Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
3.
Cardiovasc Intervent Radiol ; 24(6): 407-12, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11907748

RESUMEN

Intravenous perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles in the presence of low frequency ultrasound (LFUS) can lyse very small clots. We develop a similar method to declot full-size arteriovenous dialysis grafts. Dialysis grafts fashioned in three dogs were cannulated and ligated. After thrombosis, three declotting techniques were randomly applied: 1) direct injection of PESDA + LFUS; 2) direct injection of saline + LFUS; and 3) intravenous PESDA + LFUS. Declotting was graded by cine angiography scores of each third of the graft on a scale of 0-4 (maximum total score = 12). Twenty-six procedures showed mean patency scores of 11.1 for direct PESDA and 8.4 for i.v. PESDA, vs 4.9 for direct saline, p = <0.001. All eight direct PESDA injections achieved lysis and good flow, but none of 8 direct saline injections succeeded, p = <0.01. Intravenous PESDA succeeded in 4 of 10 procedures, p = <0.04 vs saline. Direct injection of PESDA with transcutaneous LFUS succeeds in lysing moderate-size clots and recanalizing thrombosed fistulas.


Asunto(s)
Diálisis/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Ultrasonografía Intervencional/métodos , Animales , Coagulación Sanguínea/efectos de los fármacos , Medios de Contraste/uso terapéutico , Modelos Animales de Enfermedad , Perros , Vena Femoral/diagnóstico por imagen , Vena Femoral/patología , Fluorocarburos/uso terapéutico , Glucosa/uso terapéutico , Inyecciones Intravenosas , Pierna/irrigación sanguínea , Pierna/diagnóstico por imagen , Albúmina Sérica/uso terapéutico , Albúmina Sérica Humana , Trombosis/sangre , Resultado del Tratamiento , Grado de Desobstrucción Vascular/efectos de los fármacos
4.
Cardiovasc Intervent Radiol ; 23(4): 298-300, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10960544

RESUMEN

A patient developed acute severe hemodynamic compromise during a transjugular intrahepatic portosystemic shunt (TIPS) procedure for intractable ascites. Rapid clinical and radiographic evaluation of the patient disclosed pericardial blood and cardiac tamponade as the cause, probably due to right heart perforation from guidewire and catheter manipulation. The tamponade was successfully treated percutaneously, and the patient survived. Cardiac tamponade should be considered in the differential diagnosis of patients who develop hypotension during TIPS placement.


Asunto(s)
Taponamiento Cardíaco/etiología , Lesiones Cardíacas/complicaciones , Complicaciones Intraoperatorias , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/terapia , Ecocardiografía , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/terapia , Ventrículos Cardíacos/lesiones , Humanos , Fallo Hepático/cirugía , Masculino , Persona de Mediana Edad , Flebografía , Radiografía Torácica , Succión
5.
Radiographics ; 20(4): 977-93, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10903688

RESUMEN

Prosthetic graft infections are an uncommon complication of aortic bypass. These infections may have serious sequelae such as limb loss and can be lethal. They are hard to eradicate and, under certain circumstances, difficult to diagnose. Usually, computed tomography (CT) is the most efficacious imaging method for diagnosis of graft infections due to its quick availability. The sensitivity of magnetic resonance imaging in detection of perigraft infection has not been thoroughly investigated but is probably similar to that of CT. After the early postoperative period, persistent or expanding perigraft soft tissue, fluid, and gas are the CT findings of graft infection. Aortoenteric fistula should be considered a subset of aortic graft infection; however, perigraft air is more likely to be seen with an aortoenteric fistula. Other conditions associated with graft infection include pseudoaneurysm, hydronephrosis, and osteomyelitis. Adjunctive studies such as sinography, ultrasonography, gallium scanning, and labeled white blood cell scanning can be quite useful in diagnosis, determination of the extent of disease, and selection of the treatment modality. White blood cell scanning is an important complementary test to CT in ambiguous cases, such as in the early postoperative period, and may be more sensitive in detection of early graft infection.


Asunto(s)
Aorta/cirugía , Prótesis Vascular/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Aire , Aneurisma Falso/etiología , Aneurisma de la Aorta/etiología , Enfermedades de la Aorta/etiología , Exudados y Transudados , Humanos , Hidronefrosis/etiología , Fístula Intestinal/etiología , Imagen por Resonancia Magnética , Osteomielitis/etiología , Infecciones Relacionadas con Prótesis/terapia , Sensibilidad y Especificidad , Fístula Vascular/etiología
6.
J Vasc Interv Radiol ; 11(3): 351-8, 2000 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10735431

RESUMEN

PURPOSE: To use quantitative ultrasonographic measurements to compare the effect of a polymeric coating designed to increase needle echogenicity to commercially available needles. MATERIALS AND METHODS: Commercially available standard smooth and dimpled echogenic tip 21-gauge needles established reference levels of echogenicity in gelatin-based and turkey breast phantoms. Examples of both types of needles were coated with a thin polymeric film that utilizes entrapped microbubbles of air on its surface to increase echogenicity. Samples of each type in both coated and noncoated versions were placed in phantoms in matched positions and imaged with clinical ultrasound machines. Similar numbers of each category were evaluated at various angles of insonation for a total of 109 images. Similar numbers of each category were imaged at 5-minute intervals for up to 38 minutes for a total of 226 images. Images were recorded, digitized, and evaluated for relative echo strength in arbitrary echogenic brightness units. RESULTS: Coating increased peak echogenicity over the entire needle to a level that closely approximates the peak echogenicity of dimpled needle tips (means: dimpled = 834, coated smooth = 803, coated dimpled = 823; P = .54). Smooth is lower than this group at 468 (P = .0001). Representative area echogenicity increased with coating or dimpling (smooth = 377 vs coated smooth = 778, coated dimpled = 690, dimpled = 775; P = .0001). Coating increased peak values 74% and area values 95% compared to smooth. Decreased angles of insonation moderately reduced echogenicity on coated smooth, coated dimpled, and dimpled, while it decreased to below good visibility threshold on standard smooth needles. The echogenicity of the coated needles fades in saline with time (1%/min). CONCLUSION: Objective measurements show that this coating significantly increases echogenicity of entire needles to match that obtained with a dimpled tip.


Asunto(s)
Materiales Biocompatibles Revestidos/normas , Agujas/normas , Polímeros/normas , Ultrasonografía , Animales , Diseño de Equipo , Fantasmas de Imagen , Pavos
7.
Catheter Cardiovasc Interv ; 46(2): 187-92, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10348540

RESUMEN

Children with congenital heart disease present major problems with venous access, eliminating conventional routes for cardiac catheterization. Although the transhepatic approach has recently gained popularity, we describe here an alternative approach using percutaneous translumbar approach for cardiac catheterization and/or in-dwelling central line insertion in three children with congenital heart disease. Diagnostic hemodynamic studies, transcatheter delivery of an intravascular stent for left pulmonary artery (LPA) stenosis, and chronic central venous line insertion were performed using this technique. Disadvantages include interventionalist's unfamiliarity with technique, awkward patient positioning, technically more difficult than transhepatic, and potential injury to kidney and bowel. Advantages include avoidance of vascular-rich hepatic parenchyma, thus reducing risk of hemorrhage; providing an alternative where transhepatic entry may be contraindicated; avoidance of bile duct, portal vein, and hepatic artery injury; and providing another alternative for not only transvenous, but also transarterial access that may be required for intravascular aortic stent delivery. The interventional radiologist should be utilized as a valuable resource to the cardiologist to help teach and supervise this technique in selected infants and children with limited vascular access.


Asunto(s)
Cateterismo Cardíaco/métodos , Cateterismo Venoso Central , Cardiopatías Congénitas/terapia , Niño , Preescolar , Femenino , Humanos , Masculino
10.
J Vasc Interv Radiol ; 9(2): 233-9, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9540905

RESUMEN

PURPOSE: To determine the rate of complications associated with hepatic arterial infusion (HAI) catheter placement, as well as technical success related to liver perfusion. MATERIALS AND METHODS: The authors reviewed 44 patients who underwent 106 HAI catheter placements, including 15 men and 29 women with an average age of 55 years (range, 32-82 years). One to nine placements were performed per patient with 61 (58%) via the left brachial artery, 40 (38%) via the right femoral artery, and five (4%) via the left femoral artery. Chemoinfusion lasted 4 days, with initial catheter placement assessed on technetium-99m macroaggregated albumin (MAA) perfusion scans, as well as daily abdominal radiographs. RESULTS: One hundred attempted hepatic arterial catheter placements were completed. Liver perfusion was global in 66 (66%) cases, in the right lobe only in 28 (28%) cases, and in the left lobe only in six (6%) cases. Eight (8%) had gastrointestinal (GI) tract perfusion; this was eliminated in seven cases (7%) after catheter repositioning. Forty-six (43%) placement attempts required embolization of 62 GI vessels to preclude GI chemoinfusion. Complications included one cerebrovascular accident (related to removal of a left brachial catheter), eight brachial artery thromboses (four that required emergent thrombectomy), six hepatic arterial dissections, four hepatic arterial thromboses, and four catheter malfunctions. CONCLUSIONS: HAI catheter placement via the left brachial artery has increased complications. Nearly one-half of placements required embolization of GI vessels to preclude GI perfusion. Global perfusion is possible in two-thirds of cases.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Cateterismo Periférico , Arteria Hepática , Infusiones Intraarteriales , Adulto , Anciano , Anciano de 80 o más Años , Arteria Braquial/diagnóstico por imagen , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Neoplasias Colorrectales/patología , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Hepática/diagnóstico por imagen , Humanos , Infusiones Intraarteriales/efectos adversos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Cintigrafía
14.
Radiology ; 199(2): 339-46, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-8668775

RESUMEN

PURPOSE: To determine initial and long-term results of metal stent placement in biliary strictures that failed to respond to balloon dilation. MATERIALS AND METHODS: Sixty-one metal stents were placed in 36 liver transplant recipients (age range, 3 months to 71 years) with biliary strictures that failed to respond to balloon dilation. Patients were followed up for up to 5 years. RESULTS: Initial stent placement was successful in all patients. Primary patency was 44% at 3 years and was 0% at 5 years; secondary patency was maintained at 88% at those intervals. Patency associated with the Gianturco Z stent was superior to that with the Palmaz stent. Stents located at anastomotic sites had higher patency rates than those at nonanastomotic sites. Major stent-related complications occurred in eight patients and included two pediatric deaths. CONCLUSION: Metal stents can be useful in the short term but have limited patency, often require repeat intervention, and have substantial complications. Long-term success depends heavily on repeat interventions or stent removal.


Asunto(s)
Colestasis/terapia , Trasplante de Hígado , Complicaciones Posoperatorias/terapia , Stents , Adolescente , Adulto , Anciano , Cateterismo , Niño , Preescolar , Colestasis/diagnóstico por imagen , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/terapia , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Radiografía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
15.
Radiology ; 188(3): 851-6, 1993 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8351361

RESUMEN

Three hundred twenty-four percutaneous inferior vena caval (IVC) filters of different designs were placed in 320 patients from April 1985 through June 1992. No acute mortality or substantial morbidity was attributed to filter placement. Radiologic or pathologic follow-up data were obtained in 227 (71%) patients (230 filters); clinical follow-up data only were obtained in 50 (16%) patients (50 filters). One hundred twenty (43%) patients died; post-filter-placement pulmonary emboli (PE) were related to the cause of death in eight. At IVC filter imaging studies, 26 of 137 (19%) filters demonstrated caval thrombus; 12 of 132 (9%) filters had delayed penetration through the IVC wall of greater than 3 mm; 13 of 230 (6%) filters migrated more than 1 cm; and five of 230 (2%) filters had fracture of a strut or leg. Deep venous thrombosis (DVT) at the insertion puncture site or in the lower extremity was noted in 26 of 117 (22%) cases of filter placement. Among patients without imaging studies, clinical suspicion of complications included PE in four patients, IVC thrombus in 14 patients, and lower-extremity DVT in 10 patients. Long-term clinical and radiologic follow-up of all IVC filters is indicated due to the relatively high prevalence of some complications.


Asunto(s)
Filtros de Vena Cava/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Falla de Equipo , Estudios de Seguimiento , Migración de Cuerpo Extraño , Humanos , Persona de Mediana Edad , Embolia Pulmonar/prevención & control , Punciones , Radiografía Intervencional , Recurrencia , Trombosis/etiología , Vena Cava Inferior/lesiones
16.
Cardiovasc Intervent Radiol ; 16(4): 251-3, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8402791

RESUMEN

A titanium Greenfield filter did not open following placement in the infrarenal inferior vena cava (IVC). Abdominal radiograph and cavogram showed no definite reason for filter malfunction. Intravascular ultrasound (IVUS) demonstrated the unopened filter in the IVC with thrombus binding the legs. The thrombus was disrupted with a catheter, and the filter completely expanded with a balloon. IVUS documented full-filter opening in addition to residual thrombus in the filter following manipulation.


Asunto(s)
Trombosis/diagnóstico por imagen , Titanio , Ultrasonografía Intervencional , Filtros de Vena Cava , Vena Cava Inferior/diagnóstico por imagen , Anciano , Falla de Equipo , Femenino , Humanos
18.
J Vasc Interv Radiol ; 3(2): 401-8, 1992 May.
Artículo en Inglés | MEDLINE | ID: mdl-1627893

RESUMEN

Simon nitinol vena caval filters were placed percutaneously in 20 patients. Follow-up (average, 14 months) data were available for 16 patients, and four patients were lost to follow-up. There were no proved or suspected cases of pulmonary embolism after filter insertion. Complications encountered included caval penetration (n = 5, one acute and four at follow-up), caval thrombus (n = 4, two determined radiologically and two clinically), postplacement deep venous thrombosis (n = 2, one radiologic and one clinical), filter migration (n = 1), and delayed fracture of a filter leg (n = 2). Although no deaths or significant morbidity resulted from any complication, the relatively high complication rate, especially of significant caval penetration (documented in 25% of filter insertions), merits continued short- and long-term assessment of patient status after filter placement.


Asunto(s)
Aleaciones , Filtros de Vena Cava , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Migración de Cuerpo Extraño/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/prevención & control , Radiografía , Trombosis/etiología , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/lesiones
19.
J Orthop Trauma ; 6(2): 135-8, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1602331

RESUMEN

This study comprises a series of 35 patients with pelvic or lower extremity fractures requiring surgery who also had a documented significant acute deep venous thrombosis (DVT). The authors treated these with low-dose Coumadin and 36 vena caval filters, which were used prophylactically prior to surgery. The patients received low-dose warfarin after placement of the vena caval filters and were maintained at 1.3-1.5 times the prothrombin control value for 6 weeks to 3 months. In this group of patients, there were no fatal pulmonary emboli and no clinically significant complications from filter placement. There were nine asymptomatic filter complications demonstrated radiographically in eight patients. Additionally, one patient with a tilted vena caval filter required placement of another filter. The combination of vena caval filters and low-dose warfarin appears to be a successful and relatively safe method of managing those patients who have acute DVT and require surgery for their pelvic or lower extremity fractures.


Asunto(s)
Fracturas Óseas/complicaciones , Tromboflebitis/terapia , Filtros de Vena Cava/normas , Terapia Combinada , Monitoreo de Drogas , Femenino , Estudios de Seguimiento , Fracturas Óseas/cirugía , Humanos , Masculino , Flebografía , Cuidados Preoperatorios , Tiempo de Protrombina , Tromboflebitis/complicaciones , Tromboflebitis/diagnóstico , Warfarina/administración & dosificación , Warfarina/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA