assessed abnormalities in foot plantar pressure distribution in adolescents with T1D to detect early signs of ulcer risk. A total of 102 T1D patients, without diabetic neuropathy, were included (mean age 17.8 years, mean diabetes duration 7.4 year). Pedography was captured using Novel emed. Data from the study group were compared with reference data. The study revealed a statistically significant reduced foot contact area in both feet in the entire foot and under the head of the fifth metatarsal bone and the second toe. In both feet, the peak pressure was increased under the entire foot, hindfoot, midfoot, first metatarsal head, big toe, and second toe. There was no statistically significant difference in peak pressure. The mean plantar pressure rating was statistically significantly increased in both feet across the entire sole, in the hindfoot, midfoot, and first metatarsal head. T1D patients of age near adulthood without neuropathy have increased values in mean pressure and reduced contact area, pointing to the need of monitoring and preventive measures. These results point to the need of further research and analysis which should include various risk factor such as foot anatomy, body posture, or certain metabolic factors.

20.
J Dent ; 138: 104729, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37778497

RESUMEN

OBJECTIVES: The purpose of this in vitro study was to evaluate the trueness of four commercially available intraoral scanners (IOSs) on scanning different substrates that existed in the adjacent proximal contact area. METHODS: Four IOSs (TRIOS 4, TRIOS 3, Primescan, Omnicam) were used for scanning the intact enamel surface of a molar tooth, and six restorative materials (zirconia, lithium disilicate glass-ceramic, composite resin, hybrid ceramic, feldspathic ceramic, metal) that were located at the adjacent proximal contact area of the same tooth. Reference scans were obtained using an extraoral scanner (inEos X5). A 3-dimensional analyzing software (Geomagic Control X) was used to compare the reference and tested scans. The two-way analysis of variance (ANOVA) followed by Bonferroni correction was performed for statistical analyses (α=0.05). RESULTS: TRIOS 3 and TRIOS 4 showed higher trueness than Primescan, and Primescan showed higher trueness than Omnicam (p<0.001), while there were no differences between TRIOS 3 and TRIOS 4. Metal showed significantly higher Root Mean Square values (0.273 ± 0.24 mm) than other substrates. No difference was found between the scanners' zirconia, lithium disilicate glass-ceramic, composite, and feldspathic ceramic scans (p > 0.05). For the metal, TRIOS 3 and TRIOS 4 showed higher trueness than Primescan and Omnicam, while Omnicam showed lower trueness among all scanners. For the hybrid ceramic, TRIOS 3 showed higher trueness than Omnicam (p<0.001). For the enamel, TRIOS 3 showed higher trueness than Primescan and Omnicam (p<0.001). CONCLUSIONS: The trueness of IOSs can be affected by the substrates that exist in the proximal contact area. Amongst all, the metal substrate affected most the trueness of the IOSs. CLINICAL SIGNIFICANCE: The clinician should decide on the impression system, taking into account that the IOS and the surfaces to be scanned affect the trueness of the digital data. The deviation of the digital impression would be high in the presence of a metal restoration on the adjacent proximal surface.


Asunto(s)
Técnica de Impresión Dental , Imagenología Tridimensional , Diseño Asistido por Computadora , Modelos Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA