RESUMEN
BACKGROUND: Left ventricular (LV) structural and functional changes have been reported in patients with aortic stenosis (AS) who have undergone transcatheter aortic valve implantation (TAVI); however, the relationship between change in LV structure and systolic function and tissue characteristics assessed via cardiovascular magnetic resonance imaging (CMRI) post-TAVI has been not fully elucidated. This study aimed to investigate this relationship in patients with severe AS who underwent TAVI and CMRI. METHODS: In this retrospective study, 65 patients who underwent TAVI and CMRI at the 6-month follow-up were analyzed. The relationship between percent changes in LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), LV ejection fraction (LVEF), and LV mass (LVM) (â¿LVEDV, â¿LVESV, â¿LVEF, and â¿LVM) and those in the native T1 value (â¿native T1) was analyzed using a correlation analysis. Moreover, extracellular volume fraction (ECV) value changes were analyzed. RESULTS: The â¿native T1 significantly decreased from 1292.8 (1269.9-1318.4) ms at pre-TAVI to 1282.3 (1262.6-1310.2) ms at the 6-month follow-up (P = 0.022). A significant positive correlation between â¿LVEDV, â¿LVESV, and â¿LVM and â¿native T1 (r = 0.351, P = 0.004; r = 0.339, P = 0.006; r = 0.261, P = 0.035, respectively) and a tendency toward a negative correlation between â¿LVEF and â¿native T1 (r = -0.237, P = 0.058) were observed. The ECV value increased significantly from 26.7 % (25.3-28.3) to 28.2 % (25.7-30.5) (P = 0.002). CONCLUSIONS: The decrease in native T1 might be associated with LV reverse remodeling. Evaluating structural and functional changes using CMRI may be useful for patient management.
RESUMEN
Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) can identify the lipid-rich lesions, described as high lipid-core burden index (LCBI). The aim of this study was to investigate the relation between lipid-core plaque (LCP) in the infarct-related lesion detected using NIRS-IVUS and no-reflow phenomenon during percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS). We investigated 371 patients with ACS who underwent NIRS-IVUS in the infarct-related lesions before PCI. The extent of LCP in the infarct-related lesion was calculated as the maximum LCBI for each of the 4-mm longitudinal segments (maxLCBI4mm) measured by NIRS-IVUS. The patients were divided into 2 groups using a maxLCBI4mm cut-off value of 400. The overall incidence of no-reflow phenomenon was 53 of 371 (14.3%). No-reflow phenomenon more frequently occurred in patients with maxLCBI4mm ≥400 compared with those with maxLCBI4mm<400 (17.5% vs 2.5%, p <0.001). After propensity score matching, multivariable logistic regression analysis demonstrated that maxLCBI4mm (odds ratio: 1.008; 95% confidence interval: 1.005 to 1.012, p <0.001) was independently associated with the no-reflow phenomenon. The maxLCBI4mm of 719 in the infarct-related lesion had the highest combined sensitivity (69.8%) and specificity (72.1%) for the identification of no-reflow phenomenon. In conclusion, in patients with ACS, maxLCBI4mm in the infarct-related lesion assessed by NIRS-IVUS was independently associated with the no-reflow phenomenon during PCI.