Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dent Mater ; 40(4): 756-763, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38429216

RESUMEN

OBJECTIVE: To evaluate the influence of printing orientation on flexural strength (σf) and elastic modulus (E) of different 3D printing dental restorative resins. METHODS: Bar-shaped specimens (n = 20) were fabricated from two SLA-printed resins (FT- Formlabs Temporary, and FP- Formlabs Permanent) and two DLP-printed resins (DFT- Detax Freeprint Temp, and GCT- GC Temporary) using two building orientations (0º and 90º). The 3D-printed structures were aged (14 d) before submitted to three-point bending in 37ºC distilled water at a crosshead speed of 1.0 ± 0.3 mm/min until fracture to calculate the σf and the E values. The fractured surfaces were evaluated using stereomicroscopy and scanning electron microscopy (SEM) following fractography principles. Data were statistically analyzed using two-way ANOVA and Tukey post-hoc (α = 0.001). RESULTS: FP and FT showed significantly higher E values than DFT and GCT, irrespectively of printing orientation (p < 0.001). There was no statistical difference between the building orientations (0º and 90º) for the mean σf and E values for the resin materials evaluated. Fractographic characteristics were similar for the surface fracture from all the materials evaluated, showing typical brittle fracture behavior. SIGNIFICANCE: Printing orientation did not influence of flexural strength and elastic modulus values for the 3D-printed resin structures evaluated. Surface topography was mostly governed by the 3D printer type.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Materiales Dentales/química , Resinas Compuestas/química , Ensayo de Materiales , Resistencia Flexional , Impresión Tridimensional , Propiedades de Superficie
2.
J Dent ; 144: 104942, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38494044

RESUMEN

OBJECTIVES: This study endeavours to investigate the effect of printing orientation on the trueness of additively manufactured molar zirconia crowns. The areal surface roughness and the characteristics of the marginal regions of the crowns were also considered. METHODS: Twelve molar crowns were manufactured at 0°, 45°, and, 90° printing orientations in a Lithoz and AON zirconia printer, respectively. Twelve milled crowns were used as a comparison. Samples were scanned and analysed in metrology software to determine the trueness of the groups. Regions of interest were defined as the margins, intaglio surface and contact points. Areal surface roughness and print layer thickness were further analysed using a confocal laser scanning microscope. RESULTS: The results indicate that there are clear differences between the investigated desktop (AON) and industrial (Lithoz) 3D printer. The 45° Lithoz group is the only sample group showing no significantly different results in trueness for all regions analysed compared to the milled group. Areal surface roughness analysis indicates that the print layers in the marginal regions are within clinically tolerable limits and surface characteristics. CONCLUSIONS: The printing orientation for zirconia crowns is critical to trueness, and differences are evident between different AM apparatuses. Considerations for design and orientation between different apparatuses should therefore be considered when utilising direct additive manufacturing processes. The areal surface roughness of the marginal regions is within acceptable clinical limits for all manufacturing processes and print orientations considered. CLINICAL SIGNIFICANCE: The materials and apparatuses for additive manufacturing of zirconia crowns are now clinically acceptable from the perspective of the trueness of a final crown for critical functional surfaces and areal surface roughness of the marginal regions.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Impresión Tridimensional , Propiedades de Superficie , Circonio , Circonio/química , Humanos , Materiales Dentales/química , Microscopía Confocal , Diente Molar , Ensayo de Materiales , Adaptación Marginal Dental
3.
J Mech Behav Biomed Mater ; 152: 106458, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38364445

RESUMEN

OBJECTIVES: To investigate the influence of material and printing orientation on wear resistance and flexural properties of one low force SLA- and two DLP-printed splint materials and to compare these 3D-printed splints to a subtractively manufactured splint material. METHODS: Two DLP-printed (V-Print splint, LuxaPrint Ortho Plus) and one low force SLA-printed (Dental LT Clear) material, where specimens were printed in three printing orientations (0°, 45°, 90°), were investigated. In addition, one milled splint material (Zirlux Splint Transparent) was examined. A total of 160 specimens were produced for both test series. The two-body wear test was performed in a chewing simulator (80'000 cycles at 50 N with 5-55 °C thermocycling). Steatite balls were used as antagonists. The wear pattern was analyzed with a 3D digital microscope in terms of maximum vertical intrusion depth (mm) and total volume loss (mm³). The flexural properties were investigated by three-point bending in accordance with ISO 20795-1: 2013 (denture base polymers). The flexural strength (MPa) and the flexural modulus (MPa) were measured. Two-way ANOVA was performed to investigate the effects of the two independent variables material and printing orientation for the three 3D-printed materials. The comparison of the printing orientations within one material was carried out with one-way ANOVA with post-hoc Tukey tests. RESULTS: Two-way ANOVA revealed that wear and flexural properties are highly dependent on the 3D-printed material (p < 0.001). Across groups, a significant effect was observed for wear depth (p = 0.031) and wear volume (p = 0.044) with regard to printing orientation but this was not found for flexural strength (p = 0.080) and flexural modulus (p = 0.136). One-way ANOVA showed that both DLP-printed groups showed no significant differences within the printing orientations in terms of wear and flexural properties. Dental LT Clear showed that 90° oriented specimens had higher flexural strength than 0° oriented ones (p < 0.001) and 45° oriented specimens also showed higher values than 0° ones (p = 0.038). No significant differences were observed within the printing orientations for flexural modulus and wear behaviour within this group. T-tests showed that the milled splints exhibited statistically higher wear resistance and flexural properties compared to all three 3D-printed splint materials (p < 0.001) and that highly significant differences were found between the 3D-printed splint materials for both test series. CONCLUSION: Within the limitations of this in vitro study, it can be stated that wear behaviour and flexural properties are highly dependent on the 3D-printed material itself. Currently, milled splints exhibit higher wear resistance and flexural properties compared to 3D-printed splint materials. The printing orientation has a minor influence on the properties investigated. Nevertheless, two-way ANOVA also showed a significant influence of printing orientation in the wear test across groups and one-way ANOVA detected significant effects for SLA material in terms of flexural strength, with printing in 90° showing the highest flexural strength. Therefore, anisotropy was found in SLA material, but it can be limited with the employed printing parameters. Both DLP-printed materials showed no significant difference within the printing orientation.


Asunto(s)
Resistencia Flexional , Gastrópodos , Animales , Férulas (Fijadores) , Análisis de Varianza , Anisotropía , Impresión Tridimensional
4.
Dent Mater ; 39(10): 894-902, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37598040

RESUMEN

OBJECTIVES: To evaluate the influence of thickness and printing angle on the optical properties of 3D-printed dental restorative resins. METHODS: Four 3D printing resin systems were evaluated: DFT-Detax Freeprint Temp; FP- Formlabs Permanent Crown; FP- Formlabs Temporary CB; and GCT- GC Temporary-. Samples from each material were printed at 0° and 90°, and polished up to 0.5, 1.0, 1.5 and 2.0 mm thickness. Scattering (S), absorption (K) and albedo (a) coefficients, transmittance (T%), light reflectivity (RI) and infinite optical thickness (X∞) were calculated using Kubelka-Munk's model. Data were statistically analyzed using Kruskal-Wallis¸ Mann-Whitney tests, and VAF coefficient. RESULTS: The spectral distribution on S, K, T%, RI,X∞ were wavelength dependent. Although the spectral behaviors were similar for all the specimens evaluated, the values of S, K, T% andX∞ presented significant differences between specimen thicknesses for all the materials used and for both printing orientations. Values for S and K increased, and T% and X∞ decreased. Significant differences between 0° and 90° were found for RI values at 0.5 and 1.0 mm thick samples, for S and K at 2.0 mm, for X∞ at 0.5 and 1.0 mm for DFT, and at 0.5 mm for FT. CONCLUSIONS: Optical properties of 3D-printed restorative resins vary between thicknesses, and could be affected by the building orientation. Therefore, these factors should be considered in order to improve the biomimetic potential of 3D-printed dental restorative resins. CLINICAL SIGNIFICANCE: Understanding the optical behavior of the 3D-printed restorative resins is essential to optimize their clinical performance.


Asunto(s)
Diente , Impresión Tridimensional , Coronas , Ensayo de Materiales , Resinas Compuestas
5.
Polymers (Basel) ; 15(7)2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37050351

RESUMEN

The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended.

6.
Materials (Basel) ; 15(23)2022 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-36499877

RESUMEN

In this study, we propose to revisit the mechanical anisotropy inferred to printed ABS polymers using fused deposition modelling by combining digital image correlation (DIC), mechanical testing and finite element computation. Tensile specimens are printed using different design orientations and raster angles. Monitoring of deformed samples is performed, and strain fields are derived for each configuration. Finite element modelling of the 3D-printed material behaviour is considered to shed more light on deformation mechanisms. Experimental results show that a heterogeneous strain field develops, leading to more significant strain localisation for samples printed with the main dimension aligned with the building direction. The optimal printing angle allowing the filament to be crossed at -45°/+45° shows the best behaviour with even larger elongation at break compared to the raw material. However, digital image correlation based on optical imaging shows that a limiting scale exists for revealing the effect of filament orientation on strain localisation. Finite element results reveal the nature of the strain localisation as related presence of porosity close to the frame and the development of asymmetrical filling within the printed structure.

7.
Materials (Basel) ; 15(19)2022 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-36234084

RESUMEN

The mechanical properties of resin samples in low-force stereolithography additive manufacturing were affected by the printing orientation, and were investigated and optimized to achieve excellent single or comprehensive tensile strength, compressive strength, and flexural modulus. The resin samples were fabricated using a Form3 3D printer based on light curing technology according to the corresponding national standards, and they were detected using a universal testing machine to test their mechanical properties. The influence of the printing orientation was represented by the rotation angle of the resin samples relative to the x-axis, y-axis and z-axis, and the parameters was selected in the range 0°-90° with an interval of 30°. The multiple regression models for the mechanical properties of the prepared resin samples were obtained based on least square estimation, which offered a foundation from which to optimize the parameters of the printing orientation by cuckoo search algorithm. The optimal parameters for the tensile strength, compressive strength and flexural modulus were 'α = 45°, ß = 25°, γ = 90°', 'ß = 0°, ß = 51°, γ = 85°' and 'α = 26°, ß = 0°, γ = 90°', respectively, which obtained the improvements of 80.52%, 15.94%, and 48.85%, respectively, relative to the worst conditions. The mechanism was qualitatively discussed based on the force analysis. The achievements obtained in this study proved that optimization of the printing orientation could improve the mechanical properties of the fabricated sample, which provided a reference for all additive manufacturing methods.

8.
Micromachines (Basel) ; 13(8)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-36014119

RESUMEN

We present a low-cost and simple method to fabricate a novel lock-and-key mixer microfluidics using an economic stereolithography (SLA) three-dimensional (3D) printer, which costs less than USD 400 for the investment. The proposed study is promising for a high throughput fabrication module, typically limited by conventional microfluidics fabrications, such as photolithography and polymer-casting methods. We demonstrate the novel modular lock-and-key mixer for the connector and its chamber modules with optimized parameters, such as exposure condition and printing orientation. In addition, the optimization of post-processing was performed to investigate the reliability of the fabricated hollow structures, which are fundamental to creating a fluidic channel or chamber. We found out that by using an inexpensive 3D printer, the fabricated resolution can be pushed down to 850 µm and 550 µm size for squared- and circled-shapes, respectively, by the gradual hollow structure, applying vertical printing orientation. These strategies opened up the possibility of developing straightforward microfluidics platforms that could replace conventional microfluidics mold fabrication methods, such as photolithography and milling, which are costly and time consuming. Considerably cheap commercial resin and its tiny volume employed for a single printing procedure significantly cut down the estimated fabrication cost to less than 50 cents USD/module. The simulation study unravels the prominent properties of the fabricated devices for biological fluid mixers, such as PBS, urine and plasma blood. This study is eminently prospective toward microfluidics application in clinical biosensing, where disposable, low-cost, high-throughput, and reproducible chips are highly required.

9.
Polymers (Basel) ; 14(12)2022 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-35746062

RESUMEN

An experimental investigation was performed to understand the quasi-static shear response of additively manufactured (AM) acrylonitrile butadiene styrene (ABS) via fusion deposition modeling (FDM). A modified flat hat-shaped (FHS) specimen configuration was used for shear testing. The main aim of this study was to investigate the effect of four different shear angles (0°, 5.44°, 13.39°, and 20.83°) and three printing orientations (vertical build, 0°/90°, and 45°/-45°) on the shear constitutive response and shear performance of FDM-printed ABS. Scanning electron microscopy images of the failure surface were used to explain the shear response of the material. The flow shear stress of the shear stress-strain response for vertically printed specimens demonstrated a monotonic increase up to a peak shear stress and then decrease at the end of the shear zone, while for 0°/90° specimens, an increasing trend until the peak value at the end of the shear zone was observed. With increasing shear angles, all specimens printed with three printing orientations exhibited increasing shear zone size and shear strength, and the 0°/90° specimens exhibited the highest shear strength for all four shear angles. However, the specimens of the 45°/-45° orientation demonstrated the highest increase in shear strength by about 60% and in the shear strain at the end of shear zone by about 175% as the shear angle was increased from 0° to 20.83°.

10.
J Dent ; 124: 104155, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526752

RESUMEN

OBJECTIVES: To evaluate the effect of printing orientation on the fracture strength of 3-unit interim fixed dental prostheses fabricated by using additive manufacturing and to compare with those fabricated by subtractive manufacturing after thermomechanical aging. MATERIALS AND METHODS: A 3-unit fixed dental prosthesis was designed by using a dental design software (exocad DentalCAD 2.2 Valetta) in standard tessellation language (STL) format. This STL file was exported into a nesting software (PreForm) and 3-unit interim fixed dental prostheses with 5 different orientations (0°, 30°, 45°, 90°, and 150°) were printed by using a 3-dimensional (3D) printing interim resin (Temporary CB) (n = 10). The same STL file was also used to mill polymethymethacrylate (DuoCAD) 3-unit interim fixed dental prostheses as the control group (n = 10). All specimens were cemented onto cobalt-chromium test models representing a maxillary first premolar and first molar tooth with a long-term temporary cement (DentoTemp), and subjected to thermomechanical aging (120,000 cycles, 1.6 Hz, 50 N, 5-55 °C). Then, all specimens were loaded until fracture by using a universal tester. The data were analyzed with nonparametric 1-way analysis of variance (Kruskal-Wallis) and Dunn's tests (α = 0.05). RESULTS: Additively manufactured specimens printed with 90° showed the lowest fracture strength values (P≤.048). However, the difference between specimens printed with 45° and 90° was nonsignificant (P>.05). Milled 3-unit interim fixed dental prostheses withstood significantly higher loads than 3-unit interim fixed dental prostheses printed with 45° and 150° (P≤.012). In addition, specimens printed with 0° showed higher fracture strength than the specimens printed with 45° (P=.01). Specimens printed with 0° and 30° presented similar fracture strength values with milled (P≥.057) and 150° printed (P>.05) specimens. CONCLUSIONS: Printing orientation had a significant effect on the fracture strength of 3-unit interim fixed dental prostheses. Among the additively manufactured samples, those printed with 0° showed similar fracture strength values with the subtractively manufactured samples. CLINICAL SIGNIFICANCE: Three-unit interim fixed dental prostheses fabricated with 0° and 30° using the 3D printing interim resin tested may be alternatives to milled PMMA in terms of fracture strength.


Asunto(s)
Prótesis Dental , Resistencia Flexional , Diseño Asistido por Computadora , Análisis del Estrés Dental , Ensayo de Materiales , Impresión Tridimensional
11.
J Clin Med ; 10(9)2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-34066993

RESUMEN

OBJECTIVE: A digital workflow opens up new possibilities for the indirect bonding (IDB) of brackets. We tested if the printing orientation for bracket transfer models on the build platform of a 3D printer influences the accuracy of the following IDB method. We also evaluated the clinical acceptability of the IDB method combining digitally planned and printed transfer models with the conventional fabrication of pressure-molded transfer trays. MATERIALS AND METHODS: In total, 27 digitally planned bracket transfer models were printed with both 15° and 75° angulation from horizontal plane on the build platform of a digital light processing (DLP) printer. Brackets were temporarily bonded to the transfer models and pressure-molded trays were produced on them. IDB was then performed using the trays on the respective plaster models. The plaster models were scanned with an optical scanner. Digitally planned pre-bonding and scanned post-bonding bracket positions were superimposed with a software and resulted in three linear and three angular deviations per bracket. RESULTS: No statistically significant differences of the transfer accuracy of printed transfer models angulated 15° or 75° on the 3D printer build platform were found. About 97% of the linear and 82% of the angular deviations were within the clinically acceptable range of ±0.2 mm and ±1°, respectively. The highest inaccuracies in the linear dimension occurred in the vertical towards the gingival direction and in the angular dimension in palatal crown torque. CONCLUSION: For the IDB method used, the printing orientation on the build platform did not have a significant impact on the transfer accuracy.

12.
Materials (Basel) ; 14(2)2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33430271

RESUMEN

Computer-aided design and computer-aided manufacturing (CAD-CAM) enable subtractive or additive fabrication of temporary fixed dental prostheses (FDPs). The present in-vitro study aimed to compare the fracture resistance of both milled and additive manufactured three-unit FDPs and bar-shaped, ISO-conform specimens. Polymethylmethacrylate was used for subtractive manufacturing and a light-curing resin for additive manufacturing. Three (bars) and four (FDPs) different printing orientations were evaluated. All bars (n = 32) were subjected to a three-point bending test after 24 h of water storage. Half of the 80 FDPs were dynamically loaded (250,000 cycles, 98 N) with simultaneous hydrothermal cycling. Non-aged (n = 40) and surviving FDPs (n = 11) were subjected to static loading until fracture. Regarding the bar-shaped specimens, the milled group showed the highest flexural strength (114 ± 10 MPa, p = 0.001), followed by the vertically printed group (97 ± 10 MPa, p < 0.007). Subtractive manufactured FDPs revealed the highest fracture strength (1060 ± 89 N) with all specimens surviving dynamic loading. During artificial aging, 29 of 32 printed specimens failed. The present findings indicate that both printing orientation and aging affect the strength of additive manufactured specimens. The used resin and settings cannot be recommended for additive manufacturing of long-term temporary three-unit FDPs.

13.
Materials (Basel) ; 11(8)2018 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-30126216

RESUMEN

The aim of this paper is to explore the watertightness behaviour for high pressure applications using Multi Jet Fusion technology and polyamide 12 as a material. We report an efficient solution for manufacturing functional prototypes and final parts for water pressure applications and provide manufacturing rules for engineers in the pressurized product development process for up to 10 MPa of nominal pressure. The research findings show manufacturers the possibility of using additive manufacturing as an alternative to traditional manufacturing. Water leakage was studied using different printing orientations and wall thicknesses for a range of pressure values. An industrial ball valve was printed and validated with the ISO 9393 standard as also meeting tolerance requirements. This paper is a pioneering approach to the additive manufacturing of high-performance fluid handling components. This approach solves the problem of leakage caused by porosity in additive manufacturing technologies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA