Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 418
Filtrar
2.
Med Phys ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39137294

RESUMEN

BACKGROUND: The use of magnetic resonance (MR) imaging for proton therapy treatment planning is gaining attention as a highly effective method for guidance. At the core of this approach is the generation of computed tomography (CT) images from MR scans. However, the critical issue in this process is accurately aligning the MR and CT images, a task that becomes particularly challenging in frequently moving body areas, such as the head-and-neck. Misalignments in these images can result in blurred synthetic CT (sCT) images, adversely affecting the precision and effectiveness of the treatment planning. PURPOSE: This study introduces a novel network that cohesively unifies image generation and registration processes to enhance the quality and anatomical fidelity of sCTs derived from better-aligned MR images. METHODS: The approach synergizes a generation network (G) with a deformable registration network (R), optimizing them jointly in MR-to-CT synthesis. This goal is achieved by alternately minimizing the discrepancies between the generated/registered CT images and their corresponding reference CT counterparts. The generation network employs a UNet architecture, while the registration network leverages an implicit neural representation (INR) of the displacement vector fields (DVFs). We validated this method on a dataset comprising 60 head-and-neck patients, reserving 12 cases for holdout testing. RESULTS: Compared to the baseline Pix2Pix method with MAE 124.95 ± $\pm$ 30.74 HU, the proposed technique demonstrated 80.98 ± $\pm$ 7.55 HU. The unified translation-registration network produced sharper and more anatomically congruent outputs, showing superior efficacy in converting MR images to sCTs. Additionally, from a dosimetric perspective, the plan recalculated on the resulting sCTs resulted in a remarkably reduced discrepancy to the reference proton plans. CONCLUSIONS: This study conclusively demonstrates that a holistic MR-based CT synthesis approach, integrating both image-to-image translation and deformable registration, significantly improves the precision and quality of sCT generation, particularly for the challenging body area with varied anatomic changes between corresponding MR and CT.

3.
Phys Med Biol ; 69(16)2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39025115

RESUMEN

Objective.To experimentally validate two online adaptive proton therapy (APT) workflows using Gafchromic EBT3 films and optically stimulated luminescent dosimeters (OSLDs) in an anthropomorphic head-and-neck phantom.Approach.A three-field proton plan was optimized on the planning CT of the head-and-neck phantom with 2.0 Gy(RBE) per fraction prescribed to the clinical target volume. Four fractions were simulated by varying the internal anatomy of the phantom. Three distinct methods were delivered: daily APT researched by the Paul Scherrer Institute (DAPTPSI), online adaptation researched by the Massachusetts General Hospital (OAMGH), and a non-adaptive (NA) workflow. All methods were implemented and measured at PSI. DAPTPSIperformed full online replanning based on analytical dose calculation, optimizing to the same objectives as the initial treatment plan. OAMGHperformed Monte-Carlo-based online plan adaptation by only changing the fluences of a subset of proton beamlets, mimicking the planned dose distribution. NA delivered the initial plan with a couch-shift correction based on in-room imaging. For all 12 deliveries, two films and two sets of OSLDs were placed at different locations in the phantom.Main results.Both adaptive methods showed improved dosimetric results compared to NA. For film measurements in the presence of anatomical variations, the [min-max] gamma pass rates (3%/3 mm) between measured and clinically approved doses were [91.5%-96.1%], [94.0%-95.8%], and [67.2%-93.1%] for DAPTPSI, OAMGH, and NA, respectively. The OSLDs confirmed the dose calculations in terms of absolute dosimetry. Between the two adaptive workflows, OAMGHshowed improved target coverage, while DAPTPSIshowed improved normal tissue sparing, particularly relevant for the brainstem.Significance.This is the first multi-institutional study to experimentally validate two different concepts with respect to online APT workflows. It highlights their respective dosimetric advantages, particularly in managing interfractional variations in patient anatomy that cannot be addressed by non-adaptive methods, such as internal anatomy changes.


Asunto(s)
Fantasmas de Imagen , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador , Flujo de Trabajo , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Dosificación Radioterapéutica , Método de Montecarlo , Radiometría
4.
Nat Med ; 30(9): 2489-2498, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39039249

RESUMEN

For many diseases there are delays in diagnosis due to a lack of objective biomarkers for disease onset. Here, in 41,931 individuals from the United Kingdom Biobank Pharma Proteomics Project, we integrated measurements of ~3,000 plasma proteins with clinical information to derive sparse prediction models for the 10-year incidence of 218 common and rare diseases (81-6,038 cases). We then compared prediction models developed using proteomic data with models developed using either basic clinical information alone or clinical information combined with data from 37 clinical assays. The predictive performance of sparse models including as few as 5 to 20 proteins was superior to the performance of models developed using basic clinical information for 67 pathologically diverse diseases (median delta C-index = 0.07; range = 0.02-0.31). Sparse protein models further outperformed models developed using basic information combined with clinical assay data for 52 diseases, including multiple myeloma, non-Hodgkin lymphoma, motor neuron disease, pulmonary fibrosis and dilated cardiomyopathy. For multiple myeloma, single-cell RNA sequencing from bone marrow in newly diagnosed patients showed that four of the five predictor proteins were expressed specifically in plasma cells, consistent with the strong predictive power of these proteins. External replication of sparse protein models in the EPIC-Norfolk study showed good generalizability for prediction of the six diseases tested. These findings show that sparse plasma protein signatures, including both disease-specific proteins and protein predictors shared across several diseases, offer clinically useful prediction of common and rare diseases.


Asunto(s)
Proteómica , Enfermedades Raras , Humanos , Proteómica/métodos , Enfermedades Raras/sangre , Enfermedades Raras/diagnóstico , Enfermedades Raras/genética , Reino Unido/epidemiología , Femenino , Masculino , Biomarcadores/sangre , Proteínas Sanguíneas/metabolismo , Persona de Mediana Edad , Anciano , Adulto , Medición de Riesgo
5.
Radiother Oncol ; 198: 110414, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-38942120

RESUMEN

BACKGROUND AND PURPOSE: As no guidelines for pencil beam scanning (PBS) proton therapy (PT) of paediatric posterior fossa (PF) tumours exist to date, this study investigated planning techniques across European PT centres, with special considerations for brainstem and spinal cord sparing. MATERIALS AND METHODS: A survey and a treatment planning comparison were initiated across nineteen European PBS-PT centres treating paediatric patients. The survey assessed all aspects of the treatment chain, including but not limited to delineations, dose constraints and treatment planning. Each centre planned two PF tumour cases for focal irradiation, according to their own clinical practice but based on common delineations. The prescription dose was 54 Gy(RBE) for Case 1 and 59.4 Gy(RBE) for Case 2. For both cases, planning strategies and relevant dose metrics were compared. RESULTS: Seventeen (89 %) centres answered the survey, and sixteen (80 %) participated in the treatment planning comparison. In the survey, thirteen (68 %) centres reported using the European Particle Therapy Network definition for brainstem delineation. In the treatment planning study, while most centres used three beam directions, their configurations varied widely across centres. Large variations were also seen in brainstem doses, with a brainstem near maximum dose (D2%) ranging from 52.7 Gy(RBE) to 55.7 Gy(RBE) (Case 1), and from 56.8 Gy(RBE) to 60.9 Gy(RBE) (Case 2). CONCLUSION: This study assessed the European PBS-PT planning of paediatric PF tumours. Agreement was achieved in e.g. delineation-practice, while wider variations were observed in planning approach and consequently dose to organs at risk. Collaboration between centres is still ongoing, striving towards common guidelines.


Asunto(s)
Neoplasias Infratentoriales , Terapia de Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Terapia de Protones/métodos , Neoplasias Infratentoriales/radioterapia , Europa (Continente) , Niño , Planificación de la Radioterapia Asistida por Computador/métodos , Preescolar , Masculino , Femenino , Órganos en Riesgo/efectos de la radiación , Tronco Encefálico/efectos de la radiación
6.
Obes Surg ; 34(7): 2467-2474, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38753264

RESUMEN

PURPOSE: Obesity exerts negative effects on pulmonary function through proven mechanical and biochemical pathways. Multiple studies have suggested that bariatric surgery can improve lung function. However, the timing of these effects on lung function and its association with patient reported outcomes is not known. MATERIALS AND METHODS: A prospective cohort study of patients undergoing laparoscopic sleeve gastrectomy (LSG) at a tertiary care hospital was undertaken. Spirometry tests, laboratory tests, and self-reported questionnaires on asthma symptoms and asthma control (ACQ and ACT) were administered. All data were recorded pre-operatively (T0) and every 3 months post-operatively for 1 year (T3, T6, T9, T12) and were compared using a mixed-models approach for repeated measures. RESULTS: For the 23 participants, mean age was 44.2 ± 12.3 years, mean BMI was 45.2 ± 7.2 kg/m2, 18(78%) were female, 9(39%) self-reported as non-white and 6(26%) reported to have asthma. Following LSG, % total body weight loss was significant at all follow-up points (P < 0.0001). Rapid improvement in forced expiratory volume (FEV)% predicted and forced vital capacity (FVC)% predicted was seen at T3. Although the overall ACQ and ACT score remained within normal range throughout the study, shortness of breath declined significantly at 3 months post-op (P < 0.05) and wheezing resolved for all patients by twelve months. Patients also reported reduced frequency of sleep interruption and inability to exercise by the end of the study (P < 0.05). CONCLUSION: Improvements in objective lung function assessments and patient-reported respiratory outcomes begin as early as 3 months and continue until 12 months after sleeve gastrectomy.


Asunto(s)
Gastrectomía , Obesidad Mórbida , Medición de Resultados Informados por el Paciente , Pérdida de Peso , Humanos , Femenino , Masculino , Adulto , Estudios Prospectivos , Obesidad Mórbida/cirugía , Obesidad Mórbida/fisiopatología , Obesidad Mórbida/complicaciones , Gastrectomía/métodos , Pérdida de Peso/fisiología , Persona de Mediana Edad , Volumen Espiratorio Forzado , Pulmón/fisiopatología , Capacidad Vital , Asma/fisiopatología , Resultado del Tratamiento , Laparoscopía , Pruebas de Función Respiratoria
7.
Phys Med ; 122: 103386, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38805762

RESUMEN

PURPOSE: Head and neck cancer (HNC) patients in radiotherapy require adaptive treatment plans due to anatomical changes. Deformable image registration (DIR) is used in adaptive radiotherapy, e.g. for deformable dose accumulation (DDA). However, DIR's ill-posedness necessitates addressing uncertainties, often overlooked in clinical implementations. DIR's further clinical implementation is hindered by missing quantitative commissioning and quality assurance tools. This study evaluates one pathway for more quantitative DDA uncertainties. METHODS: For five HNC patients, each with multiple repeated CTs acquired during treatment, a simultaneous-integrated boost (SIB) plan was optimized. Recalculated doses were warped individually using multiple DIRs from repeated to reference CTs, and voxel-by-voxel dose ranges determined an error-bar for DDA. Followed by evaluating, a previously proposed early-stage DDA uncertainty estimation method tested for lung cancer, which combines geometric DIR uncertainties, dose gradients and their directional dependence, in the context of HNC. RESULTS: Applying multiple DIRs show dose differences, pronounced in high dose gradient regions. The patient with largest anatomical changes (-13.1 % in ROI body volume), exhibited 33 % maximum uncertainty in contralateral parotid, with 54 % of voxels presenting an uncertainty >5 %. Accumulation over multiple CTs partially mitigated uncertainties. The estimation approach predicted 92.6 % of voxels within ±5 % to the reference dose uncertainty across all patients. CONCLUSIONS: DIR variations impact accumulated doses, emphasizing DDA uncertainty quantification's importance for HNC patients. Multiple DIR dose warping aids in quantifying DDA uncertainties. An estimation approach previously described for lung cancer was successfully validated for HNC, for SIB plans, presenting different dose gradients, and for accumulated treatments.


Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Dosis de Radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Incertidumbre , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X
8.
Radiother Oncol ; 196: 110293, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38653379

RESUMEN

The evidence for the value of particle therapy (PT) is still sparse. While randomized trials remain a cornerstone for robust comparisons with photon-based radiotherapy, data registries collecting real-world data can play a crucial role in building evidence for new developments. This Perspective describes how the European Particle Therapy Network (EPTN) is actively working on establishing a prospective data registry encompassing all patients undergoing PT in European centers. Several obstacles and hurdles are discussed, for instance harmonization of nomenclature and structure of technical and dosimetric data and data protection issues. A preferred approach is the adoption of a federated data registry model with transparent and agile governance to meet European requirements for data protection, transfer, and processing. Funding of the registry, especially for operation after the initial setup process, remains a major challenge.


Asunto(s)
Sistema de Registros , Humanos , Europa (Continente) , Estudios Prospectivos , Neoplasias/radioterapia , Terapia de Protones
9.
Phys Med Biol ; 69(9)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38537287

RESUMEN

Objective.Online magnetic resonance imaging (MRI) guidance could be especially beneficial for pencil beam scanned (PBS) proton therapy of tumours affected by respiratory motion. For the first time to our knowledge, we investigate the dosimetric impact of respiratory motion on MRI-guided proton therapy compared to the scenario without magnetic field.Approach.A previously developed analytical proton dose calculation algorithm accounting for perpendicular magnetic fields was extended to enable 4D dose calculations. For two geometrical phantoms and three liver and two lung patient cases, static treatment plans were optimised with and without magnetic field (0, 0.5 and 1.5 T). Furthermore, plans were optimised using gantry angle corrections (0.5 T +5° and 1.5 T +15°) to reproduce similar beam trajectories compared to the 0 T reference plans. The effect of motion was then considered using 4D dose calculations without any motion mitigation and simulating 8-times volumetric rescanning, with motion for the patient cases provided by 4DCT(MRI) data sets. Each 4D dose calculation was performed for different starting phases and the CTV dose coverageV95%and homogeneityD5%-D95%were analysed.Main results.For the geometrical phantoms with rigid motion perpendicular to the beam and parallel to the magnetic field, a comparable dosimetric effect was observed independent of the magnetic field. Also for the five 4DCT(MRI) cases, the influence of motion was comparable for all magnetic field strengths with and without gantry angle correction. On average, the motion-induced decrease in CTVV95%from the static plan was 17.0% and 18.9% for 1.5 T and 0.5 T, respectively, and 19.9% without magnetic field.Significance.For the first time, this study investigates the combined impact of magnetic fields and respiratory motion on MR-guided proton therapy. The comparable dosimetric effects irrespective of magnetic field strength indicate that the effects of motion for future MR-guided proton therapy may not be worse than for conventional PBS proton therapy.


Asunto(s)
Neoplasias Pulmonares , Terapia de Protones , Humanos , Terapia de Protones/métodos , Movimiento (Física) , Radiometría/métodos , Protones , Imagen por Resonancia Magnética/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia
10.
Radiother Oncol ; 196: 110227, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38492671

RESUMEN

BACKGROUND AND PURPOSE: Treatment of patients with atypical teratoid/rhabdoid (AT/RT) is challenging, especially when very young (below the age of three years). Radiotherapy (RT) is part of a complex trimodality therapy. The purpose of this guideline is to provide appropriate recommendations for RT in the clinical management of patients not enrolled in clinical trials. MATERIALS AND METHODS: Nine European experts were nominated to form a European Society for Radiotherapy and Oncology (ESTRO) guideline committee. A systematic literature search was conducted in PubMed/MEDLINE and Web of Science. They discussed and analyzed the evidence concerning the role of RT in the clinical management of AT/RT. RESULTS: Recommendations on diagnostic imaging, therapeutic principles, RT considerations regarding timing, dose, techniques, target volume definitions, dose constraints of radiation-sensitive organs at risk, concomitant chemotherapy, and follow-up were considered. Treating children with AT/RT within the framework of prospective trials or prospective registries is of utmost importance. CONCLUSION: The present guideline summarizes the evidence and clinical-based recommendations for RT in patients with AT/RT. Prospective clinical trials and international, large registries evaluating modern treatment approaches will contribute to a better understanding of the best treatment for these children in future.


Asunto(s)
Tumor Rabdoide , Teratoma , Humanos , Tumor Rabdoide/radioterapia , Tumor Rabdoide/terapia , Teratoma/radioterapia , Dosificación Radioterapéutica , Preescolar , Lactante
11.
Eye (Lond) ; 38(4): 680-686, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38302533

RESUMEN

BACKGROUND/OBJECTIVES: A national study was undertaken through the British ophthalmology surveillance unit (BOSU) to determine the incidence, presenting features and management of essential infantile esotropia (EIE) in the UK. METHODS: Data from a prospective national observational study of newly diagnosed EIE presenting to clinicians in the United Kingdom over a 12-month period were collected. Cases with a confirmed diagnosis by a clinician of a constant, non-accommodative esotropia ≥20 prism dioptres (PD), presenting at ≤12 months, with no neurological or ocular abnormalities were identified through BOSU. Follow-up data were collected at 12 months. RESULTS: A total of 57 cases were reported giving an incidence of EIE of 1 in 12,828 live births. The mean age of diagnosis and intervention were 7.05 ± 2.6 months (range 2-12) and 14.7 ± 4.9 months (range 6.5-28.1), respectively. Management was surgical in 59.6%, botulinum toxin alone in 22.8%, and 17.5% were observed. The preoperative angle of esotropia was smaller in the observation group (P = 0.04). The postoperative angle of esotropia was not statistically significant between botulinum toxin or surgery (P = 0.3), although the age of intervention was earlier in the botulinum group (P = 0.007). Early intervention (before 12 months of age) did not influence the post-intervention motor outcomes between 0 and 10 prism dioptres of esotropia (P = 0.78). CONCLUSIONS: The incidence of EIE in the UK is considerably lower than reported in other population-based studies. The preferred method of treatment was surgical with earlier intervention in those treated with botulinum toxin. An early age of intervention (<12 months) did not influence motor outcomes.


Asunto(s)
Toxinas Botulínicas Tipo A , Esotropía , Oftalmología , Humanos , Lactante , Esotropía/diagnóstico , Esotropía/epidemiología , Esotropía/terapia , Toxinas Botulínicas Tipo A/uso terapéutico , Incidencia , Estudios Prospectivos , Visión Binocular , Músculos Oculomotores/cirugía , Procedimientos Quirúrgicos Oftalmológicos , Resultado del Tratamiento , Reino Unido/epidemiología , Estudios Retrospectivos
12.
J Viral Hepat ; 31(5): 266-270, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38366329

RESUMEN

Dried blood spots (DBS) have emerged as a promising alternative to traditional venous blood for hepatitis C virus (HCV) testing. However, their capacity to accurately reflect the genetic diversity of HCV remains poorly understood. We employed deep sequencing and advanced phylogenetic analyses on paired plasma and DBS samples from two common subtypes to evaluate the suitability of DBS for genomic surveillance. Results demonstrated that DBS captured equivalent viral diversity compared to plasma with no phylogenetic discordance observed. The ability of DBS to accurately reflect the profile of viral genetic diversity suggests it may be a promising avenue for future surveillance efforts to curb HCV outbreaks.


Asunto(s)
Hepacivirus , Hepatitis C , Humanos , Hepacivirus/genética , Filogenia , Anticuerpos contra la Hepatitis C , Sensibilidad y Especificidad , Hepatitis C/diagnóstico , Hepatitis C/epidemiología , Genómica
13.
Biomed Phys Eng Express ; 10(2)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38241732

RESUMEN

Range uncertainties remain a limitation for the confined dose distribution that proton therapy can offer. The uncertainty stems from the ambiguity when translating CT Hounsfield Units (HU) into proton stopping powers. Proton Radiography (PR) can be used to verify the proton range. Specifically, PR can be used as a quality-control tool for CBCT-based synthetic CTs. An essential part of the work illustrating the potential of PR has been conducted using multi-layer ionization chamber (MLIC) detectors and mono-energetic PR. Due to the dimensions of commercially available MLICs, clinical adoption is cumbersome. Here, we present a simulation framework exploring locally-tuned single energy (LTSE) proton radiography and corresponding potential compact PR detector designs. Based on a planning CT data set, the presented framework models the water equivalent thickness. Subsequently, it analyses the proton energies required to pass through the geometry within a defined ROI. In the final step, an LTSE PR is simulated using the MCsquare Monte Carlo code. In an anatomical head phantom, we illustrate that LTSE PR allows for a significantly shorter longitudinal dimension of MLICs. We compared PR simulations for two exemplary 30 × 30 mm2proton fields passing the phantom at a 90° angle at an anterior and a posterior location in an iso-centric setup. The longitudinal distance over which all spots per field range out is significantly reduced for LTSE PR compared to mono-energetic PR. In addition, we illustrate the difference in shape of integral depth dose (IDD) when using constrained PR energies. Finally, we demonstrate the accordance of simulated and experimentally acquired IDDs for an LTSE PR acquisition. As the next steps, the framework will be used to investigate the sensitivity of LTSE PR to various sources of errors. Furthermore, we will use the framework to systematically explore the dimensions of an optimized MLIC design for daily clinical use.


Asunto(s)
Terapia de Protones , Protones , Radiografía , Simulación por Computador , Fantasmas de Imagen
14.
Phys Med ; 118: 103301, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38290179

RESUMEN

PURPOSE: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. METHODS: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries. We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. RESULTS: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10-5 coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. The results indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for the clinical application, CONCLUSIONS:: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for future clinical application.


Asunto(s)
Terapia de Protones , Protones , Estudios de Factibilidad , Tomografía de Emisión de Positrones , Terapia de Protones/métodos , Fantasmas de Imagen , Método de Montecarlo
15.
Phys Imaging Radiat Oncol ; 29: 100531, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38292650

RESUMEN

Background and purpose: Respiratory suppression techniques represent an effective motion mitigation strategy for 4D-irradiation of lung tumors with protons. A magnetic resonance imaging (MRI)-based study applied and analyzed methods for this purpose, including enhanced Deep-Inspiration-Breath-Hold (eDIBH). Twenty-one healthy volunteers (41-58 years) underwent thoracic MR scans in four imaging sessions containing two eDIBH-guided MRIs per session to simulate motion-dependent irradiation conditions. The automated MRI segmentation algorithm presented here was critical in determining the lung volumes (LVs) achieved during eDIBH. Materials and methods: The study included 168 MRIs acquired under eDIBH conditions. The lung segmentation algorithm consisted of four analysis steps: (i) image preprocessing, (ii) MRI histogram analysis with thresholding, (iii) automatic segmentation, (iv) 3D-clustering. To validate the algorithm, 46 eDIBH-MRIs were manually contoured. Sørensen-Dice similarity coefficients (DSCs) and relative deviations of LVs were determined as similarity measures. Assessment of intrasessional and intersessional LV variations and their differences provided estimates of statistical and systematic errors. Results: Lung segmentation time for 100 2D-MRI planes was âˆ¼ 10 s. Compared to manual lung contouring, the median DSC was 0.94 with a lower 95 % confidence level (CL) of 0.92. The relative volume deviations yielded a median value of 0.059 and 95 % CLs of -0.013 and 0.13. Artifact-based volume errors, mainly of the trachea, were estimated. Estimated statistical and systematic errors ranged between 6 and 8 %. Conclusions: The presented analytical algorithm is fast, precise, and readily available. The results are comparable to time-consuming, manual segmentations and other automatic segmentation approaches. Post-processing to remove image artifacts is under development.

16.
Radiother Oncol ; 190: 109973, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37913953

RESUMEN

BACKGROUND AND PURPOSE: This study investigates whether combined proton-photon therapy (CPPT) improves treatment plan quality compared to single-modality intensity-modulated radiation therapy (IMRT) or intensity-modulated proton therapy (IMPT) for head and neck cancer (HNC) patients. Different proton beam arrangements for CPPT and IMPT are compared, which could be of specific interest concerning potential future upright-positioned treatments. Furthermore, it is evaluated if CPPT benefits remain under inter-fractional anatomical changes for HNC treatments. MATERIAL AND METHODS: Five HNC patients with a planning CT and multiple (4-7) repeated CTs were studied. CPPT with simultaneously optimized photon and proton fluence, single-modality IMPT, and IMRT treatment plans were optimized on the planning CT and then recalculated and reoptimized on each repeated CT. For CPPT and IMPT, plans with different degrees of freedom for the proton beams were optimized. Fixed horizontal proton beam line (FHB), gantry-like, and arc-like plans were compared. RESULTS: The target coverage for CPPT without adaptation is insufficient (average V95%=88.4 %), while adapted plans can recover the initial treatment plan quality for target (average V95%=95.5 %) and organs-at-risk. CPPT with increased proton beam flexibility increases plan quality and reduces normal tissue complication probability of Xerostomia and Dysphagia. On average, Xerostomia NTCP reductions compared to IMRT are -2.7 %/-3.4 %/-5.0 % for CPPT FHB/CPPT Gantry/CPPT Arc. The differences for IMPT FHB/IMPT Gantry/IMPT Arc are + 0.8 %/-0.9 %/-4.3 %. CONCLUSION: CPPT for HNC needs adaptive treatments. Increasing proton beam flexibility in CPPT, either by using a gantry or an upright-positioned patient, improves treatment plan quality. However, the photon component is substantially reduced, therefore, the balance between improved plan quality and costs must be further determined.


Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Xerostomía , Humanos , Terapia de Protones/efectos adversos , Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/etiología , Radioterapia de Intensidad Modulada/efectos adversos , Órganos en Riesgo , Xerostomía/etiología
17.
Emerg Infect Dis ; 30(1): 163-167, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38063078

RESUMEN

We detected a novel GII.4 variant with an amino acid insertion at the start of epitope A in viral protein 1 of noroviruses from the United States, Gabon, South Africa, and the United Kingdom collected during 2017-2022. Early identification of GII.4 variants is crucial for assessing pandemic potential and informing vaccine development.


Asunto(s)
Infecciones por Caliciviridae , Gastroenteritis , Norovirus , Humanos , Gastroenteritis/epidemiología , Norovirus/genética , Infecciones por Caliciviridae/epidemiología , Genotipo , Pandemias , Filogenia
18.
Med Phys ; 51(1): 579-590, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37166067

RESUMEN

BACKGROUND: Numerical 4D phantoms, together with associated ground truth motion, offer a flexible and comprehensive data set for realistic simulations in radiotherapy and radiology in target sites affected by respiratory motion. PURPOSE: We present an openly available upgrade to previously reported methods for generating realistic 4DCT lung numerical phantoms, which now incorporate respiratory ribcage motion and improved lung density representation throughout the breathing cycle. METHODS: Density information of reference CTs, toget her with motion from multiple breathing cycle 4DMRIs have been combined to generate synthetic 4DCTs (4DCT(MRI)s). Inter-subject correspondence between the CT and MRI anatomy was first established via deformable image registration (DIR) of binary masks of the lungs and ribcage. Ribcage and lung motions were extracted independently from the 4DMRIs using DIR and applied to the corresponding locations in the CT after post-processing to preserve sliding organ motion. In addition, based on the Jacobian determinant of the resulting deformation vector fields, lung densities were scaled on a voxel-wise basis to more accurately represent changes in local lung density. For validating this process, synthetic 4DCTs, referred to as 4DCT(CT)s, were compared to the originating 4DCTs using motion extracted from the latter, and the dosimetric impact of the new features of ribcage motion and density correction were analyzed using pencil beam scanned proton 4D dose calculations. RESULTS: Lung density scaling led to a reduction of maximum mean lung Hounsfield units (HU) differences from 45 to 12 HU when comparing simulated 4DCT(CT)s to their originating 4DCTs. Comparing 4D dose distributions calculated on the enhanced 4DCT(CT)s to those on the original 4DCTs yielded 2%/2 mm gamma pass rates above 97% with an average improvement of 1.4% compared to previously reported phantoms. CONCLUSIONS: A previously reported 4DCT(MRI) workflow has been successfully improved and the resulting numerical phantoms exhibit more accurate lung density representations and realistic ribcage motion.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Humanos , Tomografía Computarizada Cuatridimensional/métodos , Pulmón/diagnóstico por imagen , Radiometría/métodos , Respiración , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos
19.
Int J Part Ther ; 10(2): 73-84, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38075481

RESUMEN

Purpose: To assess clinical outcomes of adolescents and young adults (AYAs) with head and neck sarcomas (HNSs) treated with pencil beam scanning proton therapy (PBSPT) and to report quality of life (QoL). Materials and Methods: Twenty-eight AYAs (aged 15 to 39 years) with HNS treated between January 2001 and July 2022 at our institution were included. The median age was 21.6 years. Rhabdomyosarcoma (39.3%), Ewing sarcoma (17.9%), chondrosarcoma (14.3%), and osteosarcoma (14.3%) were the most frequent diagnoses. Three (10.7%) patients were metastatic before PBSPT and 13 (46.4%) patients had a tumor with intracranial extension. The median total radiation dose was 63 GyRBE (range, 45 to 74 GyRBE). Thirteen (46.4%) patients received concomitant chemotherapy. Toxicity was reported according to the Common Terminology Criteria for Adverse Events (CTCAE), version 5.0 (US National Institutes of Health, Bethesda, Maryland). Survival was estimated using the Kaplan-Meier method. QoL was assessed using a PEDQOL (Pediatric Quality of Life Questionnaire) questionnaire. Self-reported outcomes were assessed using institutional questionnaires. Results: With a median follow-up of 57 months (range, 3.7 to 243 months), 5 patients (17.8%) had local failure (LF) only, 2 (7.1%) experienced distant failure (DF) only, and 2 (7.1%) had LF and DF. The estimated 5-year local control (LC) and distant control (DC) rates were 71.8% and 80.5%, respectively. The median times to LF and DF were 13.4 and 22.2 months, respectively. Four (14.3%) patients died, all but one from their HNS. Estimated 5-year overall survival was 90.7%. Six (21.4%) patients developed nonocular grade ≥3 toxicity, which consisted of otitis media (n = 2), hearing impairment (n = 2), osteoradionecrosis (n = 1), and sinusitis (n = 1). Four (14.3%) patients developed cataracts that required surgery. The 5-year freedom from nonocular grade 3 toxicity was 91.1%. No grade 4 or higher toxicity was observed. Adolescents rated their quality of life before treatment worse than their parents did. Conclusion: Excellent outcomes with acceptable late-toxicity rates were observed for AYAs with HNS after PBSPT.

20.
NPJ Precis Oncol ; 7(1): 135, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38092866

RESUMEN

Multiple genomic and proteomic studies have suggested that peripheral blood mononuclear cells (PBMCs) respond to tumor secretomes and thus could provide possible avenues for tumor prognosis and treatment evaluation. We hypothesized that the chromatin organization of PBMCs obtained from liquid biopsies, which integrates secretome signals with gene expression programs, provides efficient biomarkers to characterize tumor signals and the efficacy of proton therapy in tumor patients. Here, we show that chromatin imaging of PBMCs combined with machine learning methods provides such robust and predictive chromatin biomarkers. We show that such chromatin biomarkers enable the classification of 10 healthy and 10 pan-tumor patients. Furthermore, we extended our pipeline to assess the tumor types and states of 30 tumor patients undergoing (proton) radiation therapy. We show that our pipeline can thereby accurately distinguish between three tumor groups with up to 89% accuracy and enables the monitoring of the treatment effects. Collectively, we show the potential of chromatin biomarkers for cancer diagnostics and therapy evaluation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA