Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 251
Filtrar
1.
Circ Arrhythm Electrophysiol ; : e012826, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39234745

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a novel technology for catheter-based atrial arrhythmia treatment. Evidence of its application for ventricular arrhythmia ablation is still limited. In this study, we describe the feasibility and efficacy of focal PFA for premature ventricular contraction (PVC) ablation. METHODS: A prospective cohort of 20 patients referred for PVC ablation at 2 centers was enrolled, regardless of the presence of structural heart disease, PVC morphology, or previous ablation attempts. All procedures were performed using the CENTAURI System in combination with contact force sensing catheters and 3-dimensional electroanatomical mapping systems. Energy output and the number of applications were left to the operator's discretion. RESULTS: Eleven (55%) procedures were conducted under general anesthesia, 6 (30%) under deep sedation, and 3 (15%) under light sedation. Muscular contraction was observed in one case (5%). Median procedural and fluoroscopy times were 95.5 and 6.55 minutes, respectively. The median number of PFA applications was 8 with a median contact force of 10g. A statistically significant (76%) reduction was observed in mean peak-to-peak bipolar electrogram voltage before and after ablation (0.707 versus 0.098 mV; P=0.008). Ventricular irritative firing was observed in 11 (55%) patients after PFA. The median follow-up was 120 days. Acute procedural success was achieved in 17 of 20 (85% [95% CI, 0.70-1]) patients. Two of the patients with procedural failure had late success with >80% clinical PVC burden suppression during follow-up, and 2 of 17 patients with acute success had late PVC recurrence, which accounts for a total of 17 of 20 (85% [95% CI, 0.70-1]) patients with chronic success. Transient ST-segment depression occurred in 1 patient, and the right bundle branch block was induced in 2 others (permanently only in one case). CONCLUSIONS: PVC ablation using a focal PFA is feasible, effective, and safe, with promising acute and long-term results in several ventricular locations. Irritative firing is frequently observed. Coronary evaluation should be considered when targeting the outflow tract.

2.
Europace ; 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39228338

RESUMEN

BACKGROUND: Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using Conventional ablation settings with 20/60-second RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15 seconds (s) on the posterior wall when facing the esophageal region is as effective as applying 20 s. OBJECTIVE: To prospectively assess whether reducing RF time on PST/ANT segments to 15/45 s can ensure sufficient quality of lesion metrics and compare the new Shortened ablation settings with the Conventional one in terms of safety, and effectiveness at 1-year. METHODS: A total of 641 patients from 7 European centers were enrolled in a collaborative registry, with 374 in the conventional RF delivery group and 267 in the shortened RF delivery group. Procedural outcomes, lesion metrics, and safety profiles were assessed and compared between the groups. RESULTS: Freedom of any atrial tachycarrythmias at one year were 85.4% and 88.2% in the SHRT and CONV groups, respectively. The shortened RF delivery strategy was associated with significantly shorter procedure times (median 63.5 vs. 96.5 minutes, P < 0.001) and shortened fluoroscopy exposure (median 10.0 vs. 14.0 minutes, P < 0.001) compared to conventional delivery. Efficacy metrics, including first-pass isolation rates and time to isolation, were comparable between groups. Shortened RF delivery was associated with a lower incidence of procedural complications (1.4% vs. 5.3%, P = 0.04) and optimized thermal characteristics. CONCLUSION: Analyses from the COLLABORATE Registry demonstrate that shortening RF energy delivery times to 15/45s (PST/ANT) during PVI with the RFB resulted in comparable freedom from recurrent atrial tachyarrhythmia compared to conventional delivery times with comparable efficiency and safety.

4.
Heart Rhythm ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39117003

RESUMEN

BACKGROUND: Recurrence during the 3-month blanking period after radiofrequency ablation of atrial fibrillation (AF) is typically not considered as a predictor for late recurrence. OBJECTIVE: We investigated the significance of early recurrence as a risk factor for late recurrence in patients with AF receiving pulsed-field ablation (PFA). METHODS: Consecutive patients undergoing PFA were prospectively followed up for 1 year. All patients received isolation of pulmonary veins. Additional ablation procedures were performed per operator's discretion. After the procedure, all remained on their previously ineffective antiarrhythmic drugs (AADs) during the 2-month blanking period after which the AADs were discontinued. Early recurrence was defined as atrial arrhythmia of >30-second duration during the 3-month blanking period, and any recurrence beyond 3 months was considered as late recurrence. RESULTS: A total of 337 patients undergoing PFA for AF were included. Early recurrence was recorded in 53 patients (15.7%): 10 in the first month, 12 in the second month, and 31 in the third month. Of the 10 patients having recurrence during the first month, 7 (70%) remained in sinus rhythm after cardioversion whereas 3 (30%) underwent a redo procedure because of late recurrence. At 1 year, all patients with recurrence in the second and third months experienced late recurrence; among these patients, 10 (83.3%) of 12 and 27 (87%) of 31 underwent a redo procedure and the remaining 6 patients were in sinus rhythm on AADs. CONCLUSION: In this consecutive series of patients with AF, early recurrence in the second or third month after the PFA procedure was associated with a high risk of late recurrence. Thus, blanking period could be redefined as 1 month after PFA.

5.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39150065

RESUMEN

AIMS: Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter-tissue contact impact lesion formation during PFA. METHODS AND RESULTS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). CONCLUSION: Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter , Diseño de Equipo , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Animales , Porcinos , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Modelos Animales , Sus scrofa , Factores de Tiempo
6.
Heart Rhythm ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39197738

RESUMEN

Traditional classifications categorize atrial fibrillation (AF) into paroxysmal, persistent, or permanent, but recent advancements in monitoring have revealed AF as a continuous variable, challenging existing paradigms. AF burden, defined basically as the amount of time spent in AF during a monitored period, has emerged as a crucial metric. This review assesses the evolving landscape of AF burden and its measurement methods, diagnostic modalities, and impact on outcomes. Guidelines suggest individualized approaches, combining AF burden with clinical scores (CHA2DS2-VASc), but studies have challenged this. Addressing the impact of AF burden on patients' quality of life before or after ablation is also crucial. Although continuous monitoring technologies offer promising avenues, the field faces challenges, such as defining clinically relevant thresholds. Future research should focus on refining these, designing trials centered around AF burden, and evaluating the efficacy of interventions in reducing AF burden, ultimately paving the way for personalized management strategies.

9.
Artículo en Inglés | MEDLINE | ID: mdl-39135364

RESUMEN

INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.

11.
Circ Arrhythm Electrophysiol ; : e012732, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39212069

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is increasingly used in clinical practice for the treatment of atrial fibrillation. While the susceptibility of erythrocytes to electroporation is well established, the effect of cardiac PFA technologies on hemolysis has remained underreported. The aim of this study was to investigate the incidence, severity, and clinical impact of PFA-induced hemolysis. METHODS: We included n=145 patients undergoing atrial fibrillation catheter ablation with a pentaspline PFA catheter (biphasic, bipolar pulses of 2 kV) and n=70 patients receiving radiofrequency ablation (40-90 W) at 4 high-volume European centers. The lesion set comprised pulmonary vein isolation for paroxysmal atrial fibrillation and pulmonary vein isolation±additional lesions for persistent atrial fibrillation. Hemolysis and renal function biomarkers were analyzed in blood samples at baseline, at the end of ablation, and 24 hours after the procedure. RESULTS: Baseline characteristics were well balanced between groups (overall mean, 65.7±9.4 years; 69.3% male). The ablation procedures comprised a mean of 61.6±27.4 PFA deliveries and 26.3±15.0 minute RF duration. Hemolysis was detected in 94.3% versus 6.8% of patients after PFA versus radiofrequency ablation (P<0.001): PFA was associated with significantly lower haptoglobin levels (0.5±0.4 versus 1.0±0.4 g/L), while free plasma hemoglobin (592.8±330.6 versus 147.8±183.0 mg/L), bilirubin (21.3±11.3 versus 14.8±8.8 µmol/L), and LDH (lactate dehydrogenase, 352.7±115.7 versus 253.2±56.5 U/L) were significantly higher after PFA versus radiofrequency ablation (all P<0.001). Hemolysis correlated with the number of PFA deliveries (r=0.62 [95% CI, 0.33-0.80]; P<0.001), with the highest severity occurring ≥54 PFA deliveries. After PFA, hemoglobinuria occurred in 36.4%, while creatinine increase was higher in patients with baseline glomerular filtration rate <50 mL/min versus baseline glomerular filtration rate >50 mL/min (Δcrea, 27.0±103.1 versus -0.2±12.1 µmol/L; P=0.010). CONCLUSIONS: Intravascular hemolysis is a frequent finding after PFA and increases with the number of PFA deliveries. Until the clinical impact of PFA-associated hemolysis is fully elucidated, a careful titration of PFA deliveries during the ablation procedure is warranted.

12.
Catheter Cardiovasc Interv ; 104(2): 220-226, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38959377

RESUMEN

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.


Asunto(s)
Aterectomía Coronaria , Medios de Contraste , Enfermedad de la Arteria Coronaria , Láseres de Excímeros , Humanos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Láseres de Excímeros/uso terapéutico , Aterectomía Coronaria/efectos adversos , Resultado del Tratamiento , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Medios de Contraste/administración & dosificación , Italia , Angiografía Coronaria , Valor Predictivo de las Pruebas , Factores de Tiempo , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Stents , Factores de Riesgo
13.
Clin Res Cardiol ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958753

RESUMEN

INTRODUCTION: Drug-coated balloon (DCB) is an established treatment option for in-stent restenosis and small vessel, de novo, coronary artery disease (CAD). Although the use of this tool is increasing in everyday practice, data regarding performance in the treatment of de novo, large vessel CAD (LV-CAD) is still lacking. A systematic review and meta-analysis were conducted to evaluate the efficacy and safety of DCB versus drug-eluting stent (DES) in this setting. METHODS: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to January 24, 2024, for studies which compared the efficacy and safety of DCB versus DES in the treatment of de novo lesions in large vessels (≥ 2.5 mm), reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were cardiovascular death (CVD), myocardial infarction (MI), target lesion revascularization (TLR), all-cause death (ACD), and late lumen loss (LLL) at follow-up. The effect size was estimated using a random effects model as risk ratio (RR) and mean difference (MD) and relative 95% confidence interval (CI). RESULTS: A total of 13 studies (6 randomized controlled trials and 7 observational studies) involving 2888 patients (DCB n = 1334; DES n = 1533) with de novo LV-CAD were included in this meta-analysis following our inclusion criteria. No differences were observed between DCB and DES in terms of CVD (RR 0.49; 95% CI [0.23-1.03]; p = 0.06), MI (RR 0.48; 95% CI [0.16-1.45]; p = 0.89), TLR (RR 0.73; 95% CI [0.40-1.34]; p = 0.32), ACD (RR 0.78; 95% CI [0.57-1.07]; p = 0.12), and LLL (MD - 0.14; 95% CI [- 0.30 to 0.02]; p = 0.10) at follow-up. DES proved a higher mean acute gain versus DCB [1.94 (1.73, 2.14) vs 1.31 (1.02, 1.60); p = 0.0006]. CONCLUSION: Our meta-analysis showed that DCB PCI might provide a promising option for the management of selected, de novo LV-CAD compared to DES. However, more focused RCTs are needed to further prove the benefits of a "metal-free" strategy in this subset of CAD.

14.
Cardiology ; : 1-8, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38986462

RESUMEN

INTRODUCTION: Patients undergoing left atrial appendage occlusion (LAAO) are at increased risk for bleeding or thromboembolic events. Concurrently, biomarkers are of growing importance in risk stratification for atrial fibrillation patients. We aimed to evaluate the association of hematological markers and clinical characteristics with the occurrence of thromboembolic and bleeding events following LAAO. METHODS: Seven implanting centers retrospectively gathered data on hematological markers (i.e., platelet count [PC], mean platelet volume [MPV], and fibrinogen) prior to LAAO. Prespecified thromboembolic and major bleeding outcomes were collected and the association with pre-procedural hematological markers and clinical characteristics was evaluated using Cox regression analysis. RESULTS: In total, 1,315 patients were included (74 ± 9 years, 36% female, CHA2DS2-VASc 4.3 ± 1.5, HAS-BLED 3.3 ± 1.1). Over a total follow-up duration of 2,682 patient years, 77 thromboembolic events and 107 major bleeding events occurred after LAAO. Baseline PC was the only biomarker showing a signal for a relation to thromboembolic events (HR 1.18, 95% CI: 1.00-1.39) per 50*109 increment, p = 0.056). Thrombotic event rates, including device-related thrombus, increased within higher PC quartiles. Thromboembolism was associated with age (HR 1.05, 95% CI: 1.00-1.10, per year increase) and prior thromboembolism (HR 2.08, 95% CI: 1.07-4.03), but with none of the biomarkers in multivariate analysis. No association of any of the hematological markers with major bleeding was observed. Major bleeding following LAAO was associated with prior major bleeding (HR 5.27, 95% CI: 2.71-10.22), renal disease (HR 1.93, 95% CI: 1.17-3.18), and discharge on dual antiplatelet therapy (DAPT) (HR 1.71, 95% CI: 1.05-2.77). CONCLUSION: Most thrombotic events occurred in the highest PC quartile, but no association of any of the hematological markers with thromboembolism or major bleeding was observed in our analysis. In multivariate analysis, older age and prior thromboembolism were associated with thromboembolism. Prior major bleeding, renal disease and discharge on DAPT were multivariate predictors of major bleeding after LAAO.

16.
JACC Clin Electrophysiol ; 10(8): 1781-1790, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38878012

RESUMEN

BACKGROUND: Purkinje fibers play an important role in initiation and maintenance of ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT). Fascicular substrate modification (FSM) approaches have been suggested to treat recurrent VF in case reports and small case series. OBJECTIVES: The aim of this study was to investigate outcomes of catheter-based FSM to treat VF and PMVT. METHODS: Of 2,212 consecutive patients with ventricular arrhythmia undergoing catheter ablation, 18 (0.81%) underwent FSM of the Purkinje fibers as identified with high-density mapping during sinus rhythm. Fascicular substrate and VF initiation were mapped using a multipolar catheter. The endpoint of the ablation was noninducibility of VF and PMVT. In select patients, remapping revealed elimination of the targeted Purkinje potentials. Demographic, clinical, and follow-up characteristics were prospectively collected in our institutional database. RESULTS: A total of 18 patients (mean age 56 ± 3.8 years, 22% women) were included in the study. Of those, 11 (61.1%) had idiopathic VF, 3 (16.7%) had nonischemic cardiomyopathy, and 4 (22.2%) had mixed cardiomyopathy. The average left ventricular ejection fraction was 42.5%. At least 2 antiarrhythmic drugs had failed preablation. At baseline, all patients had inducible VF or PMVT. At the end of the procedure, no patient demonstrated new evidence of fascicular block or bundle branch block. There were no procedure-related complications. After a median follow-up period of 24 months, 16 patients (88.9%) were arrhythmia free on or off drugs: 11 of 11 patients (100%) with idiopathic VF vs 5 of 7 patients (71.4%) with underlying cardiomyopathy (P = 0.06). CONCLUSIONS: Catheter ablation of human VF and PMVT with FSM is feasible and safe and appears highly effective, with high rates of acute VF noninducibility and long-term freedom from recurrent VF.


Asunto(s)
Ablación por Catéter , Ramos Subendocárdicos , Fibrilación Ventricular , Humanos , Fibrilación Ventricular/cirugía , Fibrilación Ventricular/terapia , Fibrilación Ventricular/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ramos Subendocárdicos/fisiopatología , Ramos Subendocárdicos/cirugía , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Anciano
17.
J Med Econ ; 27(1): 826-835, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38889094

RESUMEN

BACKGROUND AND AIMS: Cardiac ablation is a well-established method for treating atrial fibrillation (AF). Pulsed field ablation (PFA) is a non-thermal therapeutic alternative to radiofrequency ablation (RFA) and cryoballoon ablation (CRYO). PFA uses high-voltage electric pulses to target cells. The present analysis aims to quantify the costs, outcomes, and resources associated with these three ablation strategies for paroxysmal AF. METHODS: Real-world clinical data were prospectively collected during index hospitalization by three European medical centers (Belgium, Germany, the Netherlands) specialized in cardiac ablation. These data included procedure times (pre-procedural, skin-to-skin and post-procedural), resource use, and staff burden. Data regarding complications associated with each of the three treatment options and redo procedures were extracted from the literature. Costs were collected from hospital economic formularies and published cost databases. A cost-consequence model from the hospital perspective was built to estimate the impact of the three treatment options in terms of effectiveness and costs. RESULTS: Across the three centers, N = 91 patients were included over a period of 12 months. A significant difference was seen in pre-procedural time (mean ± SD, PFA: 13.6 ± 3.7 min, CRYO: 18.8 ± 6.6 min, RFA: 20.4 ± 6.4 min; p < .001). Procedural time (skin-to-skin) was also different across alternatives (PFA: 50.9 ± 22.4 min, CRYO: 74.5 ± 24.5 min, RFA: 140.2 ± 82.4 min; p < .0001). The model reported an overall cost of €216,535 per 100 patients treated with PFA, €301,510 per 100 patients treated with CRYO and €346,594 per 100 patients treated with RFA. Overall, the cumulative savings associated with PFA (excluding kit costs) were €850 and €1,301 per patient compared to CRYO and RFA, respectively. CONCLUSION: PFA demonstrated shorter procedure time compared to CRYO and RFA. Model estimates indicate that these time savings result in cost savings for hospitals and reduce outlay on redo procedures. Clinical practice in individual hospitals varies and may impact the ability to transfer the results of this analysis to other settings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Análisis Costo-Beneficio , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/economía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/economía , Ablación por Catéter/métodos , Anciano , Tempo Operativo , Estudios Prospectivos , Europa (Continente) , Criocirugía/economía , Criocirugía/métodos , Complicaciones Posoperatorias/economía , Recursos en Salud/estadística & datos numéricos , Recursos en Salud/economía
18.
JACC Adv ; 3(5): 100905, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939629

RESUMEN

Background: Atrial fibrillation (AF) is the most common arrhythmia reported worldwide. There is significant heterogeneity in AF care pathways for a patient seen in the emergency room, impacting access to guideline-driven therapies. Objectives: The purpose of this study was to compare the difference in AF outcomes between those treated with an organized treatment pathway vs routine-care approach. Methods: The emergency room to electrophysiology service study (ER2EP) is a multicenter, prospective observational registry (NCT04476524) enrolling patients with AF from sites where a pathway for management of AF was put in place compared to sites where a pathway was not in place within the same health system and the same physicians providing services at all sites. Multivariable regression modeling was performed to identify predictors of clinical outcomes. Beta coefficient or odds ratio was reported as appropriate. Results: A total of 500 patients (ER2EP group, n = 250; control group, n = 250) were included in the study. The mean age was 73.4 ± 12.9 years, and 52.2% were males. There was a statistically significant difference in primary endpoint [time to ablation (56 ± 50.9 days vs 183.3 ± 109.5 days; P < 0.001), time to anticoagulation initiation (2.1 ± 1.6 days vs 19.7 ± 35 days, P < 0.001), antiarrhythmic drug initiation (4.8 ± 7.1 days vs 24.7 ± 44.4 days, P < 0.001) compared to the control group, respectively. As such, this resulted in reduced length of stay in the ER2EP group compared to the control group (2.4 ± 1.4 days vs 3.23 ± 2.5 days, P = 0.002). Conclusions: This study provides evidence that having an organized pathway from the emergency department for AF patients involving electrophysiology services can improve early access to definitive therapies and clinical outcomes.

19.
J Clin Med ; 13(12)2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38930050

RESUMEN

Background: The optimal timing to perform percutaneous coronary interventions (PCIs) in patients undergoing transcatheter aortic valve replacement (TAVR) is not well established. In this meta-analysis, we aimed to compare the outcomes of patients undergoing PCI before versus after TAVR. Methods: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to 5 April 2024 for studies that compared PCI before and after TAVR reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were mortality, stroke, and myocardial infarction (MI) at follow-up. Results: A total of 3 studies involving 1531 patients (pre-TAVR PCI n = 1240; post-TAVR PCI n = 291) were included in this meta-analysis following our inclusion criteria. Mortality was higher in the pre-TAVR PCI group (OR: 2.48; 95% CI: 1.19-5.20; p = 0.02). No differences were found between PCI before and after TAVR for the risk of stroke (OR: 3.58; 95% CI: 0.70-18.15; p = 0.12) and MI (OR: 0.66; 95% CI: 0.30-1.42; p = 0.29). Conclusions: This meta-analysis showed in patients with stable CAD undergoing TAVR that PCI after TAVR is associated with lower mortality compared with PCI before TAVR.

20.
J Cardiovasc Electrophysiol ; 35(8): 1601-1613, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38887842

RESUMEN

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.


Asunto(s)
Apéndice Atrial , Ecocardiografía Tetradimensional , Ecocardiografía Transesofágica , Flujo de Trabajo , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Valor Predictivo de las Pruebas , Cateterismo Cardíaco/instrumentación , Ultrasonografía Intervencional , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA