Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 262: 116542, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38991372

RESUMEN

Continuous glucose monitors are crucial for diabetes management, but invasive sampling, signal drift and frequent calibrations restrict their widespread usage. Microneedle sensors are emerging as a minimally-invasive platform for real-time monitoring of clinical parameters in interstitial fluid. Herein, a painless and flexible microneedle sensing patch is constructed by a mechanically-strong microneedle base and a thin layer of fluorescent hydrogel sensor for on-site, accurate, and continuous glucose monitoring. The Förster resonance energy transfer (FRET)-based hydrogel sensors are fabricated by facile photopolymerizations of acryloylated FRET pairs and glucose-specific phenylboronic acid. The optimized hydrogel sensor enables quantification of glucose with reversibility, high selectivity, and signal stability against photobleaching. Poly (ethylene glycol diacrylate)-co-polyacrylamide hydrogel is utilized as the microneedle base, facilitating effective skin piercing and biofluid extraction. The integrated microneedle sensor patch displays a sensitivity of 0.029 mM-1 in the (patho)physiological range, a low detection limit of 0.193 mM, and a response time of 7.7 min in human serum. Hypoglycemia, euglycemia and hyperglycemia are continuously monitored over 6 h simulated meal and rest activities in a porcine skin model. This microneedle sensor with high transdermal analytical performance offers a powerful tool for continuous diabetes monitoring at point-of-care settings.


Asunto(s)
Técnicas Biosensibles , Automonitorización de la Glucosa Sanguínea , Glucemia , Transferencia Resonante de Energía de Fluorescencia , Hidrogeles , Agujas , Dispositivos Electrónicos Vestibles , Humanos , Técnicas Biosensibles/instrumentación , Hidrogeles/química , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Animales , Porcinos , Polietilenglicoles/química , Límite de Detección , Resinas Acrílicas/química , Diseño de Equipo , Monitoreo Continuo de Glucosa , Ácidos Borónicos
2.
Chem Commun (Camb) ; 60(14): 1948-1951, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38284146

RESUMEN

Nucleic acids in blood are early indicators of disease that could be detected by point-of-care biosensors if sufficiently sensitive and facile sensors existed. Electrochemical hybridization assays are sensitive and specific but are limited to very short nucleic acids. We have developed a restriction enzyme-assisted electrochemical hybridization (REH) assay for improved nucleic acid detection. By incorporating target-specific restriction enzymes, we detect long nucleic acids, with performance dependent on the location of the cut site relative to the electrode surface. Thus, we have further established guidelines for REH design to serve as a generalizable platform for robust electrochemical detection of long nucleic acids.


Asunto(s)
Técnicas Biosensibles , Ácidos Nucleicos , Técnicas Electroquímicas , Hibridación de Ácido Nucleico , Electrodos
3.
Molecules ; 28(12)2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37375260

RESUMEN

One of the major challenges in the development of effective pharmaceutical formulations for oral administration is the poor solubility of active pharmaceutical ingredients. For this reason, the dissolution process and drug release from solid oral dosage forms, such as tablets, is usually thoroughly studied in order to understand the dissolution behaviour under various conditions and optimize the formulation accordingly. Standard dissolution tests used in the pharmaceutical industry provide information on the amount of drug released over time; however, these do not allow for a detailed analysis of the underlying chemical and physical mechanisms of tablet dissolution. FTIR spectroscopic imaging, by contrast, does offer the ability to study these processes with high spatial and chemical specificity. As such, the method allows us to see the chemical and physical processes which occur inside the tablet as it dissolves. In this review, the power of ATR-FTIR spectroscopic imaging is demonstrated by presenting a number of successful applications of this chemical imaging technique to dissolution and drug release studies for a range of different pharmaceutical formulations and study conditions. Understanding these processes is essential for the development of effective oral dosage forms and optimization of pharmaceutical formulations.


Asunto(s)
Diagnóstico por Imagen , Liberación de Fármacos , Solubilidad , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Comprimidos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA