1.
Biosens Bioelectron ; 16(4-5): 325-36, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11390221

RESUMEN

A novel biosensory method has been developed for the determination of various chemical and biological molecules by assessing their electrophysiological interactions with a group of cells and cell components immobilized in a gel matrix that preserves their 'physiological' functions. The method was applied for the detection of: (i) hepatitis C virus in human blood samples; (ii) plant viruses; and (iii) a herbicide (glyphosate) in aqueous solutions. It was able to rapidly (assay time 3-5 min) and specifically detect the molecules in question at a concentration lower than 100 pg/ml, among other compounds f similar structure. The potential use of BERA biosensors for a rapid and cost-efficient molecule determination without prior knowledge of a specific receptor-molecule interaction is discussed.


Asunto(s)
Técnicas Biosensibles/métodos , Animales , Supervivencia Celular , Células Inmovilizadas , Humanos