1.
Mikrochim Acta ; 191(2): 118, 2024 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-38296851

RESUMEN

Highly specific detection of tumor-associated biomarkers remains a challenge in the diagnosis of prostate cancer. In this research, Maackia amurensis (MAA) was used as a recognition element in the functionalization of an electrochemical impedance-spectroscopy biosensor without a label to identify cancer-associated aberrant glycosylation prostate-specific antigen (PSA). The lectin was immobilized on gold-interdigitated microelectrodes. Furthermore, the biosensor's impedance response was used to assess the establishment of a complex binding between MAA and PSA-containing glycans. With a small sample volume, the functionalized interdigitated impedimetric-based (IIB) biosensor exhibited high sensitivity, rapid response, and repeatability. PSA glycoprotein detection was performed by measuring electron transfer resistance values within a concentration range 0.01-100 ng/mL, with a detection limit of 3.574 pg/mL. In this study, the ability of MAA to preferentially recognize α2,3-linked sialic acid in serum PSA was proven, suggesting a potential platform for the development of lectin-based, miniaturized, and cost effective IIB biosensors for future disease detection.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Próstata , Masculino , Humanos , Lectinas/química , Biomarcadores de Tumor , Antígeno Prostático Específico , Maackia/metabolismo , Próstata/metabolismo , Neoplasias de la Próstata/diagnóstico , Técnicas Biosensibles/métodos
2.
Mikrochim Acta ; 188(8): 257, 2021 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34268634

RESUMEN

A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD < 5%. Hence, the demonstrated S-4 strategy is highly recommended for other downstream biosensors applications.


Asunto(s)
Biomarcadores/sangre , Oro/química , Grafito/química , Troponina I/sangre , Técnicas Biosensibles , Espectroscopía Dieléctrica , Compuestos Epoxi/química , Humanos , Hidróxidos/química , Inmunoensayo , Cinética , Límite de Detección , Microelectrodos , Nanoestructuras , Propilaminas/química , Silanos/química , Propiedades de Superficie
3.
Curr Med Chem ; 23(37): 4270-4284, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27719655

RESUMEN

Cardiovascular disease (CVD) is a major threat to global health, estimated to be the cause 30 % (17.3 million in 2008) of deaths every year, and the number of deaths caused by CVD is expected to increase further, reaching 23.3 million by 2030. Hence, there is a growing demand for simpler sample extraction, rapid screening results, and intervention of the subsequent analysis in emergency units. In this paper, we reviewed CVD biomarkers in blood- and saliva-based specimens. The history of cardiac biomarkers indicates that in the beginning, cardiac troponin I (cTnI) was a widely accepted 'gold standard' marker due to its high specificity and selectivity. Considering the advantages of salivary-based cardiac biomarkers, we examined correlations between non-invasive (salivary) and invasive (blood) diagnoses, and it was found that C-reactive protein (CRP) provides a better correlation. Despite the low abundance of salivary CRP, several reports displayed the detection limit down to pg/ml using existing technologies. Thus, salivary CRP has the potential to be used for future forefront diagnostics for the early assessment of cardiac risks.


Asunto(s)
Biomarcadores/análisis , Enfermedades Cardiovasculares/diagnóstico , Aspartato Aminotransferasas/sangre , Biomarcadores/sangre , Proteína C-Reactiva/análisis , Enfermedades Cardiovasculares/metabolismo , Creatina Quinasa/sangre , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/metabolismo , Mioglobina/análisis , Saliva/metabolismo , Troponina I/sangre