Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 477: 135338, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39084008

RESUMEN

The contaminated liquid mixture containing mucosalivary fluid and blood would be aerosolized during medical procedures, resulting in higher-risk exposures. The novelty of this research is integrating laser visualization and numerical characterization to assess the propagation and evaporation of contaminated droplets, and the interactive effects of humidity and temperature on exposure risks will be numerically evaluated in surgery environments. The numerical model evidenced by experiments can predict the mass balance of ejection droplets, the minimum required fallow time (FT) between appointments, and the disinfection region of greatest concern. Around 98.4 % of the ejection droplet mass will be removed after the cessation of ultrasonic scaling, while the initial droplet size smaller than 72.6µm will dehydrate and become airborne. The FT recommendation of 30 min is not over-cautious, and the extended FT (range of 28-37 min) should be instituted for low temperature (20.5 °C) and high humidity levels (60 %RH). The variation of the temperature and humidity in the range for human thermal comfort has little influence on the area of the disinfection region (0.15m2) and the cut-off size (72.6µm) of droplet deposition and suspension. This research can provide scientific evidence for the guidelines of environmental conditions in surgery rooms.


Asunto(s)
Humedad , Humanos , Quirófanos , Rayos Láser , Temperatura , Aerosoles/análisis , Modelos Teóricos , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Desinfección/métodos
2.
Sensors (Basel) ; 23(18)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37765723

RESUMEN

Environmental vibration pollution has serious negative impacts on human health. Among the various contributors to environmental vibration pollution in urban areas, rail transit vibration stands out as a significant source. Consequently, addressing this issue and finding effective measures to attenuate rail transit vibration has become a significant area of concern. An infilled trench can be arranged periodically along the propagation paths of the waves in the soil to attenuate vibration waves in a specific frequency range. However, the periodic infilled trench seems to be unsatisfactory for providing wide band gaps at low and medium frequencies. To improve the isolation performance of wave barriers at low to medium frequencies, a buried PT-WIB consisting of a periodic infilled trench and a wave impedance block barrier has been proposed in this paper. A three-dimensional finite element model has been developed to evaluate the isolation performance of three wave barriers. The influence of the PT-WIB's parameters on isolation performance has been analyzed. The results indicate that the combined properties of the periodic structure and the wave impedance block barrier can effectively achieve a wide attenuation zone at low and medium frequencies, enhancing the isolation performance for mitigating environmental vibration pollution.

3.
Sensors (Basel) ; 23(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36616908

RESUMEN

This paper proposes a muffler with simple geometry to effectively reduce low-frequency noise in ductwork systems. A muffler named infinity tube with an expansion chamber (ITEC) is developed from the infinity tube (IT). Theoretical and numerical analyses of wave propagation in the ITEC have been conducted in this paper. The transfer matrix method is adopted to predict transmission loss theoretically. The theoretical results are validated by the finite element method simulation. The comparison of the transmission loss between the IT and ITEC illustrates that the ITEC has an advantage in low-frequency noise reduction. The transmission loss results of the ITEC are compared with the Helmholtz resonator system to assess the potential for industrial application. Finally, the geometric parameters of the proposed ITEC on its noise attenuation performance have been analyzed. The proposed ITEC can effectively reduce low-frequency noise, and it is suitable for ductwork systems in constrained spaces.

4.
Sustain Cities Soc ; 74: 103134, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34540565

RESUMEN

In time, dental health care has slowly expanded beyond emergency treatment to treat oral diseases. How to reduce the cross-transmission risk in dental surgery has raised much more attention. Considering the lack of consistency of fallow time (FT) in its necessity and duration, the highly sensitive laser light scattering method has been proposed to visualize the airborne lifetime and decay rate of suspended particles in the dental surgery environment. The FT is defined as when the number of suspended particles drops to the level that the next patient can safely enter after the aerosol-generating procedures (AGPs). The ultrasonic scaling was performed in the mock-up experimental dental clinic with 6 air changes per hour (ACH), and the instantaneous moments of the droplets were recorded by a high-speed camera. Without any mitigation measures, the estimated FT in the single dental surgery environment with 6 ACH was in the range of 27-35 min, significantly affecting the number of daily dental services. Despite the cooperation of high-volume evacuation (HVE [IO]) cannot eliminate the FT to zero minutes, the equipment could reduce the required FT by 3-11 min for the suspended particles reducing the baseline levels. Owing to the longer airborne lifetime of suspended particles, the relevant protection equipment, especially respiratory protection, is quite essential in dental surgery. The obtained results of this study will provide evidence to establish the revised FT in dental surgery guidelines and protect the health and wellbeing of urban dwellers.

5.
Build Environ ; 205: 108225, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34376905

RESUMEN

The exposure risk of droplets and aerosols emitted from the oral cavity to the dental professionals and patients has received more attention especially the ongoing outbreak of COVID-19. The aim of this study is to address the question about how the use of the high-volume evacuation (HVE) alters the risk profiles compared with the situation only personal protective equipment (PPE). The risk profiles of the different situations were analyzed in terms of droplet velocity, flow field characteristics, and particle removal efficiency. The ultrasonic scaling with suction was performed in the mock-up experimental dental clinic, and the instantaneous moment when the HVE acted on the droplets was visualized using a laser light scattering technique. From the results of the velocity profiles, the hypothesis about the moderate effect of the HVE on high-velocity small droplets near the mannequin's mouth had been firstly proven in this study. The suction can be characterized as low-threshold equipment to bring substantial benefits to reduce the area of the contaminated region. Once the cooperation of suction, the pair of vortexes that were in the face shield area of the dental professional would be eliminated, removing the high-level contaminated region near the breathing area of dental professionals. Compared with the low and medium volume evacuation, the particle removal efficiency of the HVE was more stable at 60%. The research will provide references to the HVE recommendation in the dentistry clinical practice guidelines.

6.
Phys Fluids (1994) ; 33(4): 047111, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33953531

RESUMEN

In the setting of widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) community transmission, reducing the exposure risk on dental professionals and the next patients is the key to reopening dental services in this pandemic environment. The study is motivated by the lack of understanding of the flow-field characteristics and droplet distribution during aerosol-generating procedures. The particle image velocimetry measurements with high temporal and spatial resolutions were performed under ultrasonic scaling in the mockup experimental dental clinic. Compared with other methods focusing on the settled droplet particles, the study focused on the visualization of suspended droplets. From the results of the velocity vector and trajectory map, the high-level contaminated area will be within 1 m from the oral cavity. The vortex structures were identified by the vorticity index. In the surface near the patient's head, a counterclockwise vortex would carry some droplets and contaminate this region. The small droplets circulated in the turbulence cloud and the droplet nuclei generated by dehydration are the two primary sources of suspended particles, which may cause airborne transmission in the dental clinic. About 65%-74% of the droplets in ultrasonic scaling were in the range of 50-180 µ m . The research will provide references to the development of the precaution measures to reduce the SARS-CoV-2 exposure risk of dental professionals.

7.
Build Environ ; 171: 106673, 2020 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-32287993

RESUMEN

Interunit dispersion problems have been studied previously mainly through on-site measurements, wind tunnel tests, and CFD simulations. In this study, a scaled outdoor experiment was conducted to examine the interunit dispersion characteristics in consecutive two-dimensional street canyons. Tracer gas ( C O 2 ) was continuously released to simulate the pollutant dispersion routes between the rooms in street canyons. The wind velocity, wind direction, air temperature, and tracer gas concentrations were monitored simultaneously. Two important parameters, the air exchange rate and reentry ratio, were analyzed to reveal the ventilation performance and interunit dispersion of the rooms in the street canyons. Based on the real-time weather conditions, it was found that the ventilation performance of the source room varied according to the room location. The air exchange rate distribution of the leeward-side room was more stable than that of the windward side. The tracer gas was mainly transported in the vortex direction inside the street canyon, and the highest reentry ratio was observed at the room nearest to the source room along the transportation route. In addition, under real weather conditions, the rooms in the street canyon have a high probability of experiencing a high reentry ratio based on the maximum reentry ratio of each room. This study provides authentic airflow and pollutant dispersion information in the street canyons in an urban environment. The dataset of this experiment can be used to validate further numerical simulations.

9.
Sci Total Environ ; 653: 968-994, 2019 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-30759622

RESUMEN

High-rise deep street canyons usually experience poor ventilation and large vehicular pollutant exposure to residents in near-road buildings. Investigations are still required to clarify the flow and dispersion mechanisms in deep street canyons and explore techniques to reduce such large pollutant exposure. By conducting computational fluid dynamics (CFD) simulations validated by wind tunnel data and scale-model outdoor field measurements, we investigate the integrated impacts of aspect ratios, first-floor and second-floor elevated building designs, viaduct settings, height variations and wind catchers on the flow, personal intake fraction (P_IF) of CO (carbon dioxide) and its spatial mean value 〈P_IF〉 in two-dimensional (2D) street canyons. Results show that cases with H/W = 5 experience two counter-rotating vortices, much poorer ventilation and 1-2 orders larger 〈P_IF〉 (43.6-120.8 ppm) than H/W = 1 and 3 (3.8-4.3 and 5.6-5.8 ppm). Moreover, in cases with H/W = 5 the height variation results in three vertically-aligned vortices and much weaker wind, subsequently produces greater 〈P_IF〉 (1402-2047 ppm). To reduce 〈P_IF〉 with H/W = 5, various urban designs are evaluated. The first-floor elevated building design creates more effective ventilation pathways than the second-floor elevated type does and reduces 〈P_IF〉 at H/W = 5 by five orders (1402 to ~0.01 ppm) or two orders (43.6 to ~0.1 ppm) in cases with or without the height variation. However, such reductions at H/W = 1 and 3 are only 76.8%-81.4% and 22.4%-36.2% respectively. Wind catchers destroy the multi-vortex flow pattern as H/W = 5, produce a contra-clockwise main vortex and reduce 〈P_IF〉 by 1-2 orders for cases with or without the height variation.


Asunto(s)
Contaminación del Aire/análisis , Contaminación por Tráfico Vehicular/prevención & control , Emisiones de Vehículos/análisis , Contaminación del Aire/prevención & control , Ciudades , Exposición a Riesgos Ambientales , Hidrodinámica , Modelos Teóricos , Ventilación , Viento
10.
Noise Health ; 21(101): 142-154, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32719301

RESUMEN

INTRODUCTION: With the development of transportation system and the economy, the rapidly increasing number of automobiles brings the associated problem of road traffic noise, especially in metropolitan and densely populated high-rise cities like Hong Kong. In Hong Kong, approximately one million people are affected by severe road traffic noise. Excessive noise exposure is hazardous to the health and wellbeing of people and therefore has drawn progressively more attention in Hong Kong. The Calculation of Road Traffic Noise (CRTN) has been adopted as the sole tool to evaluate road traffic noise in the form of descriptor LA10. The accuracy and suitability of the CRTN method for predicting road traffic noise in Hong Kong were evaluated in this study by comparing the prediction results and measured traffic noise levels. The results show that the CRTN method was able to provide adequate predictions with correlation coefficients of 0.8032 and 0.7626 between the predicted and measured LA10 for 2007 and 2017 respectively. The predicted traffic noise levels on different floors of seven selected residential buildings in 2017 were compared with those predictions for the same buildings in 2007. The worsening traffic noise exposure in these residential buildings was analysed and some suggestions and counter-measures to alleviate the traffic noise problems are put forward. Since the situation of Hong Kong is an example of what may happen in other cities, the present longitudinal study of the road traffic noise in Hong Kong hopes to contribute to a better urban acoustic environment worldwide. CONTEXT: Excessive noise exposure is hazardous to the health and wellbeing of people and therefore has drawn progressively more attention in Hong Kong. The urban road traffic noise exposure of residential buildings in Hong Kong over the past decade has been analysed. AIMS: This study aims to assess the road traffic noise exposure of residential buildings over the past decade. SETTINGS AND DESIGN: Measurements of traffic noise levels at some selected residential buildings were first conducted in 2007, and then repeated at the same buildings in 2017. MATERIAL AND METHODS: The CRTN was adopted to predict the traffic noise levels based on the recorded traffic flow data. RESULTS: The exposure of these buildings to road traffic noise is higher in 2017 than in 2007. The study illustrates that the deterioration of the urban acoustic environment may not be caused by an increased total number of vehicles, but that heavy vehicles are dominantly responsible for the increased traffic noise levels. Restriction of vehicle velocity for urban street canyons is useless for road traffic noise control. CONCLUSIONS: This study shows the deterioration of traffic noise levels is mainly due to the increased heavy vehicles instead of the increased total number of vehicles. The alleviation of traffic noise levels by velocity restriction may not be obvious for urban street canyons and may only work with a certain velocity range.


Asunto(s)
Exposición a Riesgos Ambientales/análisis , Vehículos a Motor , Ruido del Transporte , Ciudades , Exposición a Riesgos Ambientales/prevención & control , Predicción/métodos , Hong Kong , Vivienda , Humanos , Conceptos Matemáticos , Modelos Teóricos , Vehículos a Motor/estadística & datos numéricos , Ruido del Transporte/prevención & control , Factores de Tiempo
11.
Sustain Cities Soc ; 42: 314-324, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32288991

RESUMEN

An acceptable pedestrian level wind environment is essential to maintain an enjoyable outdoor space for city residents. Low wind velocity environment can lead to uncomfortable outdoor thermal experience in hot and humid summer, and it is unable to remove the pollutants out of city canyons. However, the average wind velocity at pedestrian level is significantly lowered by closely spaced tall buildings in modern megacities. To improve the low wind velocity environment at pedestrian level in high-density cities, a general framework and detailed guidelines are needed. This study is the first time to develop such a framework, and provide detailed guidelines for improving pedestrian level low wind velocity environment in high-density cities. Additionally, a detailed review and summarisation of evaluation criteria and improvement measures are presented in this paper, which provide additional options for urban planners. To investigate the performance of the framework, the Hong Kong Polytechnic University campus was utilised as a case study. Results showed that pedestrian level wind comfort was greatly improved with the developed framework. The outcomes of this study can assist city planners to improve the low wind velocity environment, and can help policy makers to establish sustainable urban planning policies.

12.
Build Simul ; 11(6): 1245-1253, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-32218905

RESUMEN

This study examines the influence of building envelope features on interunit dispersion around multi-story buildings, when the presence of an upstream interfering building is also considered. Validated CFD methods in the steady-state RANS framework are employed. In general, the reentry ratios of pollutant from a source unit to adjacent units are mostly in the order of 0.1%, but there are still many cases being in the order of 1%. The influence of envelope features is dependent strongly on the interaction between local wind direction and envelope feature. In a downward dominated near-facade flow field, the presence of vertical envelope features forms dispersion channels to intensify the unidirectional spread. Horizontal envelope features help induce the dilution of pollutant to the main stream and weakens largely the vertical interunit dispersion. The large influences caused by the presence of envelope features extend the existing understanding of interunit dispersion based on flat-facade buildings.

13.
Artículo en Inglés | MEDLINE | ID: mdl-28925978

RESUMEN

Occupational noise is unavoidably produced from dental equipment, building facilities, and human voices in the dental environment. The purpose of this study was to investigate the effect of occupational noise exposure on the dental professionals' health condition. The psychoacoustics approach noise exposure assessment followed by the health risk assessment was carried on at the paediatric dentistry clinic and the dental laboratory in the Prince Philip Dental Hospital of Hong Kong. The A-weighted equivalent sound level, total loudness, and sharpness values were statistically significantly higher for the noise at the laboratory than that at the clinic. The degree of perceived influences and sharpness of noise were found to have the impacts on the dental professionals' working performance and health. Moreover, the risk of having a bad hearing state would a have 26% and 31% higher chance for a unit increment of the short-term and long-term impact scores, respectively. The dental professionals with the service length more than 10 years and the daily working hours of more than eight showed the highest risk to their hearing state. The worse the hearing state was, the worse the health state was found for the dental professionals. Also, the risk of dissatisfaction would be increased by 4.41 and 1.22 times for those who worked at the laboratory and a unit increment of the long-term impact score. The constructed health risk mode with the scientific and statistical evidence is hence important for the future noise management of environmental improvement.


Asunto(s)
Personal de Odontología , Odontólogos , Pérdida Auditiva Provocada por Ruido/epidemiología , Ruido en el Ambiente de Trabajo/efectos adversos , Exposición Profesional/efectos adversos , Adulto , Equipo Dental , Femenino , Hong Kong/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Psicoacústica , Riesgo , Adulto Joven
14.
J Acoust Soc Am ; 142(1): EL56, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28764475

RESUMEN

A combined approach based on finite element method and genetic algorithm (FEM-GA) is proposed for optimizing the natural frequencies of plate structures. This approach can identify the optimal boundary conditions so that the plate's natural frequencies can be adjusted simultaneously to their corresponding target values. In this approach, the natural frequencies of plates with arbitrary boundary conditions are calculated by FEM, while GA is employed for searching the optimal solutions of the multiple-objective optimization problem. The FEM is validated by comparing with previous results. The proposed approach is illustrated by numerical examples. The results demonstrate the effectiveness of this approach.

15.
Sensors (Basel) ; 17(5)2017 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-28471383

RESUMEN

The acoustic performance of the ducted Helmholtz resonator (HR) system is analyzed theoretically and numerically. The periodic HR array could provide a wider noise attenuation band due to the coupling of the Bragg reflection and the HR's resonance. However, the transmission loss achieved by a periodic HR array is mainly dependent on the number of HRs, which restricted by the available space in the longitudinal direction of the duct. The full distance along the longitudinal direction of the duct for HR's installation is sometimes unavailable in practical applications. Only several pieces of the duct may be available for the installation. It is therefore that this paper concentrates on the acoustic performance of a HR array consisting of several periodic parts. The transfer matrix method and the Bragg theory are used to investigate wave propagation in the duct. The theoretical prediction results show good agreement with the Finite Element Method (FEM) simulation results. The present study provides a practical way in noise control application of ventilation ductwork system by utilizing the advantage of periodicity with the limitation of available completed installation length for HRs.

16.
Build Environ ; 124: 245-257, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32287974

RESUMEN

Owing to the void space at lower heights, lift-up buildings have high building permeability at ground level and subsequently improve the air circulation in congested urban areas. Despite this advantage, the lift-up design has been sparsely adopted for buildings in urban areas partly because of the lack of understanding of the combined effects of building dimensions and lift-up design on the surrounding pedestrian level wind (PLW) field. Therefore, this study aims to investigate the influence of lift-up buildings with different aspect ratios (height/width) on the surrounding PLW field and pedestrian wind comfort level. Five lift-up buildings with aspect ratios 4:1 to 0.5:1 were tested in a boundary layer wind tunnel and results were compared with those of five buildings with similar dimensions but without lift-up design. The results reveal a strong dependence of the maximum wind speed in lift-up areas with building height, which results subsequently a small area of acceptable wind conditions near tall and slender lift-up buildings. Lift-up designs adopted for short and wide buildings produce larger areas of pedestrian wind comfort. The central cores modified with corner modifications are effective in increasing the pedestrian wind comfort in the lift-up area of tall and slender buildings.

17.
Build Environ ; 117: 154-165, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-32362712

RESUMEN

Modern megacities are teeming with closely-spaced tall buildings, which limit air circulation at the pedestrian level. The resultant lack of air circulation creates poorly ventilated areas with accumulated air pollutants and thermal discomfort in the summer. To improve air circulation at the pedestrian level, buildings may be designed to have a 'lift-up' shape, in which the main structure is supported by a central core, columns or shear walls. However, a lack of knowledge on the influence of the 'lift-up' design on the surrounding wind environment limits the use of 'lift-up' buildings. This study aims to investigate the influence of 'lift-up' buildings and their dimensions on the pedestrian-level wind environments using wind tunnel tests. A parametric study was undertaken by using 9 'lift-up' building models with different core heights and widths. The results were compared with the surrounding wind environment of a control building with similar dimensions. The results reveal that the 'lift-up' core height is the most influential parameter and governs the area and magnitude of high and low wind speed zones around such buildings. Based on wind tunnel test results and a selected comfort criterion, appropriate core dimensions could be selected to have acceptable wind conditions near lift-up buildings.

18.
J Acoust Soc Am ; 140(6): EL471, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-28040005

RESUMEN

This paper presents a theoretical study of the dispersion characteristics of sound wave propagation in a periodic ducted Helmholtz resonator (HR) system. The predicted result fits well with a numerical simulation using a finite element method. This study indicates that for the same system, no matter how many HRs are connected or what the periodic distance is, the area under average transmission loss T L¯ curves is always the same. The broader the noise attenuation band, the lower the peak attenuation amplitude. A noise control zone compromising the attenuation bandwidth or peak amplitude is proposed for noise control optimization.

19.
Noise Health ; 17(79): 429-39, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26572703

RESUMEN

Governments all over the world have enacted environmental noise directives and noise control ordinances/acts to protect tranquility in residential areas. However, there is a lack of literature on the evaluation of whether the Acceptable Noise Levels (ANLs) stipulated in the directive/ordinance/act are actually achievable. The study aimed at measuring outdoor environmental noise levels in Hong Kong and identifying whether the measured noise levels are lower than the stipulated ANLs at 20 categories of residential areas. Data were gathered from a territory-wide noise survey. Outdoor noise measurements were conducted at 203 residential premises in urban areas, low-density residential areas, rural areas, and other areas. In total, 366 daytime hourly Leq outdoor noise levels, 362 nighttime hourly Leq outdoor noise levels, and 20 sets of daily, that is, 24 L(eq,1-)h outdoor noise levels were recorded. The mean daytime L(eq,1-h) values ranged 54.4-70.8 dBA, while the mean nighttime L(eq,1-h) values ranged 52.6-67.9 dBA. When the measured noise levels were compared with the stipulated ANLs, only three out of the 20 categories of areas had outdoor noise levels below ANLs during daytime. All other areas (and all areas during nighttime) were found to have outdoor noise levels at or above ANLs.


Asunto(s)
Ciudades , Ambiente , Ruido/legislación & jurisprudencia , Política Pública , Planificación Ambiental , Monitoreo del Ambiente , Hong Kong , Humanos , Ruido del Transporte , Características de la Residencia , Población Rural
20.
J Acoust Soc Am ; 131(2): 1172-82, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22352492

RESUMEN

Helmholtz resonator is often used to reduce noise in a narrow frequency range. To obtain a broader noise attenuation band, combing several resonators is a possible way. This paper presents a theoretical study of sound propagation in a one-dimensional duct with identical side-branch resonators mounted periodically. The analysis of each resonator was based on a distributed-parameter model that considered multi-dimensional wave propagation in its neck-cavity interface. This model provided a more accurate prediction of the resonant frequency of the resonator than traditional lumped-parameter model. Bloch wave theory and the transfer matrix method were used to investigate wave propagation in these spatially periodic resonators. The results predicted by the theory fit well with the computer simulation using a three-dimensional finite element method and the experimental results. This study indicates that the wave coupling in this periodic system results in the dispersion of the frequency band into the stop and the pass bands. The long-term significance is that periodic resonators may more effectively control noise in ducts by broadening the bandwidth they attenuate and increasing the magnitude of sound attenuation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA