Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Chem ; 91(19): 12399-12406, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31490662

RESUMEN

Robust and highly specific methods for the detection of the protein toxin ricin are of interest to the law enforcement community. In previous studies, methods based on liquid chromatography-tandem mass spectrometry shotgun proteomics have been proposed. The successful implementation of this approach relies on specific data evaluation criteria addressing (1) the quality of the mass spectrometric data, (2) the confidence of peptide identifications (peptide-spectrum matches), and (3) the number and sequence specificity of peptides detected. We present such data evaluation criteria and use a novel approach to establish the limit of detection for this ricin assay. Specifically, we use logistic regression to determine the probability of detection for individual ricin peptides at different concentrations. We then apply basic rules from probability theory, combining these individual peptide probabilities into an overall assay limit of detection. This procedure yields an assay limit of detection for ricin at 42.5 ng on column or 21.25 ng/µL for a 2-µL injection. We also show that, despite the conventional wisdom that detergents are deleterious to mass spectrometric analyses, the presence of Tween-20 did not prevent detection of ricin peptides, and indeed assays performed in buffers that included Tween-20 gave better results than assays performed using other buffer formulations with or without detergent removal.


Asunto(s)
Límite de Detección , Proteómica/métodos , Ricina/análisis , Secuencia de Aminoácidos , Polisorbatos/química , Ricina/química , Ricina/metabolismo
2.
Toxicon ; 152: 71-77, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-30071219

RESUMEN

The majority of fatalities from poisonous mushroom ingestion are caused by amatoxins. To prevent liver failure or death, it is critical to accurately and rapidly diagnose amatoxin exposure. We have developed a liquid chromatography tandem mass spectrometry method to detect α-, ß-, and γ-amanitin in urine to meet this need. Two internal standard candidates were evaluated, including an isotopically labeled 15N10-α-amanitin and a modified amanitin methionine sulfoxide synthetic peptide. Using the 15N10-α-amanitin internal standard, precision and accuracy of α-amanitin in pooled urine was ≤5.49% and between 100 and 106%, respectively, with a reportable range from 1-200 ng/mL. ß- and γ-Amanitin were most accurately quantitated in pooled urine using external calibration, resulting in precision ≤17.2% and accuracy between 99 and 105% with calibration ranges from 2.5-200 ng/mL and 1.0-200 ng/mL, respectively. The presented urinary diagnostic test is the first method to use an isotopically labeled α-amanitin with the ability to detect and confirm human exposures to α-, ß-, and γ-amanitin.


Asunto(s)
Amanitinas/orina , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Biomarcadores/orina , Humanos , Intoxicación por Setas/diagnóstico , Isótopos de Nitrógeno
3.
Bioanalysis ; 10(4): 229-239, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29333869

RESUMEN

AIM: An immunomagnetic capture protocol for use with LC-MS was developed for the quantitation of saxitoxin (STX) in human urine. MATERIALS & METHODS: This method uses monoclonal antibodies coupled to magnetic beads. STX was certified reference material grade from National Research Council, Canada. Analysis was carried out using LC-MS. RESULTS: With an extraction efficiency of 80%, accuracy and precision of 93.0-100.2% and 5.3-12.6%, respectively, and a dynamic range of 1.00-100 ng/ml, the method is well suited to quantify STX exposures based on previously reported cases. CONCLUSION: Compared with our previously published protocols, this method has improved selectivity, a fivefold increase in sensitivity and uses only a third of the sample volume. This method can diagnose future toxin exposures and may complement the shellfish monitoring programs worldwide.


Asunto(s)
Cromatografía Liquida/métodos , Pruebas Inmunológicas , Saxitoxina/orina , Intoxicación por Mariscos/orina , Espectrometría de Masas en Tándem/métodos , Anticuerpos Monoclonales/inmunología , Calibración , Humanos , Imanes , Microesferas , Estándares de Referencia , Saxitoxina/química , Saxitoxina/normas , Intoxicación por Mariscos/diagnóstico , Factores de Tiempo
4.
Biomed Chromatogr ; 31(9)2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28186342

RESUMEN

Paralytic shellfish toxins (PSTs), including gonyautoxins and saxitoxins, are produced by multiple species of microalgae and dinoflagellates, and are bioaccumulated by shellfish and other animals. Human exposure to PSTs typically occurs through ingestion of recreationally harvested contaminated shellfish and results in nonspecific symptomology. Confirmation of exposure to PSTs has often relied on the measurement of saxitoxin, the most toxic congener; however, gonyautoxins (GTXs), the sulfated carbamate derivatives of saxitoxin, may be present in shellfish at higher concentrations. To improve identification of PST exposures, our group has developed an online solid phase extraction hydrophilic interaction liquid chromatography method to identify GTX1-4 in human urine with tandem mass spectrometry. The reportable range varied for each analyte, with all falling within 0.899 and 250 ng/mL in urine with precision <15% and >85% accuracy as determined for all quality control samples. This new online method quantitates GTX1-4 following exposures to PSTs, supporting the work of public health authorities.


Asunto(s)
Cromatografía Liquida/métodos , Saxitoxina/análogos & derivados , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Saxitoxina/química , Saxitoxina/aislamiento & purificación , Saxitoxina/orina
6.
Toxicon ; 119: 64-71, 2016 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-27212629

RESUMEN

Tetrodotoxin (TTX) is an extremely potent paralytic toxin responsible for yearly illness and death around the world. A clinical measurement is necessary to confirm exposure because symptoms of TTX intoxication cannot be distinguished from other paralytic toxins. Our group has developed an online solid phase extraction hydrophilic interaction liquid chromatography (HILIC) method for the analysis of TTX in human urine with tandem mass spectrometry. The reportable range for the method was 2.80 - 249 ng/mL in urine with precision and accuracy within 15% as determined for all quality control samples. No isotopically-labeled internal standard is available for TTX; thus a surrogate internal standard, voglibose, was investigated to compensate for matrix effects and ionization suppression. However, upon evaluation, voglibose was ineffective for this purpose. This new online method rapidly identifies TTX, facilitating the work of public health authorities and providing support to monitoring programs worldwide.


Asunto(s)
Cromatografía Liquida/métodos , Ensayos Analíticos de Alto Rendimiento , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Tetrodotoxina/orina , Calibración , Humanos , Límite de Detección , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA