Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros











Intervalo de año de publicación
1.
Sensors (Basel) ; 23(23)2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38067804

RESUMEN

For space-based gravitational wave detection, a laser interferometric measurement system composed of a three-spacecraft formation offers the most rewarding bandwidth of astrophysical sources. There are no oscillators available that are stable enough so that each spacecraft could use its own reference frequency. The conversion between reference frequencies and their distribution between all spacecrafts for the synchronization of the different metrology systems is the job of the inter-spacecraft frequency setting strategy, which is important for continuously acquiring scientific data and suppressing measurement noise. We propose a hierarchical optimization algorithm to solve the frequency setting strategy. The optimization objectives are minimum total readout displacement noise and maximum beat-note frequency feasible range. Multiple feasible parameter combinations were obtained for the Taiji program. These optimized parameters include lower and upper bounds of the beat note, sampling frequency, pilot tone signal frequency, ultrastable clock frequencies, and modulation depth. Among the 20 Pareto optimal solutions, the minimum total readout displacement noise was 4.12 pm/Hz, and the maximum feasible beat-note frequency range was 23 MHz. By adjusting the upper bound of beat-note frequency and laser power transmitted by the telescope, we explored the effects of these parameters on the minimum total readout displacement noise and optimal local laser power in greater depth. Our results may serve as a reference for the optimal design of laser interferometry system instrument parameters and may ultimately improve the detection performance and continuous detection time of the Taiji program.

2.
Sensors (Basel) ; 23(24)2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38139604

RESUMEN

Future GRACE-like geodesy missions could benefit from adopting accelerometer technology akin to that of the LISA Pathfinder, which employed laser interferometric readout at the sub-picometer level in addition to the conventional capacitive sensing, which is at best at the level of 100 pm. Improving accelerometer performance holds great potential to enhance the scientific output of forthcoming missions, carrying invaluable implications for research in climate, water resource management, and disaster risk reduction. To reach sub-picometer displacement sensing precision in the millihertz range, laser interferometers rely on suppression of laser-frequency noise by several orders of magnitude. Many optical frequency stabilization methods are available with varying levels of complexity, size, and performance. In this paper, we describe the performance of a Mach-Zehnder interferometer based on a compact monolithic optic. The setup consists of a commercial fiber injector, a custom-designed pentaprism used to split and recombine the laser beam, and two photoreceivers placed at the complementary output ports of the interferometer. The structural stability of the prism is transferred to the laser frequency via amplification, integration, and feedback of the balanced-detection signal, achieving a fractional frequency instability better than 6 parts in 1013, corresponding to an interferometer pathlength stability better than 1pm/Hz. The prism was designed to host a second interferometer to interrogate the position of a test mass. This optical scheme has been dubbed "single-element dual-interferometer" or SEDI.

3.
Sensors (Basel) ; 23(18)2023 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-37765998

RESUMEN

Optical coherent detection is widely used for highly sensitive sensing applications, but nonlinearity issues pose challenges in accurately interpreting the system outputs. Most existing compensation methods require access to raw measurement data, making them not useful when only demodulated data are available. In this study, we propose a compensation method designed for direct application to demodulated data, effectively addressing the 1st and 2nd-order nonlinearities in both homodyne and heterodyne systems. The approach involves segmenting the distorted signal, fitting and removing baselines in each section, and averaging the resulting distortions to obtain precise distortion shapes. These shapes are then used to retrieve compensation parameters. Simulation shows that the proposed method can effectively reduce the deviation caused by the nonlinearities without using the raw data. Experimental results from a silicon-photonics-based homodyne laser Doppler vibrometry prove that this method has a similar performance as the conventional Heydemann correction method.

4.
Int J Mol Sci ; 24(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37175771

RESUMEN

The weak point of ionic liquids is their high viscosity, limiting the maximum polymer concentration in the forming solutions. A low-viscous co-solvent can reduce viscosity, but cellulose has none. This study demonstrates that dimethyl sulfoxide (DMSO), being non-solvent for cellulose, can act as a nominal co-solvent to improve its processing into a nanofiltration membrane by phase inversion. A study of the rheology of cellulose solutions in diluted ionic liquids ([EMIM]Ac, [EMIM]Cl, and [BMIM]Ac) containing up to 75% DMSO showed the possibility of decreasing the viscosity by up to 50 times while keeping the same cellulose concentration. Surprisingly, typical cellulose non-solvents (water, methanol, ethanol, and isopropanol) behave similarly, reducing the viscosity at low doses but causing structuring of the cellulose solution and its phase separation at high concentrations. According to laser interferometry, the nature of these non-solvents affects the mass transfer direction relative to the forming membrane and the substance interdiffusion rate, which increases by four-fold when passing from isopropanol to methanol or water. Examination of the nanofiltration characteristics of the obtained membranes showed that the dilution of ionic liquid enhances the rejection without changing the permeability, while the transition to alcohols increases the permeability while maintaining the rejection.


Asunto(s)
Líquidos Iónicos , Solventes , Celulosa , Dimetilsulfóxido , 2-Propanol , Metanol , Agua , Reología , Viscosidad
5.
Photoacoustics ; 28: 100391, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36042699

RESUMEN

A high-sensitivity all-optical photoacoustic spectroscopy based on fast swept laser interferometry is proposed to trace gas detection. The momentary cavity length of the fiber-optic Fabry-Perot microphone is demodulated by a fast swept-laser interferometry with an instantaneous frequency demodulation algorithm. The all-optical photoacoustic spectroscopy based on the designed microphone was tested for trace acetylene gas detection in the near-infrared region. The normalized noise equivalent absorption coefficient for acetylene gas is achieved to be 1.06 × 10-9 cm-1 W Hz-1∕2.

6.
Micromachines (Basel) ; 13(4)2022 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-35457885

RESUMEN

Accurate and efficient measurements of the piezoelectric properties of AlN and AlScN films are very important for the design and simulation of micro-electro-mechanical system (MEMS) sensors and actuator devices. In this study, a process control monitor (PCM) structure compatible with the device manufacturing process is designed to achieve accurate determination of the piezoelectric coefficients of MEMS devices. Double-beam laser interferometry (DBLI) and laser Doppler vibrometry (LDV) measurements are applied and combined with finite element method (FEM) simulations, and values of the piezoelectric parameters d33 and d31 are simultaneously extracted. The accuracy of d31 is verified directly by using a cantilever structure, and the accuracy of d33 is verified by in situ synchrotron radiation X-ray diffraction; the comparisons confirm the viability of the results obtained by the novel combination of LDV, DBLI and FEM techniques in this study.

7.
Sensors (Basel) ; 22(5)2022 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-35271216

RESUMEN

The laser ranging interferometer onboard the Gravity Recovery and Climate Experiment Follow-On mission proved the feasibility of an interferometric sensor for inter-satellite length tracking with sub-nanometer precision, establishing an important milestone for space laser interferometry and the general expectation that future gravity missions will employ heterodyne laser interferometry for satellite-to-satellite ranging. In this paper, we present the design of an on-axis optical bench for next-generation laser ranging which enhances the received optical power and the transmit beam divergence, enabling longer interferometer arms and relaxing the optical power requirement of the laser assembly. All design functionalities and requirements are verified by means of computer simulations. A thermal analysis is carried out to investigate the robustness of the proposed optical bench to the temperature fluctuations found in orbit.

8.
Int J Mol Sci ; 23(3)2022 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-35163794

RESUMEN

The search for new microbicide compounds is of an urgent need, especially against difficult-to-eradicate biofilm-forming bacteria. One attractive option is the application of cationic multivalent dendrimers as antibacterials and also as carriers of active molecules. These compounds require an adequate hydrophilic/hydrophobic structural balance to maximize the effect. Herein, we evaluated the antimicrobial activity of cationic carbosilane (CBS) dendrimers unmodified or modified with polyethylene glycol (PEG) units, against planktonic and biofilm-forming P. aeruginosa culture. Our study revealed that the presence of PEG destabilized the hydrophilic/hydrophobic balance but reduced the antibacterial activity measured by microbiological cultivation methods, laser interferometry and fluorescence microscopy. On the other hand, the activity can be improved by the combination of the CBS dendrimers with endolysin, a bacteriophage-encoded peptidoglycan hydrolase. This enzyme applied in the absence of the cationic CBS dendrimers is ineffective against Gram-negative bacteria because of the protective outer membrane shield. However, the endolysin-CBS dendrimer mixture enables the penetration through the membrane and then deterioration of the peptidoglycan layer, providing a synergic antimicrobial effect.


Asunto(s)
Antibacterianos/farmacología , Endopeptidasas/farmacología , Polietilenglicoles/química , Pseudomonas aeruginosa/crecimiento & desarrollo , Silanos/farmacología , Antibacterianos/química , Bacteriófagos/metabolismo , Biopelículas/efectos de los fármacos , Dendrímeros , Composición de Medicamentos , Sinergismo Farmacológico , Interferometría , Pruebas de Sensibilidad Microbiana , Viabilidad Microbiana/efectos de los fármacos , Microscopía Fluorescente , Plancton/efectos de los fármacos , Pseudomonas aeruginosa/efectos de los fármacos , Silanos/química
9.
Sensors (Basel) ; 21(15)2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-34372443

RESUMEN

The application areas of piezoelectric materials are expanding rapidly in the form of piezo harvesters, sensors and actuators. A path length controller is a high-precision piezoelectric actuator used in laser oscillators, especially in ring laser gyroscopes. A path length controller alters the position of a mirror nanometrically by means of a control voltage to stabilize the route that a laser beam travels in an integral multiple of laser wavelength. The design and verification of a path length controller performance requires long (up to 3 months), expensive and precise production steps to be successfully terminated. In this study, a combined computational-experimental design framework was developed to control, optimize and verify the performance of the path length controller, without the need for ring laser gyroscope assembly. A novel framework was structured such that the piezoelectric performance characteristics were calculated using finite element analysis. Then, a stand-alone measurement system was developed to verify the finite element analysis results before system integration. The final performance of the novel framework was verified by a direct measurement method called mode-scanning, which is founded on laser interferometry. The study is concluded with the explanation of measurement errors and finite element correlations.

10.
PDA J Pharm Sci Technol ; 75(6): 474-489, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33990422

RESUMEN

In the past decades, the silicone layer thickness and its distribution on the inner glass barrels of prefilled syringes have been characterized in several studies. However, the limited number of adequate methods to characterize thin baked-on silicone layers and the destructive nature of some analytical techniques suggest challenges to the inter-lab reproducibility of some methods. In this study, the measured silicone layer thickness of baked-on siliconized syringes was compared between two laboratories, both equipped with white light reflectometry coupled to laser interferometry instrumentation (Bouncer, LE UT 1.0, LE UT 2.0). The quantity of silicone oil of a subset of those syringes was measured by Fourier transform infrared spectroscopy. Glide force tests were realized as complementary measurements on both syringes analyzed by white light reflectometry coupled to laser interferometry instrumentation and on non-analyzed identical syringes from the same lot. Silicone profiles of all prefilled syringes including the limit of detection results replaced with 20 nm were comparable, but values were slightly lower when measured with the Bouncer instrument. An increase of the layer thickness from the finger flange to the needle side was found for all syringes with all instruments (20 nm to 130-140 nm). Glide force results were similar except for a difference in peak width in the break loose region between the laboratories. The mean quantities of silicone oil found by both laboratories were similar (64 µg/syringe and 69 µg/syringe). Overall, comparable results between laboratories suggest a good reproducibility of the thickness measurement method as a result of thorough method understanding and defining key method parameters. Hence this study presents a robust inter-lab comparison between silicone layer thickness measurements that has been a lack in the literature up to now.


Asunto(s)
Siliconas , Jeringas , Reproducibilidad de los Resultados , Aceites de Silicona , Espectroscopía Infrarroja por Transformada de Fourier
11.
Sensors (Basel) ; 21(5)2021 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-33801264

RESUMEN

We present a compact optical head design for wide-range and low noise displacement sensing using deep frequency modulation interferometry (DFMI). The on-axis beam topology is realised in a quasi-monolithic component and relies on cube beamsplitters and beam transmission through perpendicular surfaces to keep angular alignment constant when operating in air or in a vacuum, which leads to the generation of ghost beams that can limit the phase readout linearity. We investigated the coupling of these beams into the non-linear phase readout scheme of DFMI and implemented adjustments of the phase estimation algorithm to reduce this effect. This was done through a combination of balanced detection and the inherent orthogonality of beat signals with different relative time-delays in deep frequency modulation interferometry, which is a unique feature not available for heterodyne, quadrature or homodyne interferometry.

12.
Entropy (Basel) ; 23(3)2021 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-33802897

RESUMEN

The study of drugs diffusion through different biological membranes constitutes an essential step in the development of new pharmaceuticals. In this study, the method based on the monolayer cell culture of CHO-K1 cells has been developed in order to emulate the epithelial cells barrier in permeability studies by laser interferometry. Laser interferometry was employed for the experimental analysis of nickel(II) and cobalt(II) complexes with 1-allylimidazole or their chlorides' diffusion through eukaryotic cell monolayers. The amount (mol) of nickel(II) and cobalt(II) chlorides transported through the monolayer was greater than that of metals complexed with 1-allylimidazole by 4.34-fold and 1.45-fold, respectively, after 60 min. Thus, laser interferometry can be used for the quantitative analysis of the transport of compounds through eukaryotic cell monolayers, and the resulting parameters can be used to formulate a mathematical description of this process.

13.
Vision Res ; 178: 100-111, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33190099

RESUMEN

Eyes with the corneal ectasia keratoconus have performed better than expected (e.g. visual acuity) given their elevated levels of higher-order aberrations that cause rotationally asymmetric retinal blur. Adapted neural processing has been suggested as an explanation but has not been measured across multiple meridional orientations. Using a custom Maxwellian-view laser interferometer to bypass ocular optics, sinusoidal grating neural contrast sensitivity was measured in six eyes (three subjects) with keratoconus and four typical eyes (two subjects) at six spatial frequencies and eight orientations using a two-interval forced-choice paradigm. Total measurement duration was 24 to 28 hours per subject. Neural contrast sensitivity functions of typical eyes agreed with literature and generally showed the oblique effect on a linear-scale and rotational symmetry on a log-scale (rotational symmetry was quantified as the ratio of the minor and major radii of an ellipse fit to all orientations within each spatial frequency; typical eye mean 0.93, median 0.93; where a circle = 1). Mean sensitivities of eyes with keratoconus were 20% to 60% lower (at lower and higher spatial frequencies respectively) than typical eyes. Orientation-specific neural contrast sensitivity functions in keratoconus showed substantial rotational asymmetry (ellipse radii ratio: mean 0.84; median 0.86) and large meridional reductions. The visual image quality metric VSX was used with a permutation test to combine the asymmetric optical aberrations of the eyes with keratoconus and their measured asymmetric neural functions, which illustrated how the neural sensitivities generally mitigated the detrimental effects of the optics.


Asunto(s)
Queratocono , Sensibilidad de Contraste , Topografía de la Córnea , Humanos , Óptica y Fotónica , Visión Ocular , Agudeza Visual
14.
Sensors (Basel) ; 20(24)2020 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-33352911

RESUMEN

Non-contact optical detection of ultrasound critically depends on the amount of light collected from the detection surface. Although it can be optimized in multiple ways for an ideal flat polished surface, industrial non-destructive testing and evaluation (NDT&E) usually requires optical detectors to be robust for unpolished material surfaces that are usually rough and curved. Confocal detectors provide the best light collection but must trade off sensitivity with depth of field. Specifically, detection efficiency increases with the numerical aperture (NA) of the detector, but the depth of field drops. Therefore, fast realignment of the detector focal point is critical for in-field applications. Here, we propose an optical distance and angle correction system (DACS) and demonstrate it in a kHz-rate laser-ultrasound inspection system. It incorporates a Sagnac interferometer on receive for the fast scanning of aircraft composites, which minimizes the required initial alignment. We show that DACS performs stably for different composite surfaces while providing ±2° angular and ±2 mm axial automatic correction with a maximum 100 ms realignment time.

15.
Sensors (Basel) ; 20(17)2020 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-32899128

RESUMEN

Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the tools of choice for such measurement schemes. Using sinusoidal phase modulation homodyne interferometry allows a drastic reduction of the complexity of the optical setup, a key limitation of multi-channel interferometry. By shifting the complexity of the setup to the signal processing stage, these methods enable devices with a size and weight not feasible using conventional techniques. In this paper we present the design of a novel sensor topology based on deep frequency modulation interferometry: the self-referenced single-element dual-interferometer (SEDI) inertial sensor, which takes simplification one step further by accommodating two interferometers in one optic. Using a combination of computer models and analytical methods we show that an inertial sensor with sub-picometer precision for frequencies above 10 mHz, in a package of a few cubic inches, seems feasible with our approach. Moreover we show that by combining two of these devices it is possible to reach sub-picometer precision down to 2 mHz. In combination with the given compactness, this makes the SEDI sensor a promising approach for applications in high precision inertial sensing for both next-generation space-based gravity missions employing drag-free control, and ground-based experiments employing inertial isolation systems with optical readout.

16.
Dent J (Basel) ; 7(3)2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31374905

RESUMEN

Oral rehabilitation success depends upon the accuracy and dimensional stability of the impressions. The purpose of this study is to evaluate the dimensional changes of a first impression type VPS (Vinyl Polysiloxane) (Imprint™ 4 Preliminary Penta™ Super Quick, 3M ESPE™, St Paul, MN, USA). 10 samples were obtained from this silicone with an automatic mixing machine (Pentamix 2, 3M ESPE™, Seefeld, Germany) according to International Organization for Standardization (ISO) 4823:2000 and stored in the IPQ (Portuguese Institute for Quality) for one week. The measurements were performed by laser interferometry, according to the Michelson technique. The dimensional stability was calculated according to the formula specified in ISO (International Organization for Standardization) 4823:2000. A statistical analysis via a one-way repeated measures ANOVA was performed. The material shrinkage was 0.29 ± 0.15% after setting, 0.32 ± 0.21% at 24 h and 0.30 ± 0.23% after 1 week. No significant shrinkage of the silicone under investigation was found over time. This material can be stored for a week without the risk of clinically significant dimensional changes.

17.
Sensors (Basel) ; 18(9)2018 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-30135415

RESUMEN

The phase quadrature measurement method is capable of measuring nonlinearity in heterodyne laser interferometers with picometer accuracy whereas it cannot be applied in the new kind of heterodyne interferometers with bidirectional Doppler frequency shift especially in the condition of non-uniform motion of the target. To solve this problem, a novel measurement method of nonlinearity is proposed in this paper. By employing double-channel quadrature demodulation and substituting the external reference signal with internal ones, this method is free from the type of heterodyne laser interferometer and the motion state of the target. For phase demodulation, the phase differential algorithm is utilized to improve the computing efficiency. Experimental verification is carried out and the results indicate that the proposed measurement method achieves accuracy better than 2 pm.

18.
Philos Trans A Math Phys Eng Sci ; 376(2120)2018 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-29661977

RESUMEN

Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources-photon shot noise and quantum radiation pressure noise-which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates.This article is part of a discussion meeting issue 'The promises of gravitational-wave astronomy'.

19.
Materials (Basel) ; 11(3)2018 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-29495507

RESUMEN

In this study we fabricate gold nanocomposites and model their optical properties. The nanocomposites are either homogeneous films or gratings containing gold nanoparticles embedded in a polymer matrix. The samples are fabricated using a recently developed technique making use of laser interferometry. The gratings present original plasmon-enhanced diffraction properties. In this work, we develop a new approach to model the optical properties of our composites. We combine the extended Maxwell-Garnett model of effective media with the Rigorous Coupled Wave Analysis (RCWA) method and compute both the absorption spectra and the diffraction efficiency spectra of the gratings. We show that such a semi-analytical approach allows us to reproduce the original plasmonic features of the composites and can provide us with details about their inner structure. Such an approach, considering reasonably high particle concentrations, could be a simple and efficient tool to study complex micro-structured system based on plasmonic components, such as metamaterials.

20.
Methods Mol Biol ; 1745: 155-166, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29476468

RESUMEN

Neuronal cells are probably the less studied cells regarding their heterogeneity on a single cell or population levels. One of the main problems of studying of individual neurons is the presence of long processes (axons) on differentiated adult neurons that hamper their isolation without significant damage to the cells. Therefore, the most common method to study neuronal cells is immunofluorescent microscopy of sections of the brain, which remains poorly quantitative and allows analyzing a small number of fixed cells. Also, immunofluorescent microscopy has a number of staining artifacts since histology section has high level of autofluorescence and non-specific binding of fluorescent probes. Alternative methods that could overcome disadvantages of immunofluorescent histology include flow cytometry, scanning cytometry, and laser interferometry. Flow cytometry and, to some extent of degree, scanning cytometry allow performing analysis of multiple markers with a low level of non-specific background and very robust statistics. Laser interferometry allows studies intact, alive neurons without staining. Limitations and advantages of these methods are discussed in this chapter.


Asunto(s)
Citometría de Flujo/métodos , Interferometría/métodos , Rayos Láser , Neuronas/metabolismo , Animales , Biomarcadores , Humanos , Ratones , Coloración y Etiquetado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA