1.
Nano Lett ; 14(9): 5218-23, 2014 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-25089588

RESUMEN

Metallic point contacts (MPCs) with dimensions comparable to the Fermi wavelength of conduction electrons act as electronic waveguides and might operate as plasmon transmitters. Here we present a correlated study of optical and conductance response of MPCs under irradiation with laser light. For elucidating the role of surface plasmon polaritons (SPPs), we integrate line gratings into the leads that increase the SPP excitation efficiency. By analyzing spatial, polarization, and time dependence, we identify two SPP contributions that we attribute to transmitted and decaying SPPs, respectively. The results demonstrate the role of SPPs for optically controlling the transport in metallic nanostructures and are important for designing opto-nanoelectronic devices.

2.
Beilstein J Nanotechnol ; 3: 703-11, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23213634

RESUMEN

We report on the electronic transport through nanoscopic metallic contacts under the influence of external light fields. Various processes can be of relevance here, whose underlying mechanisms can be studied by comparing different kinds of atomic contacts. For this purpose two kinds of contacts, which were established by electrochemical deposition, forming a gate-controlled quantum switch (GCQS), have been studied. We demonstrate that in these kinds of contacts thermal effects resulting from local heating due to the incident light, namely thermovoltage and the temperature dependences of the electrical resistivity and the electrochemical (Helmholtz) double layer are the most prominent effects.

3.
Int J Hyg Environ Health ; 211(3-4): 258-62, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17942365

RESUMEN

Air cooling units are said to pose a health risk to humans because of residual water and biological contamination. We measured particles 0.5 and 5 microm, ultrafine particles and bacterial counts near the outlet of 38 air cooling units and at the corresponding workplaces. Control measurements were performed in 17 rooms without air cooling units. There was no difference between bacterial counts measured near the outlet, at the typical workplaces and in control rooms. Measured bacterial counts near the outlet were between 15 and 950 cfu/m(3) (median 150), at the typical workplaces between 20 and 1685 cfu/m(3) (median 213) and in control rooms between 75 and 940 cfu/m(3) (median 240). Concentrations of particles and ultrafine particles were less in rooms with air cooling units than in control rooms. Thus, we could not find an impairment of air quality by air cooling units in our study. These results should be tested again in a greater study, primarily in another building than a hospital.


Asunto(s)
Aire Acondicionado , Microbiología del Aire , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Material Particulado/análisis , Aire Acondicionado/instrumentación , Aire Acondicionado/normas , Recuento de Colonia Microbiana , Monitoreo del Ambiente/métodos , Alemania , Calefacción , Proyectos Piloto , Factores de Tiempo
4.
Int J Hyg Environ Health ; 208(6): 455-60, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16325554

RESUMEN

We measured bacterial and particle concentrations at the level of operative fields during 105 operation procedures under laminar air flow conditions. Measured concentrations were at least a factor of 20 lower than in comparable rooms without ultra-clean air and laminar air flow. Kind of operation (septic/aseptic), number of participating persons and quantity of talking seem to have less influence on air quality than presumed, single use cover improves the air quality. The number of ultra-fine and small particles was dramatically increased when tissue was coagulated during operation. This may pose health risks to surgeons and nurses, needs risk assessment and decisions about personal protection.


Asunto(s)
Quirófanos , Ropa de Protección , Ventilación , Movimientos del Aire , Bacterias/aislamiento & purificación , Cauterización , Monitoreo del Ambiente , Humanos , Tamaño de la Partícula , Personal de Hospital , Factores de Riesgo , Procedimientos Quirúrgicos Operativos
5.
Ger Med Sci ; 2: Doc04, 2004 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-19675687

RESUMEN

Insufficient performance of cleaning and disinfection of flexible endoscopes can pose an infection risk to patients. Actually quality of reprocessing is checked by performing microbiological cultures. Unfortunately, their results are not available on the same day so that more rapid methods are desirable. We compared the ATP (adenosine triphosphate) bioluminescence for hygiene checking of the reprocessing procedures of 108 flexible endoscopes with routine microbiological culture technics. Sensitivity and specifity of ATP bioluminescence was calculated. 28 endoscopes showed bacterial growth of at least one sample. Depending on the applied threshold of bioluminescence between 67 and 28 endoscopes were positive. Sensitivity varied between 0.46 and 0.75 and specifity between 0.43 and 0.81. ATP bioluminescence does not replace routine microbiologic methods but it can indicate the need of immediate check of reprocessing.