Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur J Neurol ; 31(3): e16167, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38009830

RESUMEN

BACKGROUND AND PURPOSE: Several previous studies have shown that skin sebum analysis can be used to diagnose Parkinson's disease (PD). The aim of this study was to develop a portable artificial intelligence olfactory-like (AIO) system based on gas chromatographic analysis of the volatile organic compounds (VOCs) in patient sebum and explore its application value in the diagnosis of PD. METHODS: The skin VOCs from 121 PD patients and 129 healthy controls were analyzed using the AIO system and three classic machine learning models were established, including the gradient boosting decision tree (GBDT), random forest and extreme gradient boosting, to assist the diagnosis of PD and predict its severity. RESULTS: A 20-s time series of AIO system data were collected from each participant. The VOC peaks at a large number of time points roughly concentrated around 5-12 s were significantly higher in PD subjects. The gradient boosting decision tree model showed the best ability to differentiate PD from healthy controls, yielding a sensitivity of 83.33% and a specificity of 84.00%. However, the system failed to predict PD progression scored by Hoehn-Yahr stage. CONCLUSIONS: This study provides a fast, low-cost and non-invasive method to distinguish PD patients from healthy controls. Furthermore, our study also indicates abnormal sebaceous gland secretion in PD patients, providing new evidence for exploring the pathogenesis of PD.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/patología , Inteligencia Artificial , Aprendizaje Automático
2.
Phytochem Anal ; 34(5): 594-605, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37282799

RESUMEN

INTRODUCTION: Ssajuari-ssuk and sajabal-ssuk have many clinical benefits. It is difficult to discriminate between these two species based on general characteristics aside from the shapes of the leaves. Thus, species identification and quality control between ssajuari-ssuk and sajabal-ssuk are of great concern in plant science and clinical therapy. OBJECTIVE: The aim of this study is to determine whether fast gas chromatography with uncoated surface acoustic wave sensor (GC-SAW) can be a useful technique for performing species identification and quality control using volatile patterns of ssajuari-ssuk and sajabal-ssuk air-dried for 4 months and 2 years and 4 months. METHODOLOGY: Fast GC-SAW sensor provides second unit analysis, simple, on-line measurements that do not require pretreatment of the sample and rapid sensory information. Headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) was employed to confirm the identification of the volatiles and compared to fast GC-SAW sensor. RESULTS: In air-dried sajabal-ssuk, the concentration of 1,8-cineole was higher than that in air-dried ssajuari-ssuk, while the level of α-thujone was considerably lower than that of air-dried ssajuari-ssuk. Each of ssajuari-ssuk and sajabal-ssuk air-dried for 4 months and 2 years and 4 months has its own characteristic volatile pattern owing to its individual chemotypes or chemical compositions. CONCLUSION: Consequently, the fast GC-SAW sensor can be a useful technique for species identification and quality control using volatile patterns of ssajuari-ssuk and sajabal-ssuk air-dried for 4 months and 2 years and 4 months. This method can be used for the standardisation of quality control using volatile patterns of herbal medicines.


Asunto(s)
Artemisia , Compuestos Orgánicos Volátiles , Cromatografía de Gases y Espectrometría de Masas/métodos , Artemisia/química , Sonido , Control de Calidad , República de Corea , Compuestos Orgánicos Volátiles/análisis , Microextracción en Fase Sólida/métodos
3.
Nanomaterials (Basel) ; 13(3)2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-36770426

RESUMEN

In recent years, with the rapid development of flexible electronic devices, researchers have a great interest in the research of electronic skin (e-skin). Traditional e-skin, which is made of rigid integrated circuit chips, not only limits the overall flexibility, but also consumes a lot of power and poses certain security risks to the human body. In this paper, a wireless passive e-skin is designed based on the surface acoustic wave sensor (SAWS) of lithium niobate piezoelectric film. The e-skin has the advantages of small size, high precision, low power consumption, and good flexibility. With the multi-sensing function of stress, temperature, and sweat ion concentration, etc., the newly designed e-skin is a sensor platform for a wide range of external stimuli, and the measurement results can be directly presented in frequency. In order to explore the characteristic parameters and various application scenarios of the SAWS, finite element analysis is carried out using the simulation software; the relationship between the SAWS and various influencing factors is explored, and the related performance curve is obtained. These simulation results provide important reference and experimental guidance for the design and preparation of SAW e-skin.

4.
Sensors (Basel) ; 22(17)2022 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-36080914

RESUMEN

In this paper, we investigate the application of using software-defined radio (SDR) and surface acoustic wave (SAW) device for wireless measurement of the response of in situ sensors. SDR uses software to realize different communication functions. After collecting the magnitude and phase of the response at discrete frequencies, we apply inverse Fourier transform to analyze the time domain responses which, in turn, allows for monitoring the changes of the response of the in situ sensor. We employ microwave signal flow graph concepts to improve the quality of the received signals. Comparing the normalized results obtained by SDR with those obtained from a commercial vector network analyzer (VNA), we demonstrate that the results are sufficiently close, and the SDR-based experiments can provide satisfactory measurement of the in-situ sensors. The objective is to eventually employ this wireless measurement system for soil nutrient sensing.


Asunto(s)
Programas Informáticos , Tecnología Inalámbrica
5.
Sensors (Basel) ; 21(24)2021 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-34960260

RESUMEN

In this work, the first surface acoustic-wave-based magnetic field sensor using thin-film AlScN as piezoelectric material deposited on a silicon substrate is presented. The fabrication is based on standard semiconductor technology. The acoustically active area consists of an AlScN layer that can be excited with interdigital transducers, a smoothing SiO2 layer, and a magnetostrictive FeCoSiB film. The detection limit of this sensor is 2.4 nT/Hz at 10 Hz and 72 pT/Hz at 10 kHz at an input power of 20 dBm. The dynamic range was found to span from about ±1.7 mT to the corresponding limit of detection, leading to an interval of about 8 orders of magnitude. Fabrication, achieved sensitivity, and noise floor of the sensors are presented.

6.
Molecules ; 26(19)2021 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-34641341

RESUMEN

INTRODUCTION: A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC-SAW) was developed for rapid determination of the pharmacological volatiles of turmeric (Curcuma longa L.). METHODS: The volatile compounds in 20 turmeric samples, collected from different parts and different origins, were assessed by the fast GC-SAW. In addition, gas chromatography-mass spectrometry (GC-MS) was employed to confirm the chemical composition of the main volatiles. The digital fingerprint of turmeric was established and analysed by principal component analysis and cluster analysis. RESULTS: Curcumene (9.1%), ß-sesquiphellandrene (5.1%) and ar-turmerone (69.63%) were confirmed as the main pharmacological volatiles of turmeric. The content of ar-turmerone in lateral rhizome turmeric was significantly higher than that of top rhizome and ungrouped turmeric. The contents of curcumene and ß-sesquiphellandrene in top rhizome turmeric were higher than those in lateral and ungrouped turmeric. The 20 turmeric samples were divided into four categories, which reflected the quality characteristics of the turmeric from different parts and origins. CONCLUSION: The GC-SAW method can rapidly and accurately detect pharmacologically volatiles of turmeric, and it can be used in the quality control of turmeric.


Asunto(s)
Curcuma/química , Rizoma/química , Compuestos Orgánicos Volátiles/análisis , Análisis por Conglomerados , Cromatografía de Gases y Espectrometría de Masas , Especificidad de Órganos , Extractos Vegetales/análisis , Extractos Vegetales/química , Análisis de Componente Principal , Sonido , Compuestos Orgánicos Volátiles/química
7.
Phytochem Anal ; 32(5): 710-723, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33354846

RESUMEN

INTRODUCTION: Korean mugwort has been used as a traditional medicine. Specifically, air-dried Artemisia princeps Pamp. cv. ssajuari (ssajuari-ssuk; Korean mugwort) has been used as moxa in moxibustion therapy. Thus, the evaluation of high quality ssajuari-ssuk containing herbal volatiles is of great interest in clinical therapy and the food industry. OBJECTIVE: The aim of this study is to determine whether fast gas chromatography with uncoated surface acoustic wave (fast GC/SAW) sensor can be a useful technique for performing quality control using herbal volatiles of ssajuari-ssuk air-dried for different times. METHODOLOGY: Fast GC/SAW sensor, called "Electronic zNose", is also a headspace sampling method and is an effective simple analytical method with a second unit analysis providing on-line measurements without the need for pretreatment of the sample. Headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) was employed to confirm the identification of the volatiles and compared to fast GC/SAW sensor. RESULTS: Artemisia princeps Pamp. cv. ssajuari air-dried for 2 years and 4 months (the third year), containing the highest total amount of herbal volatiles, was superior to the others (the first year, the second year, the fourth year) in quality. Moreover, fast GC/SAW sensor shows a high repeatability (relative standard deviation 0.77% âˆ¼ 6.23%), excellent sensitivity (limit of detection value of 0.47 pg/mL), and good linearity (correlation coefficient r2 = 0.997) over the range of nanogram for α-thujone. CONCLUSION: Therefore, the fast GC/SAW sensor can be a useful analytical method for the discrimination and quality control of volatiles of herbal and medicinal plants according to air-drying time, as it provides a simple and second unit analysis.


Asunto(s)
Artemisia , Compuestos Orgánicos Volátiles , Humanos , Electrónica , Cromatografía de Gases y Espectrometría de Masas , Control de Calidad , República de Corea , Microextracción en Fase Sólida , Sonido , Compuestos Orgánicos Volátiles/análisis
8.
Methods Enzymol ; 642: 435-468, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32828264

RESUMEN

Gravimetric transducers produce a signal based on a change in mass. These transducers can be used to construct gas sensors or biosensors using odorant binding proteins (OBPs) as recognition elements for small volatile organic compounds. The methods described in this chapter are based on the immobilization of the OBPs onto functionalized (activated) self-assembled monolayer (SAMs) on gold and on nanocrystalline diamond surfaces. Depending on the surface immobilization methods used to fabricate the biosensor, recombinant proteins can be engineered to express six histidine tags either on the N-terminal or C-terminal of the proteins and these can also be used to facilitate protein immobilization. These methods are used to produce functional sensors based on quartz crystal microbalances or surface acoustic wave devices and are also applicable to other types of gravimetric transducers.


Asunto(s)
Técnicas Biosensibles , Tecnicas de Microbalanza del Cristal de Cuarzo , Oro , Histidina , Proteínas
9.
Sensors (Basel) ; 20(8)2020 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-32290628

RESUMEN

On site monitoring of engine oil is required. The features of a shear horizontal surface acoustic wave (SH-SAW) sensor include simultaneous detection of mechanical and electrical properties of liquids (such as viscosity, relative permittivity, and conductivity) and loaded mass on the sensor surface. In this paper, the used engine oil extracted from a motorbike was measured using the SH-SAW sensor. The degradation factors of the used engine oil were experimentally discussed. Especially, the influences of the particles in the engine oil, heating effect, and water contained in the engine oil were considered by comparing the differences between new and used engine oils. The results indicate that the influence of the water contained in the engine oil is the primary cause of the degradation of the used engine oil.

10.
Sensors (Basel) ; 18(12)2018 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-30518102

RESUMEN

Developing a controlled method for obtaining hybrid enzymatic-based interfaces for sensing application require the use of a multiuse, reusable sensor. By controlling the interface characteristics in terms of the surface chemistry, thickness, and roughness, a tailored response toward various toxic compounds can be obtained, regarding both materials used as active surfaces and fabrication methods. Herein, we report a preliminary study on using a laser-based method (i.e., matrix-assisted pulsed laser evaporation, or MAPLE) for obtaining active polymeric⁻enzymatic interfaces as hybrid or layered coatings for detecting toxic vapors. The MAPLE fabrication consisted of the simultaneous alternating evaporation of layers of polyethylenimine (PEI) and acetylcholinesterase (AchE) in order to obtain active surfaces as both hybrid PEI-AchE and a PEI/AchE layered coating, respectively. The deposition processes of the polymer and enzyme were carried out using a double-target system and a Nd:YAG pulsed laser, operating at 0.45 J/cm² fluences with a wavelength of 266 nm and a repetition rate of 10 Hz. Fourier transform infrared spectroscopy revealed no significant changes in the functional groups of both hybrid and layered coatings compared with the initial material. The thickness and roughness, as well as the morphologies of the coatings revealed by atomic force microscopy and scanning electron microscopy showed coatings thicker than two µm that had smooth surfaces and average roughness values below six nm. The sensors were tested with simulants for nerve gases and pesticides containing phosphonate ester groups, namely dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP), and a different sensitivity was shown to the selected chemical agents for each of the sensors. The best sensitivities for DMMP and DIMP obtained by using a PEI-AchE coated sensor are 65 kHz and 200 kHz, respectively, whereas the best sensitivity when using multilayered interfaces is 30 kHz and 10 KHz for DIMP and DMMP, respectively.


Asunto(s)
Acetilcolinesterasa/química , Técnicas Biosensibles , Gases/aislamiento & purificación , Polietileneimina/química , Gases/toxicidad , Compuestos Organofosforados/química , Pirazinas/química
11.
Micromachines (Basel) ; 9(8)2018 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-30424331

RESUMEN

A device to monitor particulate matter of size 2.5 µm (PM2.5) that has been designed and developed includes a surface-acoustic-wave sensor operating in a shear horizontal mode (SH-SAW) combined with a cyclone separator. In our tests, aerosols generated as incense smoke were first separated and sampled inside a designed cyclone separator; the sampled PM2.5 was then introduced into the sensing area of an SH-SAW sensor for detection. The use of microcentrifuge tubes as a cyclone separator effectively decreases the size and power consumption of the device; the SAW sensor in a well design and operating at 122 MHz was fabricated with MEMS techniques. After an explanation of the design of the cyclone separator, a simulation of the efficiency and the SAW sensor detection are discussed. A microcentrifuge tube (volume 0.2 mL, inlet and outlet diameters 0.5 mm) as a separator has separation cutoff diameters 50% (d50) at 2.5 µm; the required rate of volumetric flow at the inlet is 0.125 LPM, according to simulation with computational fluid dynamics (CFD) software; the surface-acoustic-wave (SAW) sensor exhibits sensitivity approximately 9 Hz/ng; an experiment for PM2.5 detection conducted with the combined device shows a strong positive linear correlation with a commercial aerosol monitor. The limit of detection (LOD) is 11 µg/m³ with sample time 160 s and total detection duration about 5 min.

12.
Phytochem Anal ; 29(3): 275-283, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29280218

RESUMEN

INTRODUCTION: Aroma is important in night-flowering species, as visually they can not be observed well. Thus, the analysis of the volatiles of evening-primrose is of great interest in biological fields and therapy. Furthermore, the analysis of volatiles demands rapid and simple procedure, because volatiles decompose. OBJECTIVE: The aim of this study is to show the rapid monitoring of the volatiles of evening-primrose according to the flowering or closing by fast gas chromatography/surface acoustic wave GC/SAW. Moreover, calibration according to the sensor temperature of the GC/SAW was performed, achieving a high reproducibility and excellent sensitivity. METHODOLOGY: GC/SAW is an effective analytical method that provides on-line measurements without pretreatment of sample. Headspace solid-phase micro-extraction coupled to gas chromatography mass spectrometry (HS-SPME-GC-MS) and dynamic headspace trapping and extraction with GC-MS were employed to confirm the identification of the volatiles of evening-primrose compared to GC/SAW. RESULTS: Linalool was found to be the dominant component, comprising 96.4-25.2% of the total amount, according to the opening or closing. Interestingly, the amount of indole also varied according to the opening or closing (3.0-0.0%) such as linalool. Also, while the sensitivity increased with the reduction in the sensor temperature of the GC/SAW, the reproducibility showed a tendency to decrease. CONCLUSION: The results showed that flower opening is related to the volatiles emission, which is pharmacological and plant defensive. GC/SAW can be a useful analytical method for the rapid monitoring of volatiles of evening-primrose according to the opening or closing as it provides second unit analysis, as well as simple, and aroma pattern recognition. Copyright © 2017 John Wiley & Sons, Ltd.


Asunto(s)
Acústica , Flores/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Odorantes , Oenothera biennis/química , Compuestos Orgánicos Volátiles/análisis , Monoterpenos Acíclicos , Calibración , Límite de Detección , Monoterpenos/análisis , Estándares de Referencia , Reproducibilidad de los Resultados , Microextracción en Fase Sólida
13.
Technol Health Care ; 25(S1): 435-441, 2017 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-28582931

RESUMEN

BACKGROUND: Intracranial pressure (ICP) monitoring is very important for assessing and monitoring hydrocephalus, head trauma and hypertension patients, which could lead to elevated ICP or even devastating neurological damage. The mortality rate due to these diseases could be reduced through ICP monitoring, because precautions can be taken against the brain damage. OBJECTIVE: This paper presents a surface acoustic wave (SAW) pressure sensor to realize ICP monitoring, which is capable of wireless and passive transmission with antenna attached. METHODS: In order to improve the temperature stability of the sensor, two methods were adopted. First, the ST cut quartz was chosen as the sensor substrate due to its good temperature stability. Then, a differential temperature compensation method was proposed to reduce the effects of temperature. Two resonators were designed based on coupling of mode (COM) theory and the prototype was fabricated and verified using a system established for testing pressure and temperature. RESULTS: The experiment result shows that the sensor has a linearity of 2.63% and hysteresis of 1.77%. CONCLUSIONS: The temperature stability of the sensor has been greatly improved by using the differential compensation method, which validates the effectiveness of the proposed method.


Asunto(s)
Presión Intracraneal , Monitoreo Fisiológico/métodos , Transductores de Presión , Humanos , Modelos Estadísticos , Monitoreo Fisiológico/instrumentación , Tecnología de Sensores Remotos/instrumentación , Tecnología de Sensores Remotos/métodos , Sonido , Temperatura , Tecnología Inalámbrica/instrumentación
14.
Sensors (Basel) ; 16(11)2016 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-27792131

RESUMEN

An electronic nose (E-Nose) is one of the applications for surface acoustic wave (SAW) sensors. In this paper, we present a low-noise complementary metal-oxide-semiconductor (CMOS) readout application-specific integrated circuit (ASIC) based on an SAW sensor array for achieving a miniature E-Nose. The center frequency of the SAW sensors was measured to be approximately 114 MHz. Because of interference between the sensors, we designed a low-noise CMOS frequency readout circuit to enable the SAW sensor to obtain frequency variation. The proposed circuit was fabricated in Taiwan Semiconductor Manufacturing Company (TSMC) 0.18 µm 1P6M CMOS process technology. The total chip size was nearly 1203 × 1203 µm². The chip was operated at a supply voltage of 1 V for a digital circuit and 1.8 V for an analog circuit. The least measurable difference between frequencies was 4 Hz. The detection limit of the system, when estimated using methanol and ethanol, was 0.1 ppm. Their linearity was in the range of 0.1 to 26,000 ppm. The power consumption levels of the analog and digital circuits were 1.742 mW and 761 µW, respectively.

15.
Molecules ; 20(6): 10298-312, 2015 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-26046325

RESUMEN

Fast gas chromatography-surface acoustic wave sensor (GC/SAW) has been applied for the detection of the pharmacological volatiles emanated from Houttuynia cordata Thunb which is from South Korea. H. cordata Thunb with unpleasant and fishy odors shows a variety of pharmacological activities such as anti-microbial, anti-inflammatory, anti-cancer, and insect repellent. The aim of this study is to show a novel quality control by GC/SAW methodology for the discrimination of the three different parts of the plant such as leaves, aerial stems, and underground stems for H. cordata Thunb. Sixteen compounds were identified. ß-Myrcene, cis-ocimene and decanal are the dominant volatiles for leaves (71.0%) and aerial stems (50.1%). While, monoterpenes (74.6%) are the dominant volatiles for underground stems. 2-Undecanone (1.3%) and lauraldehyde (3.5%) were found to be the characteristic components for leaves. Each part of the plant has its own characteristic fragrance pattern owing to its individual chemical compositions. Moreover, its individual characteristic fragrance patterns are conducive to discrimination of the three different parts of the plant. Consequently, fast GC/SAW can be a useful analytical method for quality control of the different parts of the plant with pharmacological volatiles as it provides second unit analysis, a simple and fragrant pattern recognition.


Asunto(s)
Cromatografía de Gases/instrumentación , Houttuynia/química , Odorantes/análisis , Hojas de la Planta/química , Tallos de la Planta/química , Compuestos Orgánicos Volátiles/aislamiento & purificación , Monoterpenos Acíclicos , Aldehídos/aislamiento & purificación , Alquenos/aislamiento & purificación , Cromatografía de Gases/métodos , Medicamentos Herbarios Chinos/química , Cetonas/aislamiento & purificación , Monoterpenos/aislamiento & purificación , Control de Calidad , Sonido
16.
Br J Anaesth ; 113(5): 807-14, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25012583

RESUMEN

BACKGROUND: Although pilot studies have reported that exhaled propofol concentrations can reflect intraoperative plasma propofol concentrations in an individual, the blood/exhaled partial pressure ratio RBE varies between patients, and the relevant factors have not yet been clearly addressed. No efficient method has been reported for the quick evaluation of RBE and its association with inter-individual variables. METHODS: We proposed a novel method that uses a surface acoustic wave (SAW) sensor combined with a fast gas chromatograph (GC) to simultaneously detect propofol concentrations in blood and exhaled gas in 28 patients who were receiving propofol i.v. A two-compartment pharmacokinetic (PK) model was established to simulate propofol concentrations in exhaled gas and blood after a bolus injection. Simulated propofol concentrations for exhaled gas and blood were used in a linear regression model to evaluate RBE. RESULTS: The fast GC-SAW system showed reliability and efficiency for simultaneous quantitative determination of propofol in blood (correlation coefficient R(2)=0.994, P<0.01) and exhaled gas (R(2)=0.991, P<0.01). The evaluation of RBE takes <50 min for a patient. The distribution of RBE in 28 patients showed inter-individual differences in RBE (median 1.27; inter-quartile range 1.07-1.59). CONCLUSIONS: Fast GC-SAW, which analyses samples in seconds, can perform both rapid monitoring of exhaled propofol concentrations and fast analysis of blood propofol concentrations. The proposed method allows early determination of the coefficient RBE in individuals. Further studies are required to quantify the distribution of RBE in a larger cohort and assess the effect of other potential factors. CLINICAL TRIAL REGISTRATION: ChiCTR-ONC-13003291.


Asunto(s)
Anestésicos Intravenosos/análisis , Anestésicos Intravenosos/farmacocinética , Cromatografía de Gases/métodos , Propofol/análisis , Propofol/farmacocinética , Adulto , Anciano , Algoritmos , Anestésicos Intravenosos/sangre , Pruebas Respiratorias , Calibración , Cromatografía de Gases/instrumentación , Femenino , Gases/análisis , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Propofol/sangre , Reproducibilidad de los Resultados
17.
Meat Sci ; 95(3): 699-703, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23601789

RESUMEN

Aim of the study was the application of biosensor technique to measure the concentration of an acute phase protein (APP) within complex matrices from animal origin. For the first time, acute phase protein haptoglobin (Hp) was detected from unpurified meat juice of slaughter pigs by a label-free biosensor-system, the SAW-based sam®5 system. The system uses a sensor chip with specific antibodies to catch Hp while the mass-related phase shift is measured. The concentration is calculated as a function of these measured phase shifts. The results correlate very well with reference measurement results obtained by enzyme-linked immunosorbent assay (ELISA), R=0.98. The robust setup of the surface acoustic wave (SAW)-based system and its ability to measure within very short time periods qualifies it for large-scale analyses and is apt to identify rapidly pigs in the meat production process whose consumption would have an increased risk for consumers.


Asunto(s)
Acústica , Técnicas Biosensibles/métodos , Inocuidad de los Alimentos/métodos , Haptoglobinas/análisis , Carne/análisis , Mataderos , Animales , Anticuerpos , Ensayo de Inmunoadsorción Enzimática , Carne/normas , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA