Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
J Biochem ; 174(3): 279-289, 2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37279646

RESUMEN

Protein methylation is mainly observed in lysine, arginine and histidine residues. Histidine methylation occurs at one of two different nitrogen atoms of the imidazole ring, producing Nτ-methylhistidine and Nπ-methylhistidine, and it has recently attracted attention with the identification of SETD3, METTL18 and METTL9 as catalytic enzymes in mammals. Although accumulating evidence had suggested the presence of more than 100 proteins containing methylated histidine residues in cells, much less information has been known regarding histidine-methylated proteins than lysine- and arginine-methylated ones, because no method has been developed to identify substrates for histidine methylation. Here, we established a method to screen novel target proteins for histidine methylation, using biochemical protein fractionation combined with the quantification of methylhistidine by LC-MS/MS. Interestingly, the differential distribution pattern of Nτ-methylated proteins was found between the brain and skeletal muscle, and identified γ-enolase where the His-190 at the Nτ position is methylated in mouse brain. Finally, in silico structural prediction and biochemical analysis showed that the His-190 in γ-enolase is involved in the intermolecular homodimeric formation and enzymatic activity. In the present study, we provide a new methodology to find histidine-methylated proteins in vivo and suggest an insight into the importance of histidine methylation.


Asunto(s)
Histidina , Metilhistidinas , Ratones , Animales , Metilhistidinas/análisis , Histidina/metabolismo , Lisina/metabolismo , Isoenzimas , Cromatografía Liquida , Espectrometría de Masas en Tándem , Proteínas , Fosfopiruvato Hidratasa , Arginina , Mamíferos
2.
J Biochem ; 174(3): 253-266, 2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37098187

RESUMEN

Sphingosine 1-phosphate (S1P) is one of the lipid mediators involved in diverse physiological functions. S1P circulates in blood and lymph bound to carrier proteins. Three S1P carrier proteins have been reported, albumin, apolipoprotein M (ApoM) and apolipoprotein A4 (ApoA4). The carrier-bound S1P exerts its functions via specific S1P receptors (S1PR1-5) on target cells. Previous studies showed several differences in physiological functions between albumin-bound S1P and ApoM-bound S1P. However, molecular mechanisms underlying the carrier-dependent differences have not been clarified. In addition, ApoA4 is a recently identified S1P carrier protein, and its functional differences from albumin and ApoM have not been addressed. Here, we compared the three carrier proteins in the processes of S1P degradation, release from S1P-producing cells and receptor activation. ApoM retained S1P more stable than albumin and ApoA4 in the cell culture medium when compared in the equimolar amounts. ApoM facilitated theS1P release from endothelial cells most efficiently. Furthermore, ApoM-bound S1P showed a tendency to induce prolonged activation of Akt via S1PR1 and S1PR3. These results suggest that the carrier-dependent functional differences of S1P are partly ascribed to the differences in the S1P stability, S1P-releasing efficiency and signaling duration.


Asunto(s)
Lisofosfolípidos , Proteínas Proto-Oncogénicas c-akt , Humanos , Apolipoproteínas M/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo , Lisofosfolípidos/farmacología , Esfingosina/farmacología , Proteínas Portadoras/metabolismo , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Albúminas/metabolismo
3.
J Mass Spectrom Adv Clin Lab ; 28: 75-79, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36909288

RESUMEN

Introduction: Drug testing typically follows a one-size-fits-all approach that is inadequate in some clinical scenarios, such as child maltreatment, neglect, and unintentional drug exposure. Results from immunoassay-based testing, which are non-specific, insensitive, and far from comprehensive, can lead to unintended consequences for children and their families. Objectives: The objective of this retrospective case series study is to evaluate the utility of real-time (0-1 day) comprehensive drug testing as an alternative to immunoassay-based testing in the pediatric acute care setting. Methods: Comprehensive drug testing results obtained by mass spectrometry testing and associated medical data for all pediatric cases (0-12 years) at one institution from 2019 to 2022 were included in the analysis. The final case series (n = 7) included all cases from patients <3 years with comprehensive drug testing results that were inconsistent with medication history and/or toxicology results by immunoassay. Results: Comprehensive drug testing by mass spectrometry was ordered for 174 urine and blood samples representing 97 patients (0-12 years) from 2019 to 2022. Of these, 76 cases were from patients <3 years old; results were consistent with medication history and confirmatory for immunoassay results (n = 34), consistent with medication history (n = 14), confirmatory for immunoassay results (n = 10), negative (n = 9), or medical history was incomplete (n = 2). The remaining 7 cases were included in the final case series. Conclusions: The cases highlight the value of real-time comprehensive drug testing in acute pediatric cases. Testing results can rule out toxic exposure from the diagnostic differential when negative, and lead to appropriate medical and social interventions when positive.

4.
J Pathol Inform ; 14: 100303, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36941960

RESUMEN

Background: Reflexive laboratory testing workflows can improve the assessment of patients receiving pain medications chronically, but complex workflows requiring pathologist input and interpretation may not be well-supported by traditional laboratory information systems. In this work, we describe the development of a web application that improves the efficiency of pathologists and laboratory staff in delivering actionable toxicology results. Method: Before designing the application, we set out to understand the entire workflow including the laboratory workflow and pathologist review. Additionally, we gathered requirements and specifications from stakeholders. Finally, to assess the performance of the implementation of the application, we surveyed stakeholders and documented the approximate amount of time that is required in each step of the workflow. Results: A web-based application was chosen for the ease of access for users. Relevant clinical data was routinely received and displayed in the application. The workflows in the laboratory and during the interpretation process served as the basis of the user interface. With the addition of auto-filing software, the return on investment was significant. The laboratory saved the equivalent of one full-time employee in time by automating file management and result entry. Discussion: Implementation of a purpose-built application to support reflex and interpretation workflows in a clinical pathology practice has led to a significant improvement in laboratory efficiency. Custom- and purpose-built applications can help reduce staff burnout, reduce transcription errors, and allow staff to focus on more critical issues around quality.

6.
J Mass Spectrom Adv Clin Lab ; 28: 1-8, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36741267

RESUMEN

Introduction: Determination of folate insufficiency is of considerable interest given its importance in fetal development and red blood cell formation; however, access to blood tests may be limited due to the requirement for phlebotomy as well as controlled temperature shipping of blood specimens to laboratories for testing due to the inherent instability of folate and its vitamers. Methods: An LC-MS/MS test was developed and validated for the measurement of 5-methyltetrahydrofolate (5MTHF) in dried plasma specimens collected from fingerstick blood using a laminar flow blood separation device, as well as liquid venous plasma for comparison. Two pre-analytical factors investigated influencing the measurement of 5MTHF in dried plasma were hemolysis of the fingerstick blood during collection and storage/shipment of the dried plasma. Results: Although observed infrequently, hemolysis >10 % resulted in elevated 5MTHF measurements, but hemolysis >1 % resulted in elevated chloride measurements, which were necessary to normalize 5MTHF measurements for variation in volume of dried plasma specimens. Stability of 5MTHF was improved in dried plasma relative to liquid plasma at ambient temperatures, but not sufficiently to allow for uncontrolled temperature shipping despite controlling for humidity and light exposure. Shipping studies emulating ISTA procedure 7D were conducted with a reusable cold packaging solution. The packaging failed to stabilize 5MTHF in dried plasma specimens during a 2-day summer shipping evaluation, but did provide sufficient temperature control to stabilize 5MTHF during the overnight shipping evaluation. Conclusion: Our studies provide boundary conditions with respect to hemolysis, storage, and shipping for successful analysis of 5MTHF from dried plasma specimens.

8.
J Mass Spectrom Adv Clin Lab ; 27: 40-48, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36619216

RESUMEN

Objectives: Highly selective and sensitive multi-analyte methods for the analysis of steroids are attractive for the diagnosis of endocrine diseases. Commercially available kits are increasingly used for this purpose. These methods involve laborious solid phase extraction, and the respective panels of target analytes are incomplete. We wanted to investigate whether an improvement of kit solutions is possible by introducing automated on-line solid phase extraction (SPE) and combining originally separate analyte panels. Methods: Sample preparation was performed using automated on-line SPE on a high-pressure stable extraction column. Chromatographic separation, including isobaric compounds, was achieved using a 0.25 mM ammonium fluoride-methanol gradient on a small particle size biphenyl column. Standard compounds and internal standard mixtures of two panels of a commercially available kit were combined to achieve an optimized and straightforward detection of 15 endogenous steroids. Validation was performed according to the European Medicines Agency (EMA) guidelines with slight modifications. Results: Validation was successfully performed for all steroids over a clinically relevant calibration range. Deviations of intra- and inter-assay accuracy and precision results passed the criteria and no relevant matrix effects were detected due to highly effective sample preparation. External quality assessment samples showed the applicability as a routine diagnostic method, which was affirmed by the analyses of anonymized clinical samples. Conclusions: It was found possible to complement a commercially available kit for quantitative serum steroid profiling based on isotope dilution LC-MS/MS by implementing automated on-line SPE, thereby improving the practicality and robustness of the measurement procedure.

9.
J Mass Spectrom Adv Clin Lab ; 27: 24-32, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36593910

RESUMEN

Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients. Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase. Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra- and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione. Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.

10.
Artículo en Inglés | MEDLINE | ID: mdl-36593927

RESUMEN

We study for the first time whether triphenylphosphonium (TPP) moiety can improve cellular delivery and redox properties of amphipathic cationic peptides based on YRFK/YrFK cell-penetrating and cytoprotective motif. TPP moiety was found to increase reducing activity of both stereoisomeric peptides in solution and on electrode surface in association with TPP-mediated intramolecular interactions. Among TPP-conjugated peptides, newly synthesized TPP3-YrFK featured both increased antioxidant efficacy and proteolytic resistance. TPP-conjugated peptides preferably mitigated endogenic ROS in mitochondria and cytoplasm of model glioblastoma cells with increased oxidative status. This anti-ROS effect was accompanied by mild reversible decrease of reduced glutathione level in the cells with relatively weak change in glutathione redox forms ratio. Such low interference with cell redox status is in accordance with non-cytotoxic nature of the compounds. Intracellular concentrations of label-free peptides were analyzed by LC-MS/MS, which showed substantial TPP-promoted penetration of YrFK motif across cell plasma membrane. However, according to ΔΨm analysis, TPP moiety did not profoundly enhance peptide interaction with mitochondrial inner membrane. Our study clarifies the role of TPP moiety in cellular delivery of amphipathic cationic oligopeptides. The results suggest TPP moiety as a multi-functional modifier for the oligopeptides which is capable of improving cellular pharmacokinetics and antioxidant activity as well as targeting increased ROS levels. The results encourage further investigation of TPP3-YrFK as a peptide antioxidant with multiple benefits.

11.
J Mass Spectrom Adv Clin Lab ; 26: 48-59, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36532696

RESUMEN

Background: Optimizing antimicrobial therapy to attain drug exposure that limits the emergence of resistance, effectively treats the infection, and reduces the risk of side effects is of a particular importance in critically ill patients, in whom normal functions are augmented or/and are infected with pathogens less sensitive to treatment. Achievement of these goals can be enhanced by therapeutic drug monitoring (TDM) for many antibiotics. A liquid chromatography tandem mass spectrometry (LC-MS/MS) method is presented here for simultaneous quantification of ten antimicrobials: cefazolin (CZO), cefepime (CEP), cefotaxime (CTA), ceftazidime (CTZ), ciprofloxacin (CIP), flucloxacillin (FLU), linezolid (LIN), meropenem (MER), piperacillin (PIP) and tazobactam (TAZ) in human plasma. Methods: Plasma samples were precipitated with acetonitrile and injected into the LC-MS/MS. Chromatographic separation was on a Waters Acquity BEH C18 column. Compounds were eluted with water and acetonitrile containing 0.1 % formic acid, using a gradient (0.5-65 % B), in 3.8 min. The flow rate was 0.4 mL/min, and the run time was 5.8 min. Results: The calibration curves were linear across the tested concentration ranges (0.5-250, CZO, CEP, CTA, CTZ and FLU; 0.2-100, MER and TAZ; 0.1-50, CIP and LIN and 1-500 mg/L, PIP). The intra and inter-day imprecision was < 11 %. Accuracy ranged from 95 to 114 %. CTZ and MER showed ionization suppression while CIP showed ionization enhancement, which was normalized with the use of the internal standard. Conclusion: An LC-MS/MS method for simultaneous quantification of ten antimicrobials in human plasma was developed for routine TDM.

12.
Toxicol Rep ; 9: 1674-1680, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36518403

RESUMEN

Regulations often are imposing long postmortem times before autopsy leading to certain toxicity-unrelated changes in biomarkers, which in turn may affect the reliability of toxicity evaluation during forensic investigations. Since methomyl pesticide shows significant toxicity and is frequently encountered in poisoning cases, the current study evaluated different parameters in methomyl intoxicated rats at three different postmortem intervals (Hour 0, Hour 3 and Hour 6). Eighteen adult Sprague Dawley rats were poisoned with methomyl to simulate actual methomyl poisoning cases. The time of death was assigned as Hour 0. The animals were divided into 3 groups (n = 6) to collect blood and tissue samples at the selected time points. Body weight, relative organ weight, protein concentration, methomyl concentration and acetylcholinesterase activity (AChE) were assessed in blood and different tissues (liver, spleen, kidney, brain, eye, and bone marrow) to evaluate the effect of postmortem sampling time. Outcomes revealed significant decreases in methomyl concentration in blood and bone marrow with advanced sampling time (P < 0.001). Similarly, there were significant reductions in AChE activity in the kidney (P < 0.01), while the enzyme activity significantly increased in brain samples (P < 0.05). Findings illustrated the importance of sampling time in toxicity studies because it could alter experimental results and impact consequent interpretations, as well as it may alter postmortem biomarkers in related forensic cases.

13.
J Mass Spectrom Adv Clin Lab ; 26: 28-33, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36388059

RESUMEN

Background: Despite its clear advantages over immunoassay-based testing, the measurement of serum thyroglobulin by mass spectrometry remains limited to a handful of institutions. Slow adoption by clinical laboratories could reflect limited accessibility to existing methods that have sensitivity comparable to modern immunoassays, as well as a lack of tools for calibration and assay harmonization. Methods: We developed and validated a liquid chromatography-tandem mass spectrometry-based assay for the quantification of serum thyroglobulin. The protocol combined peptide immunoaffinity purification using a commercially available, well-characterized monoclonal antibody and mobile phase modification with dimethylsulfoxide (DMSO) for enhanced sensitivity. To facilitate harmonization with other laboratories, we developed a novel, serum-based 5-point distributable reference material (Husky Ref). Results: The assay demonstrated a lower limit of quantification of 0.15 ng/mL (<20 %CV). Mobile phase DMSO increased signal intensity of the target peptide at least 3-fold, improving quantification at low concentrations. Calibration traceable to Husky Ref enabled harmonization between laboratories in an interlaboratory study. Conclusions: Sensitive mass spectrometry-based thyroglobulin measurement can be achieved using a monoclonal antibody during peptide immunoaffinity purification and the addition of mobile phase DMSO. Laboratories interested in deploying this assay can utilize the provided standard operating procedure and freely-available Husky Ref reference material.

14.
J Mass Spectrom Adv Clin Lab ; 26: 23-27, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36388060

RESUMEN

Background: Atovaquone has traditionally been used as an antiparasitic and antifungal agent, but recent studies have shown its potential as an anticancer agent. The high variability in atovaquone bioavailability highlights the need for therapeutic drug monitoring, especially in pediatric patients. The goal of our study was to develop and validate the performance of an assay to quantify atovaquone plasma concentrations collected from pediatric cancer patients using LC-MS/MS. Methods: Atovaquone was extracted from a 10 µL volume of K2-EDTA human plasma using a solution consisting of ACN: EtOH: DMF (8:1:1 v:v:v), separated using reverse-phase chromatography, and detected using a SCIEX 5500 QTrap MS system. LC-MS/MS assay performance was evaluated for precision, accuracy, carryover, sensitivity, specificity, linearity, and interferences. Results: Atovaquone and its deuterated internal standard were analyzed using a gradient chromatographic method that had an overall cycle-time of 7.4 min per injection, and retention times of 4.3 min. Atovaquone was measured over a dynamic concentration range of 0.63 - 80 µM with a deviation within ≤ ± 5.1 % of the target value. Intra- and inter-assay precision were ≤ 2.7 % and ≤ 8.4 %, respectively. Dilutional, carryover, and interference studies were also within acceptable limits. Conclusions: Our studies have shown that our LC-MS/MS-based method is both reliable and robust for the quantification of plasma atovaquone concentrations and can be used to determine the effective dose of atovaquone for pediatric patients treated for AML.

15.
Comput Struct Biotechnol J ; 20: 5935-5951, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36382190

RESUMEN

Glycolipid metabolism disorder are major threats to human health and life. Genetic, environmental, psychological, cellular, and molecular factors contribute to their pathogenesis. Several studies demonstrated that neuroendocrine axis dysfunction, insulin resistance, oxidative stress, chronic inflammatory response, and gut microbiota dysbiosis are core pathological links associated with it. However, the underlying molecular mechanisms and therapeutic targets of glycolipid metabolism disorder remain to be elucidated. Progress in high-throughput technologies has helped clarify the pathophysiology of glycolipid metabolism disorder. In the present review, we explored the ways and means by which genomics, transcriptomics, proteomics, metabolomics, and gut microbiomics could help identify novel candidate biomarkers for the clinical management of glycolipid metabolism disorder. We also discuss the limitations and recommended future research directions of multi-omics studies on these diseases.

17.
J Mass Spectrom Adv Clin Lab ; 26: 1-6, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36065325

RESUMEN

Introduction: The use of illicitly manufactured synthetic opioids, specifically fentanyl and its analogs, has escalated exponentially in the United States over the last decade. Due to the targeted nature of drug detection methods in clinical laboratories and the ever-evolving list of synthetic opioids of concern, alternative analytical approaches are needed. Methods: Using the fentanyl analog screening (FAS) kit produced by the Centers for Disease Control and Prevention (CDC), we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) synthetic opioid spectral library and data acquisition method using information dependent acquisition of product ion spectra. Chromatographic retention times, limits of detection and matrix effects, in urine and serum, for the synthetic opioids in the FAS kit (n = 150) were established. All urine and serum specimens sent to a clinical toxicology laboratory for comprehensive drug testing in 2019 (n = 856) and 2021 (n = 878) were analyzed with the FAS LC-HRMS library to determine the prevalence of fentanyl analogs and other synthetic opioids, retrospectively (2019) and prospectively (2021). Results: The limit of detection (LOD) of each opioid ranged from 1 to 10 ng/mL (median, 2.5 ng/mL) in urine and 0.25-2.5 ng/mL (median, 0.5 ng/mL) in serum. Matrix effects ranged from -79 % to 86 % (median, -37 %) for urine, following dilution and direct analysis, and -80 % to 400 % (median, 0 %) for serum, following protein precipitation. The prevalence of fentanyl/fentanyl analogs in serum samples increased slightly from 2019 to 2021 while it remained the same in urine. There were only 2 samples identified that contained a fentanyl analog without the co-occurrence of fentanyl or fentanyl metabolites. Analysis of the established MS/MS spectral library revealed characteristic fragmentation patterns in most fentanyl analogs, which can be used for structure elucidation and drug identification of future analogs. Conclusions: The LC-HRMS method was capable of detecting fentanyl analogs in routine samples sent for comprehensive drug testing. The method can be adapted to accommodate testing needs for the evolving opioid epidemic.

18.
Curr Res Food Sci ; 5: 1494-1507, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36132491

RESUMEN

Yaks (Bos mutus) live in the Qinghai-Tibet plateau. The quality of yak meat is unique due to its genetic and physiological characteristics. Identification of the proteome of yak muscle could help to reveal its meat-quality properties. The common proteome, phosphoproteome, and N-glycoproteome of yak longissimus thoracis (YLT) were analyzed by liquid chromatography-tandem mass spectrometry-based shotgun analysis. A total of 1812 common proteins, 1303 phosphoproteins (3918 phosphorylation sites), and 204 N-glycoproteins (285 N-glycosylation sites) were identified in YLT. The common proteins in YLT were involved mainly in myofibril structure and energy metabolism; phosphoproteins were associated primarily with myofibril organization, regulation of energy metabolism, and signaling; N-glycoproteins were engaged mainly in extracellular-matrix organization, cellular immunity, and organismal homeostasis. We reported, for the first time, the "panorama" of the YLT proteome, specifically the N-glycoproteome of YLT. Our results provide essential information for understanding post mortem physiology (rigor mortis and aging) and the quality of yak meat.

19.
J Mass Spectrom Adv Clin Lab ; 25: 53-60, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35910410

RESUMEN

Introduction: Ocrelizumab is a monoclonal anti-CD20 antibody approved for the treatment of multiple sclerosis (MS). The clinical value of therapeutic drug monitoring (TDM) for this antibody in treatment of MS is unknown, and an adequately specific and precise quantitation method for ocrelizumab in patient serum could facilitate investigation. Liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based quantitation methods have been shown to have higher analytic specificity and precision than enzyme-linked immunosorbent assays. Objectives: To establish and validate an LC-MS/MS-based quantitation method for ocrelizumab. Methods: We present an LC-MS/MS-based quantitation method using immunocapture purification followed by trypsinization and analysis by a triple quadrupole mass analyzer obtaining results within the same day. Results: We found that the ocrelizumab peptide GLEWVGAIYPGNGDTSYNQK (Q1/Q3 Quantifier ion: 723.683+/590.77 y112+ Qualifier ion: 723.683+/672.30 y122+) can be used for quantitation and thereby developed a method for quantifying ocrelizumab in human serum with a quantitation range of 1.56 to 200 µg/mL. The method was validated in accordance with EMA requirements in terms of selectivity, carry-over, lower limit of quantitation, calibration curve, accuracy, precision and matrix effect. Ocrelizumab serum concentrations were measured in three MS patients treated with ocrelizumab, immediately before and after ocrelizumab infusion, with additional sampling after 2, 4, 8 and 12 weeks. Measured serum concentrations of ocrelizumab showed expected values for both Cmax and drug half-life over the sampled time period. Conclusion: We have established a reliable quantitation method for serum ocrelizumab that can be applied in clinical studies, facilitating the evaluation of ocrelizumab TDM in MS.

20.
J Mass Spectrom Adv Clin Lab ; 25: 44-52, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35910411

RESUMEN

Introduction: Preoperative diagnostic workup of adrenal tumors is based on imaging and hormone analyses, but charged with uncertainties. Steroid profiling by liquid chromatography tandem mass spectrometry (LC-MS/MS) in 24-h urine has shown potential to discriminate benign and malignant adrenal tumors. Our aim was to develop and validate a specific and accurate LC-MS/MS method for the quantification of deconjugated urinary marker steroids, to evaluate their pre-analytical stability and to apply the method to clinical samples of patients with adrenal tumors. Methods: A method for the quantification of 11 deconjugated steroids (5-pregnenetriol, dehydroepiandrosterone, cortisone, cortisol, α-cortolone, tetrahydro-11-deoxycortisol, etiocholanolone, pregnenolone, pregnanetriol, pregnanediol, and 5-pregnenediol) in human urine was developed and validated based on international guidelines. Steroids were enzymatically deconjugated and extracted by solid phase extraction before LC-MS/MS quantification in positive electrospray ionization mode. Results: Excellent linearity with R2 > 0.99 and intra- and inter-day precisions of < 10.1 % were found. Relative matrix effects were between 96.4 % and 101.6 % and relative recovery was between 98.2 % and 115.0 %. Sufficient pre-freeze stability for all steroids in urine was found at 20-25 °C for seven days and at 4-6 °C for up to 28 days. Samples were stable during long-term storage at -20 °C and -80 °C for 6 months. Conclusions: A sensitive and robust LC-MS/MS method for the quantification of 11 urinary steroids was developed and validated according to international guidelines. Pre-analytical matrix stability was evaluated and the suitability of the method for the analysis of clinical samples and prospective validation studies was shown.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA