Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 349
Filtrar
1.
Diagnostics (Basel) ; 14(17)2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39272719

RESUMEN

BACKGROUND AND AIMS: The aim of this study was to investigate the possible preanalytical effect of incomplete filling of blood tubes on molecular biology assays. MATERIALS AND METHODS: The study population consisted of 13 healthy volunteers from whom 11 mL of whole blood was collected and then distributed in different volumes (1.5, 3.0, and 6.0 mL, respectively) into three 6.0 mL spray-dried and evacuated K2EDTA blood tubes. Automated RNA extraction was performed using the Maxwell® CSC RNA Blood Kit. DNA was extracted with a MagCorePlusII, with concomitant measurement of glyceralde-hyde-3-phosphate dehydrogenase (GAPDH) gene expression. The nucleic acid concentration was calculated using the NanoDrop 1000 spectrophotometer, and purity was assessed using A260/280 and A260/230 absorbance ratios. RESULTS: The RNA concentration was higher in the tubes filled with 1.5 and 3.0 mL of blood than in the reference 6 mL filled tube. The RNA 260/280 and RNA 260/230 ratios did not differ significantly between the differently filled blood tubes. The DNA concentration remained constant in the differently filled tubes. Compared to the 6.0 mL reference filled tube, the 1.5 mL and 3.0 mL filled blood tubes displayed a lower DNA 260/280 nm ratio. The DNA 260/230 ratio did not differ significantly in any of the variously filled tubes. Compared to the 6.0 mL reference filled blood tube, the 1.5 mL and 3.0 mL filled blood tubes showed a significant increase in the GAPDHcycle threshold. CONCLUSIONS: Our results suggest that underfilling of K2EDTA blood tubes may be a modest but analytically significant source of bias in molecular biology testing.

3.
Biomed J ; : 100787, 2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39251135

RESUMEN

We planned a series of experiments to investigate the possible role of spike protein of different SARS-CoV-2 variants in influencing erythrocyte biology. The values of erythrocyte count, hemoglobin, and mean corpuscular hemoglobin (MHC) did not vary across all samples challenged with both concentrations of the four different SARS-CoV-2 recombinant spike proteins. A significant increase in mean corpuscular volume (MCV) was observed with the recombinant SARS-CoV-2 Alpha and Delta spike proteins at both 2 and 20 ng/mL final concentrations. Red blood cell distribution width (RDW) values increased significantly in samples treated with 20 ng/mL of all SARS-CoV-2 recombinant spike proteins and reached the highest values in samples treated with Omicron recombinant spike protein. Blood smear revision evidenced hemagglutination and rouleaux in samples to which recombinant SARS-CoV-2 spike proteins were added, especially in those with Alpha and Delta variants.

4.
Adv Lab Med ; 5(3): 301-306, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39252807

RESUMEN

Objectives: The purpose of this study was to investigate the effects of contamination of venous blood with a lipid-containing solution on parameters measured by a modern blood gas analyzer. Methods: We collected venous blood from 17 healthcare workers (46 ± 11 years; 53 % women) into three blood gas syringes containing 0 , 5 and 10 % lipid-containing solution. Blood gas analysis was performed within 15 min from sample collection on GEM Premier 5000, while triglycerides and serum indices were assays on Roche COBAS C702. Results: Triglycerides concentration increased from 1.0 ± 0.3 mmol/L in the uncontaminated blood gas syringe, to 39.4 ± 7.8 and 65.3 ± 14.4 mmol/L (both p<0.001) in syringes with 5 and 10 % final lipid contamination. The lipemic and hemolysis indices increased accordingly. Statistically significant variation was noted for all analytes except hematocrit and COHb in the syringe with 5 % lipids, while only COHb did not vary in the syringe with 10 % lipids. Significant increases were observed from 5 % lipid contamination for pO2, SO2 and lactate, while the values of pH, pCO2, sodium, potassium, chloride, ionized calcium, glucose, hematocrit (10 % contamination), hemoglobin and MetHB decreased. All these changes except lactate and CoHb exceeded their relative performance specifications. Conclusions: Artifactual hyperlipidemia caused by contamination with exogenous lipids can have a clinically significant impact on blood gas analysis. Manufacturers of blood gas analyzers must be persuaded to develop new instruments equipped with serum indices.

6.
Clin Chem Lab Med ; 62(7): 1433-1437, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38176023

RESUMEN

OBJECTIVES: The current study was designed to evaluate the analytical performance of the new Mindray highly sensitive cardiac troponin I (hs-cTnI) chemiluminescent immunoassay on Mindray CL-1200i, as a thorough validation of novel hs-cTnI methods is required before introduction into clinical practice. METHODS: The evaluation of the analytical performance of this hs-cTnI immunoassay encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, imprecision, linearity, 99th percentile upper reference limit (URL) and concordance with another previously validated hs-cTnI chemiluminescent immunoassay. RESULTS: The LOB and LOD were 0.32 and 0.35 ng/L, whilst the functional sensitivity (expressed as cTnI value with <10 % imprecision), was 0.35 ng/L. The linearity was excellent throughout a wide range of clinically measurable values (r=1.00 between 0.8 and 9,726.9 ng/mL). The intra-assay, inter-assay and total imprecision were 1.1-1.3 %, 5.5-8.1 % and 5.6-8.2 %, respectively. The 99th percentile URL calculated using residual plasma from 246 ostensibly healthy blood donors was 9.2 ng/L (4.3 ng/L in women vs. 12.3 ng/L in men). The Spearman's correlation between Mindray hs-cTnI and Access hs-TnI was 0.97, with mean bias of 7.2 % (95 % CI, 2.6-11.9 %). CONCLUSIONS: Although we failed to confirm the very optimistic analytical characteristics previously reported for this method, our evaluation of the novel Mindray hs-cTnI immunoassay on CL-1200i demonstrated that the overall performance is comparable to that of other commercially available hs-cTnI techniques, making it a viable alternative to other methods.


Asunto(s)
Límite de Detección , Troponina I , Humanos , Troponina I/sangre , Troponina I/análisis , Inmunoensayo/métodos , Inmunoensayo/normas , Femenino , Masculino , Adulto , Persona de Mediana Edad , Mediciones Luminiscentes/métodos , Mediciones Luminiscentes/normas , Anciano , Reproducibilidad de los Resultados , Valores de Referencia
8.
Diagnosis (Berl) ; 11(1): 91-96, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37665244

RESUMEN

OBJECTIVES: There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis. METHODS: Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume. RESULTS: The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood. CONCLUSIONS: Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.


Asunto(s)
Ácido Láctico , Jeringas , Humanos , Análisis de los Gases de la Sangre/métodos , Sodio , Hemoglobinas
9.
Semin Thromb Hemost ; 50(2): 275-283, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37327884

RESUMEN

Platelets are central elements of hemostasis and also play a pivotal role in the pathogenesis of thrombosis in coronavirus disease 2019. This study was planned to investigate the effects of different severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) recombinant spike protein variants on platelet morphology and activation. Citrated whole blood collected from ostensibly healthy subjects was challenged with saline (control sample) and with 2 and 20 ng/mL final concentration of SARS-CoV-2 recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Platelet count was found to be decreased with all SARS-CoV-2 recombinant spike protein variants and concentrations tested, achieving the lowest values with 20 ng/mL Delta recombinant spike protein. The mean platelet volume increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, but especially using Delta and Alpha recombinant spike proteins. The values of both platelet function analyzer-200 collagen-adenosine diphosphate and collagen-epinephrine increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, and thus reflecting platelet exhaustion, and displaying again higher increases with Delta and Alpha recombinant spike proteins. Most samples where SARS-CoV-2 recombinant spike proteins were added were flagged as containing platelet clumps. Morphological analysis revealed the presence of a considerable number of activated platelets, platelet clumps, platelet-monocyte, and platelet-neutrophils aggregates, especially in samples spiked with Alpha and Delta recombinant spike proteins at 20 ng/mL. These results provide support to the evidence that SARS-CoV-2 is capable of activating platelets through its spike protein, though such effect varies depending on different spike protein variants.


Asunto(s)
COVID-19 , Glicoproteína de la Espiga del Coronavirus , Humanos , SARS-CoV-2 , Colágeno
11.
Chronobiol Int ; 41(2): 309-310, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38148565

RESUMEN

We measured total anti-SARS-CoV-2 receptor-biding domain (RBD) antibodies in 249 healthcare workers (mean age: 44 ± 13 years; 151 women), who received the first dose of mRNA-based Comirnaty COVID-19 vaccine at different times of the day. Compared with the reference vaccination time point (i.e. <10:00h), vaccine injection at the following times of day elicited a comparable response (all p > 0.05). Under our experimental conditions, we can therefore exclude a possible influence of the timing of primary mRNA-based COVID-19 vaccination on the levels of total anti-SARS-CoV-2 antibodies.


Asunto(s)
COVID-19 , Humanos , Femenino , Adulto , Persona de Mediana Edad , Vacunas contra la COVID-19 , Ritmo Circadiano , Vacunación , ARN Mensajero
14.
Adv Lab Med ; 4(2): 175-184, 2023 Jun.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38075941

RESUMEN

Objectives: We planned this study to verify whether immunoassays for quantifying anti-SARS-CoV-2 IgG/IgM antibodies against both spike (S) and nucleocapsid (N) proteins may be used for identifying previous SARS-CoV-2 infections. Methods: The study population consisted of a cohort of fully vaccinated healthcare workers. All study subjects underwent regular medical visits and molecular testing for diagnosing SARS-CoV-2 infections every 2-4 weeks between 2020-2022. Venous blood was drawn for measuring anti-SARS-CoV-2 antibodies with MAGLUMI 2019-nCoV lgG/IgM CLIA Assays directed against both SARS-CoV-2 S and N proteins. Results: Overall, 31/53 (58.5%) subjects had tested positive for SARS-CoV-2 by RT-PCR throughout the study (24 once, 7 twice). No positive correlation was found between anti-SARS-CoV-2 S/N IgM antibodies and molecular test positivity. In univariate regression analysis, both a molecular test positivity (r=0.33; p=0.015) and the number of positive molecular tests (r=0.43; p=0.001), but not vaccine doses (r=-0.12; p=0.392), were significantly correlated with anti-SARS-CoV-2 S/N IgG antibodies. These two associations remained significant in multiple linear regression analysis (p=0.029 and p<0.001, respectively) after adjusting for sex, age, body mass index, and vaccine doses. In ROC curve analysis, anti-SARS-CoV-2 S/N IgG antibodies significantly predicted molecular test positivity (AUC, 0.69; 95% CI; 0.55-0.84), with the best cutoff of 0.05 AU/mL displaying 67.9% accuracy, 0.97 sensitivity, and 0.27 specificity. Conclusions: Although anti-SARS-CoV-2 S/N IgG antibodies provide helpful information for identifying previous SARS-CoV-2 infections, a lower cutoff than that of sample reactivity should be used. Anti-SARS-CoV-2 S/N IgM antibodies using conventional cutoffs seem useless for this purpose.

16.
Adv Lab Med ; 4(4): 431-434, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38106501

RESUMEN

Objectives: The purpose of this proof-of-concept study was to investigate whether a commercially available urine dipstick may provide potentially useful information for screening plasma glucose and bilirubin in human plasma samples. Methods: Glucose and bilirubin were assayed in 60 anonymized lithium-heparin residual plasma samples using the Roche COBAS 8000 or after pipetting 10 µL of plasma onto the pads of a commercial urine dipstick. Semiquantitative urine test results obtained with the dipstick were directly compared to paired test results obtained with COBAS. Results: Median plasma glucose values between COBAS and dipstick were slightly different (5.8 vs. 5.6 mmol/L; p=0.040), while no significant difference was found in bilirubin values between COBAS and dipstick (11.2 vs. 8.6 µmol/L; p=0.090). The Spearman's correlation between COBAS and dipstick was 0.83 (95% CI, 0.73-0.90; p<0.001) for plasma glucose and 0.78 (95% CI, 0.66-0.87; p<0.001) for plasma bilirubin, respectively. Cumulative agreement between COBAS and dipstick was high for both glucose (88%; kappa statistic statistics, 0.75; 95% CI, 0.58-0.92; p<0.001) and bilirubin (88%; kappa statistics, 0.76; 95% CI, 0.60-0.92; p<0.001). Conclusions: The results of this proof-of-concept study indicate that the commercial urine test strip used in our study provides acceptable performance for screening plasma glucose and bilirubin levels compared with reference laboratory assays.

17.
Int J Mol Sci ; 24(16)2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37628976

RESUMEN

Studies investigating the potential role of circulating bile acids (BAs) as diagnostic biomarkers for cholangiocarcinoma (CCA) are sparse and existing data do not adjust for confounding variables. Furthermore, the mechanism by which BAs affect the expression of the oncogenic mucin 5AC (MUC5AC) has never been investigated. We performed a case-control study to characterise the profile of circulating BAs in patients with CCA (n = 68) and benign biliary disease (BBD, n = 48) with a validated liquid chromatography-tandem mass spectrometry technique. Odd ratios (OR) for CCA associations were calculated with multivariable logistic regression models based on a directed acyclic graph structure learning algorithm. The most promising BAs were then tested in an in vitro study to investigate their interplay in modulating MUC5AC expression. The total concentration of BAs was markedly higher in patients with CCA compared with BBD controls and accompanied by a shift in BAs profile toward a higher proportion of primary conjugated BAs (OR = 1.50, CI: 1.14 to 1.96, p = 0.003), especially taurochenodeoxycholic acid (TCDCA, OR = 42.29, CI: 3.54 to 504.63, p = 0.003) after multiple adjustments. Western blot analysis of secreted MUC5AC in human primary cholangiocytes treated with primary conjugated BAs or with TCDCA alone allowed us to identify a novel 230 kDa isoform, possibly representing a post-translationally modified MUC5AC specie.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Humanos , Ácidos y Sales Biliares , Mucina 5AC , Estudios de Casos y Controles , Conductos Biliares Intrahepáticos
18.
Diagnosis (Berl) ; 10(4): 440-445, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37480580

RESUMEN

OBJECTIVES: Because there is little published evidence on the effects of incomplete filling of K2EDTA evacuated blood tubes on routine hematological testing, this original study aimed to provide updated information on this preanalytical aspect. METHODS: The study population consisted of 17 ostensibly healthy volunteers. Blood was drawn by venipuncture with a 10 mL syringe and dispensed in varying amounts (0.2, 0.5, 1.0, 2.0, and 3.0 mL) into 3.0 mL blood tubes containing spray-dried 5.4 mg K2EDTA. All tubes were gently mixed and used to perform routine hematology tests on the Sysmex XN-10. Clinically significant variations were defined when the limits of desirable specifications of bias derived from biologic variation were exceeded. RESULTS: The desirable bias was exceeded in 33 % filled tubes (1.0 mL) for hematocrit and MCV (increased values) and for MCHC (decreased values), while it was exceeded in 17 % filled tubes (0.5 mL) for hemoglobin, hematocrit and MCV (increased values), and for MCHC (decreased values). Finally, the variation of values was higher than the desirable bias for RBC, hemoglobin, hematocrit and MCV (increase), and for MCHC and MPV (decrease) in 7 % filled tubes (0.2 mL). No clinically significant variations were observed in tubes filled up to 67 % of their nominal volume (i.e., 2.0 mL). CONCLUSIONS: Consideration should be given to reject spray-dried K2EDTA blood tubes that contain a blood volume <67 % of the nominal fill volume, as biased laboratory data in these samples may interfere with clinical decision making and care management.


Asunto(s)
Anticoagulantes , Hematología , Humanos , Ácido Edético/farmacología , Anticoagulantes/farmacología , Recolección de Muestras de Sangre/métodos , Hemoglobinas
19.
Int J Mol Sci ; 24(11)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37298324

RESUMEN

This study investigated the biological effects on circulating monocytes after challenge with SARS-CoV-2 recombinant spike protein. Whole blood collected from seven ostensibly healthy healthcare workers was incubated for 15 min with 2 and 20 ng/mL final concentration of recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Samples were analyzed with Sysmex XN and DI-60 analyzers. Cellular complexity (i.e., the presence of granules, vacuoles and other cytoplasmic inclusions) increased in all samples challenged with the recombinant spike protein of the Ancestral, Alpha, and Delta variants, but not in those containing Omicron. The cellular content of nucleic acids was constantly decreased in most samples, achieving statistical significance in those containing 20 ng/mL of Alpha and Delta recombinant spike proteins. The heterogeneity of monocyte volumes significantly increased in all samples, achieving statistical significance in those containing 20 ng/mL of recombinant spike protein of the Ancestral, Alpha and Delta variants. The monocyte morphological abnormalities after spike protein challenge included dysmorphia, granulation, intense vacuolization, platelet phagocytosis, development of aberrant nuclei, and cytoplasmic extrusions. The SARS-CoV-2 spike protein triggers important monocyte morphological abnormalities, more evident in cells challenged with recombinant spike protein of the more clinically severe Alpha and Delta variants.


Asunto(s)
COVID-19 , Monocitos , Humanos , Glicoproteína de la Espiga del Coronavirus/genética , SARS-CoV-2
20.
Immunol Res ; 71(5): 717-724, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37171542

RESUMEN

It is well established that neurological and non-neurological autoimmune disorders can be triggered by viral infections. It remains unclear whether SARS-CoV-2 infection induces similar conditions and whether they show a distinctive phenotype. We retrospectively identified patients with acute inflammatory CNS conditions referred to our laboratory for antibody testing during the pandemic (March 1 to August 31, 2020). We screened SARS-COV-2 IgA/IgG in all sera by ELISA and confirmed the positivity with additional assays. Clinical and paraclinical data of SARS-COV-2-IgG seropositive patients were compared to those of seronegative cases matched for clinical phenotype, geographical zone, and timeframe. SARS-CoV-2-IgG positivity was detected in 16/339 (4%) sera, with paired CSF positivity in 3/16. 5 of these patients had atypical demyelinating disorders and 11 autoimmune encephalitis syndromes. 9/16 patients had a previous history of SARS-CoV-2 infection and 6 of them were symptomatic. In comparison with 32 consecutive seronegative controls, SARS-CoV-2-IgG-positive patients were older, frequently presented with encephalopathy, had lower rates of CSF pleocytosis and other neurological autoantibodies, and were less likely to receive immunotherapy. When SARS-CoV-2 seropositive versus seronegative cases with demyelinating disorders were compared no differences were seen. Whereas seropositive encephalitis patients less commonly showed increased CSF cells and protein, our data suggest that an antecedent symptomatic or asymptomatic SARS-CoV-2 infection can be detected in patients with autoimmune neurological conditions. These cases are rare, usually do not have specific neuroglial antibodies.


Asunto(s)
Enfermedades Autoinmunes , COVID-19 , Enfermedades Desmielinizantes , Humanos , Estudios Retrospectivos , SARS-CoV-2 , Anticuerpos Antivirales , Inmunoglobulina G
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA