Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 373
Filtrar
1.
J Am Coll Cardiol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39217574

RESUMEN

BACKGROUND: For patients with functional mitral regurgitation (FMR) and symptomatic heart failure (HF), randomized trials of mitral transcatheter edge-to-edge repair (M-TEER) have produced conflicting results. OBJECTIVES: This study sought to assess the impact of M-TEER on hospitalization rates, and explore the effects of M-TEER on patients who did or did not have a history of recent HF hospitalizations before undergoing M-TEER. METHODS: RESHAPE-HF2 (Randomized Investigation of the MitraClip Device in Heart Failure: 2nd Trial in Patients with Clinically Significant Functional Mitral Regurgitation) included patients with symptomatic HF and moderate to severe FMR (mean effective regurgitant orifice area 0.25 cm2; 14% >0.40 cm2, 23% <0.20 cm2) and showed that M-TEER reduced recurrent HF hospitalizations with and without the addition of cardiovascular (CV) death and improved quality of life. We now report the results of prespecified analyses on hospitalization rates and for the subgroup of patients (n = 333) with a HF hospitalization in the 12 months before randomization. RESULTS: At 24 months, the time to first event of CV death or HF hospitalization (HR: 0.65; 95% CI: 0.49-0.85; P = 0.002), the rate of recurrent CV hospitalizations (rate ratio [RR]: 0.75; 95% CI: 0.57-0.99; P = 0.046), the composite rate of recurrent CV hospitalizations and all-cause mortality (RR: 0.74; 95% CI: 0.57-0.95; P = 0.017), and of recurrent CV death and CV hospitalizations (RR: 0.76; 95% CI: 0.58-0.99; P = 0.040), were all lower in the M-TEER group. The RR of recurrent hospitalizations for any cause was 0.82 (95% CI: 0.63-1.07; P = 0.15) for patients in the M-TEER group vs control group patients. Patients randomized to M-TEER lost fewer days due to death or HF hospitalization (13.9% [95% CI: 13.0%-14.8%] vs 17.4% [95% CI: 16.4%-18.4%] of follow-up time; P < 0.0001, and 1,067 vs 1,776 total days lost; P < 0.0001). Patients randomized to M-TEER also had better NYHA functional class at 30 days and at 6, 12, and 24 months of follow-up (P < 0.0001). A history of HF hospitalizations before randomization was associated with worse outcomes and greater benefit with M-TEER on the rate of the composite of recurrent HF hospitalizations and CV death (Pinteraction = 0.03) and of recurrent HF hospitalizations within 24 months (Pinteraction = 0.06). CONCLUSIONS: These results indicate that a broader application of M-TEER in addition to optimal guideline-directed medical therapy should be considered among patients with symptomatic HF and moderate to severe FMR, particularly in those with a history of a recent hospitalization for HF.

2.
IEEE Trans Biomed Eng ; PP2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39106138

RESUMEN

OBJECTIVE: Repetitive atrial activation patterns (RAAPs) during complex atrial tachycardia could be associated with localized mechanisms that can be targeted. Clinically available electroanatomical mapping systems are limited by either the spatial coverage or electrode density of the mapping catheters, preventing the adequate visualization of transiently occurring RAAPs. This work proposes a technique to overcome this shortcoming by stitching spatially overlapping conduction patterns together to a larger image- called a composite map. METHODS: Simulated stable mechanisms and meandering reentries are sequentially mapped (4x4 grid, 3mm spacing) and then reconstructed back to the original sizes with the proposed recurrence plot-based algorithm. RESULTS: The reconstruction of single linear waves presents minimal errors (local activation time (LAT) difference: 3.2 [1.6-4.9] ms, conduction direction difference: 5.2 [2.3-8.0] degrees). Errors significantly increase (p<0.05) for more complex patterns, being the highest with unstable reentries (LAT difference: 10.3 [3.5-16.2] ms, conduction direction difference: 18.2 [6.7-29.7] deg). In a second part of the analysis, 111 meandering reentries are reconstructed. Mapping 30 locations overlappingly around each reentry core was found to be the optimal mapping strategy. For this optimal setting, LAT, conduction direction, and core localization errors are low (6.1 [4.2-8.6] ms, 11.2 [8.6-15.5] deg and 4.1 [2.9-4.9] mm, respectively) and are weakly correlated with the degree of the meander ( ρ=0.41, ρ=0.40 and ρ=0.20, respectively). CONCLUSION: Our findings underline the feasibility of generating composite maps by stitching spatially overlapping recordings. SIGNIFICANCE: Composite maps can be instrumental in personalized ablation strategies.

3.
Open Heart ; 11(2)2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134361

RESUMEN

OBJECTIVES: Sex differences occur in atrial fibrillation (AF), including age at first manifestation, pathophysiology, treatment allocation, complication rates and quality of life. However, optimal doses of cardiovascular pharmacotherapy used in women with AF with or without heart failure (HF) are unclear. We investigated sex-specific associations of beta-blocker and renin-angiotensin system (RAS) inhibitor doses with cardiovascular outcomes in patients with AF or AF with concomitant HF. METHODS: We used data from the prospective Basel Atrial Fibrillation and Swiss Atrial Fibrillation cohorts on patients with AF. The outcome was major adverse cardiovascular events (MACEs), including death, myocardial infarction, stroke, systemic embolisation and HF-related hospitalisation. Predictors of interest were spline (primary analysis) or quartiles (secondary analysis) of beta-blocker or RAS inhibitor dose in per cent of the maximum dose (reference), in interaction with sex. Cox models were adjusted for demographics, comorbidities and comedication. RESULTS: Among 3961 patients (28% women), MACEs occurred in 1113 (28%) patients over a 5-year median follow-up. Distributions of RAS inhibitor and beta-blocker doses were similar in women and men. Cox models revealed no association between beta-blocker dose or RAS inhibitor dose and MACE. In a subgroup of patients with AF and HF, the lowest hazard of MACE was observed in women prescribed 100% of the RAS inhibitor dose. However, there was no association between RAS dose quartiles and MACE. CONCLUSIONS: In this study of patients with AF, doses of beta-blockers and RAS inhibitors did not differ by sex and were not associated with MACE overall.


Asunto(s)
Antagonistas Adrenérgicos beta , Fibrilación Atrial , Humanos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Femenino , Masculino , Anciano , Estudios Prospectivos , Factores Sexuales , Antagonistas Adrenérgicos beta/administración & dosificación , Antagonistas Adrenérgicos beta/efectos adversos , Factores de Riesgo , Persona de Mediana Edad , Suiza/epidemiología , Resultado del Tratamiento , Estudios de Seguimiento , Medición de Riesgo/métodos , Inhibidores de la Enzima Convertidora de Angiotensina/administración & dosificación , Inhibidores de la Enzima Convertidora de Angiotensina/efectos adversos , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Relación Dosis-Respuesta a Droga , Factores de Tiempo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Anciano de 80 o más Años
4.
Int J Cardiol ; 415: 132453, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39151479

RESUMEN

BACKGROUND: Knowledge about impact of age and comorbidities on outcome in patients with leadless pacemakers (LPM) is limited. OBJECTIVES: To analyse outcome in LPM patients according to age and comorbidities. METHODS: This Swiss, multi-centre, retrospective analysis includes all patients with LPM implanted between 2015 and 2022. Charlson-Comorbidity-Index (CCI) was determined and patients were divided into a low- (CCI ≤ 5) and high-comorbidity (CCI > 5) group. Peri-procedural complications, in-hospital death, and all-cause mortalities were assessed. Finally, all-cause mortality according to three groups (CCI ≤ 3, 4-5, >5) was compared to age and sex-adjusted mortality in the general Swiss population. RESULTS: 863 patients (median age 81 years, 65% male, 42% with CCI > 5) were included. Peri-procedural/long-term complication rates did not differ between the low- vs. high-comorbidity groups (2.6% vs. 1.7%, p = 0.48 and 1.2% vs. 2.8%, p = 0.12, respectively). In-hospital (3.6% vs. 0.6%, p = 0.002) and all-cause mortality (HR 2.9, 95%CI 2.2-3.8, p < 0.001) were significantly higher in the high-comorbidity group resulting in a three-year mortality of 58% (95%CI 51-65%) vs. 22% (95%CI 17-27%) in the low-comorbidity group. In patients with a CCI ≤ 3, all-cause mortality was comparable to the age- and sex-adjusted mortality of the general Swiss population. CONCLUSIONS: In elderly patients with high comorbidity, LPM implantation was not associated with increased peri-procedural/long-term complications. All-cause mortality in LPM patients with a CCI ≤ 3 was comparable to age- and sex-adjusted mortality in the general Swiss population. Despite a relatively high three-year mortality due to competing risk factors, LPM implantation is safe, even in elderly patients with high comorbidity. CONDENSED ABSTRACT: In this Swiss, multi-centre, retrospective cohort analysis, 863 patients implanted with a leadless pacemaker were included and divided into a high-comorbidity (with a CCI > 5) and low-comorbidity (with a CCI ≤ 5) group. There was no between group difference in terms of implantation outcomes and peri-operative or long-term complications. Furthermore, all-cause mortality during follow-up in patients with a CCI ≤ 3 was comparable to age- and sex-adjusted mortality in the general Swiss population. These data indicate that LPM implantation is a safe procedure, even in elderly patients with high comorbidity.


Asunto(s)
Comorbilidad , Esperanza de Vida , Marcapaso Artificial , Humanos , Masculino , Femenino , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/tendencias , Anciano de 80 o más Años , Estudios Retrospectivos , Anciano , Suiza/epidemiología , Esperanza de Vida/tendencias , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Mortalidad Hospitalaria/tendencias
5.
N Engl J Med ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39216092

RESUMEN

BACKGROUND: Whether transcatheter mitral-valve repair improves outcomes in patients with heart failure and functional mitral regurgitation is uncertain. METHODS: We conducted a randomized, controlled trial involving patients with heart failure and moderate to severe functional mitral regurgitation from 30 sites in nine countries. The patients were assigned in a 1:1 ratio to either transcatheter mitral-valve repair and guideline-recommended medical therapy (device group) or medical therapy alone (control group). The three primary end points were the rate of the composite of first or recurrent hospitalization for heart failure or cardiovascular death during 24 months; the rate of first or recurrent hospitalization for heart failure during 24 months; and the change from baseline to 12 months in the score on the Kansas City Cardiomyopathy Questionnaire-Overall Summary (KCCQ-OS; scores range from 0 to 100, with higher scores indicating better health status). RESULTS: A total of 505 patients underwent randomization: 250 were assigned to the device group and 255 to the control group. At 24 months, the rate of first or recurrent hospitalization for heart failure or cardiovascular death was 37.0 events per 100 patient-years in the device group and 58.9 events per 100 patient-years in the control group (rate ratio, 0.64; 95% confidence interval [CI], 0.48 to 0.85; P = 0.002). The rate of first or recurrent hospitalization for heart failure was 26.9 events per 100 patient-years in the device group and 46.6 events per 100 patient-years in the control group (rate ratio, 0.59; 95% CI, 0.42 to 0.82; P = 0.002). The KCCQ-OS score increased by a mean (±SD) of 21.6±26.9 points in the device group and 8.0±24.5 points in the control group (mean difference, 10.9 points; 95% CI, 6.8 to 15.0; P<0.001). Device-specific safety events occurred in 4 patients (1.6%). CONCLUSIONS: Among patients with heart failure with moderate to severe functional mitral regurgitation who received medical therapy, the addition of transcatheter mitral-valve repair led to a lower rate of first or recurrent hospitalization for heart failure or cardiovascular death and a lower rate of first or recurrent hospitalization for heart failure at 24 months and better health status at 12 months than medical therapy alone. (Funded by Abbott Laboratories; RESHAPE-HF2 ClinicalTrials.gov number, NCT02444338.).

6.
J Am Coll Cardiol ; 84(10): 921-933, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39197982

RESUMEN

BACKGROUND: Young (<18 years of age) patients with Brugada syndrome (BrS) are often under-represented in BrS studies and their management, especially related to syncopal episodes, remains unclear. OBJECTIVES: This study sought to describe the arrhythmia prevalence among young patients with BrS undergoing continuous rhythm monitoring by implantable loop recorder (ILR) and to assess the etiology behind syncope of undetermined origin. METHODS: A total of 147 patients with BrS with ILR were enrolled in 12 international centers and divided into pediatric (age <12 years; n = 77, 52%) and adolescents (age 13-18 years; n = 70, 48%). RESULTS: Mean age was 11.3 years, 53 patients (36.1%) were female, and 31 (21.1%) had spontaneous type 1 electrocardiograms. Over a median follow-up of 3.6 years (Q1-Q3: 1.6-4.8 years), an arrhythmic event was recorded in 33 patients (22.4%), mainly of nonventricular origin: 15 atrial (10.2%) and 16 bradyarrhythmic events (10.9%). Ventricular arrhythmias occurred in 4 patients, all with spontaneous BrS, and were fever-related in one-half. Among all patients with recurrence of syncope during follow-up, true arrhythmic syncope was documented in 5 (17.8%), and it was due to bradyarrhythmias or atrial arrhythmias in 3 cases (60%). CONCLUSIONS: Continuous rhythm monitoring with ILRs in young patients with BrS detects a broad range of arrhythmias. Ventricular arrhythmias occur predominantly in patients with spontaneous type 1 electrocardiograms and during fever. Despite the young age, bradyarrhythmias and atrial arrhythmias are frequent and represent the cause of arrhythmic syncope in 60% of patients. Young patients with BrS with syncope of undetermined origin may benefit from ILR implant.


Asunto(s)
Síndrome de Brugada , Electrocardiografía Ambulatoria , Humanos , Adolescente , Femenino , Masculino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/complicaciones , Niño , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Estudios de Seguimiento , Síncope/diagnóstico , Síncope/etiología , Síncope/fisiopatología
7.
Int J Cardiol ; 412: 132320, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38964549

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients with heart failure (HF). Real-world data about long-term outcomes and rhythm control interventions use in AF patients with and without HF remain scarce. METHODS: AF patients from two prospective, multicentre studies were classified based on the HF status at baseline into: HF with preserved ejection fraction (HFpEF), HF with reduced or mildly reduced ejection fraction (HFrEF/HFmrEF), and no HF. The prespecified primary outcome was risk of HF hospitalisation. Other outcomes of interest included mortality, cardiovascular events, AF progression, and quality of life. RESULTS: A total of 1265 patients with AF were analysed (mean age 69.6 years, women 27.4%) with a median follow-up of 5.98 years. Patients with HFpEF (n = 126) had a 2.69-fold and patients with HFrEF/HFmrEF (n = 308) had a 2.12-fold increased risk of HF hospitalisation compared to patients without HF (n = 831, p < 0.001). Similar results applied for all-cause and cardiovascular mortality. The risk for AF progression was higher for patients with HFpEF and HFrEF/HFmrEF (6.30 and 6.79 per 100 patient-years, respectively) compared to patients without HF (4.20). The use of rhythm control strategies during follow-up was least in the HFpEF population (4.56 per 100 patient-years) compared to 7.74 in HFrEF/HFmrEF and 8.03 in patients with no HF. With regards to quality of life over time, this was worst among HFpEF patients. CONCLUSIONS: The presence of HFpEF among patients with AF carried a high risk of HF hospitalisations and AF progression, and worse quality of life. Rhythm control interventions were rarely offered to HFpEF patients. These results uncover an unmet need for enhanced therapeutic interventions in patients with AF and HFpEF.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Fenotipo , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Anciano , Estudios Prospectivos , Prevalencia , Persona de Mediana Edad , Estudios de Seguimiento , Volumen Sistólico/fisiología , Hospitalización/tendencias , Calidad de Vida , Anciano de 80 o más Años , Resultado del Tratamiento , Progresión de la Enfermedad
8.
Circulation ; 150(7): 531-543, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-38939955

RESUMEN

BACKGROUND: Despite major advances in the clinical management of long QT syndrome, some patients are not fully protected by beta-blocker therapy. Mexiletine is a well-known sodium channel blocker, with proven efficacy in patients with sodium channel-mediated long QT syndrome type 3. Our aim was to evaluate the efficacy of mexiletine in long QT syndrome type 2 (LQT2) using cardiomyocytes derived from patient-specific human induced pluripotent stem cells, a transgenic LQT2 rabbit model, and patients with LQT2. METHODS: Heart rate-corrected field potential duration, a surrogate for QTc, was measured in human induced pluripotent stem cells from 2 patients with LQT2 (KCNH2-p.A561V, KCNH2-p.R366X) before and after mexiletine using a multiwell multi-electrode array system. Action potential duration at 90% repolarization (APD90) was evaluated in cardiomyocytes isolated from transgenic LQT2 rabbits (KCNH2-p.G628S) at baseline and after mexiletine application. Mexiletine was given to 96 patients with LQT2. Patients were defined as responders in the presence of a QTc shortening ≥40 ms. Antiarrhythmic efficacy of mexiletine was evaluated by a Poisson regression model. RESULTS: After acute treatment with mexiletine, human induced pluripotent stem cells from both patients with LQT2 showed a significant shortening of heart rate-corrected field potential duration compared with dimethyl sulfoxide control. In cardiomyocytes isolated from LQT2 rabbits, acute mexiletine significantly shortened APD90 by 113 ms, indicating a strong mexiletine-mediated shortening across different LQT2 model systems. Mexiletine was given to 96 patients with LQT2 either chronically (n=60) or after the acute oral drug test (n=36): 65% of the patients taking mexiletine only chronically and 75% of the patients who performed the acute oral test were responders. There was a significant correlation between basal QTc and ∆QTc during the test (r= -0.8; P<0.001). The oral drug test correctly predicted long-term effect in 93% of the patients. Mexiletine reduced the mean yearly event rate from 0.10 (95% CI, 0.07-0.14) to 0.04 (95% CI, 0.02-0.08), with an incidence rate ratio of 0.40 (95% CI, 0.16-0.84), reflecting a 60% reduction in the event rate (P=0.01). CONCLUSIONS: Mexiletine significantly shortens cardiac repolarization in LQT2 human induced pluripotent stem cells, in the LQT2 rabbit model, and in the majority of patients with LQT2. Furthermore, mexiletine showed antiarrhythmic efficacy. Mexiletine should therefore be considered a valid therapeutic option to be added to conventional therapies in higher-risk patients with LQT2.


Asunto(s)
Animales Modificados Genéticamente , Células Madre Pluripotentes Inducidas , Síndrome de QT Prolongado , Mexiletine , Miocitos Cardíacos , Mexiletine/farmacología , Mexiletine/uso terapéutico , Animales , Humanos , Conejos , Miocitos Cardíacos/efectos de los fármacos , Síndrome de QT Prolongado/tratamiento farmacológico , Síndrome de QT Prolongado/fisiopatología , Síndrome de QT Prolongado/genética , Células Madre Pluripotentes Inducidas/efectos de los fármacos , Masculino , Femenino , Adulto , Potenciales de Acción/efectos de los fármacos , Antiarrítmicos/farmacología , Antiarrítmicos/uso terapéutico , Adolescente , Persona de Mediana Edad , Adulto Joven , Canal de Potasio ERG1/genética , Canal de Potasio ERG1/antagonistas & inhibidores , Canal de Potasio ERG1/metabolismo , Frecuencia Cardíaca/efectos de los fármacos , Modelos Animales de Enfermedad , Niño , Resultado del Tratamiento
9.
Eur J Heart Fail ; 26(7): 1608-1615, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38847420

RESUMEN

AIM: The RESHAPE-HF2 trial is designed to assess the efficacy and safety of the MitraClip device system for the treatment of clinically important functional mitral regurgitation (FMR) in patients with heart failure (HF). This report describes the baseline characteristics of patients enrolled in the RESHAPE-HF2 trial compared to those enrolled in the COAPT and MITRA-FR trials. METHODS AND RESULTS: The RESHAPE-HF2 study is an investigator-initiated, prospective, randomized, multicentre trial including patients with symptomatic HF, a left ventricular ejection fraction (LVEF) between 20% and 50% with moderate-to-severe or severe FMR, for whom isolated mitral valve surgery was not recommended. Patients were randomized 1:1 to a strategy of delivering or withholding MitraClip. Of 506 patients randomized, the mean age of the patients was 70 ± 10 years, and 99 of them (20%) were women. The median EuroSCORE II was 5.3 (2.8-9.0) and median plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) was 2745 (1407-5385) pg/ml. Most patients were prescribed beta-blockers (96%), diuretics (96%), angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors (82%) and mineralocorticoid receptor antagonists (82%). The use of sodium-glucose cotransporter 2 inhibitors was rare (7%). Cardiac resynchronization therapy (CRT) devices had been previously implanted in 29% of patients. Mean LVEF, left ventricular end-diastolic volume and effective regurgitant orifice area (EROA) were 31 ± 8%, 211 ± 76 ml and 0.25 ± 0.08 cm2, respectively, whereas 44% of patients had mitral regurgitation severity of grade 4+. Compared to patients enrolled in COAPT and MITRA-FR, those enrolled in RESHAPE-HF2 were less likely to have mitral regurgitation grade 4+ and, on average, HAD lower EROA, and plasma NT-proBNP and higher estimated glomerular filtration rate, but otherwise had similar age, comorbidities, CRT therapy and LVEF. CONCLUSION: Patients enrolled in RESHAPE-HF2 represent a third distinct population where MitraClip was tested in, that is one mainly comprising of patients with moderate-to-severe FMR instead of only severe FMR, as enrolled in the COAPT and MITRA-FR trials. The results of RESHAPE-HF2 will provide crucial insights regarding broader application of the transcatheter edge-to-edge repair procedure in clinical practice.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Índice de Severidad de la Enfermedad , Volumen Sistólico , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/complicaciones , Femenino , Masculino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Anciano , Estudios Prospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento , Persona de Mediana Edad , Fragmentos de Péptidos/sangre , Válvula Mitral/cirugía , Péptido Natriurético Encefálico/sangre , Implantación de Prótesis de Válvulas Cardíacas/métodos , Función Ventricular Izquierda/fisiología
10.
CJC Open ; 6(4): 649-655, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38708054

RESUMEN

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.


Contexte: La stimulation cardiaque sans fil a été établie comme une solution de substitution aux dispositifs transveineux chez certains patients. L'implantation d'un stimulateur cardiaque sans fil est souvent une intervention de novo, mais chez un nombre croissant de patients, ce type de stimulateur est utilisé après l'implantation d'un stimulateur classique. Méthodologie: Une analyse rétrospective de l'efficacité et de l'innocuité de la stimulation cardiaque sans fil dans le contexte de l'implantation d'un stimulateur classique a été réalisée dans deux grands centres suisses. Résultats: Un total de 257 patients consécutifs ayant subi l'implantation d'un stimulateur cardiaque sans fil ont été inclus. Les patients étaient répartis dans deux groupes; le groupe 1 était composé de 233 patients non porteurs d'un stimulateur classique, et le groupe 2, de 24 patients porteurs d'un stimulateur classique in situ. Dans le groupe 2, 20 patients au total (83 %) ont eu besoin d'une extraction de la sonde transveineuse en raison d'une infection, d'un défaut de fonctionnement, ou pour d'autres motifs. Chez 3 patients présentant une infection liée au stimulateur, l'extraction de la sonde et l'implantation d'un stimulateur cardiaque sans fil ont été réalisées simultanément, tandis que dans les 11 autres cas, il s'est écoulé un temps médian de 11,5 jours entre les deux interventions (min.-max. : 2-186 jours). Les paramètres relatifs au dispositif électrique au moment de l'implantation et pendant le suivi n'étaient pas différents entre les deux groupes (moyenne : 12,5 ± 9,3 mois). Huit complications périopératoires importantes (3,1 %) sont survenues (4 cas d'épanchement péricardique, 3 cas d'hémorragie fémorale et 1 cas d'hémorragie intra-abdominale) dans l'ensemble de la cohorte au cours d'une période de 30 jours. Aucune complication ne s'est produite dans le groupe de patients porteurs d'un stimulateur classique. On n'a enregistré aucun cas d'infection, même lorsque l'extraction complète du stimulateur classique infecté a été effectuée avant l'implantation du stimulateur cardiaque sans fil. Conclusions: L'implantation d'un stimulateur cardiaque sans fil chez les patients porteurs d'un stimulateur classique (avec ou sans extraction de ce stimulateur) était une intervention efficace et sûre dans cette population de patients.

11.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
12.
Heart Rhythm ; 21(9): 1686-1694, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38604592

RESUMEN

BACKGROUND: The utility of atrioventricular (AV) optimization (AVO) algorithms remains in question. A substudy of the SMART-AV trial found that patients with prolonged interventricular delays ≥70 ms were more likely to benefit from cardiac resynchronization therapy (CRT) with AVO. The SMART-CRT trial evaluated AVO on the basis of these results, but the study was underpowered. OBJECTIVE: To increase statistical power, data from SMART-AV patients meeting the inclusion criterion of interventricular delay ≥70 ms were pooled with data from SMART-CRT to reassess AVO. METHODS: SMART-CRT and SMART-AV were prospective, randomized, multicenter clinical trials. Patients in both studies were randomized to be programmed with an AVO algorithm (SmartDelay) or fixed AV delay (120 ms). Paired echocardiograms obtained at baseline and 6 months were compared, with CRT response defined as ≥15% reduction in left ventricular end-systolic volume. RESULTS: A total of 451 complete patient data sets were pooled and analyzed. The baseline demographics between studies did not differ statistically in terms of age, sex, left ventricular ejection fraction, or left ventricular end-systolic volume. The AVO group had a greater proportion of CRT responders (SmartDelay, 73.9%; fixed, 63.1%; P = .014) and greater changes in measures of reverse remodeling. SmartDelay patients with a recommended sensed AV delay outside the nominal range (100-120 ms) had 2.3 greater odds of CRT response than fixed AV delay patients. CONCLUSION: Greater CRT response and measures of reverse remodeling were observed in patients with SmartDelay enabled vs a fixed AV delay. This study supports the use of SmartDelay in patients with a CRT indication and interventricular delay ≥70 ms.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Femenino , Masculino , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Anciano , Resultado del Tratamiento , Estudios Prospectivos , Algoritmos , Ecocardiografía , Volumen Sistólico/fisiología , Persona de Mediana Edad , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología
13.
CJC Open ; 6(2Part A): 96-103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38585679

RESUMEN

Background: Impairment of the conduction system is a common complication of transcatheter aortic valve replacement (TAVR), which is typically performed in elderly patients. A leadless pacemaker (LP) may be a suitable option in this frail population, but the available scientific data concerning the efficacy and safety of leadless pacing after TAVR are sparse. The purpose of this analysis was to evaluate the efficacy and safety of LP implantation in patients with relevant bradycardias after TAVR, compared to other indications. Methods: Consecutive patients were retrospectively enrolled. Demographics, background heart diseases, interventional parameters, and follow-up data were collected. Results: A total of 257 consecutive patients who underwent LP implantation were included. In 26 patients, the device was implanted due to bradycardias after TAVR (TAVR group), whereas the remaining 231 patients were in the population without previous TAVR (non-TAVR group). The mean implantation duration (56 ± 22 minutes in the TAVR group vs 48 ± 20 minutes in the non-TAVR group; P = not significant [NS]) and the implantation success rate (100% in the TAVR group vs 98.7% in the non-TAVR group; P = NS) were similar in the 2 cohorts. No significant differences occurred in pacing parameters (sensing, impedance, and threshold, respectively) between the 2 groups, either at implantation or during follow-up. A total of 8 major periprocedural complications (3.1% of patients in total; 3.8% in the TAVR group vs 3.0% in the non-TAVR group; P = NS) occurred within 30 days, without significant difference between the 2 groups. Conclusions: LP implantation appears to be safe and effective in patients after TAVR, and therefore, this procedure is a suitable option for this often old and frail population.


Contexte: L'atteinte du système de conduction cardiaque est une complication courante du remplacement valvulaire aortique par cathéter (RVAC), une intervention habituellement pratiquée chez les patients âgés. Un stimulateur cardiaque sans sonde peut être une option convenable pour cette population fragile, mais les données scientifiques actuelles concernant l'efficacité et l'innocuité de la stimulation sans sonde après un RVAC sont fragmentaires. Cette analyse visait à évaluer l'efficacité et l'innocuité de l'implantation d'un stimulateur cardiaque sans sonde chez des patients atteints de bradycardies pertinentes après un RVAC, comparativement à d'autres indications. Méthodologie: Des patients consécutifs ont été recrutés de manière rétrospective. Les données démographiques, les maladies cardiaques sous-jacentes, les paramètres interventionnels et les données de suivi ont été colligés. Résultats: Un total de 257 patients consécutifs qui se sont fait implanter un stimulateur cardiaque sans sonde ont été inclus. Chez 26 patients, le dispositif a été implanté en raison d'une bradycardie après un RVAC (groupe RVAC), alors que les 231 autres patients formaient la population sans RVAC antérieur (groupe sans RVAC). La durée moyenne de l'intervention d'implantation (56 ± 22 minutes dans le groupe RVAC vs 48 ± 20 minutes dans le groupe sans RVAC; p = non significatif [NS]) et le taux de réussite de l'implantation (100 % dans le groupe RVAC vs 98,7 % dans le groupe sans RVAC; p = NS) étaient similaires dans les deux cohortes. Aucune différence significative n'a été observée dans les paramètres de stimulation (sensibilité, impédance et seuil, respectivement) entre les 2 groupes, que ce soit au moment de l'implantation ou pendant le suivi. Un total de 8 complications périopératoires majeures (3,1 % de l'ensemble des patients; 3,8 % dans le groupe RVAC vs 3,0 % dans le groupe sans RVAC; p = NS) sont survenues dans les 30 jours, sans différence notable entre les 2 groupes. Conclusions: L'implantation d'un stimulateur cardiaque sans sonde semble sûre et efficace après un RVAC; par conséquent, cette intervention représente une option convenable pour cette population souvent âgée et fragile.

14.
JACC Clin Electrophysiol ; 10(5): 916-926, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520434

RESUMEN

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (age 63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; 95% CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Prevención Primaria , Humanos , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Masculino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Persona de Mediana Edad , Anciano , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Estados Unidos/epidemiología , Estudios Retrospectivos
15.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38445836

RESUMEN

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Marcapaso Artificial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicaciones , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Electrocardiografía/métodos , Electrocardiografía Ambulatoria/métodos , Adulto
16.
Eur Heart J ; 45(14): 1269-1277, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38546408

RESUMEN

BACKGROUND AND AIMS: Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. METHODS: This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. RESULTS: The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31-87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9-11.2; P < .001) of all-cause mortality. CONCLUSIONS: Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Sepsis , Humanos , Estudios Retrospectivos , Desfibriladores Implantables/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Antibacterianos/uso terapéutico , Sepsis/etiología , Dispositivos de Terapia de Resincronización Cardíaca , Resultado del Tratamiento
17.
Resuscitation ; 197: 110113, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38218400

RESUMEN

BACKGROUND AND AIMS: The Utstein Based-ROSC (UB-ROSC) score has been developed to predict ROSC in OHCA victims. Aim of the study was to validate the UB-ROSC score using two Utstein-based OHCA registries: the SWiss REgistry of Cardiac Arrest (SWISSRECA) and the Lombardia Cardiac Arrest Registry (Lombardia CARe), northern Italy. METHODS: Consecutive patients with OHCA of any etiology occurring between January 1st, 2019 and December 31st 2021 were included in this retrospective validation study. UB-ROSC score was computed for each patient and categorized in one of three subgroups: low, medium or high likelihood of ROSC according to the UB-ROSC cut-offs (≤-19; -18 to 12; ≥13). To assess the performance of the UB-ROSC score in this new cohort, we assessed both discrimination and calibration. The score was plotted against the survival to hospital admission. RESULTS: A total of 12.577 patients were included in the study. A sustained ROSC was obtained in 2.719 patients (22%). The UB-ROSC model resulted well calibrated and showed a good discrimination (AUC 0.71, 95% CI 0.70-0.72). In the low likelihood subgroup of UB-ROSC, only 10% of patients achieved ROSC, whereas the proportion raised to 36% for a score between -18 and 12 (OR 5.0, 95% CI 2.9-8.6, p < 0.001) and to 85% for a score ≥13 (OR 49.4, 95% CI 14.3-170.6, p < 0.001). CONCLUSIONS: UB-ROSC score represents a reliable tool to predict ROSC probability in OHCA patients. Its application may help the medical decision-making process, providing a realistic stratification of the probability for ROSC.


Asunto(s)
Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Humanos , Paro Cardíaco Extrahospitalario/terapia , Estudios Retrospectivos , Retorno de la Circulación Espontánea , Reanimación Cardiopulmonar/métodos , Hospitalización
18.
Resuscitation ; 194: 110043, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37952575

RESUMEN

AIM: Prior studies have reported increased out-of-hospital cardiac arrests (OHCA) incidence and lower survival during the COVID-19 pandemic. We evaluated how the COVID-19 pandemic affected OHCA incidence, bystander CPR rate and patients' outcomes, accounting for regional COVID-19 incidence and OHCA characteristics. METHODS: Individual patient data meta-analysis of studies which provided a comparison of OHCA incidence during the first pandemic wave (COVID-period) with a reference period of the previous year(s) (pre-COVID period). We computed COVID-19 incidence per 100,000 inhabitants in each of 97 regions per each week and divided it into its quartiles. RESULTS: We considered a total of 49,882 patients in 10 studies. OHCA incidence increased significantly compared to previous years in regions where weekly COVID-19 incidence was in the fourth quartile (>136/100,000/week), and patients in these regions had a lower odds of bystander CPR (OR 0.49, 95%CI 0.29-0.81, p = 0.005). Overall, the COVID-period was associated with an increase in medical etiology (89.2% vs 87.5%, p < 0.001) and OHCAs at home (74.7% vs 67.4%, p < 0.001), and a decrease in shockable initial rhythm (16.5% vs 20.3%, p < 0.001). The COVID-period was independently associated with pre-hospital death (OR 1.73, 95%CI 1.55-1.93, p < 0.001) and negatively associated with survival to hospital admission (OR 0.68, 95%CI 0.64-0.72, p < 0.001) and survival to discharge (OR 0.50, 95%CI 0.46-0.54, p < 0.001). CONCLUSIONS: During the first COVID-19 pandemic wave, there was higher OHCA incidence and lower bystander CPR rate in regions with a high-burden of COVID-19. COVID-19 was also associated with a change in patient characteristics and lower survival independently of COVID-19 incidence in the region where OHCA occurred.


Asunto(s)
COVID-19 , Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Humanos , COVID-19/epidemiología , COVID-19/complicaciones , Reanimación Cardiopulmonar/efectos adversos , Pandemias , Paro Cardíaco Extrahospitalario/epidemiología , Paro Cardíaco Extrahospitalario/terapia , Paro Cardíaco Extrahospitalario/etiología
19.
Comput Biol Med ; 167: 107655, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37976830

RESUMEN

Large high-quality datasets are essential for building powerful artificial intelligence (AI) algorithms capable of supporting advancement in cardiac clinical research. However, researchers working with electrocardiogram (ECG) signals struggle to get access and/or to build one. The aim of the present work is to shed light on a potential solution to address the lack of large and easily accessible ECG datasets. Firstly, the main causes of such a lack are identified and examined. Afterward, the potentials and limitations of cardiac data generation via deep generative models (DGMs) are deeply analyzed. These very promising algorithms have been found capable not only of generating large quantities of ECG signals but also of supporting data anonymization processes, to simplify data sharing while respecting patients' privacy. Their application could help research progress and cooperation in the name of open science. However several aspects, such as a standardized synthetic data quality evaluation and algorithm stability, need to be further explored.


Asunto(s)
Inteligencia Artificial , Electrocardiografía , Humanos , Corazón , Algoritmos , Exactitud de los Datos
20.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37944131

RESUMEN

AIMS: Brugada syndrome (BrS) is an inherited disease associated with an increased risk of ventricular arrhythmias. Recent studies have reported the presence of an altered atrial phenotype characterized by abnormal P-wave parameters. The aim of this study was to identify BrS based exclusively on P-wave features through an artificial intelligence (AI)-based model. METHODS AND RESULTS: Continuous 5 min 12-lead ECG recordings were obtained in sinus rhythm from (i) patients with spontaneous or ajmaline-induced BrS and no history of AF and (ii) subjects with suspected BrS and negative ajmaline challenge. The recorded ECG signals were processed and divided into epochs of 15 s each. Within these epochs, P-waves were first identified and then averaged. From the averaged P-waves, a total of 67 different features considered relevant to the classification task were extracted. These features were then used to train nine different AI-based supervised classifiers. A total of 2228 averaged P-wave observations, resulting from the analysis of 33 420 P-waves, were obtained from 123 patients (79 BrS+ and 44 BrS-). Averaged P-waves were divided using a patient-wise split, allocating 80% for training and 20% for testing, ensuring data integrity and reducing biases in AI-based model training. The BrS+ patients presented with longer P-wave duration (136 ms vs. 124 ms, P < 0.001) and higher terminal force in lead V1 (2.5 au vs. 1.7 au, P < 0.01) compared with BrS- subjects. Among classifiers, AdaBoost model had the highest values of performance for all the considered metrics, reaching an accuracy of over 81% (sensitivity 86%, specificity 73%). CONCLUSION: An AI machine-learning model is able to identify patients with BrS based only on P-wave characteristics. These findings confirm the presence of an atrial hallmark and open new horizons for AI-guided BrS diagnosis.


Asunto(s)
Fibrilación Atrial , Síndrome de Brugada , Humanos , Fibrilación Atrial/inducido químicamente , Inteligencia Artificial , Ajmalina/efectos adversos , Electrocardiografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA