Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Luminescence ; 27(1): 34-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-21674749

RESUMEN

The adenosine triphosphate (ATP) bioluminescence rapid determination method may be useful for enumerating the total viable count (TVC) in soy sauce, as it has been previously used in food and beverages for sanitation with good precision. However, many factors interfere with the correlation between total aerobic plate counts and ATP bioluminescence. This study investigated these interfering factors, including ingredients of soy sauce and bacteria at different physiological stages. Using the ATP bioluminescence method, TVC was obtained within 4 h, compared to 48 h required for the conventional aerobic plate count (APC) method. Our results also indicated a high correlation coefficient (r = 0.90) between total aerobic plate counts and ATP bioluminescence after filtration and resuscitation with special medium. The limit of quantification of the novel detection method is 100 CFU/mL; there is a good linear correlation between the bioluminescence intensity and TVC in soy sauce in the range 1 × 10(2) -3 × 10(4) CFU/mL and even wider. The method employed a luminescence recorder (Tristar LB-941) and 96-well plates and could analyse 50-100 samples simultaneously at low cost. In this study, we evaluated and eliminated the interfering factors and made the ATP bioluminescence rapid method available for enumerating TVC in soy sauce.


Asunto(s)
Mediciones Luminiscentes , Alimentos de Soja/microbiología , Adenosina Trifosfato , Bacterias/citología , Recuento de Colonia Microbiana , Límite de Detección
2.
Int J Food Sci Nutr ; 60(5): 432-8, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22519678

RESUMEN

A novel method was developed to analyze lotus rhizome polyphenolic catechin using high-performance liquid chromatography (HPLC). The retain time of catechin was 14.72 min under the optimized condition. Mass spectrometry was further employed to qualify and quantify the purity of the catechin peak. Good linearity (R=0.9997) was obtained within the range of 50-1,000 ng. The coefficient of variance was determined as 5.2%, with a recovery rate of 97%. The detection and quantification limitations of catechin were 23 ng and 50 ng, respectively. The catechin level was 0.0025% in the lotus rhizome, and 0.011% in the knot of the lotus rhizome (Nelumbo nucifera cv. 'damao jie'). The optimized conditions of HPLC for catechin detection in the lotus rhizome matrix were as follows: the SuperlcosIL™ LC-18 analytical column (150 mm×4.6 mm, 5 µm), methanol-water-acetic acid (10:90:1, volume ratio) as the mobile phase, an UV detector at 280 nm, a flow rate of 0.8 ml/min, column temperature at 30°C, and an injection volume of 10 µl.


Asunto(s)
Antioxidantes/análisis , Catequina/análisis , Cromatografía Líquida de Alta Presión/métodos , Nelumbo/química , Extractos Vegetales/química , Rizoma/química , Espectrometría de Masas/métodos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA