Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomicrofluidics ; 12(5): 054108, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30344835

RESUMEN

Cancer is the most serious disease worldwide, and ovarian cancer (OvCa) is the second most common type of gynecological cancer. There is consequently an urgent need for early-stage detection of OvCa, which requires affinity reagent biomarkers for OvCa. Systematic evolution of ligands by exponential enrichment (SELEX) and phage display technology are two powerful technologies for identifying affinity reagent biomarkers. However, the benchtop protocols for both screening technologies are relatively lengthy and require well-trained personnel. We therefore developed a novel, integrated microfluidic system capable of automating SELEX and phage display technology. Instead of using cancer cell lines, it is the first work which used tissue slides as screening targets, which possess more complicated and uncovered information for affinity reagents to recognize. This allowed for the identification of aptamer (nucleic acid) and peptide probes specific to OvCa cells and tissues. Furthermore, this developed system could be readily modified to uncover affinity reagents for diagnostics or even target therapy of other cancer cell types in the future.

2.
Biomicrofluidics ; 11(3): 034122, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28713478

RESUMEN

Gynecological cancer is difficult to be diagnosed at early stages. The relatively high mortality rate has been a serious issue accordingly. We herein reported a diagnosis method by using circulating tumor cells (CTCs) which have been extensively explored as a potential tool for diagnostics and prognostics of ovarian cancers. Nonetheless, the detection of CTCs still remains a challenge because of the difficulty in isolating them from whole blood samples since they are shed into the vasculature from primary tumors and circulate irregularly in the bloodstream in extremely low concentrations. In this work, we reported a new, integrated microfluidic system capable of (1) red blood cells lysis, (2) white blood cell (WBC) depletion via a negative selection process, and (3) capture of target cancer cells from whole blood samples using aptamer-binding technology. Furthermore, this is the first time that an aptamer was used to capture ovarian cancer cells owing to its high affinity. The new microfluidic chip could efficiently perform the entire process in one hour without human intervention at a high recovery rate and a low false positive detection rate when compared with antibody-based systems. A high recovery rate for the isolation of CTCs within a short period of time has been reported when compared to the traditional negative or positive selection approach by using traditional antibody biomarkers. More importantly, "false positive" results from WBCs could be significantly alleviated due to the high specificity of the cancer cell-specific aptamers. The developed integrated microfluidic system could be promising for the isolation and detection of CTCs, which could be used for early diagnosis and prognosis of cancers.

3.
Biomicrofluidics ; 11(4): 044101, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28713479

RESUMEN

An integrated microfluidic system capable of automatically identifying aptamers specific to cholangiocarcinoma (CCA) cells was developed herein. The developed system was capable of performing cell-based systematic evolution of ligands via an exponential enrichment (Cell-SELEX) process on-chip, and only six rounds of Cell-SELEX were required to identify high specificity aptamers; this represents a significant improvement in speed over conventional SELEX, in which 15-20 rounds are typically required. Using the microfluidic chip developed, three aptamers specific to CCA cells (one for SNU-478 cells and two for HuCCT-1 cells) were successfully screened. This automated system could be modified to uncover aptamer probes against other cancer cells, thereby allowing for earlier diagnosis and consequently a potentially improved prognosis.

4.
Sci Rep ; 7(1): 4248, 2017 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-28652576

RESUMEN

Cholangiocarcinoma (CCA), a biliary tract malignancy, accounts for 20% of all liver cancers. There are several existing methods for diagnosis of CCA, though they are generally expensive, laborious, and suffer from low detection rates. Herein we first developed a means of partially purifying human bile for consequent injection into a microfluidic chip. Then, the novel microfluidic system, which featured 1) a cell capture module, 2) an immunofluorescence (IF) staining module featuring two CCA-specific biomarkers, and 3) an optical detection module for visualization of antibody probes bound to these CCA marker proteins, was used to detect bile duct cancer cells within partially purified bile samples. As a proof of concept, CCA cells were successfully captured and identified from CCA cell cultures, blood samples inoculated with CCA cells, and clinical bile specimens. In 7.5 ml of bile, this system could detect >2, 0, and 1 positive cells in advanced stage patients, healthy patients, and chemotherapy-treated patients, respectively. In conclusion, our microfluidic system could be a promising tool for detection of cancer cells in bile, even at the earliest stages of CCA when cancer cells are at low densities relative to the total population of epithelial cells.


Asunto(s)
Biomarcadores de Tumor/aislamiento & purificación , Colangiocarcinoma/diagnóstico , Detección Precoz del Cáncer , Dispositivos Laboratorio en un Chip , Bilis/química , Biomarcadores de Tumor/sangre , Línea Celular Tumoral , Colangiocarcinoma/sangre , Colangiocarcinoma/genética , Colangiocarcinoma/patología , Técnica del Anticuerpo Fluorescente/métodos , Humanos
5.
Lab Chip ; 16(15): 2759-74, 2016 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-27381813

RESUMEN

Microfluidic technologies have miniaturized a variety of biomedical applications, and these chip-based systems have several significant advantages over their large-scale counterparts. Recently, this technology has been used for automating labor-intensive and time-consuming screening processes, whereby affinity reagents, including aptamers, peptides, antibodies, polysaccharides, glycoproteins, and a variety of small molecules, are used to probe for molecular biomarkers. When compared to conventional methods, the microfluidic approaches are faster, more compact, require considerably smaller quantities of samples and reagents, and can be automated. Furthermore, they allow for more precise control of reaction conditions (e.g., pH, temperature, and shearing forces) such that more efficient screening can be performed. A variety of affinity reagents for targeting cancer cells or cancer biomarkers are now available and will likely replace conventional antibodies. In this review article, the selection of affinity reagents for cancer cells or cancer biomarkers on microfluidic platforms is reviewed with the aim of highlighting the utility of such approaches in cancer diagnostics.


Asunto(s)
Anticuerpos Antineoplásicos/metabolismo , Aptámeros de Nucleótidos/metabolismo , Biomarcadores de Tumor/metabolismo , Dispositivos Laboratorio en un Chip , Neoplasias/metabolismo , Oligonucleótidos/metabolismo , Animales , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/metabolismo , Anticuerpos Antineoplásicos/química , Aptámeros de Nucleótidos/química , Biomarcadores de Tumor/sangre , Línea Celular Tumoral , Células Cultivadas , Técnicas de Cocultivo , Humanos , Ácidos Nucleicos Inmovilizados/química , Ácidos Nucleicos Inmovilizados/metabolismo , Proteínas Inmovilizadas/metabolismo , Dispositivos Laboratorio en un Chip/tendencias , Leucocitos/citología , Leucocitos/metabolismo , Ligandos , Ratones , Neoplasias/sangre , Neoplasias/diagnóstico , Neoplasias/patología , Oligonucleótidos/química , Anticuerpos de Cadena Única/química , Anticuerpos de Cadena Única/metabolismo
6.
Lab Chip ; 16(8): 1447-56, 2016 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-26987542

RESUMEN

The extraction of a cell's nucleus is an essential technique required for a number of procedures, such as disease diagnosis, genetic replication, and animal cloning. However, existing nucleus extraction techniques are relatively inefficient and labor-intensive. Therefore, this study presents an innovative, microfluidics-based approach featuring optically-induced cell lysis (OICL) for nucleus extraction and collection in an automatic format. In comparison to previous micro-devices designed for nucleus extraction, the new OICL device designed herein is superior in terms of flexibility, selectivity, and efficiency. To facilitate this OICL module for continuous nucleus extraction, we further integrated an optically-induced dielectrophoresis (ODEP) module with the OICL device within the microfluidic chip. This on-chip integration circumvents the need for highly trained personnel and expensive, cumbersome equipment. Specifically, this microfluidic system automates four steps by 1) automatically focusing and transporting cells, 2) releasing the nuclei on the OICL module, 3) isolating the nuclei on the ODEP module, and 4) collecting the nuclei in the outlet chamber. The efficiency of cell membrane lysis and the ODEP nucleus separation was measured to be 78.04 ± 5.70% and 80.90 ± 5.98%, respectively, leading to an overall nucleus extraction efficiency of 58.21 ± 2.21%. These results demonstrate that this microfluidics-based system can successfully perform nucleus extraction, and the integrated platform is therefore promising in cell fusion technology with the goal of achieving genetic replication, or even animal cloning, in the near future.


Asunto(s)
Núcleo Celular , Dispositivos Laboratorio en un Chip , Fenómenos Ópticos , Muerte Celular , Membrana Celular/metabolismo , Electricidad , Diseño de Equipo , Células HEK293 , Humanos
7.
Biomicrofluidics ; 9(5): 054121, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26543513

RESUMEN

Affinity reagents recognizing biomarkers specifically are essential components of clinical diagnostics and target therapeutics. However, conventional methods for screening of these reagents often have drawbacks such as large reagent consumption, the labor-intensive or time-consuming procedures, and the involvement of bulky or expensive equipment. Alternatively, microfluidic platforms could potentially automate the screening process within a shorter period of time and reduce reagent and sample consumption dramatically. It has been demonstrated recently that a subpopulation of tumor cells known as cancer stem cells possess high drug resistance and proliferation potential and are regarded as the main cause of metastasis. Therefore, a peptide that recognizes cancer stem cells and differentiates them from other cancer cells will be extremely useful in early diagnosis and target therapy. This study utilized M13 phage display technology to identify peptides that bind, respectively, to colon cancer cells and colon cancer stem cells using an integrated microfluidic system. In addition to positive selection, a negative selection process was integrated on the chip to achieve the selection of peptides of high affinity and specificity. We successfully screened three peptides specific to colon cancer cells and colon cancer stem cells, namely, HOLC-1, HOLC-2, and COLC-1, respectively, and their specificity was measured by the capture rate between target, control, and other cell lines. The capture rates are 43.40 ± 7.23%, 45.16 ± 7.12%, and 49.79 ± 5.34% for colon cancer cells and colon cancer stem cells, respectively, showing a higher specificity on target cells than on control and other cell lines. The developed technique may be promising for early diagnosis of cancer cells and target therapeutics.

8.
Sci Rep ; 5: 10326, 2015 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-25999049

RESUMEN

Colorectal cancer (CRC) is the most frequently diagnosed cancer around the world, causing about 700,000 deaths every year. It is clear now that a small fraction of CRC, named colorectal cancer stem cells (CSCs) exhibiting self-renewal and extensive proliferative activities, are hard to be eradicated. Unfortunately, highly specific biomarkers for colorectal CSC (CR-CSCs) are lacking that prohibits the development of effective therapeutic strategies. This study designed and manufactured a novel microfluidic system capable of performing a fully automated cell-based, systematic evolution of ligands by exponential enrichment (SELEX) process. Eight CR-CSC/CRC-specific aptamers were successfully selected using the microfluidic chip. Three of the aptamers showed high affinities towards their respective target cells with a dissociation constant of 27.4, 28.5 and 12.3 nM, which are comparable to that of antibodies.


Asunto(s)
Aptámeros de Nucleótidos/metabolismo , Técnicas Analíticas Microfluídicas , Células Madre Neoplásicas/citología , Aptámeros de Nucleótidos/química , Secuencia de Bases , Biomarcadores de Tumor/metabolismo , Línea Celular Tumoral , Neoplasias Colorrectales/metabolismo , Neoplasias Colorrectales/patología , ADN de Cadena Simple/química , ADN de Cadena Simple/metabolismo , Citometría de Flujo , Humanos , Separación Inmunomagnética , Cinética , Técnicas Analíticas Microfluídicas/instrumentación , Células Madre Neoplásicas/metabolismo , Técnica SELEX de Producción de Aptámeros
9.
Lab Chip ; 14(20): 4017-28, 2014 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-25144781

RESUMEN

Ovarian cancer (OvCa) is the second most common type of gynecological cancer. More seriously, the prognosis for survival is relatively poor if an early OvCa diagnosis is not achieved. However, it is extremely challenging to diagnose very early stage OvCa, when treatments are the most effective, because of the lack of specific and sensitive biomarkers. Therefore, in order to achieve early detection of OvCa, screening and identifying biomarkers with high specificity and affinity are greatly needed. In this study, an integrated microfluidic system capable of performing cell-based systematic evolution of ligands by an exponential enrichment (Cell-SELEX) process was developed for automatic, high-throughput screening of multiple cell lines to competitively select aptamer-based biomarkers for OvCa. This on-chip Cell-SELEX process only required five rounds of aptamer selection, which is much faster than using a conventional SELEX process (22 rounds). Using this on-chip process, 13 aptamers specific to OvCa cells were successfully screened and three of them showed high affinity towards target cells with dissociation constants of 1.8 nM, 8.3 nM, and 1.3 nM. Analysis of stained fluorescence images and competitive testing against multiple cancer cell lines (cervical cancer, breast cancer, lung cancer, and liver cancer) were performed to verify the specificity of these selected aptamers. The results demonstrated that this developed system could perform the on-chip Cell-SELEX selection successfully and could be applied for personalized aptamer screening or targeted therapy monitoring in the near future.


Asunto(s)
Aptámeros de Nucleótidos/química , Automatización , Separación Celular/métodos , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Neoplasias Ováricas/patología , Animales , Células Cultivadas , Femenino , Células Hep G2 , Humanos , Ligandos , Células MCF-7 , Ratones , Técnicas Analíticas Microfluídicas/instrumentación , Células 3T3 NIH
10.
Nanomedicine ; 10(4): 819-29, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24333595

RESUMEN

Magnetic manganese ferrite (MnFe2O4) nanoparticles with approximately 100nm in diameter were used to improve the performance of an immunoassay for detecting influenza infections. The synthesized nanoparticles were tested for long-term storage to confirm the stability of their thermal decomposition process. Then, an integrated microfluidic system was developed to perform the diagnosis process automatically, including virus purification and detection. To apply these nanoparticles for influenza diagnosis, a micromixer was optimized to reduce the dead volume within the microfluidic chip. Furthermore, the mixing index of the micromixer could achieve as high as 97% in 2seconds. The optical signals showed that this nanoparticle-based immunoassay with dynamic mixing could successfully achieve a detection limit of influenza as low as 0.007 HAU. When compared with the 4.5-µm magnetic beads, the optical signals of the MnFe2O4 nanoparticles were twice as sensitive. Furthermore, five clinical specimens were tested to verify the usability of the developed system. FROM THE CLINICAL EDITOR: In this study, magnetic manganese ferrite nanoparticles were used to improve the performance of a novel immunoassay for the rapid and efficient detection of influenza infections.


Asunto(s)
Óxido Ferrosoférrico/química , Gripe Humana/diagnóstico , Técnicas Analíticas Microfluídicas/métodos , Nanopartículas/química , Orthomyxoviridae/inmunología , Animales , Perros , Humanos , Inmunoensayo/métodos , Células de Riñón Canino Madin Darby , Técnicas Analíticas Microfluídicas/instrumentación , Orthomyxoviridae/química , Sensibilidad y Especificidad
11.
Biomed Microdevices ; 15(3): 539-51, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23420191

RESUMEN

Seasonal and novel influenza infections have the potential to cause worldwide pandemics. In order to properly treat infected patients and to limit its spread, a rapid, accurate and automatic influenza diagnostic tool needs to be developed. This study therefore presents a new integrated microfluidic system for the rapid detection of influenza infections. It integrated a suction-type, pneumatic-driven microfluidic control module, a magnetic bead-based fluorescent immunoassay (FIA) and an end-point optical detection module. This new system can successfully distinguish between influenza A and B using a single chip test within 15 min automatically, which is faster than existing devices. By utilizing the micromixers to thoroughly wash out the sputum-like mucus, this microfluidic system could be used for the diagnosis of clinical specimens and reduced the required sample volume to 40 µL. Furthermore, the results of diagnostic assays from 86 patient specimens have demonstrated that this system has 84.8 % sensitivity and 75.0 % specificity. This developed system may provide a powerful platform for the fast screening of influenza infections.


Asunto(s)
Inmunoensayo/métodos , Virus de la Influenza A/aislamiento & purificación , Gripe Humana/virología , Imanes/química , Técnicas Analíticas Microfluídicas/métodos , Microesferas , Virión/aislamiento & purificación , Anticuerpos Monoclonales/inmunología , Humanos , Subtipo H1N1 del Virus de la Influenza A/inmunología , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Subtipo H1N1 del Virus de la Influenza A/fisiología , Subtipo H3N2 del Virus de la Influenza A/inmunología , Subtipo H3N2 del Virus de la Influenza A/aislamiento & purificación , Subtipo H3N2 del Virus de la Influenza A/fisiología , Virus de la Influenza A/inmunología , Virus de la Influenza A/fisiología , Límite de Detección , Factores de Tiempo
12.
Biomed Microdevices ; 15(2): 339-52, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23315192

RESUMEN

Ovarian cancer is the second most common of the gynecological cancers in Taiwan. It is challenging to diagnose at an early stage when proper treatment is the most effective. It is well recognized that the detection of tumor cells (TCs) is critical for determining cancer growth stages and may provide important information for accurate diagnosis and even prognosis. In this study, a new microfluidic platform integrated with a moving-wall micro-incubator, a micro flow cytometer and a molecular diagnosis module performed automated identification of ovarian cancer cells. By efficiently mixing the cells and immunomagnetic beads coated with specific antibodies, the target TCs were successfully isolated from the clinical samples. Then counting of the target cells was achieved by a combination of the micro flow cytometer and an optical detection module and showed a counting accuracy as high as 92.5 %. Finally, cancer-associated genes were amplified and detected by the downstream molecular diagnosis module. The fluorescence intensity of specific genes (CD24 and HE4) associated with ovarian cancer was amplified by the molecular diagnosis module and the results were comparable to traditional slab-gel electrophoresis analysis, with a limit of detection around 10 TCs. This integrated microfluidic platform realized the concept of a "lab-on-a-chip" and had advantages which included automation, disposability, lower cost and rapid diagnosis and, therefore, may provide a promising approach for the fast and accurate detection of cancer cells.


Asunto(s)
Biomarcadores de Tumor/análisis , Recuento de Células/instrumentación , Separación Celular/instrumentación , Citometría de Flujo/instrumentación , Técnicas de Diagnóstico Molecular/instrumentación , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/metabolismo , Línea Celular Tumoral , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Inmunoensayo/instrumentación , Separación Inmunomagnética/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Integración de Sistemas
13.
Biosens Bioelectron ; 26(9): 3900-7, 2011 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-21466957

RESUMEN

This study reports a new immunomagnetic bead-based microfluidic system for the rapid detection of influenza A virus infection by performing a simple two-step diagnostic process that includes a magnetic bead-based fluorescent immunoassay (FIA) and an end-point optical analysis. With the incorporation of monoclonal antibody (mAb)-conjugated immunomagnetic beads, target influenza A viral particles such as A/H1N1 and A/H3N2 can be specifically recognized and are bound onto the surface of the immunomagnetic beads from the specimen sample. This is followed by labeling the fluorescent signal onto the virus-bound magnetic complexes by specific developing mAb with R-phycoerythrin (PE). Finally, the optical intensity of the magnetic complexes can be analyzed immediately by the optical detection module. Significantly, the limit of detection (LOD) of this immunomagnetic bead-based microfluidic system for the detection of influenza A virus in a specimen sample is approximately 5×10(-4) hemagglutin units (HAU), which is 1024 times better than compared to conventional bench-top systems using flow cytometry. More importantly, the entire diagnostic protocol, from the purification of target viral particles to optical detection of the magnetic complexes, can be automatically completed within 15 min in this immunomagnetic bead-based microfluidic system, which is only 8.5% of the time required when compared to a manual protocol. As a whole, this microfluidic system may provide a powerful platform for the rapid diagnosis of influenza A virus infection and may be extended for diagnosis of other types of infectious diseases with a high specificity and sensitivity.


Asunto(s)
Técnicas Biosensibles , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Subtipo H3N2 del Virus de la Influenza A/aislamiento & purificación , Gripe Humana/diagnóstico , Humanos , Subtipo H1N1 del Virus de la Influenza A/patogenicidad , Subtipo H3N2 del Virus de la Influenza A/patogenicidad , Gripe Humana/virología , Límite de Detección , Magnetismo , Técnicas Analíticas Microfluídicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA