Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 875
Filtrar
1.
Diagnostics (Basel) ; 14(17)2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39272671

RESUMEN

Fine-needle aspiration biopsy is crucial for modern diagnostics of endoscopic procedures and thus an efficient and reliable method for increasing biopsy yields is urgently needed. In our study, we address the limited availability and high price of the rapid onsite evaluation (ROSE) technique by introducing the technique of near-infrared on-site evaluation (NOSE) consisting of spectral measurement of near-infrared radiation (NIR) transmitted through the evaluated material. For this purpose, we designed a special optical probe consisting of two fibres, of which one is a source fibre and the second is a detector fibre. The distal ends of both fibres are brought together into one bundle which is, with the help of a special extension, applied to a cuvette with an analysed sample at a defined distance from the cuvette bottom and fixed in place. A portion of the NIR radiation received by the detector fibre after it propagates through the sample then depends on the optical and therefore morphological characteristics of the sample. Based on the measured spectral curve, we can calculate the attenuation coefficient curve and subsequently the parameter of the sample richness and the parameter characterising the autofluorescence peak as well. We found that the value of our introduced parameters is in significant relation to sample richness as well as to sample malignity. NOSE evaluation of EBUS/EUSb (endobronchial/oesophageal ultrasound bronchoscopy) specimens can be considered an easy new technique aiming to improve sampling diagnostic accuracy and to diminish costs related to the presence of a cytopathologist and related instrumentation in the endoscopy suite.

2.
J Clin Med ; 13(17)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39274342

RESUMEN

Background: Cochlear implant (CI) electrode insertion can change the mechanical state of the ear whereby wideband tympanometry absorbance (WBTA) may serve as a sensitive tool to monitor these mechanical changes of the peripheral auditory pathway after CI surgery. In WBTA, the amount of acoustic energy reflected by the tympanic membrane is assessed over a wide frequency range from 226 Hz to 8000 Hz. The objective of this study was to monitor changes in WBTA in CI recipients before and after surgery. Methods: Following otoscopy, WBTA measurements were conducted twice in both ears of 38 standard CI recipients before and in the range of 4 to 15 weeks after CI implantation. Changes from pre- to postoperative absorbance patterns were compared for the implanted as well as the contralateral control ear for six different frequencies (500 Hz, 750 Hz, 1000 Hz, 2000 Hz, 3000 Hz, 4000 Hz). Furthermore, the influence of the time point of the measurement, surgical access, electrode type, sex and side of the implantation were assessed for the implanted and the control ear in a linear mixed model. Results: A significant decrease in WBTA could be observed in the implanted ear when compared with the contralateral control ear for 750 Hz (p < 0.01) and 1000 Hz (p < 0.05). The typical two-peak pattern of WBTA measurements was seen in both ears preoperatively but changed to a one-peak pattern in the newly implanted ear. The linear mixed model showed that not only the cochlear implantation in general but also the insertion through the round window compared to the cochleostomy leads to a decreased absorbance at 750 and 1000 Hz. Conclusions: With WBTA, we were able to detect mechanical changes of the acoustical pathway after CI surgery. The implantation of a CI led to decreased absorbance in the lower frequencies and the two-peak pattern was shifted to a one-peak pattern. The result of the linear mixed model indicates that WBTA can detect mechanical changes due to cochlear implantation not only in the middle ear but also in the inner ear.

3.
ACS Appl Mater Interfaces ; 16(37): 48854-48869, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39231951

RESUMEN

The optoelectronic properties of polythiophene (PT) graft block copolymers are most important for fabricating optoelectronic devices, and recently, we reported a single-pot atom-transfer radical polymerization (ATRP) technique for preparation of PT graft block copolymers between thermoresponsive poly(diethylene glycol methyl ether methacrylate) (PDEGMEM) and pH-responsive poly(dimethyl amino ethyl methacrylate) (PDMAEMA) from the PT backbone via the "grafting from" strategy with an 11 mol % contamination. A "grafting onto" strategy has been opted to eliminate the contamination from the block copolymer where we synthesized poly(thiophene acetic acid) (P3TAA) followed by the coupling with PDEGMEM-b-PDMAEMA-Cl, PDMAEMA-b-PDEGMEM-Cl, and PDMAEMA-ran-PDEGMEM-Cl copolymers, produced separately by the ATRP technique. The polymers were characterized using 1H NMR, SEC, etc. TEM study exhibits mostly vesicular morphology and optical properties measured using UV-vis and photoluminescence spectroscopy showing pH dependent behavior. dc conductivity values indicate semiconducting nature in the order P2 > P3 > P1. The abrupt hike of P2 (∼80 times) in conductivity at pH 3 from that of previously prepared P2 copolymers formed by the grafting from process is attributed to the absence of ∼11 mol % contamination. Conductivity decreases with increasing pH, due to coiling of the PT backbone in accordance with the blue shifts of λabs peaks. The current (I)-voltage (V) plots exhibit bimodal memory and organic mixed ionic and electronic conductivity. Higher current (3.3 mA for P2, pH 3) and electronic memory occur upon light irradiation than that of dark. Photoswitching property decreases with increase of pH, showing highest photocurrent gain of 8.05 for P2 at pH 3. Photocurrent gain follows the order P2 > P3 > P1 indicating P2 is the best to develop photoswitches in the P-series polymers. Fitting of growth and decay curves suggests that they are a two-stage process: photocurrent raises fast at the on state initially and then at a slower rate and similar at an off state. Impedance spectra suggest charge-transfer resistance and Warburg impedance values follow the order of P1 > P3 > P2, whereas capacitance value follows the opposite order.

4.
ACS Appl Mater Interfaces ; 16(37): 49249-49261, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39235429

RESUMEN

Bismuth vanadate (BVO) having suitable band edges is one of the effective photocatalysts for water oxidation, which is the rate-determining step in the water splitting process. Incorporating cocatalysts can reduce activation energy, create hole sinks, and improve photocatalytic ability of BVO. In this work, the visible light active nickel tellurium oxide (NTO) is used as the cocatalyst on the BVO photoanode to improve photocatalytic properties. Different NTO amounts are deposited on the BVO to balance optical and electrical contributions. Higher visible light absorbance and effective charge cascades are developed in the NTO and BVO composite (NTO/BVO). The highest photocurrent density of 6.05 mA/cm2 at 1.23 V versus reversible hydrogen electrode (VRHE) and the largest applied bias photon-to-current efficiency (ABPE) of 2.13% are achieved for NTO/BVO, while BVO shows a photocurrent density of 4.19 mA/cm2 at 1.23 VRHE and ABPE of 1.54%. Excellent long-term stability under light illumination is obtained for NTO/BVO with photocurrent retention of 91.31% after 10,000 s. The photoelectrochemical catalytic mechanism of NTO/BVO is also proposed based on measured band structures and possible interactions between NTO and BVO. This work has depicted a novel cocatalytic BVO system with a new photocharging material and successfully achieves high photocurrent densities for catalyzing water oxidation.

5.
Hear Res ; 453: 109108, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39244840

RESUMEN

The middle-ear muscle reflex (MEMR) and medial olivocochlear reflex (MOCR) modify peripheral auditory function, which may reduce masking and improve speech-in-noise (SIN) recognition. Previous work and our pilot data suggest that the two reflexes respond differently to static versus dynamic noise elicitors. However, little is known about how the two reflexes work in tandem to contribute to SIN recognition. We hypothesized that SIN recognition would be significantly correlated with the strength of the MEMR and with the strength of the MOCR. Additionally, we hypothesized that SIN recognition would be best when both reflexes were activated. A total of 43 healthy, normal-hearing adults met the inclusion/exclusion criteria (35 females, age range: 19-29 years). MEMR strength was assessed using wideband absorbance. MOCR strength was assessed using transient-evoked otoacoustic emissions. SIN recognition was assessed using a modified version of the QuickSIN. All measurements were made with and without two types of contralateral noise elicitors (steady and pulsed) at two levels (50 and 65 dB SPL). Steady noise was used to primarily elicit the MOCR and pulsed noise was used to elicit both reflexes. Two baseline conditions without a contralateral elicitor were also obtained. Results revealed differences in how the MEMR and MOCR responded to elicitor type and level. Contrary to hypotheses, SIN recognition was not significantly improved in the presence of any contralateral elicitors relative to the baseline conditions. Additionally, there were no significant correlations between MEMR strength and SIN recognition, or between MOCR strength and SIN recognition. MEMR and MOCR strength were significantly correlated for pulsed noise elicitors but not steady noise elicitors. Results suggest no association between SIN recognition and the MEMR or MOCR, at least as measured and analyzed in this study. SIN recognition may have been influenced by factors not accounted for in this study, such as contextual cues, warranting further study.

6.
New Phytol ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294895

RESUMEN

Certain species in the Brassicaceae family exhibit high photosynthesis rates, potentially providing a valuable route toward improving agricultural productivity. However, factors contributing to their high photosynthesis rates are still unknown. We compared Hirschfeldia incana, Brassica nigra, Brassica rapa and Arabidopsis thaliana, grown under two contrasting light intensities. Hirschfeldia incana matched B. nigra and B. rapa in achieving very high photosynthesis rates under high growth-light condition, outperforming A. thaliana. Photosynthesis was relatively more limited by maximum photosynthesis capacity in H. incana and B. rapa and by mesophyll conductance in A. thaliana and B. nigra. Leaf traits such as greater exposed mesophyll specific surface enabled by thicker leaf or high-density small palisade cells contributed to the variation in mesophyll conductance among the species. The species exhibited contrasting leaf construction strategies and acclimation responses to low light intensity. High-light plants distributed Chl deeper in leaf tissue, ensuring even distribution of photosynthesis capacity, unlike low-light plants. Leaf anatomy of H. incana, B. nigra and B. rapa facilitated effective CO2 diffusion, efficient light use and provided ample volume for their high maximum photosynthetic capacity, indicating that a combination of adaptations is required to increase CO2-assimilation rates in plants.

7.
Chemosphere ; 364: 143047, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39121958

RESUMEN

Assessing historical records of DOC concentrations (DOC) in drinking water sources is important for water utilities to understand long-term planning for infrastructure needs. This study investigates 15-20 years of historical data of the Woronora water supply catchment in Australia inclusive of the water filtration plant (WFP), the lake from where the water was drawn for WFP supply, and the two primary river inputs. The DOC at each site ranged from 0.8 mg L-1 to 13.9 mg L-1, with the highest and lowest concentrations observed in Waratah Rivulet. The DOC in the lake and WFP significantly (p < 0.001) increased at annual change rates of 0.192 and 0.180 mg L-1 yr-1. However, Woronora River showed a ∼50% lower rate of DOC increase at 0.096 mg L-1 yr-1 (p < 0.001), while Waratah Rivulet showed no trend (p > 0.05). UV254 also showed increasing trends at Woronora River, Lake Woronora, and Woronora WFP, indicating an increase in aromatic DOC compounds in all three sites. Waratah Rivulet, however, transported more than 60% of the total DOC load into Lake Woronora due to high flow volumes (more than 65% of total annual system flow). Annual DOC load to the lake is positively correlated with annual rainfall (R2 > 0.92; p < 0.001). The higher percentage (>73%) of the samples had SUVA254 greater than 2 L mg -1 m-1 in all four sites indicating a dominance of hydrophobic DOC. The terrestrial plant-derived DOC has increased in Lake Woronora, predominantly influenced by historical rainfall magnitude. The results underscore the importance of considering the impact of increased DOC at the treatment plant intake for the planning and operation of the Woronora water supply system.

8.
Biology (Basel) ; 13(8)2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39194516

RESUMEN

The nutritional composition of food for animal production can be enhanced using olive tree and plant by-products due to their high content of bioactive compounds such as pentacyclic triterpenes. Here, we present a novel application of near-infrared spectroscopy (NIRS) for the prediction of the total or individual [maslinic acid (MA), oleanolic acid (OA), and uvaol (UO)] pentacyclic triterpene concentrations in a feed additive obtained from a plant mixture. The oxygen radical absorbance capacity of these types of samples demonstrated the existence of a high antioxidant capacity. The conventional determination methods of pentacyclic triterpene concentration are costly, labor-intensive, and not practical for analyzing several lines within a limited timeframe at the factory level. The optimal regression model developed in our work demonstrated high correlation values for the calibration and validation sets, along with a high residual prediction deviation value. We used 63 samples for the development of the model. The NIRS method can be applied directly to dried powder and makes extraction and high-performance liquid chromatography (HPLC) analysis unnecessary. Our results also demonstrate that NIRS can accurately quantify pentacyclic triterpenes even at low concentrations in food additives. It can be used at the factory level to directly determine the pentacyclic triterpene concentrations in the additive powder at the same time that the powder is produced.

9.
ACS Sens ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39175278

RESUMEN

Breast cancer is a major challenge in the field of oncology, with around 2.3 million cases and around 670,000 deaths globally based on the GLOBOCAN 2022 data. Despite having advanced technologies, breast cancer remains the major type of cancer among women. This review highlights various collagen signatures and the role of different collagen types in breast tumor development, progression, and metastasis, along with the use of photoacoustic spectroscopy to offer insights into future cancer diagnostic applications without the need for surgery or other invasive techniques. Through mapping of the tumor microenvironment and spotlighting key components and their absorption wavelengths, we emphasize the need for extensive preclinical and clinical investigations.

10.
J Biophotonics ; : e202400079, 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39128483

RESUMEN

Since both top and bottom illuminations are widely used in infrared transmission measurements, in this paper, we study the effects of different illuminations on the signatures in infrared microspectroscopy. By simulating a series of dielectric samples, we show that their extinction efficiency, Q ext $$ {Q}_{\mathrm{ext}} $$ , remains unchanged when the direction of the incident plane wave is reversed, even though the field distributions both inside and outside of the sample may be dramatically different. We find features in Q ext $$ {Q}_{\mathrm{ext}} $$ that are correlated with whispering gallery modes for one beam direction and correspond to completely different field distributions for the opposite beam direction. In addition, by linking the optical theorem and the reciprocity relation of far-field scattered field, we rigorously prove the invariance of Q ext $$ {Q}_{\mathrm{ext}} $$ for arbitrary dielectric targets under opposite plane-wave illuminations. Furthermore, we show the difference in the apparent absorbance spectrum for opposite beam directions when considering numerical apertures.

11.
Sensors (Basel) ; 24(16)2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39205060

RESUMEN

Nitrates can cause severe ecological imbalances in aquatic ecosystems, with considerable consequences for human health. Therefore, monitoring this inorganic form of nitrogen is essential for any water quality management structure. This research was conducted to develop a novel Nitrate Portable Measurement System (NPMS) to monitor nitrate concentrations in water samples. NPMS is a reagent-free ultraviolet system developed using low-cost electronic components. Its operation principle is based on the Beer-Lambert law for measuring nitrate concentrations in water samples through light absorption in the spectral range of 295-315 nm. The system is equipped with a ready-to-use ultraviolet sensor, light emission diode (LED), op-amp, microcontroller, liquid crystal display, quartz cuvette, temperature sensor, and battery. All the components are assembled in a 3D-printed enclosure box, which allows a very compact self-contained equipment with high portability, enabling field and near-real-time measurements. The proposed methodology and the developed instrument were used to analyze multiple nitrate standard solutions. The performance was evaluated in comparison to the Nicolet Evolution 300, a classical UV-Vis spectrophotometer. The results demonstrate a strong correlation between the retrieved measurements by both instruments within the investigated spectral band and for concentrations above 5 mg NO3-/L.

12.
Sci Rep ; 14(1): 19657, 2024 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-39179633

RESUMEN

Special attention is given to the pharmacological treatment of combined medication of Carvedilol and hydrochlorothiazide which is the most effective and the most beneficial therapy for hypertensive patients with diabetes and various metabolic comorbidities. This work represents spectrophotometric platform scenarios based on factorized spectrum (FS) using interpoint data difference resolution scenarios (IDDRS) coupled with spectrum subtraction method (SS) for the concurrent quantification of carvedilol (CAR) and hydrochlorothiazide (HCT) when present together in a combination without the need for any initial physical separation steps. This IDD resolution scenario based on manipulating the zero-order spectra (D0) of both drugs in the mixture with various spectral features at different wavelength regions (200-400 nm), region I (220-250 nm), region II (240-300 nm) and region III (270-320 nm) via absorbance resolution (AR) and induced absorbance resolution (IAR) methods coupled with corresponding spectrum subtraction (SS). The calibration curves were established across the linearity ranges of 2.0-12.0 µg/mL at 242.50 nm and 4.0-40.0 µg/mL at 285.5 nm for CAR and 1.0-11.0 µg/mL at 226.10 nm and 2.0-20.0 µg/mL at 270.5 nm for HCT. Moreover, methods' validation was confirmed via ICH guidelines. A Multicenter comparison between sensitivity, specificity in respect resolution sequence were applied using different wavelength regions with various concentration ranges was applied and finally spectral resolution recommendation is issued and cumulative validation score (CVS) is calculated as an indicator in the risk analysis. In quality control laboratories, the studied approaches are applicable for conducting analysis on the mentioned drugs. In addition, the selection of spectrophotometry aligns with the principles of green analytical chemistry, an approach that resonates with the overarching theme of minimizing environmental impact. Via four metric tools named: analytical greenness (AGREE), green analytical procedure index (GAPI), analytical eco-scale, and national environmental method index (NEMI), methods' greenness profile was guaranteed.


Asunto(s)
Carvedilol , Hidroclorotiazida , Espectrofotometría , Carvedilol/análisis , Hidroclorotiazida/análisis , Espectrofotometría/métodos , Medición de Riesgo , Humanos , Antihipertensivos/análisis
13.
Angew Chem Int Ed Engl ; : e202409610, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39087463

RESUMEN

Recent decades have seen a dramatic increase in the commercial use of biocatalysts, transitioning from energy-intensive traditional chemistries to more sustainable methods. Current enzyme engineering techniques, such as directed evolution, require the generation and testing of large mutant libraries to identify optimized variants. Unfortunately, conventional screening methods are unable to screen such large libraries in a robust and timely manner. Droplet-based microfluidic systems have emerged as a powerful high-throughput tool for library screening at kilohertz rates. Unfortunately, almost all reported systems are based on fluorescence detection, restricting their use to a limited number of enzyme types that naturally convert fluorogenic substrates or require the use of surrogate substrates. To expand the range of enzymes amenable to evolution using droplet-based microfluidic systems, we present an absorbance-activated droplet sorter that allows of droplet sorting at kilohertz rates without the need for optical monitoring of the microfluidic system. To demonstrate the utility of the sorter, we rapidly screen a 105-member aldehyde dehydrogenase library towards D-glyceraldehyde using a NADH mediated coupled assay that generates WST-1 formazan as the colorimetric product. We successfully identify a variant with a 51% improvement in catalytic efficiency and a significant increase in overall activity across a broad substrate spectrum.

14.
Sensors (Basel) ; 24(14)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39065927

RESUMEN

Zn2+ has a crucial role both in biology and the environment, while Pb2+ presents serious hazards in the same areas due to its toxicity, and the need for their analysis often exceeds available instrumental capacity. We report, herein, a new high-throughput optochemical screening method for Zn2+ and Pb2+ in various solutions. Moreover, we also introduced a new and generalizable three-step-microplate-modification technique, including plasma treating, linker-docking and photocatalytic copolymerization. The surface of a commercially available 96-well-cycloolefin-microplate was treated with atmospheric plasma, and then, the bottoms of the wells were covered by covalently attaching a methacrylate-containing linker-monolayer. Finally, the preactivated microplate wells were covalently functionalized by immobilizing bis(acridino)-crown ether-type sensor molecules, via photocatalytic copolymerization, to a polymethacrylate backbone. This sensing tool can be used in all microplate readers, is compatible with liquid handling platforms and provides an unprecedently fast monitoring (>1000 samples/hour, extrapolated from the time required for 96 measurements) of dissolved Zn2+ and Pb2+ among recent alternatives above the detection limits of 8.0 × 10-9 and 3.0 × 10-8 mol/L, respectively, while requiring a sample volume of only 20 µL.

15.
J Hazard Mater ; 477: 135371, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39084014

RESUMEN

Salicylic esters (SEs), the widely used ultraviolet (UV) absorbers in sunscreen products, have been found to have health risks such as skin sensitization and estrogenic effects. This study aims to design SE substitutes that maintain high UV absorbance while reducing estrogenicity. Using molecular docking and Gaussian09 software for initial assessments and further application of a combination of two-dimensional and three-dimensional quantitative structure-activity relationships (2D-QSAR and 3D-QSAR, respectively) models, we designed 73 substitutes. The best-performing molecules, ethylhexyl salicylate (EHS)-5 and EHS-15, significantly reduced estrogenicity (44.54 % and 17.60 %, respectively) and enhanced UV absorbance (249.56 % and 46.94 %, respectively). Through screening for human health risks, we found that EHS-5 and EHS-15 were free from skin sensitivity and eye irritation and exhibited reduced skin permeability compared with EHS. Furthermore, the photolysis and synthetic pathways of EHS-5 and EHS-15 were deduced, demonstrating their good photodegradability and potential synthesizability. In addition, we analyzed the mechanisms underlying the changes in estrogenic effects and UV absorption properties. We identified covalent hydrogen bond basicity and acidity Propgen value for atomic molecular properties and the highest occupied molecular orbital eigenvalue as the main factors affecting the estrogenic effect and UV absorbance of SEs, respectively. This study focuses on the design and screening of SEs, exhibiting enhanced functionality, reduced health risks, and synthetic feasibility.


Asunto(s)
Estrógenos , Simulación del Acoplamiento Molecular , Relación Estructura-Actividad Cuantitativa , Salicilatos , Protectores Solares , Protectores Solares/química , Protectores Solares/toxicidad , Salicilatos/química , Salicilatos/toxicidad , Estrógenos/química , Estrógenos/toxicidad , Humanos , Rayos Ultravioleta , Fotólisis , Animales , Piel/efectos de los fármacos , Piel/efectos de la radiación
16.
Heliyon ; 10(13): e33776, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39040356

RESUMEN

Objectives: This study aimed to assess the clinical significance of Wideband Absorbance (WBA) in children with Large Vestibular Aqueduct Syndrome (LVAS), which could potentially serve as diagnostic and predictive markers for LVAS in children. Design: This was a single-center retrospective case-control study. Audiological measurements and Wideband Acoustic Immittance (WAI) were performed. Propensity score matching (PSM) was considered to treat group imbalance. The Receiver Operating Characteristic (ROC) curves and area under the ROC curve (AUC) were used to evaluate the sensitivity and specificity of WBA. Study sample: Participants included 42 children with LVAS and 163 normal children aged 6 months -11 years recruited from clinical audiology settings between 2019 and 2021. Results: The WBA at Tympanometric Peak Pressure (WBATPP) and Ambient Pressure (WBAA) in the LVAS group were significantly lower than those of the control group at 1259-2000 Hz but higher at 4000-6349 Hz (p < 0.05, power >0.8). The WBAA (1587 Hz) AUC value was 0.805, identifying a score ≤0.565 as indicative of a LVAS risk. Conclusions: WBA holds promise in distinguishing LVAS from the normal condition and warrants further exploration as a tool to examine the influence of inner ear pressure on acoustic energy transmission in the middle ear.

17.
BioTechnologia (Pozn) ; 105(2): 121-136, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38988364

RESUMEN

Oxidative stress-related pathologies have guided the scientific community into delving into natural product-based research on plant-based metabolites. Plant secondary metabolites serve as a valid alternative in managing oxidative stress-related pathologies. In this study, we present the secondary metabolite constituents of the polar extract (PE) and nonpolar extract (NPE) from the leaves of Bryophyllum pinnatum. These constituents were determined through qualitative and quantitative phytochemical screening. The functional groups and structures of these metabolites were determined based on FTIR and GC-MS experiments, respectively. Antioxidant and free radical scavenging (FRS) activities were determined using standard methods, including phosphomolybdenum, FRAP, DPPH, HRSA, and reducing power assays, with comparisons made to the ascorbic acid (AA) standard. Through Pearson correlation analysis, we estimated the relationship between antioxidant and FRS activities. The DPPH results revealed IC50s of 380.104 ± 0.001, 16.763 ± 0.001, and 7.684 ± 0.003 µg/ml for NPE, AA, and PE, respectively, indicating a trend of PE > AA > NPE. However, all other experiments showed a trend of AA > PE > NPE in antioxidant and FRS activities. These results showed the potential antioxidant and FRS properties of both PE and NPE. Additionally, the correlation analysis indicated a strong positive correlation between the antioxidant and FRS activities of PE and NPE. The research results suggest high antioxidant and FRS activities of PE and validate the use of B. pinnatum in managing free radical-related pathologies.

18.
Sci Rep ; 14(1): 15510, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38969827

RESUMEN

The optoelectronic and structural characteristics of the Zn1-xCrxSe (0 ≤ x ≤ 1) semiconductor are reported by employing density functional theory (DFT) within the mBJ potential. The findings revealed that the lattice constant decreases with increasing Cr concentration, although the bulk modulus exhibits the opposite trend. ZnSe is a direct bandgap material; however, a change from direct to indirect electronic bandgap has been seen with Cr presence. This transition is caused by structural alterations by Cr and defects forming, which results in novel optical features, including electronic transitions. The electronic bandgap decreases from 2.769 to 0.216 eV, allowing phonons to participate and improving optical absorption. A higher concentration of Cr boosts infrared absorption and these Cr-based ZnSe (ZnCrSe) semiconductors also cover a wider spectrum in the visible range from red to blue light. Important optical parameters such as reflectance, optical conductivity, optical bandgap, extinction coefficient, refractive index, magnetization factor, and energy loss function are discussed, providing a theoretical understanding of the diverse applications of ZnCrSe semiconductors in photonic and optoelectronic devices.

19.
J Biophotonics ; : e202400052, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38952197

RESUMEN

A Mueller matrix polarimetry system at 532 nm wavelength is developed for noninvasive glucose sensing in turbid media such as human's fingertip. The system extracts mean absorbance and anisotropic properties, demonstrated numerically and experimentally with phantom glucose samples. It is found that mean absorbance ( A e $$ {A}_e $$ ), depolarization index (Δ), and linear dichroism (LD) show linear variation with glucose concentration 100-500 mg/dL. In addition, LightTools simulations indicate proportional scaling of scattering effects with A e $$ {A}_e $$ , Δ, and LD. Real-world tests on fingertip show a strong correlation between these properties and blood glucose levels with a mean absolute relative deviation (MARD) of 12.56% and a correlation coefficient (R2) of 0.875 in prediction by a neural network (NN) model, highlighting the advantages of Mueller matrix in extracting more parameters related to blood glucose.

20.
J Chromatogr A ; 1730: 465099, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38901298

RESUMEN

A miniaturized microchip-based absorbance detector was developed for portable high-performance liquid chromatography (HPLC) to test glycated hemoglobin (HbA1c). The microchip integrating a Z-shaped cell, two collimating micro-lenses and two ink-filled optical slits is small in size (30 mm × 15 mm × 7 mm). The Z-shaped cell has a cross-sectional size of 500 µm × 500 µm and a physical optical path length of 2 mm. Two collimating micro-lenses were inserted in empty grooves on both sides of the cell, one micro-lens for collimating the initial light and the other for focusing the transmitted light. Optical slits on each end of the cell were used to block the stray light. Therefore, this detector indicated a low stray light level (0.011 %) and noise level (2.5 × 10-4 AU). This detector was applied for the commercial HPLC system to detect HbA1c level, and showed a low limit of detection (0.5 µg/mL) and excellent repeatability (≤ 2.03 %). The sensitivity was enhanced by 3.4 times when the optical path length was increased from 0.5 mm to 2 mm and the stray light was blocked by optical slits. The miniaturized microchip-based absorbance detector developed shows a great potential for application in portable and compact HPLC.


Asunto(s)
Diseño de Equipo , Hemoglobina Glucada , Límite de Detección , Cromatografía Líquida de Alta Presión/métodos , Hemoglobina Glucada/análisis , Humanos , Dispositivos Laboratorio en un Chip , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA