Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 629
Filtrar
1.
Pediatr Surg Int ; 40(1): 251, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39251414

RESUMEN

BACKGROUND: The technical complexity and limited casuistry of neonatal surgical pathology limit the possibilities of developing the necessary technical competencies by specialists in training. Esophageal atresia constitutes the paradigm of this problem. The use of synthetic 3D models for training is a promising line of research, although the literature is limited. METHODS: We conceptualized, designed, and produced an anatomically realistic model for the open correction of type III oesophageal atresia. We validated it with two groups of participants (experts and non-experts) through face, construct, and content-validity questionnaires. RESULTS: The model was validated by nine experts and nine non-experts. The mean procedure time for the experts and non-experts groups was 34.0 and 38.4 min, respectively. Two non-experts did not complete the procedure at the designed time (45 min). Regarding the face validity questionnaire, the mean rating of the model was 3.2 out of 4. Regarding the construct validity, we found statistically significant differences between groups for the equidistance between sutures, 100% correct in the expert group vs. 42.9% correct in the non-expert group (p = 0.02), and for the item "Confirms that tracheoesophageal fistula closure is watertight before continuing the procedure", correctly assessed by 66.7% of the experts vs. by 11.1% of non-experts (p = 0.05). Concerning content validity, the mean score was 3.3 out of 4 for the experts and 3.4 out of 4 for the non-experts. CONCLUSIONS: The present model is a cost-effective, simple-to-produce, and validated option for training open correction of type III esophageal atresia. However, future studies with larger sample sizes and blinded validators are needed before drawing definitive conclusions.


Asunto(s)
Atresia Esofágica , Modelos Anatómicos , Atresia Esofágica/cirugía , Humanos , Competencia Clínica , Entrenamiento Simulado/métodos , Pediatría/educación , Encuestas y Cuestionarios , Cirujanos/educación
2.
Biol Methods Protoc ; 9(1): bpae060, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39234439

RESUMEN

Spheroid cultures of cancer cell lines or primary cells represent a more clinically relevant model for predicting therapy response compared to two-dimensional cell culture. However, current live-dead staining protocols used for treatment response in spheroid cultures are often expensive, toxic to the cells, or limited in their ability to monitor therapy response over an extended period due to reduced stability. In our study, we have developed a cost-effective method utilizing calcein-AM and Helix NP™ Blue for live-dead staining, enabling the monitoring of therapy response of spheroid cultures for up to 10 days. Additionally, we used ICY BioImage Analysis and Z-stacks projection to calculate viability, which is a more accurate method for assessing treatment response compared to traditional methods on spheroid size. Using the example of glioblastoma cell lines and primary glioblastoma cells, we show that spheroid cultures typically exhibit a green outer layer of viable cells, a turquoise mantle of hypoxic quiescent cells, and a blue core of necrotic cells when visualized using confocal microscopy. Upon treatment of spheroids with the alkylating agent temozolomide, we observed a reduction in the viability of glioblastoma cells after an incubation period of 7 days. This method can also be adapted for monitoring therapy response in different cancer systems, offering a versatile and cost-effective approach for assessing therapy efficacy in three-dimensional culture models.

3.
Cell Rep Methods ; 4(9): 100845, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39236715

RESUMEN

Two-dimensional neuronal cultures have a limited ability to recapitulate the in vivo environment of the brain. Here, we introduce a three-dimensional in vitro model for human glia-to-neuron conversion, surpassing the spatial and temporal constrains of two-dimensional cultures. Focused on direct conversion to induced dopamine neurons (iDANs) relevant to Parkinson disease, the model generates functionally mature iDANs in 2 weeks and allows long-term survival. As proof of concept, we use single-nucleus RNA sequencing and molecular lineage tracing during iDAN generation and find that all glial subtypes generate neurons and that conversion relies on the coordinated expression of three neural conversion factors. We also show the formation of mature and functional iDANs over time. The model facilitates molecular investigations of the conversion process to enhance understanding of conversion outcomes and offers a system for in vitro reprogramming studies aimed at advancing alternative therapeutic strategies in the diseased brain.


Asunto(s)
Neuronas Dopaminérgicas , Neuroglía , Humanos , Neuronas Dopaminérgicas/metabolismo , Neuroglía/metabolismo , Diferenciación Celular , Células Cultivadas
4.
Acta Neurochir (Wien) ; 166(1): 378, 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39316122

RESUMEN

OBJECTIVES: A deep knowledge of the surgical anatomy of the target area is mandatory for a successful operative procedure. For this purpose, over the years, many teaching and learning methods have been described, from the most ancient cadaveric dissection to the most recent virtual reality, each with their respective pros and cons. Photogrammetry, an emergent technique, allows for the creation of three-dimensional (3D) models and reconstructions. Thanks to the spreading of photogrammetry nowadays it is possible to generate these models using professional software or even smartphone apps. This study aims to compare the neuroanatomical photogrammetric models generated by the two most utilized smartphone applications in this domain, Metascan and 3D-Scanner, through quantitative analysis. METHODS: Two human head specimens (four sides) were examined. Anatomical dissection was segmented into five stages to systematically expose well-defined structures. After each stage, a photogrammetric model was generated using two prominent smartphone applications. These models were then subjected to both quantitative and qualitative analysis, with a specific focus on comparing the mesh density as a measure of model resolution and accuracy. Appropriate consent was obtained for the publication of the cadaver's image. RESULTS: The quantitative analysis revealed that the models generated by Metascan app consistently demonstrated superior mesh density compared to those from 3D-Scanner, indicating a higher level of detail and potential for precise anatomical representation. CONCLUSION: Enabling depth perception, capturing high-quality images, offering flexibility in viewpoints: photogrammetry provides researchers with unprecedented opportunities to explore and understand the intricate and magnificent structure of the brain. However, it is of paramount importance to develop and apply rigorous quality control systems to ensure data integrity and reliability of findings in neurological research. This study has demonstrated the superiority of Metascan in processing photogrammetric models for neuroanatomical studies.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39311942

RESUMEN

BACKGROUND: Hip-preserving surgery in young patients frequently reveals lesions of the ligamentum teres (LT). Histological and clinical evidence supports that those lesions could be source of intraarticular hip pain. It has been hypothesized that LT degeneration could be linked to the abnormal positioning of the fovea outside the lunate surface during various daily motions. We introduce the "fossa-foveolar mismatch" (FFM) by determining the trajectory of the fovea in the fossa during hip motions, enabling a comparison across diverse hip-pathomorphologies. AIMS: to determine (1) intraobserver reliability and (2) interobserver reproducibility of our computer-assisted 3-dimensional (3D) model of the FFM. MATERIALS AND METHODS: All patients with joint preserving surgery for femoroacetabular impingement syndrome (FAIS) or developmental dysplasia of the hip (DDH) at our institution (11. 2015-08.2019)were initially eligible. We employed a simple random sampling technique to select 15 patients for analysis. Three-dimensional surface models based on preoperative computed tomography (CT) scans were built, the fossa virtually excised, the fovea capitis marked. Models were subjected to physiological range of motion with validated 3D collision detection software. Using a standardized medial view on the resected fossa and the transparent lunate surface, the FFM-index was calculated for 17 motions. It was obtained by dividing the surface occupied by the fovea outside of the fossa by the total foveolar tracking surface. Three observers independently performed all analyses twice. (1) Intraobserver reliability and (2) interobserver reproducibility were calculated using intraclass correlation coefficients (ICCs). RESULTS: (1) We obtained excellent intraobserver ICCs for the FFM-index averaging 0.92 with 95% CI 0.77-0.9 among the three raters for all motions. (2) Interobserver reproducibility between raters was good to excellent, ranging from 0.76 to 0.98. CONCLUSIONS: The FFM-index showed excellent intraobserver reliability and interobserver reproducibility for all motions. This innovative approach deepens our understanding of biomechanical implications, providing valuable insights for identifying patient populations at risk.

6.
JRSM Cardiovasc Dis ; 13: 20480040241274521, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39314833

RESUMEN

Cardiac catheterization for congenital heart disease (CHD) performed under fluoroscopic guidance still lacks definition and requires exposure to ionizing radiation and contrast agents, with most patients needing multiple procedures through their lifetime, leading to cumulative radiation risks. While fusion overlay techniques have been employed in the past to aid, these have been limited to a single plane, while interventions are traditionally performed under biplane fluoroscopy. We describe our initial experience performing cardiac catheterizations guided by an enhanced biplane GuideCCI system© (Siemens Healthcare, Germany) augmented by 3D magnetic resonance imaging and computed tomography modeling. Twenty-one children and young adults with CHD undergoing catheterization procedures between October 2019 and May 2021 were chosen based on their degree of complexity of cardiac anatomy. 3D stereolithography models were generated, overlayed, and displayed in real time, alongside angiographs in both planes on the screen during these procedures. We report successful implementation of this novel technology for performance of 26 interventions including stent placements, balloon dilations, vessel occlusion and percutaneous valve and transvenous pacemaker implantation all in patients with various complex cardiac anatomies. A statistically significant reduction in radiation and contrast use was noted for coarctation of the aorta stent angioplasty and transcatheter pulmonary valve replacement when compared with national benchmarks and local institutional metrics (with and without single plane overlay). No complications were encountered with the use of this technology. Use of a tracheal registration technique provided very good correlation in most cases. Operators preferred using biplane augmented catheterization over traditional fluoroscopy in patients with complex cardiac anatomy undergoing interventions.

7.
Global Spine J ; : 21925682241278323, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39166967

RESUMEN

STUDY DESIGN: Survey study. OBJECTIVES: The purpose of this study was to characterize the utility of 3D printed patient specific anatomic models for the planning of complex primary spine tumor surgeries. METHODS: A survey of individual members of an international study group of spinal oncology surgeons was performed. Participants were provided a clinical vignette, pathologic diagnosis, and pre-operative imaging for three primary spinal oncology cases. Study participants provided a free text surgical plan for resection and were then presented an associated 3D printed model for each case and asked to re-evaluate their surgical plan. RESULTS: Ten spinal oncology surgeons participated in the study, representing nine institutions across five countries. Four of the surgeons (40%) made significant changes to their surgical plan after reviewing the 3D models, including sacrifice of an additional nerve root to obtain negative margins, sparing an SI joint that was originally planned for inclusion in the en bloc resection, adjusting the location of osteotomy cuts, changes to the number of surgical stages and/or staging order, and preservation of neurology that was originally planned for sacrifice. The overall impression of the 3D models was positive, with 90% of the participants stating they found the 3D model useful in developing a surgical plan. CONCLUSIONS: Surgical planning for resection of primary spinal column tumors is challenging and time intensive. 3D printed patient specific surgical models may be an additional tool that can augment surgical planning and execution by improving the chance of accomplishing surgical resection goals and minimizing morbidity.

8.
Front Endocrinol (Lausanne) ; 15: 1359052, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39157681

RESUMEN

Introduction: Changes to bone physiology play a central role in the development of osteoarthritis with the mechanosensing osteocyte releasing factors that drive disease progression. This study developed a humanised in vitro model to detect osteocyte responses to either interleukin-6, a driver of degeneration and bone remodelling in animal and human joint injury, or mechanical loading, to mimic osteoarthritis stimuli in joints. Methods: Human MSC cells (Y201) were differentiated in 3-dimensional type I collagen gels in osteogenic media and osteocyte phenotype assessed by RTqPCR and immunostaining. Gels were subjected to a single pathophysiological load or stimulated with interleukin-6 with unloaded or unstimulated cells as controls. RNA was extracted 1-hour post-load and assessed by RNAseq. Markers of pain, bone remodelling, and inflammation were quantified by RT-qPCR and ELISA. Results: Y201 cells embedded within 3D collagen gels assumed dendritic morphology and expressed mature osteocytes markers. Mechanical loading of the osteocyte model regulated 7564 genes (Padj p<0.05, 3026 down, 4538 up). 93% of the osteocyte transcriptome signature was expressed in the model with 38% of these genes mechanically regulated. Mechanically loaded osteocytes regulated 26% of gene ontology pathways linked to OA pain, 40% reflecting bone remodelling and 27% representing inflammation. Load regulated genes associated with osteopetrosis, osteoporosis and osteoarthritis. 42% of effector genes in a genome-wide association study meta-analysis were mechanically regulated by osteocytes with 10 genes representing potential druggable targets. Interleukin-6 stimulation of osteocytes at concentrations reported in human synovial fluids from patients with OA or following knee injury, regulated similar readouts to mechanical loading including markers of pain, bone remodelling, and inflammation. Discussion: We have developed a reproducible model of human osteocyte like cells that express >90% of the genes in the osteocyte transcriptome signature. Mechanical loading and inflammatory stimulation regulated genes and proteins implicated in osteoarthritis symptoms of pain as well as inflammation and degeneration underlying disease progression. Nearly half of the genes classified as 'effectors' in GWAS were mechanically regulated in this model. This model will be useful in identifying new mechanisms underlying bone and joint pathologies and testing drugs targeting those mechanisms.


Asunto(s)
Inflamación , Células Madre Mesenquimatosas , Osteoartritis , Osteocitos , Humanos , Osteocitos/metabolismo , Osteocitos/patología , Osteoartritis/patología , Osteoartritis/metabolismo , Inflamación/patología , Inflamación/metabolismo , Células Madre Mesenquimatosas/metabolismo , Células Madre Mesenquimatosas/patología , Interleucina-6/metabolismo , Remodelación Ósea , Células Cultivadas , Diferenciación Celular
9.
Artículo en Inglés | MEDLINE | ID: mdl-39193794

RESUMEN

Bronchopulmonary sequestration is a congenital abnormality characterized by non-functioning lung tissue, abnormal connection with the tracheobronchial tree and anomalous systemic arterial supply. Although considered a rare phenomenon presenting early in life, sequestration may also present with recurrent chest infections in late adulthood. Additionally, bronchopulmonary sequestration may rarely be incidentally encountered during thoracic surgery. Several subtypes exist including intralobar, extralobar and hybrid bronchopulmonary sequestration (congenital pulmonary artery malformation). Surgical resection is curative and serves as the treatment of choice for symptomatic patients. Radiological imaging prior to surgery is essential in these patients because the arterial supply may be anatomically complex, and aberrant artery branches are common. Utilization of virtual 3-dimensional remodelling and computed tomography reconstruction imaging can not only establish a diagnosis of bronchopulmonary sequestration but can also optimize preoperative planning. This approach will ultimately prove useful in anticipating surgically challenging steps and avoiding unnecessary intraoperative complications. We present a video tutorial on the role of 3-dimensional reconstruction imaging in bronchopulmonary sequestration and a step-by-step guide for performing a right robotic-assisted surgical resection of an S2 hybrid bronchopulmonary sequestrated segment. This case is followed by a second case of intralobar bronchopulmonary sequestration encountered incidentally during thoracic surgery.


Asunto(s)
Secuestro Broncopulmonar , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Humanos , Secuestro Broncopulmonar/cirugía , Secuestro Broncopulmonar/diagnóstico , Secuestro Broncopulmonar/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Masculino , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Neumonectomía/métodos
10.
Pediatr Blood Cancer ; : e31241, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101518

RESUMEN

Surgery is a crucial component of pediatric cancer treatment, but conventional methods may lack precision. Image-guided surgery, including fluorescent and radioguided techniques, offers promise for enhancing tumor localization and facilitating precise resection. Intraoperative molecular imaging utilizes agents like indocyanine green to direct surgeons to occult deposits of tumor and to delineate tumor margins. Next-generation agents target tumors directly to improve specificity. Radioguided surgery, employing tracers like metaiodobenzylguanidine (MIBG), complements fluorescent techniques by allowing for detection of tumors at a greater depth. Dual-labeled agents combining both modalities are under development. Three-dimensional modeling and virtual/augmented reality aid in preoperative planning and intraoperative guidance. The above techniques show great promise to benefit patients with pediatric tumors, and their continued development will almost certainly improve surgical outcomes.

11.
Knee ; 50: 41-58, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39116664

RESUMEN

PURPOSE: A personalized model of the knee joint, with adjustable effective geometric parameters for the transplanted autograft diameter in Anterior Cruciate Ligament Reconstruction (ACLR) using the bone-patella-tendon-bone (BPTB) technique, has been developed. The model will assist researchers in understanding how different graft sizes impact a patient's recovery over time. METHODS: The study involved selecting a group of individuals without knee injuries and one patient who had undergone knee surgery. Gait analysis was conducted on the control group and the patient at various time points. A 3D model of the knee joint was created using medical images of the patient. Forces and torques obtained from the gait analysis were applied to the model to perform finite element analysis. RESULTS: The results of the finite element (FE) analysis, along with kinetic data from both groups, indicate that models with diameters of 7.5 mm and 12 mm improved joint motion during follow-up after ACLR. Additionally, a comparison of the stress applied to the ACL model revealed that a 12 mm autograft diameter showed a more favorable trend in patient recovery during the three follow-up intervals after ACL reconstruction surgery. CONCLUSION: The development of a personalized parametric model with adjustable geometric parameters in ACLR, such as the transplanted autograft diameter, as presented in this study, along with FE using the patient's kinetic data, allows for the examination and selection of an appropriate autograft diameter for Patella Tendon grafting. This can help reduce stress on the autograft and prevent damage to other knee joint tissues after ACLR.

12.
Sensors (Basel) ; 24(15)2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39123975

RESUMEN

This paper presents computer and color vision research focusing on human color perception in VR environments. A VR art gallery with digital twins of original artworks is created for this experiment. In this research, the field of colorimetry and the application of the L*a*b* and RGB color models are applied. The inter-relationships of the two color models are applied to create a color modification of the VR art gallery environment using C# Script procedures. This color-edited VR environment works with a smooth change in color tone in a given time interval. At the same time, a sudden change in the color of the RGB environment is defined in this interval. This experiment aims to record a user's reaction embedded in a VR environment and the effect of color changes on human perception in a VR environment. This research uses lie detector sensors that record the physiological changes of the user embedded in VR. Five sensors are used to record the signal. An experiment on the influence of the user's color perception in a VR environment using lie detector sensors has never been conducted. This research defines the basic methodology for analyzing and evaluating the recorded signals from the lie detector. The presented text thus provides a basis for further research in the field of colors and human color vision in a VR environment and lays an objective basis for use in many scientific and commercial areas.

13.
Int J Colorectal Dis ; 39(1): 127, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39107626

RESUMEN

BACKGROUND: The utilization of three-dimensional printing has grown rapidly within the field of surgery over recent years. Within the subspecialty of colorectal surgery, the technology has been used to create personalized anatomical models for preoperative planning, models for surgical training, and occasionally customized implantable devices and surgical instruments. We aim to provide a systematic review of the current literature discussing clinical applications of three-dimensional printing in colorectal surgery. METHODS: Full-text studies published in English which described the application of 3D printing in pre-surgical planning, advanced surgical planning, and patient education within the field of colorectal surgery were included. Exclusion criteria were duplicate articles, review papers, studies exclusively dealing with surgical training and/or education, studies which used only virtual models, and studies which described colorectal cancer only as it pertained to other organs. RESULTS: Eighteen studies were included in this review. There were two randomized controlled trials, one retrospective outcomes study, five case reports/series, one animal model, and nine technical notes/feasibility studies. There were three studies on advanced surgical planning/device manufacturing, six on pre-surgical planning, two on pelvic anatomy modeling, eight on various types of anatomy modeling, and one on patient education. CONCLUSIONS: While more studies with a higher level of evidence are needed, the findings of this review suggest many promising applications of three-dimensional printing within the field of colorectal surgery with the potential to improve patient outcomes and experiences.


Asunto(s)
Cirugía Colorrectal , Impresión Tridimensional , Humanos , Cirugía Colorrectal/educación , Modelos Anatómicos , Animales
14.
JACC Adv ; 3(7): 101057, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39129987

RESUMEN

Background: Single ventricle (SV) patients with interrupted inferior vena cava (iIVC) and azygos continuation are at high risk for unbalanced hepatic venous flow (HVF) distribution to the lungs after Fontan completion and subsequent pulmonary arteriovenous malformations (AVMs) formation. Objectives: The aim of the study was to utilize computational fluid dynamics (CFD) analysis to avoid maldistribution of HVF to the lungs after Fontan surgery. Methods: Four SV subjects with iIVC were prospectively studied with a 3-dimensional (3D) modeling workflow with digital 3D models created from segmented magnetic resonance images or computer tomography scans, virtual surgery, and CFD analysis over multiple physiologic states for the evaluation of operative plans to achieve balanced HVF to both lungs. Three of the patients were Fontan revision candidates with existing AVMs. All patients underwent Fontan completion or revision surgery. Results: CFD predicted that existing or proposed Fontan completion in all patients would result in 100% of HVF to one lung. Improved HVF balance was achieved with CFD analysis of alternative surgical approaches resulting in the average distribution of HVF to the right/left pulmonary arteries of 37%/63% ± 10.4%. A hepatoazygos shunt was required in all patients and additional creation of an innominate vein in one. CFD analysis was validated by the comparison of pre-operative predicted and postoperative MRI-measured total right/left pulmonary flow (51%/49% ± 5.4% vs 49%/51% ± 8.5%). Conclusions: A 3D modeling workflow with CFD simulation for SV patients with iIVC may avoid HVF maldistribution and development of AVMs after Fontan completion.

15.
Int J Legal Med ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38970679

RESUMEN

Photogrammetry is a technique for studying and defining objects' shape, dimension, and position in a three-dimensional space using measurements obtained from two-dimensional photographs. It has gained popularity following the development of computer graphics technologies and has been applied to various branches of medicine. In this study, the authors present a method for low-cost photorealistic documentation of corpses during autopsy using single-camera photogrammetry with a mobile phone. Besides representing the body by demonstrating the injured and non-injured body parts as control, evidencing the body parts on a 3D reconstruction allows easy explanation to nonmedical experts such as lawyers.

16.
Heliyon ; 10(12): e33017, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39021946

RESUMEN

The complex iron oxide copper and gold (IOCG) Sin Quyen deposit in northern Vietnam is known as hydrothermal veins and multi-stages of mineralization. Thus, it is complicated to make a probabilistic 3D geometric model using traditional methods and to predict the hidden mineral potential. In this study, computer modeling with nearly 8000 archival data was recorded from 146 boreholes within the study area, and the chemical analysis was done on 40 samples. The 3D block model was constructed using geological structure, optimal parameters, and computational tools approach to the 3D geometric models of surface and ore bodies distribution. The Cu and Ag reserves were estimated based on the 3D geometric models. The total reserve of all ore bodies at the current depth was recorded at 540000 and 25 tons for Cu and Ag, respectively. In the study area, almost all ore bodies were observed as hydrothermal vein types, extending in Northwest-Southeast strikes and dipping around 750 m, closest to the geological observation. The mineralization characteristics of the study area are controlled by left-lateral zipper tectonic activity and faults. Based on tectonic and the 3D geometric model characteristics, the Cu ore bodies are trending continuously to more than 300 m depth at the Southeast of Ngoi Phat stream, while the Northwest shows no signs.

17.
Urologia ; : 3915603241261499, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058231

RESUMEN

OBJECTIVE: To assess the correlation between the general (gender, age, and maximum tumor size) and 3D morphotopometric features of the renal tumor node, following the MSCT data post-processing, and the tumor histological structure; to propose an equation allowing for kidney malignancy assessment based on general and morphometric features. MATERIALS AND METHODS: In total, 304 patients with unilateral solitary renal neoplasms underwent laparoscopic (retroperitoneoscopic) or robotic partial or radical nephrectomy. Before the procedure, kidney contrast-enhanced MSCT followed by the tumor 3D-modeling was performed. 3D model of the kidney tumor, and its morphotopometric features, and histological structure were analyzed. The morphotopometric ones include the side of the lesion, location by segments, the surface where the tumor, the depth of the tumor invasion into the kidney, and the shape of tumor. RESULTS: Out of 304 patients, 254 (83.6%) had malignant kidney tumors and 50 (16.4%) benign kidney tumors. In total, 231 patients, out of 254 (90.9%) were assessed for the degree of malignant tumor differentiation. Malignant tumors were more frequent in men than in women (p < 0.001). Mushroom-shaped tumors were the most common shapes among benign renal masses (35.2%). The most common malignant kidney tumors had spherical with a partially uneven surface (27.6%), multinodular (tuberous (27.2%)), and spherical with a conical base (24.8%) shapes. Logistic regression model enabled the development of prognostic equation for tumor malignancy prediction ("low" or "high"). The univariate analysis revealed the correlation only between high differentiation (G1) and a spherical tumor with a conical base (p = 0.029). CONCLUSION: The resulting logistic model, based on the analysis of such predictors as gender and form of kidney lesions, demonstrated a large share (87.6%) of correct predictions of the kidney tumor malignancy.

18.
Front Surg ; 11: 1427844, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39081485

RESUMEN

Recent advances in medical imaging, computer vision, 3-dimensional (3D) modeling, and artificial intelligence (AI) integrated technologies paved the way for generating patient-specific, realistic 3D visualization of pathological anatomy in neurosurgical conditions. Immersive surgical simulations through augmented reality (AR), virtual reality (VR), mixed reality (MxR), extended reality (XR), and 3D printing applications further increased their utilization in current surgical practice and training. This narrative review investigates state-of-the-art studies, the limitations of these technologies, and future directions for them in the field of skull base surgery. We begin with a methodology summary to create accurate 3D models customized for each patient by combining several imaging modalities. Then, we explore how these models are employed in surgical planning simulations and real-time navigation systems in surgical procedures involving the anterior, middle, and posterior cranial skull bases, including endoscopic and open microsurgical operations. We also evaluate their influence on surgical decision-making, performance, and education. Accumulating evidence demonstrates that these technologies can enhance the visibility of the neuroanatomical structures situated at the cranial base and assist surgeons in preoperative planning and intraoperative navigation, thus showing great potential to improve surgical results and reduce complications. Maximum effectiveness can be achieved in approach selection, patient positioning, craniotomy placement, anti-target avoidance, and comprehension of spatial interrelationships of neurovascular structures. Finally, we present the obstacles and possible future paths for the broader implementation of these groundbreaking methods in neurosurgery, highlighting the importance of ongoing technological advancements and interdisciplinary collaboration to improve the accuracy and usefulness of 3D visualization and reality technologies in skull base surgeries.

19.
Front Microbiol ; 15: 1429179, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39081890

RESUMEN

The community structure and ecological function of marine ecosystems are critically dependent on phytoplankton. However, our understanding of phytoplankton is limited due to the lack of detailed information on their morphology. To address this gap, we developed a framework that combines scanning electron microscopy (SEM) with photogrammetry to create realistic 3D (three-dimensional) models of phytoplankton. The workflow of this framework is demonstrated using two marine algal species, one dinoflagellate Prorocentrum micans and one diatom Halamphora sp. The resulting 3D models are made openly available and allow users to interact with phytoplankton and their complex structures virtually (digitally) and tangibly (3D printing). They also allow for surface area and biovolume calculations of phytoplankton, as well as the exploration of their light scattering properties, which are both important for ecosystem modeling. Additionally, by presenting these models to the public, it bridges the gap between scientific inquiry and education, promoting broader awareness on the importance of phytoplankton.

20.
Cancers (Basel) ; 16(14)2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39061220

RESUMEN

INTRODUCTION: Decellularized extracellular matrix (ECM) bioscaffolds have emerged as a promising three-dimensional (3D) model, but so far there are no data concerning their use in radiobiological studies. MATERIAL AND METHODS: We seeded two well-known radioresistant cell lines (HMV-II and PANC-1) in decellularized porcine liver-derived scaffolds and irradiated them with both high- (Carbon Ions) and low- (Photons) Linear Energy Transfer (LET) radiation in order to test whether a natural 3D-bioscaffold might be a useful tool for radiobiological research and to achieve an evaluation that could be as near as possible to what happens in vivo. RESULTS: Biological scaffolds provided a favorable 3D environment for cell proliferation and expansion. Cells did not show signs of dedifferentiation and retained their distinct phenotype coherently with their anatomopathological and clinical behaviors. The radiobiological response to high LET was higher for HMV-II and PANC-1 compared to the low LET. In particular, Carbon Ions reduced the melanogenesis in HMV-II and induced more cytopathic effects and the substantial cell deterioration of both cell lines compared to photons. CONCLUSIONS: In addition to offering a suitable 3D model for radiobiological research and an appropriate setting for preclinical oncological analysis, we can attest that bioscaffolds seemed cost-effective due to their ease of use, low maintenance requirements, and lack of complex technology.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA