Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39098957

RESUMEN

PURPOSE: Vestibular evoked myogenic potential (VEMP) is a test used to evaluate the function of otolith organs. In healthy individuals, air-conducted (AC) responses are obtained, whereas, in conductive hearing loss, the inability to transmit the signal well enough with AC stimuli has led to the need for bone-conducted (BC) stimuli. This study aimed to compare 500 Hz Chirp and Tone Burst stimuli in terms of latency and amplitude in BC cVEMP. METHODS: This prospective observational case control study included 35 healthy participants (70 ears) between the age of 20-50. Participants underwent VEMP testing with BC 500 Hz Tone Burst stimulus and 500 Hz narrow band Chirp stimulus without changing the position of the bone conducted vibrator. The intensity of the stimuli was 50 dB nHL. RESULTS: Response rate of 500 Hz TB Stimulus was 51.4% and 95.7% in Chirp stimulus. It was observed that significantly more responses were obtained with Chirp stimulus than TB stimulus (p < 0.001). In terms of p1 latency, n1 latency, both latencies were significantly shorter in Chirp stimulus (p < 0.001). p1n1 amplitude was found significantly larger in Chirp stimulus (p < 0.001). CONCLUSION: Compared to 500 Hz TB stimulus, 500 Hz Chirp stimulus results in a higher response rate, larger p1n1 amplitude, and shorter p1 and n1 latency. A higher response rate may provide a more accurate assessment of otolith organs, reducing false negatives due to signal transmission in patients.

2.
Int J Pediatr Otorhinolaryngol ; 184: 112074, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39180790

RESUMEN

AIM: This study explored the value of Chirp-auditory brainstem response (ABR) thresholds in assessing the hearing threshold of children diagnosed with auditory neuropathy spectrum disorder (ANSD). METHODS: A total of 20 children with ANSD (40 ears, aged 1.5-7.0 years, median age 4.5 years) and 31 children with sensorineural hearing loss (SNHL) (52 ears, aged 0.9-8.0 years, median age 3.7 years) were included. Besides, 25 normal children (50 ears, aged 0.8-7.5 years, median age 4.6 years) were used as controls. Chirp-ABR and behavioral audiometry were performed simultaneously among three groups of children, allowing for a comparison of the thresholds obtained through both methods. RESULTS: In ANSD children, the correlation (r-values) between the thresholds obtained from Chirp-ABR and behavioral audiometry at 500-4000 Hz were 0.84, 0.67, 0.59, and 0.60, respectively. The average threshold differences between two methods ranged from 9.7 to 13.3 dB at 500-4000 Hz. Notably, 20 % ears (8/40) exhibited considerable discrepancies (>30 dB) in thresholds at certain frequencies. For SNHL children, the r-values between two methods were 0.84, 0.89, 0.92, and 0.93, respectively. The average threshold differences between two methods were 5.7-8.2 dB at 500-4000 Hz. Similarly, in normal children, the average threshold differences between two methods ranged from 6.1 dB to 7.7 dB, the r-values were 0.81, 0.78, 0.80, and 0.80 at 500-4000 Hz, respectively. CONCLUSION: Chirp-ABR threshold is not suitable to predict the behavioral audiometry threshold in ANSD children. When there is a significant discrepancy (>30 dB) between Chirp-ABR thresholds and behavioral audiometry thresholds in hearing loss, ANSD should be highly suspected.


Asunto(s)
Umbral Auditivo , Potenciales Evocados Auditivos del Tronco Encefálico , Pérdida Auditiva Central , Pérdida Auditiva Sensorineural , Humanos , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Preescolar , Niño , Umbral Auditivo/fisiología , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Masculino , Femenino , Pérdida Auditiva Central/diagnóstico , Pérdida Auditiva Central/fisiopatología , Lactante , Estudios de Casos y Controles , Audiometría/métodos , Audiometría de Tonos Puros/métodos
3.
Sleep Med ; 119: 320-328, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38733760

RESUMEN

OBJECTIVES: To determine whether spindle chirp and other sleep oscillatory features differ in young children with and without autism. METHODS: Automated processing software was used to re-assess an extant set of polysomnograms representing 121 children (91 with autism [ASD], 30 typically-developing [TD]), with an age range of 1.35-8.23 years. Spindle metrics, including chirp, and slow oscillation (SO) characteristics were compared between groups. SO and fast and slow spindle (FS, SS) interactions were also investigated. Secondary analyses were performed assessing behavioural data associations, as well as exploratory cohort comparisons to children with non-autism developmental delay (DD). RESULTS: Posterior FS and SS chirp was significantly more negative in ASD than TD. Both groups had comparable intra-spindle frequency range and variance. Frontal and central SO amplitude were decreased in ASD. In contrast to previous manual findings, no differences were detected in other spindle or SO metrics. The ASD group displayed a higher parietal coupling angle. No differences were observed in phase-frequency coupling. The DD group demonstrated lower FS chirp and higher coupling angle than TD. Parietal SS chirp was positively associated with full developmental quotient. CONCLUSIONS: For the first time spindle chirp was investigated in autism and was found to be significantly more negative than in TD in this large cohort of young children. This finding strengthens previous reports of spindle and SO abnormalities in ASD. Further investigation of spindle chirp in healthy and clinical populations across development will help elucidate the significance of this difference and better understand this novel metric.


Asunto(s)
Trastorno Autístico , Polisomnografía , Humanos , Preescolar , Femenino , Masculino , Niño , Trastorno Autístico/fisiopatología , Lactante , Electroencefalografía , Sueño/fisiología , Fases del Sueño/fisiología
4.
Malays J Med Sci ; 31(2): 62-71, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38694577

RESUMEN

Background: Auditory brainstem response (ABR) to the level-specific (LS) CE-Chirp has been reported to provide optimum neural synchrony along cochlear partitions, theoretically improving ABR waveform resolution. Despite this promising finding, limited studies have been conducted to contrast the results between LS CE-Chirp and Click stimuli. The current study aimed to compare the results of ABR between the two stimuli (Click and LS CE-Chirp). Method: Sixty-seven normal-hearing infants, both with and without risk factors, aged less than 7 months old, participated in this study. The ABR test was conducted at 70 dBnHL using 33.3 stimulus repetition rates with both Click and LS CE-Chirp stimuli. The signal averaging was stopped at a maximum fixed signal average of 2,500 sweeps. Data were statistically compared between the two stimuli using the Wilcoxon signed-rank test. Results: The waves I and V ABRs elicited by LS CE-Chirp exhibited significantly larger amplitudes than the Click stimulus. However, the amplitude of wave III and absolute latencies were similar in both stimuli at a supra-threshold level. Conclusion: LS CE-Chirp has the advantage of larger amplitudes than the ABR from Click at the supra-threshold level (70 dBnHL) in normal-hearing infants.

5.
Sensors (Basel) ; 24(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38732952

RESUMEN

Orthogonal chirp division multiplexing (OCDM) offers a promising modulation technology for shallow water underwater acoustic (UWA) communication systems due to multipath fading resistance and Doppler resistance. To handle the various channel distortions and interferences, obtaining accurate channel state information is vital for robust and efficient shallow water UWA communication. In recent years, deep learning has attracted widespread attention in the communication field, providing a new way to improve the performance of physical layer communication systems. In this paper, the pilot-based channel estimation is transformed into a matrix completion problem, which is mathematically equivalent to the image super-resolution problem arising in the field of image processing. Simulation results show that the deep learning-based method can improve the channel distortion, outperforming the equalization performed by traditional estimator, the performance of Bit Error Rate is improved by 2.5 dB compared to the MMSE method in OCDM system. At the 7.5 to 20 dB region, it achieves better bit error rate performance than OFDM systems, and the bit error rate is reduced by approximately 53% compared to OFDM when the SNR value is 20, which is very useful in shallow water UWA channels with multipath extension and severe time-varying characteristics.

6.
Mol Ther Nucleic Acids ; 35(2): 102173, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38617973

RESUMEN

Epigenetic processes involving long non-coding RNAs regulate endothelial gene expression. However, the underlying regulatory mechanisms causing endothelial dysfunction remain to be elucidated. Enhancer of zeste homolog 2 (EZH2) is an important rheostat of histone H3K27 trimethylation (H3K27me3) that represses endothelial targets, but EZH2 RNA binding capacity and EZH2:RNA functional interactions have not been explored in post-ischemic angiogenesis. We used formaldehyde/UV-assisted crosslinking ligation and sequencing of hybrids and identified a new role for maternally expressed gene 3 (MEG3). MEG3 formed the predominant RNA:RNA hybrid structures in endothelial cells. Moreover, MEG3:EZH2 assists recruitment onto chromatin. By EZH2-chromatin immunoprecipitation, following MEG3 depletion, we demonstrated that MEG3 controls recruitment of EZH2/H3K27me3 onto integrin subunit alpha4 (ITGA4) promoter. Both MEG3 knockdown or EZH2 inhibition (A-395) promoted ITGA4 expression and improved endothelial cell migration and adhesion to fibronectin in vitro. The A-395 inhibitor re-directed MEG3-assisted chromatin remodeling, offering a direct therapeutic benefit by increasing endothelial function and resilience. This approach subsequently increased the expression of ITGA4 in arterioles following ischemic injury in mice, thus promoting arteriogenesis. Our findings show a context-specific role for MEG3 in guiding EZH2 to repress ITGA4. Novel therapeutic strategies could antagonize MEG3:EZH2 interaction for pre-clinical studies.

7.
Plants (Basel) ; 13(6)2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38592918

RESUMEN

The current repertoire of methods available for studying RNA-protein interactions in plants is somewhat limited. Employing an RNA-centric approach, particularly with less abundant RNAs, presents various challenges. Many of the existing methods were initially designed for different model systems, with their application in plants receiving limited attention thus far. The Comprehensive Identification of RNA-Binding Proteins by Mass Spectrometry (ChIRP-MS) technique, initially developed for mammalian cells, has been adapted in this study for application in Arabidopsis thaliana. The procedures have been meticulously modified and optimized for telomerase RNA, a notable example of a low-abundance RNA recently identified. Following these optimization steps, ChIRP-MS can serve as an effective screening method for identifying candidate proteins interacting with any target RNA of interest.

8.
Epilepsia ; 65(6): e97-e103, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38686942

RESUMEN

The identification of the epileptogenic zone (EZ) boundaries is crucial for effective focal epilepsy surgery. We verify the value of a neurophysiological biomarker of focal ictogenesis, characterized by a low-voltage fast-activity ictal pattern (chirp) recorded with intracerebral electrodes during invasive presurgical monitoring (stereoelectroencephalography [SEEG]). The frequency content of SEEG signals was retrospectively analyzed with semiautomatic software in 176 consecutive patients with focal epilepsies that either were cryptogenic or presented with discordant anatomoelectroclinical findings. Fast activity seizure patterns with the spectrographic features of chirps were confirmed by computer-assisted analysis in 95.4% of patients who presented with heterogeneous etiologies and diverse lobar location of the EZ. Statistical analysis demonstrated (1) correlation between seizure outcome and concordance of sublobar regions included in the EZ defined by visual analysis and chirp-generating regions, (2) high concordance in contact-by contact analysis of 68 patients with Engel class Ia outcome, and (3) that discordance between chirp location and the visually outlined EZ correlated with worse seizure outcome. Seizure outcome analysis confirms the fast activity chirp pattern is a reproducible biomarker of the EZ in a heterogeneous group of patients undergoing SEEG.


Asunto(s)
Electroencefalografía , Epilepsias Parciales , Humanos , Femenino , Masculino , Adulto , Epilepsias Parciales/fisiopatología , Epilepsias Parciales/cirugía , Epilepsias Parciales/diagnóstico , Electroencefalografía/métodos , Estudios Retrospectivos , Adolescente , Persona de Mediana Edad , Adulto Joven , Niño , Electrodos Implantados , Preescolar , Electrocorticografía/métodos
9.
Front Vet Sci ; 11: 1358410, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38511189

RESUMEN

Introduction: Auditory brainstem response (ABR) is the gold standard for hearing testing in dogs. ABR is commonly used in puppies to diagnose congenital sensorineural deafness. Long test times limit the use for a more comprehensive hearing screening in veterinary practice. This study aimed to establish a super-fast hearing screening protocol in dogs. Methods: Hearing thresholds were routinely measured with a mobile device designed for newborn hearing screening in 90 dogs. We introduced modifications of the ABR protocol, e. g., a binaural test mode, higher stimulus rates, a broadband chirp stimulus, and an algorithm for automatic peak V detection in a stepwise fashion. Hearing thresholds were then measured with fast protocols utilizing either 30 Hz click or 90 Hz broadband chirp stimuli with 80, 60, 40, 30, 20, 10, 0 and -10 dBnHL stimulation intensities. Interrater reliability, agreement between click and chirp hearing thresholds and correlations with clinical characteristics of the dogs were assessed. Results: Using all innovations, the test time for hearing threshold assessment in both ears was reduced to 1.11 min (mean). The chirp stimulus accentuated both, peak V and the subsequent trough, which are essential features for judgement of the hearing threshold, but preceding peaks were less conspicuous. Interrater reliability and agreement between click and chirp hearing threshold was excellent. Dogs >10 years of age and dogs with abnormal hearing score or otitis score had significantly higher hearing thresholds than younger dogs (p ≤ 0.001) or dogs without abnormalities (p < 0.001). Conclusion: The results demonstrate that modifications in ABR protocols speed-up test times significantly while the quality of the recordings for hearing threshold assessment is maintained. Modified ABR protocols enable super-fast hearing threshold assessment in veterinary practice.

10.
Fa Yi Xue Za Zhi ; 40(1): 15-19, 2024 Feb 25.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-38500456

RESUMEN

OBJECTIVES: To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold. METHODS: Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested. RESULTS: There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (P>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (P<0.05), and linear regression analysis showed a significant linear correlation between the two (P<0.05). CONCLUSIONS: The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.


Asunto(s)
Pérdida Auditiva , Audición , Adulto , Humanos , Estimulación Acústica/métodos , Umbral Auditivo/fisiología , Audición/fisiología , Pérdida Auditiva/diagnóstico , Audiometría de Tonos Puros/métodos , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología
11.
Audiol Neurootol ; 29(4): 253-262, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38437806

RESUMEN

INTRODUCTION: Aging deteriorates peripheral and central auditory structures and functions. In elders, for an accurate audiological evaluation, it is important to explore beyond the cochlear receptor. Audiograms provide an estimation of hearing thresholds, while the amplitudes and latencies of supra-threshold auditory brainstem response (ABR) can offer noninvasive measures of the auditory pathways functioning. Regarding ABR, in young populations, level-specific chirp (LS CE-chirp) stimulus has been proposed as an alternative synchronizing method to obtain larger ABR responses than those evoked by clicks. However, the supra-threshold characteristics of chirp evoked ABR, and their association to hearing thresholds is relatively unknown in the elderly. The aim of this study was to evaluate supra-threshold LS CE-chirp ABRs in an aged population by comparing their features with click ABRs, and evaluating their relationship with audiometric hearing thresholds. METHODS: We carried out a cross-sectional study to characterize the hearing of 125 adults aged over 65 years. We determined the audiometric hearing thresholds and supra-threshold ABRs elicited by LS CE-chirp and click stimuli at 80 dB nHL. We evaluated associations by means of partial correlations and covariate adjustment. We performed specific frequencies' analysis and subgroup analysis per hearing level. RESULTS: Wave V responses had significantly shorter latencies and larger amplitudes when elicited by LS CE-chirp as compared to click-evoked responses. Audiometric hearing thresholds correlated with age, but ABR characteristics did not. We found mild correlations between hearing thresholds and ABR characteristics, predominantly at higher frequencies and with chirp. We found scarce evidence of correlation between ABR characteristics and the average of behavioral hearing thresholds between 0.5 to 4 kHz (0.5-4 kHz PTA). After subgroup analysis according to the hearing level, no stronger or more significant correlations were found between ABR characteristics and 0.5-4 kHz PTA. DISCUSSION: In this study, we found that supra-threshold LS CE-chirp ABR presented some of the previously described similitudes and differences with supra-threshold click ABR in younger populations. Although, the average amplitude and latency of wave V evoked by LS CE-chirp were larger and faster than those evoked by clicks, these results should be taken with caution at the individual level, and further studies are required to state that LS CE-chirp ABRs are better than click ABRs in elders for clinical evaluations. We did not find consistent associations between hearing thresholds and supra-threshold wave V features, suggesting that these measures should be considered independently in the elderly.


Asunto(s)
Umbral Auditivo , Potenciales Evocados Auditivos del Tronco Encefálico , Humanos , Anciano , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Masculino , Femenino , Umbral Auditivo/fisiología , Estudios Transversales , Anciano de 80 o más Años , Estimulación Acústica/métodos , Audiometría de Tonos Puros , Envejecimiento/fisiología
12.
ISA Trans ; 147: 382-402, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38365527

RESUMEN

Most of the signals in the field of industrial engineering are nonstationary signals, and the accurate description of the time-frequency (TF) characteristics of nonstationary signals is important for the advancement of industrial engineering. Instantaneous frequency (IF) and group delay (GD) are common TF features used to describe nonstationary signals. Time-reassigned synchrosqueezing transform and synchrosqueezing transform are two TF analysis tools that can accurately characterize the GD and IF of nonstationary signals by squeezing the TF coefficients in the time direction and frequency direction, respectively. However, it is difficult for such two techniques to accurately characterize IF and GD simultaneously. A novel method called time-frequency squeezing transform is introduced in this paper to conquer this drawback. The technique first uses the short-time Fourier transform to calculate the time-frequency representation (TFR) of a signal, and then divides the TFR into two parts according to a chirp rate estimator. The subdivided TFR parts are then squeezed in the frequency and time directions to accurately characterize the IF and GD, respectively, and the two squeezed results are added to form a high-resolution result. The effectiveness of the proposed technique is demonstrated with numerical and experimental signals.

13.
Sensors (Basel) ; 24(2)2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38257694

RESUMEN

Methane gas concentration detection faces the challenges of increasing accuracy and sensitivity, as well as high reliability in harsh environments. The special design of the optical path structure of the sensitive element provides an opportunity to improve methane gas concentration detection. In this study, the optical path structure of the sensitive element was newly designed based on the Pyramidal beam splitter matrix. The infrared light source was modulated by multi-frequency point-signal superimposed modulation technology. At the same time, concentration detection results and confidence levels were calculated using the four-channel methane gas concentration detection algorithm based on spectral refinement. Through the experiment, it was found that the sensor enables the full-range measurement of CH4; at the lower explosive limit (LEL, CH4 LEL of 5%), the reliability level is 0.01 parts-per-million (PPM), and the limit of detection is 0.5 ppm. The sensor is still capable of achieving PPM-level detections under extreme conditions in which the sensor's optical window is covered by two-thirds and humidity is 85% or dust concentration is 100 mg/m3. Those improve the sensitivity, robustness, reliability, and accuracy of the sensor.

14.
BMC Cardiovasc Disord ; 24(1): 71, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267845

RESUMEN

BACKGROUND: As a novel circRNA, BTBD7_hsa_circ_0000563 has not been fully investigated in coronary artery disease (CAD). Our aim is to reveal the possible functional role and regulatory pathway of BTBD7_hsa_circ_0000563 in CAD via exploring genes combined with BTBD7_hsa_circ_0000563. METHODS: A total of 45 peripheral blood mononuclear cell (PBMC) samples of CAD patients were enrolled. The ChIRP-RNAseq assay was performed to directly explore genes bound to BTBD7_hsa_circ_0000563. The Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis were conducted to reveal possible functions of these genes. The interaction network was constructed by the STRING database and the Cytoscape software. The Cytoscape software were used again to identify clusters and hub genes of genes bound to BTBD7_hsa_circ_0000563. The target miRNAs of hub genes were predicted via online databases. RESULTS: In this study, a total of 221 mRNAs directly bound to BTBD7_hsa_circ_0000563 were identified in PBMCs of CAD patients via ChIRP-RNAseq. The functional enrichment analysis revealed that these mRNAs may participate in translation and necroptosis. Moreover, the interaction network showed that there may be a close relationship between these mRNAs. Eight clusters can be further subdivided from the interaction network. RPS3 and RPSA were identified as hub genes and hsa-miR-493-5p was predicted to be the target miRNA of RPS3. CONCLUSIONS: BTBD7_hsa_circ_0000563 and mRNAs directly bound to it may influence the initiation and progression of CAD, among which RPS3 and RPSA may be hub genes. These findings may provide innovative ideas for further research on CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria , MicroARNs , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/genética , ARN Circular/genética , Leucocitos Mononucleares , Biología Computacional , ARN Mensajero/genética , Proteínas Adaptadoras Transductoras de Señales , MicroARNs/genética
15.
Journal of Forensic Medicine ; (6): 15-19, 2024.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1017655

RESUMEN

Objective To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response(ABR)in adults using CE-Chirp to ana-lyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold.Methods Subjects(aged 20-77 with a total of 100 ears)who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold,and pure tone air conduction hearing threshold tests were conducted at 0.5,1.0,2.0 and 4.0 kHz,respectively,to obtain pure tone listening threshold.The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups.The correlation,differences and statistical differences between the two tests at each frequency were analyzed for all subjects.The lin-ear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established,and the feasibility of the equation was tested.Results There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold dif-ference between different hearing level groups and different age groups(P>0.05).There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance(P<0.05),and linear regression analysis showed a significant linear correla-tion between the two(P<0.05).Conclusion The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects'pure tone hearing threshold under certain conditions,and can be used as an audiological test method for forensic hearing impairment assessment.

16.
Int J Pediatr Otorhinolaryngol ; 176: 111826, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38109806

RESUMEN

BACKGROUND: Electrophysiological tests are often used to evaluate hearing loss in infants and young children with conductive hearing loss, no matter to quantify or characterize. However, there are advantages and disadvantages associated with the various electrophysiological tests that are currently available. Therefore, there is no gold standard test. This study aimed to compare the value of narrow-band (NB) CE-Chirp-induced auditory steady-state response (ASSR) and auditory brainstem response (ABR) for assessing hearing thresholds in children with conductive hearing loss. We hope to identify an effective electrophysiological testing method to evaluate conductive hearing loss and provide a reference for clinical hearing assessment of infants with conductive hearing loss. SUBJECTS: and Methods: We selected 27 children (41 ears) aged 3-6 years with otitis media with effusion (OME). Within 1 day, they underwent behavioral audiometry and NB CE-Chirp-induced ASSR and ABR tests in sequence. Pearson's correlation analysis was performed to compare behavioral audiometry thresholds and ASSR and ABR response thresholds at 500, 1000, 2000, and 4000 Hz. RESULTS: The behavioral audiometry thresholds of all children were strongly correlated with the response thresholds of the two electrophysiological tests, with correlation coefficients of 0.659, 0.605, 0.723, and 0.857 for ASSR, and 0.587, 0.684, 0.753, and 0.802 for ABR. The proportion of children with a difference of ≤10 dB between ASSR and behavioral audiometry thresholds or between ABR and behavioral audiometry thresholds was not high, especially in the low frequencies. ABR results were superior to ASSR results in terms of predicting actual hearing levels. At 0.5, 1, 2, and 4 kHz, the average differences between the behavioral hearing thresholds and ASSR thresholds in the 41 ears were 5.6, 5.7, 2, and 5.6 dB, respectively. The average differences between behavioral hearing thresholds and ABR thresholds was -5.6, -1.4, -6.8, and 3.2 dB, respectively. The hearing loss configuration of the ASSR exhibited a peaked pattern, similar to behavioral audiometry, whereas the ABR exhibited an ascending pattern. The time to perform the single-ear ASSR test was 5.9 min, whereas the ABR test took 17.0 min. CONCLUSION: ASSR and ABR induced by the NB CE-Chirp correlated well with behavioral audiometry in children with conductive hearing loss. The NB CE-Chirp ASSR has advantages in terms of testing time and hearing configuration evaluation, whereas ABR has better reliability than ASSR. However, the stability of ASSR and ABR induced by the NB CE-Chirp is poor, and the thresholds obtained cannot replace behavioral audiometry in evaluating the true hearing of children with conductive hearing loss. However, ASSR and ABR can be used as auxiliary tests for cross-validation.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico , Pérdida Auditiva , Lactante , Niño , Humanos , Preescolar , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/etiología , Reproducibilidad de los Resultados , Estimulación Acústica/métodos , Umbral Auditivo/fisiología , Audición
17.
Sensors (Basel) ; 23(23)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38067923

RESUMEN

Ultrasonic sensors are inexpensive and provide highly accurate measurements, even with simple hardware configurations, facilitating their use in various fields. When multiple ultrasonic sensors exist in the measurement space, crosstalk occurs due to other nodes, which leads to incorrect measurements. Crosstalk includes not only receiving homogeneous signals from other nodes, but also overlapping by other signals and interference by heterogeneous signals. This paper proposes using frequency sweep keying modulation to provide robustness against overlap and a faster region-based convolutional neural network (R-CNN) demodulator to reduce the interference caused by heterogeneous signals. The demodulator works by training Faster R-CNN with the spectrograms of various received signals and classifying the received signals using Faster R-CNN. Experiments implementing an ultrasonic crosstalk environment showed that, compared to on-off keying (OOK), phase-shift keying (PSK), and frequency-shift keying (FSK), the proposed method can implement CDMA even with shorter codes and is robust against overlap. Compared to correlation-based frequency sweep keying, the time-of-flight error was reduced by approximately 75%. While the existing demodulators did not consider heterogeneous signals, the proposed method ignored approximately 99% of the OOK and PSK signals and approximately 79% of the FSK signals. The proposed method performed better than the existing methods and is expected to be used in various applications.

18.
Int Tinnitus J ; 27(1): 75-81, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38050889

RESUMEN

OBJECTIVE: The purpose of this study was to compare the reliability and accuracy of chirp-based Multiple Auditory Steady State Response (MSSR) and Auditory Brainstem Response (ABR) in children. METHODS: The prospective clinical study was conducted at Selayang Hospital (SH) and Hospital Canselor Tuanku Muhriz (HCTM) within one year. A total of 38 children ranging from 3 to 18 years old underwent hearing evaluation using ABR tests and MSSR under sedation. The duration of both tests were then compared. RESULTS: The estimated hearing threshold of frequency specific chirp MSSR showed good correlation with ABR especially in higher frequencies such as 2000 Hz and 4000Hz with the value of cronbach alpha of 0.890, 0.933, 0.970 and 0.969 on 500Hz, 1000Hz, 2000Hz and 4000Hz. The sensitivity of MSSR is 0.786, 0.75, 0.957 and 0.889 and specificity is 0.85, 0.882, 0.979 and 0.966 over 500Hz, 1000Hz, 2000Hz and 4000Hz. The duration of MSSR tests were shorter than ABR tests in normal hearing children with an average of 35.3 minutes for MSSR tests and 46.4 minutes for ABR tests. This can also be seen in children with hearing loss where the average duration for MSSR tests is 40.0 minutes and 52.0 minutes for ABR tests. CONCLUSION: MSSR showed good correlation and reliability in comparison with ABR especially on higher frequencies. Hence, MSSR is a good clinical test to diagnose children with hearing loss.


Asunto(s)
Sordera , Pérdida Auditiva , Humanos , Niño , Preescolar , Adolescente , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Estudios Prospectivos , Reproducibilidad de los Resultados , Estimulación Acústica , Umbral Auditivo/fisiología , Pérdida Auditiva/diagnóstico
19.
Micromachines (Basel) ; 14(11)2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-38004851

RESUMEN

A novel high-speed directly modulated two-section distributed-feedback (TS-DFB) semiconductor laser based on the detuned-loading effect is proposed and simulated. A grating structure is designed by the reconstruction-equivalent-chirp (REC) technique. A π phase shift is introduced into the reflection grating, which can provide a narrow-band reflection region with a sharp falling slope on both sides of the reflection spectrum, thus enhancing the detuned-loading effect. Owing to its unique dual-falling-edges structure, the bandwidth can be improved even when the lasing wavelength shifts beyond the left falling edge due to a thermal effect in the actual test, in which condition the detuned-loading effect can be used twice, which greatly improves the yield. The modulation bandwidth is increased from 17.5 GHz for a single DFB laser to around 24 GHz when the lasing wavelength is located on the left falling edge of the TS-DFB laser based on the detuned-loading effect, and it can be increased to 22 GHz for the right side. An eight-channel laser array with precise wavelength spacing is investigated, with a side-mode suppression ratio (SMSR) >36 dB. In addition, TS-DFB lasers with uniform reflection gratings are studied, and simulated results show that the modulation characteristic is far inferior to the laser with a phase-shifted grating reflector.

20.
Hear Res ; 440: 108896, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37924633

RESUMEN

Objective assessment of spatial and binaural hearing deficits remains a major clinical challenge. The binaural interaction component (BIC) of the auditory brainstem response (ABR) holds promise as a non-invasive biomarker for diagnosing such deficits. However, while comparative studies have reported robust BIC in animal models, BIC in humans can sometimes be unreliably evoked even in subjects with normal hearing. Here we explore the hypothesis that the standard methodology for collecting monaural ABRs may not be ideal for electrophysiological assessment of binaural hearing. This study aims to improve ABR BIC measurements by determining more optimal stimuli to evoke it. Building on previous methodology demonstrated to enhance peak amplitude of monaural ABRs, we constructed a series of level-dependent chirp stimuli based on empirically derived latencies of monaural-evoked ABR waves I, IV and the binaural-evoked BIC DN1, the most prominent BIC peak, in a cohort of ten chinchillas. We hypothesized that chirps designed based on BIC DN1 latency would specifically enhance across-frequency temporal synchrony in the afferent inputs leading to the binaural circuits that produce the BIC and would thus produce a larger DN1 than either traditional clicks or chirps designed to optimize monaural ABRs. Compared to clicks, we found that level-specific chirp stimuli evoked significantly greater BIC DN1 amplitudes, and that this effect persisted across all stimulation levels tested. However, we found no significant differences between BICs resulting from chirps created using binaural-evoked BIC DN1 latencies and those using monaural-evoked ABR waves I or IV. These data indicate that existing level-specific, monaural-based chirp stimuli may improve BIC detectability and reduce variability in human BIC measurements.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico , Pérdida Auditiva , Animales , Humanos , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Estimulación Acústica , Audición/fisiología , Potenciales Evocados Auditivos/fisiología , Pérdida Auditiva/diagnóstico , Chinchilla
SELECCIÓN DE REFERENCIAS