Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Bioorg Med Chem Lett ; 27(9): 2069-2073, 2017 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28284804

RESUMEN

Glucokinase (GK, hexokinase IV) is a unique hexokinase that plays a central role in mammalian glucose homeostasis. Glucose phosphorylation by GK in the pancreatic ß-cell is the rate-limiting step that controls glucose-stimulated insulin secretion. Similarly, GK-mediated glucose phosphorylation in hepatocytes plays a major role in increasing hepatic glucose uptake and metabolism and possibly lowering hepatic glucose output. Small molecule GK activators (GKAs) have been identified that increase enzyme activity by binding to an allosteric site. GKAs offer a novel approach for the treatment of Type 2 Diabetes Mellitus (T2DM) and as such have garnered much attention. We now report the design, synthesis, and biological evaluation of a novel series of 2,5,6-trisubstituted indole derivatives that act as highly potent GKAs. Among them, Compound 1 was found to possess high in vitro potency, excellent physicochemical properties, and good pharmacokinetic profile in rodents. Oral administration of Compound 1 at doses as low as 0.03mg/kg led to robust blood glucose lowering efficacy in 3week high fat diet-fed mice.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Activadores de Enzimas/química , Activadores de Enzimas/uso terapéutico , Glucoquinasa/metabolismo , Hipoglucemiantes/química , Hipoglucemiantes/uso terapéutico , Indoles/química , Indoles/uso terapéutico , Regulación Alostérica/efectos de los fármacos , Animales , Glucemia/análisis , Glucemia/metabolismo , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/metabolismo , Diseño de Fármacos , Activación Enzimática/efectos de los fármacos , Activadores de Enzimas/farmacocinética , Activadores de Enzimas/farmacología , Humanos , Hipoglucemiantes/farmacocinética , Hipoglucemiantes/farmacología , Indoles/farmacocinética , Indoles/farmacología , Insulina/sangre , Insulina/metabolismo , Ratones , Ratones Endogámicos C57BL
2.
Bioorg Med Chem Lett ; 27(9): 2063-2068, 2017 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28284809

RESUMEN

Systemically acting glucokinase activators (GKA) have been demonstrated in clinical trials to effectively lower blood glucose in patients with type II diabetes. However, mechanism-based hypoglycemia is a major adverse effect that limits the therapeutic potential of these agents. We hypothesized that the predominant mechanism leading to hypoglycemia is GKA-induced excessive insulin secretion from pancreatic ß-cells at (sub-)euglycemic levels. We further hypothesized that restricting GK activation to hepatocytes would maintain glucose-lowering efficacy while significantly reducing hypoglycemic risk. Here we report the discovery of a novel series of carboxylic acid substituted GKAs based on pyridine-2-carboxamide. These GKAs exhibit preferential distribution to the liver versus the pancreas in mice. SAR studies led to the identification of a potent and orally active hepatoselective GKA, compound 6. GKA 6 demonstrated robust glucose lowering efficacy in high fat diet-fed mice at doses ⩾10mpk, with ⩾70-fold liver:pancreas distribution, minimal effects on plasma insulin levels, and significantly reduced risk of hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Activadores de Enzimas/farmacología , Glucoquinasa/metabolismo , Hipoglucemiantes/farmacología , Piridinas/farmacología , Animales , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/metabolismo , Descubrimiento de Drogas , Activadores de Enzimas/química , Activadores de Enzimas/farmacocinética , Activadores de Enzimas/uso terapéutico , Humanos , Hipoglucemiantes/química , Hipoglucemiantes/farmacocinética , Hipoglucemiantes/uso terapéutico , Insulina/sangre , Hígado/efectos de los fármacos , Hígado/metabolismo , Ratones , Ratones Endogámicos C57BL , Páncreas/efectos de los fármacos , Páncreas/metabolismo , Piridinas/química , Piridinas/farmacocinética , Piridinas/uso terapéutico
3.
J Med Chem ; 52(16): 5009-12, 2009 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-19645482
4.
Bioorg Med Chem Lett ; 19(18): 5314-20, 2009 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-19682899

RESUMEN

3,3-Disubstituted piperidine-derived trisubstituted urea entA-2b was discovered as a highly potent and selective soluble epoxide hydrolase (sEH) inhibitor. Despite the good compound oral exposure, excellent sEH inhibition in whole blood, and remarkable selectivity, compound entA-2b failed to lower blood pressure acutely in spontaneously hypertensive rats (SHRs). This observation further challenges the premise that sEH inhibition can provide a viable approach to the treatment of hypertensive patients.


Asunto(s)
Epóxido Hidrolasas/antagonistas & inhibidores , Epóxido Hidrolasas/metabolismo , Hipertensión/tratamiento farmacológico , Piperidinas/química , Urea/análogos & derivados , Urea/farmacología , Ácido 8,11,14-Eicosatrienoico/análogos & derivados , Ácido 8,11,14-Eicosatrienoico/sangre , Ácido 8,11,14-Eicosatrienoico/metabolismo , Animales , Presión Sanguínea/efectos de los fármacos , Humanos , Modelos Moleculares , Unión Proteica , Ratas , Ratas Endogámicas SHR , Relación Estructura-Actividad , Urea/uso terapéutico
5.
Bioorg Med Chem Lett ; 19(13): 3398-404, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19481932

RESUMEN

Spirocyclic secondary amine-derived trisubstituted ureas were identified as highly potent, bioavailable and selective soluble epoxide hydrolase (sEH) inhibitors. Despite good oral exposure and excellent ex vivo target engagement in blood, one such compound, rac-1a, failed to lower blood pressure acutely in spontaneously hypertensive rats (SHRs). This study posed the question as to whether sEH inhibition provides a robust mechanism leading to a significant antihypertensive effect.


Asunto(s)
Aminas/química , Antihipertensivos/síntesis química , Inhibidores Enzimáticos/síntesis química , Epóxido Hidrolasas/antagonistas & inhibidores , Compuestos de Espiro/química , Urea/análogos & derivados , Animales , Antihipertensivos/química , Antihipertensivos/farmacocinética , Línea Celular , Descubrimiento de Drogas , Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/farmacocinética , Epóxido Hidrolasas/metabolismo , Humanos , Ratas , Ratas Endogámicas SHR , Relación Estructura-Actividad , Urea/síntesis química , Urea/farmacocinética
6.
Anal Chem ; 77(23): 7816-25, 2005 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-16316193

RESUMEN

Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC-MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC-MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC-MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.


Asunto(s)
Cromatografía Liquida/métodos , Péptidos/análisis , Péptidos/química , Proteómica/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Proteínas de Escherichia coli/química , Datos de Secuencia Molecular , Proteoma/química
7.
Anal Chem ; 77(8): 2323-31, 2005 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-15828764

RESUMEN

High-speed, high-resolution LC separations, using a poly(styrene-divinylbenzene) monolithic column, have been coupled to MALDI MS and MS/MS through an off-line continuous deposition interface. The LC eluent was mixed with alpha-cyano-4-hydroxycinnamic acid matrix solution and deposited on a MALDI plate that had been precoated with nitrocellulose. Deposition at subatmospheric pressure (80 Torr) formed a 250-microm-wide serpentine trace with uniform width and microcrystalline morphology. The deposited trace was then analyzed in the MS mode using a MALDI-TOF/TOF MS instrument. Continuous deposition allowed interrogation of the separation with a high data sampling rate in the chromatographic dimensions, thus preserving the high resolution of narrow peaks (3-5-s peak width at half-height) of the fast monolithic LC. No extracolumn band broadening due to the deposition process was observed. Over 2000 components were resolved in a 10-min linear gradient separation of the model sample, and 386 unique peptides were identified in the subsequent MS/MS analysis. The continuous deposition interface allows the coupling of high-resolution separations to MALDI MS without degradation in separation efficiency, thus enabling high-throughput proteome analysis.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Proteómica/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Secuencia de Aminoácidos , Cromatografía Líquida de Alta Presión/instrumentación , Ácidos Cumáricos/química , Electroforesis Capilar/métodos , Electroforesis en Gel de Poliacrilamida/instrumentación , Electroforesis en Gel de Poliacrilamida/métodos , Diseño de Equipo , Microscopía Electrónica de Rastreo , Datos de Secuencia Molecular , Péptidos/análisis , Péptidos/aislamiento & purificación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Temperatura , Levaduras/química
8.
Anal Chem ; 77(7): 2085-96, 2005 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-15801742

RESUMEN

The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF/TOF MS. Part 1 of the study was focused on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. In part 2, various derivatization approaches for the improvement of peptide fragmentation efficiency in MALDI-TOF/TOF MS are explored. We demonstrate that permanent cation tags, while significantly improving signal intensity in the MS mode, lead to severe suppression of MS/MS fragmentation, making these tags unsuitable for high-throughput MALDI-TOF/TOF MS analysis. In the present work, it was found that labeling with Alexa Fluor 350, a coumarin tag containing a sulfo group, along with guanidation of epsilon-amino groups of Lys, could enhance unimolecular fragmentation of peptides with the formation of a high-intensity y-ion series, while the peptide intensities in the MS mode were not severely affected. LC-MALDI-TOF/TOF MS analysis of tryptic peptides from the SCX fractions of an E. coli lysate revealed improved peptide scores, a doubling of the total number of peptides, and a 30% increase in the number of proteins identified, as a result of labeling. Furthermore, by combining the data from native and labeled samples, confidence in correct identification was increased, as many proteins were identified by different peptides in the native and labeled data sets. Additionally, derivatization was found not to impair chromatographic behavior of peptides. All these factors suggest that labeling with Alexa Fluor 350 is a promising approach to the high-throughput LC-MALDI-TOF/TOF MS analysis of proteomic samples.


Asunto(s)
Acetatos/química , Cromonas/química , Cumarinas/química , Péptidos/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Cationes , Cromatografía Liquida/métodos , Proteínas de Escherichia coli/análisis , Proteínas de Escherichia coli/química , Proteínas de Escherichia coli/metabolismo , Espectrometría de Masas/métodos , Péptidos/química
9.
Anal Chem ; 76(20): 6017-28, 2004 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-15481949

RESUMEN

This paper presents application of sequential enhanced data processing procedures to high-resolution tandem mass spectra for identification of peptides using the Mascot database search algorithm. A strategy for (1) selection of fragment ion peaks from MS/MS spectra, (2) utilization of improved mass accuracy of the precursor ions, and (3) wavelet denoising of the mass spectra prior to fragment ion selection have been developed. The number of peptide identifications obtained using the enhanced processing was then compared with that obtained using software provided by the instrument manufacturer. Approximately 9000 MS/MS spectra acquired by the Applied Biosystems 4700 TOF/TOF MS instrument were used as a model data set. After application of the new processing, an increase of 33% unique peptides and 22% protein identifications with at least two unique peptides were found. The influence of the processing on the percentage of false positives, estimated by searching against a randomized database, was estimated to increase false positive identifications from 2.7 to 3.9%, which was still below the 5% error rate specified in the Mascot search. These data processing approaches increase the amount of information that can be extracted from LC-MS analysis without the necessity of additional experiments.


Asunto(s)
Almacenamiento y Recuperación de la Información , Péptidos/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Algoritmos
10.
Anal Chem ; 75(22): 6314-26, 2003 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-14616016

RESUMEN

A new denoising and peak picking algorithm (MEND, matched filtration with experimental noise determination) for analysis of LC-MS data is described. The algorithm minimizes both random and chemical noise in order to determine MS peaks corresponding to sample components. Noise characteristics in the data set are experimentally determined and used for efficient denoising. MEND is shown to enable low-intensity peaks to be detected, thus providing additional useful information for sample analysis. The process of denoising, performed in the chromatographic time domain, does not distort peak shapes in the m/z domain, allowing accurate determination of MS peak centroids, including low-intensity peaks. MEND has been applied to denoising of LC-MALDI-TOF-MS and LC-ESI-TOF-MS data for tryptic digests of protein mixtures. MEND is shown to suppress chemical and random noise and baseline fluctuations, as well as filter out false peaks originating from the matrix (MALDI) or mobile phase (ESI). In addition, MEND is shown to be effective for protein expression analysis by allowing selection of a large number of differentially expressed ICAT pairs, due to increased signal-to-noise ratio and mass accuracy.


Asunto(s)
Algoritmos , Cromatografía Liquida/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Artefactos , Factores de Tiempo
11.
Rapid Commun Mass Spectrom ; 17(19): 2177-87, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14515315

RESUMEN

Close deposition of the sample and external standard was used in axial matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to achieve mass accuracy equivalent to that obtained with an internal standard across the entire MALDI plate. In this work, the sample and external standard were deposited by continuous deposition in separate traces, each approximately 200 micro m wide. The dependence of the mass accuracy on the distance between the sample and standard traces was determined across a MALDI target plate with dimensions of 57.5 mm x 57.0 mm by varying the gap between the traces from 100 micro m to 4 mm. During acquisition, two adjacent traces were alternately irradiated with a 200-Hz laser, such that the peaks in the resulting mass spectra combined the sample and external standard. Ion suppression was not observed even when the peptide concentrations in the two traces differed by more than two orders of magnitude. The five peaks from the external standard trace were used in a four-term mass calibration of the masses of the sample trace. The average accuracy across the whole plate with this method was 5 ppm when peaks of the sample trace had signal-to-noise ratios of at least 30 and the gap between the traces was approximately 100 micro m. This approach was applied to determining peptide masses of a reversed-phase liquid chromatographic (LC) separation of a tryptic digest of beta-galactosidase deposited as a long serpentine trace across the MALDI plate, with accuracy comparable to that obtainable using internal calibration. In addition, the eluent from reversed-phase LC separation of a strong cation-exchange fraction containing tryptic peptides from a yeast lysate along with the closely placed external standard was deposited on the MALDI plate. The data obtained in the MS and MS/MS modes on a MALDI-TOF/TOF mass spectrometer were combined and used in database searching with MASCOT. Since the significant score is a function of mass accuracy in the MS mode, database searching with high mass accuracy reduced the number of false positives and also added peptides which otherwise would have been eliminated at lower mass accuracy (false negatives).


Asunto(s)
Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/normas , Calibración , Humanos , Péptidos/análisis , Péptidos/química , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Levaduras/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA