Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Infect Dis ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39255068

RESUMEN

BACKGROUND: Blood biomarkers of neurological injury could provide a rapid diagnosis of central nervous system (CNS) injury caused by infections. An FDA-approved assay for mild traumatic brain injury (TBI) measures glial fibrillary acidic protein (GFAP) and ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), which signal astrocyte and neuronal injury, respectively. Here, we assessed the applicability of this biomarker assay for determining infection-induced brain injury. METHODS: We measured serum levels of GFAP and UCH-L1 retrospectively in serum samples from three study populations: 1) human cases infected with Venezuelan equine encephalitis virus (VEEV) and Madariaga virus (MADV) (n = 73), 2) human sepsis patients who were severely ill or diagnosed with encephalitis (n = 66), and 3) sepsis cases that were subsequently evaluated for cognitive impairment (n = 64). RESULTS: In the virus infection group, we found elevated GFAP for VEEV (p = 0.014) and MADV (p = 0.011) infections, which correlated with seizures (p = 0.006). In the bacterial sepsis group, GFAP was elevated in cases diagnosed with encephalitis (p = 0.0007) and correlated with headaches (p = 0.0002). In the bacterial sepsis cases with a later cognitive assessment, elevated GFAP (p = 0.0057) at study enrollment was associated with cognitive impairment six months later with a positive prognostic capacity of 79% (CI: 66-95%; p = 0.0068). CONCLUSIONS: GFAP and UCH-L1 levels measured using an FDA-approved assay for TBI may indicate brain injury resulting from viral or bacterial infections and could predict the development of neurological sequelae.

2.
J Immunol Methods ; 524: 113586, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38040191

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the causative agent of the coronavirus disease 2019 (COVID-19) global pandemic. Rapid and sensitive detection of the virus soon after infection is important for the treatment and prevention of transmission of COVID-19, and detection of antibodies is important for epidemiology, assessment of vaccine immunogenicity, and identification of the natural reservoir and intermediate host(s). Patient nasal or oropharyngeal swabs or saliva used in conjunction with polymerase chain reaction (PCR) detect SARS-CoV-2 RNA, whereas lateral flow immunoassays (LFI) detect SARS-CoV-2 proteins. Enzyme-linked immunosorbent assays (ELISA) detect anti-SARS-CoV-2 antibodies in blood. Although effective, these assays have poor sensitivity (e.g., LFI) or are labor intensive and time consuming (PCR and ELISA). Here we describe the development of rapid, automated ELISA-based immunoassays to detect SARS-CoV-2 antigens and antibodies against the virus. The Simple Plex™ platform uses rapid microfluidic reaction kinetics for sensitive analyte detection with small sample volumes. We developed three sensitive <90-min Simple Plex immunoassays that measure either the SARS-CoV-2 antigens or the immune response to SARS-CoV-2, including neutralizing antibodies, in serum from COVID-19 patients.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Prueba de COVID-19 , ARN Viral , Microfluídica , Inmunoglobulina G , Inmunoensayo , Anticuerpos Antivirales , Sensibilidad y Especificidad
3.
PLoS One ; 7(3): e32801, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22412927

RESUMEN

Significant efforts to develop both laboratory and field-based detection assays for an array of potential biological threats started well before the anthrax attacks of 2001 and have continued with renewed urgency following. While numerous assays and methods have been explored that are suitable for laboratory utilization, detection in the field is often complicated by requirements for functionality in austere environments, where limited cold-chain facilities exist. In an effort to overcome these assay limitations for Bacillus anthracis, one of the most recognizable threats, a series of single domain antibodies (sdAbs) were isolated from a phage display library prepared from immunized llamas. Characterization of target specificity, affinity, and thermal stability was conducted for six sdAb families isolated from rounds of selection against the bacterial spore. The protein target for all six sdAb families was determined to be the S-layer protein EA1, which is present in both vegetative cells and bacterial spores. All of the sdAbs examined exhibited a high degree of specificity for the target bacterium and its spore, with affinities in the nanomolar range, and the ability to refold into functional antigen-binding molecules following several rounds of thermal denaturation and refolding. This research demonstrates the capabilities of these sdAbs and their potential for integration into current and developing assays and biosensors.


Asunto(s)
Bacillus anthracis/inmunología , Anticuerpos de Cadena Única/inmunología , Secuencia de Aminoácidos , Carbunco/diagnóstico , Anticuerpos Antibacterianos/química , Anticuerpos Antibacterianos/inmunología , Anticuerpos Antibacterianos/metabolismo , Afinidad de Anticuerpos/inmunología , Especificidad de Anticuerpos/inmunología , Humanos , Inmunoensayo , Cinética , Datos de Secuencia Molecular , Estabilidad Proteica , Alineación de Secuencia , Anticuerpos de Cadena Única/química , Anticuerpos de Cadena Única/metabolismo , Esporas Bacterianas/inmunología , Temperatura
4.
J Immunol Methods ; 263(1-2): 35-41, 2002 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-12009202

RESUMEN

We have achieved sensitive, rapid and reproducible detection of three biological threat agents in a variety of biological and environmental matrices using the DELFIA time-resolved fluorometry (TRF) assay system (Perkin-Elmer Life Sciences, Akron, OH). Existing ELISA assays for the detection of Francisella tularensis, Clostridium botulinum A/B neurotoxin (BotNT A/B), and Staphylococcus aureus enterotoxin B (SEB) were converted to TRF assays. They use 100 microl of positive control or unknown per test well and require just over 2 h to run. Fluorescent signal read time is a fraction of a second per well. The assay format consists of a capture ELISA utilizing a biotinylated capture antibody, prebound to a streptavidin-coated 96-well plate and a lanthanide (Europium, Eu3+)-labeled detector antibody. The bound Eu-labeled detector antibody produces a fluorescent signal upon the addition of an enhancement solution. The signal results from the dissociation of the Europium from the antibody, creating a micelle, thus amplifying the signal nearly one million-fold. Sensitivities achieved by these assays were between 4 and 20 pg/ml in buffer. Additionally, we have tested this system in different matrices such as serum, urine, dirt, and sewage. Concentration curves generated from standard solutions produced a wide linear range making serial dilutions of unknown samples unnecessary. DELFIA TRF assays are significantly better in terms of sensitivity, linear range, and run time than standard capture ELISAs and should facilitate early detection of potential biological warfare agents in clinical and environmental samples.


Asunto(s)
Antígenos Bacterianos/análisis , Guerra Biológica , Toxinas Botulínicas Tipo A/análisis , Toxinas Botulínicas/análisis , Enterotoxinas/análisis , Fluorometría/métodos , Francisella tularensis/aislamiento & purificación , Staphylococcus aureus , Antígenos Bacterianos/sangre , Antígenos Bacterianos/orina , Toxinas Botulínicas/sangre , Toxinas Botulínicas/orina , Toxinas Botulínicas Tipo A/sangre , Toxinas Botulínicas Tipo A/orina , Enterotoxinas/sangre , Enterotoxinas/orina , Ensayo de Inmunoadsorción Enzimática/métodos , Fluorescencia , Humanos , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA