Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 275
Filtrar
1.
Cont Lens Anterior Eye ; : 102303, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39277527

RESUMEN

PURPOSE: To gain insight into patients' visual experiences and satisfaction when using different forms of myopia control lenses. METHODS: PubMed, Cochrane Library, Embase, Scopus and Web of Science databases were searched for articles assessing subjective visual quality with myopia control lenses compared with single-vision lenses (SVLs) up to July 10, 2023. Eight-hundred-and-three articles were retrieved, reviewed and any questionnaire items on subjective impressions of lens wear were meta-analysed. Subgroup analyses were based on the magnitude of defocus (add power) of multifocal soft contact lenses (MFSCLs) and age groups. A random-effects model was employed for meta-analysis, and I2 statistic used to assess the statistical heterogeneity. RESULTS: Nineteen articles fit the criteria, but only six articles involving MFSCLs had relevant data. MFSCLs were associated with lower subjective ratings of vision at different distances compared to SVLs (p < 0.001), but the differences were less than one unit. MFSCLs also yielded lower ratings when moving or walking and/or climbing stairs at -0.38 (-0.69 to -0.07, p = 0.02; I2 = 85 %, p < 0.001) and for subjective comfort (difference of -0.23, -0.41 to -0.05, p = 0.01; I2 = 63 %, p < 0.001). Subjective ratings for playing sports were not different between groups. Experience with MFSCLs was rated lower by young adults compared to children for all variables. In both children and young adults, ratings were lower with higher add compared to lower add MFSCLs. CONCLUSION: Although subjective ratings for vision and comfort were lower with MFSCLs compared to SVLs, the difference was mostly less than one unit. Importantly, young adults rated their visual experience lower compared to children.

2.
Front Med (Lausanne) ; 11: 1462205, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247637

RESUMEN

Background: Residual astigmatism is common after cataract surgery involving implantation of an intraocular lens, yet the tolerance of presbyopia-correcting intraocular lens to astigmatism of different magnitudes and axes is poorly understood. Here we compared visual acuity and quality in the presence of induced astigmatism after implantation of a trifocal or extended-depth-of-focus (EDOF) intraocular lens, the two widely used presbyopia-correcting intraocular lenses. Methods: At least 3 months after implantation of a TFNT00 or ZXR00 intraocular lens, patients were analyzed by slit-lamp examination, non-contact tonometry, subjective refraction, iTrace aberrometry, and corneal topography. After correction of residual astigmatism, astigmatism of different magnitudes on different axes was induced using cylindrical lenses, and overall visual acuity was measured, while objective visual quality was measured using the Optical Quality Analysis System II. Subjects were also asked about subjective visual quality using the Visual Function-14 questionnaire. Results: Comparison of 18 individuals who received a trifocal lens and 19 who received an EDOF lens showed that objective visual quality was better in the EDOF group regardless of the magnitude or axis of the induced astigmatism. In both groups, astigmatism of at least -1.00 DC influenced distant vision more severely when the axis was 45° than 0° or 90°, meanwhile astigmatism of at least -1.50 DC influenced near and intermediate vision more severely when the axis was 45° than 0° or 90°. Conclusion: Trifocal or EDOF intraocular lenses are less tolerant of oblique astigmatism than astigmatism with or against the rule. EDOF lenses may provide better objective visual quality than trifocal lenses in the presence of astigmatism, regardless of its magnitude or axis.

3.
Eye Vis (Lond) ; 11(1): 35, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39218909

RESUMEN

BACKGROUND: To evaluate the long-term effectiveness of orthokeratology (ortho-K) lenses with small treatment zone (STZ) or conventional treatment zone (CTZ) in controlling axial elongation in children with myopia as well as the impact on visual quality. We also sought to determine the effect of retinal visual signal quality on axial elongation. METHODS: This is a prospective randomized controlled study. A total of 140 participants (age ranging from 8 to 12 years) were randomly assigned to wear either STZ or CTZ ortho-K lenses. STZ ortho-K lenses design was achieved by changing the depth of reverse zone and the sagitta height of the optical zone. Using the IOL-Master 500, axial length (AL) was measured at baseline and after 6, 12 and 18 months of ortho-K treatment. Spherical aberration (SA) and corneal topographic parameters were obtained by the Pentacam anterior segment analyzer at baseline and the 1-month follow-up visit, and optical qualities were assessed by optical quality analysis system-II (OQAS-II) at baseline and after 1 month of lens wearing. Optical quality parameters mainly included the modulation transfer function (MTF) cutoff, Strehl ratio (SR), objective scattering index (OSI), and predicted visual acuity (PVA). RESULTS: A total of 131 participants completed the study, including 68 in the STZ group and 63 in the CTZ group. The STZ group had significantly reduced AL elongation compared to the CTZ group after treatment (12 months: 0.07 ± 0.11 mm vs. 0.14 ± 0.12 mm, P = 0.002; 18 months: 0.17 ± 0.15 mm vs. 0.26 ± 0.16 mm, P = 0.002). The topography in the STZ group showed a smaller treatment zone (TZ) diameter (2.50 ± 0.23 mm vs. 2.77 ± 0.18 mm, P < 0.001), a wider defocus ring width (2.45 ± 0.28 mm vs. 2.30 ± 0.30 mm, P = 0.006), and larger values of total amount of defocus (119.38 ± 63.71 D·mm2 vs. 91.40 ± 40.83 D·mm2, P = 0.003) and total SA (0.37 ± 0.25 µm vs. 0.25 ± 0.29 µm, P = 0.015), compared with the CTZ group. Objective visual quality decreased in both groups (P < 0.001). This was evidenced by a greater decrease in MTF cutoff (- 14.24 ± 10.48 vs. - 10.74 ± 9.46, P = 0.047) and SR values (- 0.09 ± 0.07 vs. - 0.06 ± 0.07, P = 0.026), and an increase in OSI value (0.84 ± 0.72 vs. 0.58 ± 0.53, P = 0.019). PVA9% decreased significantly in the STZ group but not the CTZ group. A statistically significant negative correlation was found between the changes in total SA and MTF cutoff values (r = - 0.202, P = 0.025). AL changes were associated with sex, change of MTF cutoff value, increment of total SA and TZ area. CONCLUSIONS: Compared with CTZ ortho-K lenses, STZ ortho-K lenses significantly inhibited axial elongation in children with myopia while moderately reducing their objective visual quality. Axial elongation was affected by retinal visual quality, and it may be a possible mechanism for ortho-K slowing myopia progression. Trial registration This trial is registered at Chinese Clinical Trial Registry on November 5, 2019 with trial registration number: ChiCTR1900027218. https://www.chictr.org.cn/showproj.html?proj=45380.

4.
BMC Ophthalmol ; 24(1): 396, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39237938

RESUMEN

BACKGROUND: This study aimed to observe corneal and retinal thicknesses at 5 years after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) for myopia, investigate the effect of epithelial remodeling on refractive status and visual quality, and compare retinal thicknesses among fundus tessellation grades. METHODS: Patients who received FS-LASIK or SMILE 5 years before were enrolled in this cross-sectional study. After 1:1 propensity score matching, each surgical group obtained 177 patients (177 eyes). Examinations including visual acuity, refraction, corneal and retinal thicknesses, corneal higher-order aberrations (HOAs), and fundus photography were performed in this visit at 5 years after surgery. The Quality of Vision (QoV) questionnaire was used to assess visual symptoms and overall satisfaction. Corneal and retinal thicknesses between groups were compared, contributing factors were analyzed, and correlations with postoperative refractive status, HOAs, QoV scores and overall satisfaction were evaluated. RESULTS: The discrepancy of epithelial thickness between central and pericentral zones in FS-LASIK group was larger than that in SMILE group, which was negatively correlated with postoperative spherical equivalent (SE), positively correlated with spherical aberration (all P < 0.05), but not correlated with QoV scores and overall satisfaction (all P > 0.05) in both surgical groups. There was no statistical difference in stromal thickness and total corneal thickness (all P > 0.05). Most annuluses of epithelial and stromal thicknesse were linearly related to preoperative SE (all P < 0.05). The macular thickness, ganglion cell complex thickness, and retinal nerve fiber layer thickness exhibited comparable values between two surgical groups and four fundus tessellation grades, with no significant association observed with postoperative SE (all P > 0.05). CONCLUSION: The tendency that epithelial thickness in central zone was thicker than peripheral zone was more obvious at 5 years after FS-LASIK compared to SMILE. This uneven distribution of epithelial thickness might play a role in myopic regression and the changes in HOAs, especially in patients with high myopia, but it had little effect on patients' subjective visual quality and satisfaction. Retinal thicknesses were not affected by these two surgical methods, and they did not appear to be the clinical indicators for myopic regression or fundus tessellation progression.


Asunto(s)
Córnea , Queratomileusis por Láser In Situ , Miopía , Refracción Ocular , Retina , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Masculino , Femenino , Miopía/cirugía , Miopía/fisiopatología , Adulto , Estudios Transversales , Agudeza Visual/fisiología , Córnea/patología , Córnea/cirugía , Córnea/diagnóstico por imagen , Refracción Ocular/fisiología , Retina/patología , Retina/diagnóstico por imagen , Adulto Joven , Tomografía de Coherencia Óptica/métodos , Láseres de Excímeros/uso terapéutico , Estudios de Seguimiento , Sustancia Propia/cirugía , Sustancia Propia/patología
5.
BMC Ophthalmol ; 24(1): 388, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227793

RESUMEN

BACKGROUND: Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. METHODS: This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. RESULTS: Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (ß = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (ß = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (ß = -16.653, P < 0.001). CONCLUSIONS: The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Femenino , Adulto , Masculino , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Láseres de Excímeros/uso terapéutico , Adulto Joven , Estudios de Seguimiento , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Sustancia Propia/cirugía , Cirugía Laser de Córnea/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Córnea/cirugía , Miopía Degenerativa/cirugía , Miopía Degenerativa/fisiopatología , Periodo Posoperatorio
6.
Am J Transl Res ; 16(7): 2995-3004, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39114707

RESUMEN

OBJECTIVE: To assess the visual quality, both subjective and objective, of cataract patients with varying axial lengths (AL) after PanOptix trifocal intraocular lens (IOL) implantation and investigated the lens tilt and its correlation with visual outcomes. METHODS: From July 2020 to June 2022, 70 patients (140 eyes) diagnosed with age-related cataracts and undergoing PanOptix implantation at Chongqing Eye and Vision Care Hospital, Aier Eye Hospital Group, were included. Patients were assigned to either the observation group (35 cases, 70 eyes with PanOptix trifocal IOL) or the control group (35 cases, 70 eyes with bifocal IOL). Patients were further subdivided based on AL into AL < 24 mm (observation group: 23 eyes; control group: 26 eyes) and AL ≥ 24 mm (observation group: 47 eyes; control group: 44 eyes). Postoperative follow-up lasted three months. Visual acuity (distant, intermediate, near), objective visual quality (Strehl ratio: SR, total eye modulation transfer function (MTF)), and visual aberrations were measured preoperatively and at 3 months post-operation. RESULTS: Postoperatively, all groups saw significant improvements in uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) compared to preoperative values (T0) (all P < 0.05). Notably, UCIVA was significantly better in the observation group than in the control group (P < 0.05). At three months (T1), reductions in total high-order aberration (tHOA), internal high-order aberration (iHOA), coma, and trefoil aberrations were observed in both groups compared to baseline, with more significant decreases in the observation group (all P < 0.05). Both SR and MTF cutoff showed marked improvement from T0 to T1, with the observation group experiencing greater enhancements (both P < 0.05). The defocus curve of the observation group showed a gentle slope between +0.5 D and -3.0 D, maintaining superior visual acuity compared to the control group (P < 0.05). Subjective visual quality scores at T1 were significantly higher than at T0 for both groups (P < 0.05), with patients in the observation group scoring higher than those in the control group across all AL categories (P < 0.05). Spearman correlation analysis indicated that the tilt after PanOptix trifocal IOL implantation was associated with tHOA (r = 0.273, P = 0.022), iHOA (r = 0.433, P < 0.001), Trefoil (r = 0.360, P = 0.002) and coma (r = 0.688, P < 0.001). CONCLUSION: PanOptix trifocal IOL implantation in cataract patients across different AL significantly enhances visual quality compared to bifocal IOLs, suggesting a strong case for its clinical adoption.

7.
PeerJ ; 12: e17940, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39184392

RESUMEN

Purpose: To compare the visual quality after wavefront-guided femtosecond LASIK (WFG FS-LASIK) in patients with different levels of preoperative total ocular higher-order aberrations to guide clinical decision-making regarding patient selection and treatment strategies. Methods: This study included 112 right eyes of 112 patients who previously underwent WFG FS-LASIK for correcting myopia and myopic astigmatism. The patients were divided into two groups based on the mean values of preoperative total ocular HOAs (0.30 ± 0.09 µm): HOA ≤ 0.3 and > 0.3 groups. The visual acuity, manifest refraction, corneal Strehl ratio (SR), root mean square (RMS) of corneal and ocular aberrations, and area under the log contrast sensitivity function (AULCSF) of both groups were compared preoperatively and at 1, 3, 6, and 12 months postoperatively. Results: The induced ocular HOAs and coma (Δ = 1 mo - Preop) were significantly lower in the HOAs > 0.3 group than in the HOAs ≤ 0.3 group (ΔHOAs: 0.39 ± 0.19 vs. 0.29 ± 0.18 µm, t = 2.797, P = 0.006; Δ coma: 0.30 ± 0.19 vs. 0.20 ± 0.21 µm, t = 2.542, P = 0.012). In the HOAs > 0.3 group, ΔHOAs were negatively correlated with the preoperative ocular HOAs (r = -0.315, P = 0.019). In the HOAs ≤ 0.3 group, the regression equation for Δ HOAs = 0.098 + 0.053 |SE| (F = 21.756, P < 0.001). In the HOAs > 0.3 group, the regression equation for ΔHOAs = 0.534 - 1.081 HOAs + 0.038|Sphere| (F = 7.954, P = 0.001). The postoperative uncorrected distance visual acuity, spherical equivalent, corneal aberrations, SR and AULCSF of both groups were similar (all P > 0.05). Furthermore, the ocular aberrations were not significantly different between both groups at 3, 6, and 12 months postoperatively (all P > 0.05). In addition, compared with the preoperative period, the AULCSF of both groups were significantly increased in the postoperative period (all P < 0.05). Conclusions: The induced ocular HOAs and coma in HOAs > 0.3 group were lower. However, both groups achieved equivalent and excellent visual quality after WFG FS-LASIK. WFG FS-LASIK may provide significant visual benefits for a wider range of patients.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Femenino , Masculino , Agudeza Visual/fisiología , Adulto , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Resultado del Tratamiento , Persona de Mediana Edad , Sensibilidad de Contraste/fisiología
8.
World J Clin Cases ; 12(19): 3882-3889, 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38994309

RESUMEN

BACKGROUND: Cataracts pose a significant clinical burden due to their complex pathogenesis. In recent years, an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment. Additionally, symptoms of ocular axis elongation, lens nucleus hardening, and vitreous liquefaction have become more prevalent. While conventional extracapsular cataract extraction is commonly employed, it often yields suboptimal visual outcomes. Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity. AIM: To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract. METHODS: We selected 110 patients (with 134 eyes) with myopia and cataracts treated. These patients were categorized into two groups: an observation group (57 patients with 70 eyes) and a control group (53 patients with 64 eyes). The control group underwent cataract phacoemulsification and lens implantation, while the observation group received a refined capsular treatment based on the control group's procedure. We assessed the differences in visual acuity and quality between the two groups before and after surgery. RESULTS: At six months post-operation, the observation group exhibited significantly improved far vision, intermediate vision, near vision, lower objective scattering index, higher Modulation transfer function cut-off frequency, and overall vision metrics at different contrast levels (100%, 20% and 9%) compared to the control group (P < 0.05). The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group (P < 0.05). No significant difference in the incidence of adverse reactions was observed between the observation group and control group (P > 0.05). CONCLUSION: Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts, warranting its clinical application.

9.
Adv Ophthalmol Pract Res ; 4(3): 134-141, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38947252

RESUMEN

Objective: To develop and evaluate a Chinese version of the Symptom Questionnaire for Visual Dysfunctions (CSQVD) to quantify visual dysfunction symptoms in school-age children with various eye diseases, and to explore the relationship between ophthalmological disorders and visual dysfunction symptoms. Methods: Following standard scale adaptation procedures, the Symptom Questionnaire for Visual Dysfunctions (SQVD) was translated into Chinese (CSQVD). We employed random sampling to survey 198 outpatients aged 7-18 to assess the psychometric properties of the CSQVD. Using the reliable and validated questionnaire, we evaluated the determinants of visual dysfunction symptoms among 406 school-age patients at an eye center. The CSQVD scores were correlated with demographic and clinical variables, including gender, age, eye position, refractive power, and best-corrected visual acuity. Univariate analysis identified potential risk factors, followed by binary logistic regression and multiple linear regression analysis on factors with a P-value <0.05. Results: The CSQVD scale's critical ratio (CR) values ranged from 6.028 to 10.604. The Cronbach's Alpha coefficient was 0.779, and Spearman-Brown split-half reliability was also 0.779. The I-CVI varied from 0.83 to 1.000, the S-CVI/Ave was 0.857, and the KMO value was 0.821. Multifactorial regression analysis indicated that high myopia (OR â€‹= â€‹5.744, 95% CI [1.632, 20.218], P â€‹= â€‹0.006) and amblyopia (OR â€‹= â€‹9.302, 95% CI [1.878, 46.058], P â€‹= â€‹0.006) were significant predictors of CSQVD symptoms. Multiple linear regression analysis showed that BCVA of amblyopic eyes (B â€‹= â€‹-5.052, 95% CI [-7.779, 2.325], P â€‹= â€‹0.000) and SE power (B â€‹= â€‹-0.234, 95% CI [-0.375, 0.205], P â€‹= â€‹0.001) significantly affected the CSQVD scale scores. Conclusions: The Chinese version of the SQVD scale (CSQVD) demonstrates good feasibility, discriminatory power, validity, and reliability in assessing Chinese school-aged children. Furthermore, those who have severe myopia and amblyopia reported more visual dysfunction symptoms.

10.
J Clin Med ; 13(14)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39064176

RESUMEN

Background/Objectives: To evaluate the clinical and patient-reported outcomes (PROMs) obtained with an optimized version of a previously investigated trifocal IOL. Methods: Prospective non-comparative single-center study enrolling 29 patients (55-71 years) undergoing bilateral cataract surgery with implantation of the trifocal diffractive IOL Liberty 677CMY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary). Visual and refractive outcomes as well as PROMs were evaluated during a 3-month follow-up: measurement of uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, DCIVA) and near visual acuities (UNVA, DCNVA), defocus curve, patient satisfaction, photic phenomena perception, spectacle independence, and difficulty in performing some vision-related activities. Results: A total of 100%, 92%, and 80% of patients achieved a postoperative binocular UDVA, UIVA, and UNVA of 20/25 or better, respectively. Likewise, 100%, 80%, and 84% of patients achieved a postoperative binocular CDVA, DCIVA, and DCNVA of 20/25 or better, respectively. In the defocus curve, all mean visual acuity values were better than 0.15 logMAR for all defocus levels. A total of 95.8%, 95.8%, and 91.7% of patients referred to be satisfied with their distance, intermediate, and near visual vision, respectively. Mean overall Catquest Rasch calibrated score was -3.12 ± 0.98. Most of the patients were spectacle independent: far (95.8%), intermediate (95.8%) or near vision (91.7%). No bothersome or minimal to moderately bothersome halo, starburst, and glare was perceived by 83.3%, 83.4%, and 83.3% of patients, respectively. Conclusions: The trifocal IOL evaluated provides a visual acuity improvement, with high levels of spectacle independence, patient satisfaction, and perceived visual quality associated.

11.
Int J Ophthalmol ; 17(6): 1086-1093, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38895689

RESUMEN

AIM: To evaluate the effect of low-degree astigmatism on objective visual quality through the Optical Quality Analysis System (OQAS). METHODS: This study enrolled 46 participants (aged 23 to 30y, 90 eyes) with normal or corrected-to-normal vision. The cylindrical lenses (0, 0.5, 0.75, 1.0, and 1.25 D) were placed at the axial direction (180°, 45°, 90°, and 135°) in front of the eyes with the best correction to form 16 types of regular low-degree astigmatism. OQAS was used to detect the objective visual quality, recorded as the objective scattering index (OSI), OQAS values at contrasts of 100%, 20%, and 9% predictive visual acuity (OV100%, OV20%, and OV9%), modulation transfer function cut-off (MTFcut-off) and Strehl ratio (SR). The mixed effect linear model was used to compare objective visual quality differences between groups and examine associations between astigmatic magnitude and objective visual quality parameters. RESULTS: Apparent negative relationships between the magnitude of low astigmatism and objective visual quality were observed. The increase of OSI per degree of astigmatism at 180°, 45°, 90°, and 135° axis were 0.38 (95%CI: 0.35, 0.42), 0.50 (95%CI: 0.46, 0.53), 0.49 (95%CI: 0.45, 0.54) and 0.37 (95%CI: 0.34, 0.41), respectively. The decrease of MTFcut-off per degree of astigmatism at 180°, 45°, 90°, and 135° axis were -10.30 (95%CI: -11.43, -9.16), -12.73 (95%CI: -13.62, -11.86), -12.75 (95%CI: -13.79, -11.70), and -9.97 (95%CI: -10.92, -9.03), respectively. At the same astigmatism degree, OSI at 45° and 90° axis were higher than that at 0° and 135° axis, while MTFcut-off were lower. CONCLUSION: Low astigmatism of only 0.50 D can significantly reduce the objective visual quality.

12.
Clin Ophthalmol ; 18: 1491-1501, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827774

RESUMEN

Purpose: To evaluate binocular intermediate visual acuity (IVA), depth of focus, and other visual outcomes achieved with a monofocal aspheric intraocular lens (IOL) using pooled data from 2 randomized, double-masked, controlled trials. Patients and Methods: The studies conducted at 32 sites included patients aged ≥22 years with bilateral cataracts, preoperative corneal astigmatism 1.0 D, and lens power 18.0-25.0 D. Patients received bilateral AcrySof IQ IOLs (SN60WF). Primary endpoint data were collected at month 6. Binocular uncorrected and corrected distance visual acuity (UDVA and CDVA) at 4 m, binocular uncorrected and corrected IVA (UIVA and DCIVA) at 66 cm, manifest refraction spherical equivalent (MRSE), and binocular defocus curve at 4 m were assessed under photopic conditions. Validated questionnaires were used to assess spectacle use and quality of vision. Results: Of 233 patients who received SN60WF, 228 had visual acuity data at 6 months. Under photopic conditions, 51% of the eyes had pupils >4 mm, 40% had pupils 3-4 mm, and 9% had pupils <3 mm. Mean ± SD UDVA and CDVA were -0.019 ± 0.110 and -0.088 ± 0.082 logMAR, respectively. Mean ± SD UIVA and DCIVA were 0.125 ± 0.145 and 0.196 ± 0.139 logMAR, respectively. UIVA and DCIVA of 20/32 or better were achieved by 83% (188/228) and 71% (162/228) of patients, respectively. Mean ± SD MRSE was -0.007 ± 0.404 D for the first eye and 0.036 ± 0.371 for the second eye. The defocus curve demonstrated binocular vision of 0.24 logMAR or better from +1.2 to -1.5 D. Spectacle independence for distance and intermediate vision was reported by 86% and 41% of the patients, respectively. Based on questionnaires, 61%, 79%, and 65% of the patients did not experience starbursts, halos, or glare. Conclusion: A monofocal aspheric IOL (SN60WF) assessed in a large, pooled study provided excellent distance vision and clinically functional intermediate vision.

13.
Clin Exp Optom ; : 1-10, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38806402

RESUMEN

CLINICAL RELEVANCE: microRNAs have been found to be involved in the progression of a variety of ocular diseases. BACKGROUND: Cataract and glaucoma often coexist, and combined surgery is a common treatment. The aim of this study is to analyse the correlation between miR-26a and visual quality in cataract patients with glaucoma. METHODS: Seventy patients with cataract and glaucoma and 70 healthy volunteers were enrolled and received phacoemulsification and trabeculectomy. The patients were divided into low and high miR-26a expression groups according to miR-26a mean expression. The objective scattering index, strehl ratio, and modulated transfer function cut-off were analysed by optical quality analysis system II. The changes of miR-26a, objective scattering index, strehl ratio, modulated transfer function cut-off, and the correlation between the indicators were analysed. The downstream genes of miR-26a were analysed by Gene Ontology and Kyoto Encyclopaedia of Genes and Genomes functional enrichment. RESULTS: There were significant differences between patients and controls in lipid biomarker levels and visual indicators. miR-26a was decreased in the patient group. Strehl ratio and modulated transfer function cut-off in the miR-26a low-expression group were lower than in high-expression group, while mean defect of the visual field and objective scattering index were higher than in high-expression group. The miR-26a expression was negatively correlated with the severity of disease and objective scattering index, and positively correlated with strehl ratio and modulated transfer function cut-off. After surgery, miR-26a, strehl ratio, and modulated transfer function cut-off were increased, and objective scattering index was decreased. The downstream genes of miR-26a were related to several biological processes and signalling pathways. CONCLUSION: In cataract patients with glaucoma, miR-26a expression was lower than matched controls and increased following combined cataract removal and trabeculectomy.

14.
Int J Ophthalmol ; 17(3): 499-508, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721516

RESUMEN

AIM: To assess effectivity and safety of trifocal intraocular lenses (IOLs) and capsular tension rings in treating cataract patients with axial high myopia. METHODS: A prospective nonrandomized controlled clinical trial was conducted. Totally 98 eyes (74 patients) who underwent femtosecond laser-assisted cataract surgery (FLACS) with trifocal IOLs were enrolled in the study and followed up for 2y after surgery: 46 eyes (33 patients) with capsular tension ring implantation in the long axial lengths (AL) group (260.05). The dysfunctional lens index and total modulation transfer function (MTF) average height were similar between the two groups. The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group (P<0.05). The total satisfaction score in the long AL group (91.32±2.76) was slightly higher than that in the normal AL group (90.36±3.47), but there was no difference (P=0.136). A statistically negative correlation was found between corrected distance visual acuity (CDVA) and dysfunctional lens index (r=-0.382, P=0.009), and between CDVA and the total MTF average height (r=-0.374, P=0.01). But there was no significant correlation between CDVA and total satisfaction score (r=0.059, P=0.696). Postoperative complications mainly presented as posterior capsular opacity (PCO), retinal detachment and cystoid macular edema. There was no difference in the incidence of fundus disease (6.5% vs 3.8%, P=0.663) or PCO (17.4% vs 7.7%, P=0.217) between the two groups at two years. CONCLUSION: The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS. This approach not only ensures excellent subjective feelings and objective visual quality, but also does not increase the incidence of postoperative complications.

15.
Ear Nose Throat J ; : 1455613241255996, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783576

RESUMEN

Objectives: This study aims to investigate the contributions of the filler procedure performed in the malar region to the patient's appearance as visual quality and quality of life. Methods: A total of 72 patients who underwent a malar filler procedure between March 2022 and March 2023 were included in the study. Each patient received a 2 cc injection of hyaluronic acid filler, with 1 cc administered on the right and 1 cc on the left. Photos before the malar filler procedure and photos taken in the first month after the procedure for individuals included in the study were independently evaluated by 2 physicians. Change criteria were rated on a scale of 1 to 5 as follows: (1) no change, (2) slight change, (3) moderate change, (4) significant change, and (5) very significant change. The satisfaction of the patients related to the malar filler procedure was evaluated by a Visual Analogue Scale (VAS) scale of 1 to 10 (0 showing no satisfaction, 10 showing maximum satisfaction). Results: Physicians evaluated the visual appearance of the patients as a "very significant change" in all patients (100%). Of the 72 patients, 66 (91.6%) expressed satisfaction with the procedure, while 6 (8.4%) found the treatment insufficient and requested further interventions. Conclusion: Hyaluronic acid fillers applied to the malar region caused patient satisfaction in 91.6%. However, a few patients requested further interventions. Patients' requests for unnecessary operations should be noted and treated with caution since they may lead doctors in the wrong direction.

16.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627651

RESUMEN

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Presbiopía , Agudeza Visual , Humanos , Presbiopía/cirugía , Presbiopía/fisiopatología , Agudeza Visual/fisiología , Extracción de Catarata/métodos , Sensibilidad de Contraste/fisiología , Implantación de Lentes Intraoculares/métodos , Diseño de Prótesis , Visión Binocular/fisiología , Refracción Ocular/fisiología
17.
Curr Eye Res ; 49(2): 188-196, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37846084

RESUMEN

PURPOSE: To assess the association of fundus tessellation with contrast sensitivity, Quality of Vision questionnaire, and other factors at five years postcorneal refractive surgery. METHODS: This is a cross-sectional study. Both eyes of 98 subjects (196 eyes) who received femtosecond laser in situ keratomileusis (FS-LASIK) or small incision lenticular extraction (SMILE) five years prior were enrolled in this study. Fundus tessellation was imaged using wide-angle fundus photographs and graded into four categories with the assistance of the ETDRS grid. Photopic and mesopic contrast sensitivity were measured under the best correction. The Quality of Vision (QoV) questionnaire was used to assess visual symptoms. RESULTS: Fundus tessellation was classified as follows: 19 eyes were grade 0 (9.7%), 28 eyes were grade 1 (14.3%), 59 eyes were grade 2 (30.1%), and 90 eyes were grade 3 (45.9%). Higher degrees of fundus tessellation were associated with lower photopic contrast sensitivity, a significant difference was observed at spatial frequencies of 6cpd (p = 0.030, grade 1 >grade 3 p = 0.011). Higher degrees of fundus tessellation were also associated with lower mesopic contrast sensitivity, a significant difference was observed at spatial frequencies of 18cpd (p = 0.011, grade 0 >grade 3 p = 0.012). The preoperative degree of myopia was positively associated with fundus tessellation grade (p < 0.001). However, in linear mixed-effect model analysis, no significant influence of parameters (contrast sensitivity, preoperative myopia, and QoV scores) upon different tessellation grades was found (p > 0.05). CONCLUSIONS: Patients with moderate and high myopia were more likely to have higher grades of fundus tessellation. Higher degree of fundus tessellation associates with lower contrast sensitivity. Patients with moderate and high myopia should be concerned with retinal-choroidal changes. Contrast sensitivity could be a clinical sign for progression of tessellation and used to screen for early retinal-choroidal changes to prevent pathologic myopia.


Asunto(s)
Anomalías del Ojo , Queratomileusis por Láser In Situ , Miopía , Humanos , Sensibilidad de Contraste , Agudeza Visual , Estudios Transversales , Láseres de Excímeros , Queratomileusis por Láser In Situ/métodos , Miopía/diagnóstico , Miopía/cirugía , Refracción Ocular , Sustancia Propia/cirugía
18.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1022712

RESUMEN

Objective To investigate the effect of residual corneal astigmatism on visual acuity after regional refrac-tive intraocular lens(IOL)implantation.Methods A retrospective cohort study was conducted.The medical records and follow-up data of 73 eyes of 57 cataract patients who underwent ultrasound emulsification cataract extraction combined with LENTIS Comfort LS-313 MF15 IOL implantation in the Ophthalmology Department of the Hebei General Hospital from June 2020 to March 2022 were collected.These patients were grouped according to postoperative residual corneal astigmatism:32 patients(40 eyes)with a residual corneal astigmatism of 0.75(exclusive)-1.50 D were taken as the experimental group,and 25 patients(33 eyes)with a residual corneal astigmatism ≤0.75 D were taken as the control group.The uncor-rected distance visual acuity(5 m),uncorrected intermediate visual acuity(80 cm),uncorrected near visual acuity(40 cm),out-of-focus curve,objective visual quality,subjective visual quality,satisfaction degree and lens removal rate of pa-tients in the two groups were recorded 6 months postoperatively.Results The postoperative uncorrected distance visual acuity(logMAR)was 0.10(0.00,0.22),the uncorrected intermediate visual acuity(logMAR)was 0.00(0.00,0.10),and the uncorrected near visual acuity(logMAR)was 0.20(0.10,0.30)and 0.20(0.10,0.20)in the experimental and control groups,with no statistically significant differences(all P>0.05).The postoperative out-of-focus curves showed that the distance visual acuity of patients with additional spherical equivalent refraction ranged from+2.00 D to-4.00 D in the two groups had no statistically significant difference(all P>0.05).There were statistically significant differences in to-tal aberration,coma aberration,modulation transfer function and Strehl ratio in the objective visual quality of patients after surgery(all P<0.05),and there was no statistically significant difference in the total higher-order aberration,spherical ab-erration and cloverleaf aberration(all P>0.05).There was no statistically significant difference in the subjective visual quality,satisfaction degree and lens removal rate in the two groups(all P>0.05).Conclusion Residual corneal astig-matism of 0.75 D to 1.50 D after LENTIS Comfort LS-313 MF15 IOL implantation has no effect on higher-order aberration,spherical aberration,and cloverleaf aberration in subjective and objective visual quality,and has an impact on total aberra-tion,coma aberration,modulation transfer function and Strehl ratio in objective visual quality.

19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1022849

RESUMEN

Objective:To investigate the correlation between low-order and high-order aberrations and objective depth of focus in the human eye, and the factors that influence objective depth of focus.Methods:A cross-sectional study was performed.Seventy-six patients (152 eyes) with myopia and astigmatism patients who were treated at the Refractive Surgery Center of Tianjin Eye Hospital from February to April 2022 were selected, including 41 males and 35 females.The patients' whole-eye low-order and high-order aberrations and objective depth of focus were measured at 3, 4, 5, and 6 mm manually selected pupil diameters using the iTrace visual function analyzer.The correlation between objective depth of focus and low-order and high-order aberrations at different pupil diameters was analyzed by Spearman rank correlation analysis.Objective depth of focus was compared between individuals with different degrees of myopia and astigmatism, individuals with different pupil diameters, right and left eyes, and different sexes.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Tianjin Eye Hospital (No.2022039).Results:Objective depth of focus was positively correlated with total low-order aberrations at 3, 4, 5, and 6 mm pupil diameter ( rs=0.380, 0.317, 0.385, 0.519, all at P<0.01). Objective depth of focus was positively correlated with defocus at 3, 4, 5, and 6 mm pupil diameter ( rs=0.377, 0.323, 0.403, 0.512, all at P<0.01), and with astigmatism at 6 mm pupil diameter ( rs=0.255, P<0.05). There were statistically significant overall differences in objective depth of focus between groups with different degrees of myopia at 3, 4, 5, and 6 mm pupil diameter ( H=6.440, 7.370, 9.990, 16.930; all at P<0.05). Among them, the objective depth of focus of high myopia was significantly higher than that of low myopia at different pupil diameters, and the objective depth of focus of high myopia was higher than that of moderate myopia at 6 mm pupil diameter, with statistically significant differences (all at P<0.05). Objective depth of focus was positively correlated with total high-order aberration at pupil diameters of 3, 4, 5, and 6 mm ( rs=0.911, 0.807, 0.733, 0.677; all at P<0.001). Among various high-order aberrations, objective depth of focus was positively correlated with total coma at 3, 4, 5, and 6 mm pupil diameter ( rs=0.727, 0.557, 0.620, 0.487; all at P<0.001), positively correlated with vertical coma at 3, 4, 5, and 6 mm pupil diameter ( rs=0.439, 0.405, 0.553, 0.400; all at P<0.001), positively correlated with horizontal coma at 5 and 6 mm pupil diameter ( rs=0.308, 0.308; both at P<0.01), positively correlated with trefoil aberration at 3, 4, 5, and 6 mm pupil diameter ( rs=0.344, 0.443, 0.316, 0.330; all at P<0.01), positively correlated with spherical aberration at 4, 5, and 6 mm pupil diameter ( rs=0.321, 0.310, 0.428; all at P<0.01). There was a significant difference in objective depth of focus between 3 and 4 mm, 5 and 6 mm pupil diameters ( P=0.011, 0.004). There was no statistically significant difference in objective depth of focus between different degrees of astigmatism, between males and females, or between left and right eyes (all at P>0.05). Conclusions:The objective depth of focus of the human eye is mainly strongly correlated with vertical coma, trefoil aberration in high-order aberrations, as well as defocus in low-order aberrations.Horizontal coma and spherical aberration are strongly correlated with objective depth of focus only when the pupil diameter is large.In addition, if the pupil diameter is too small (3 mm) or too large (6 mm), it has a significant effect on the objective depth of focus.

20.
International Eye Science ; (12): 870-875, 2024.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1030811

RESUMEN

AIM:To compare the corneal refractive power and visual quality after three kinds of corneal refractive surgery: laser subepithelial keratomileusis(LASEK), transepithelial photorefractive keratectomy(TransPRK)and femtosecond laser assisted in situ keratomileusis(FS-LASIK).METHODS: Retrospective study. A total of 232 patients(464 eyes)who underwent elective corneal refractive surgery in our hospital from January 2021 to December 2022 were selected as the study subjects. They were divided into the LASEK group of 70 cases(140 eyes), TransPRK group of 76 cases(152 eyes), and FS-LASIK group of 86 cases(172 eyes)according to the different surgical choices made by the patients. Uncorrected visual acuity(UCVA), visual quality, biomechanical stability, tear film break-up time(BUT), Schirmer Ⅰ test(SⅠt)and quality of life were compared among the three groups at 1 and 3 mo postoperatively.RESULTS: The UCVA of the three groups significantly improved at 1 and 3 mo postoperatively, the total high-order aberrations, spherical aberration, horizontal coma, and vertical coma of the entire cornea were significantly increased, while the biomechanical stability in all three groups were significantly reduced(all P&#x003C;0.05). At 3 mo postoperatively, the biomechanical stability in the TransPRK and LASEK groups were higher than those of the FS-LASIK group(all P&#x003C;0.05), and the TransPRK group had higher quality of life scores than the LASEK group and FS-LASIK group(P&#x003C;0.05). Furthermore, there was no significant difference in preoperative or postoperative BUT and SⅠt among the three groups(all P&#x003E;0.05).CONCLUSION:In the treatment of ametropia, LASEK, TransPRK and FS-LASIK all have certain effects, and have similar results in improving UCVA and increasing visual quality. However, TransPRK and LASEK have more stable biomechanical properties than FS-LASIK, and have better efficacy in improving patients' quality of life.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA