Your browser doesn't support javascript.
loading
Casein/ferric chloride/polyvinyl alcohol composite for specific in-syringe colorimetric detection of formaldehyde in Hevea brasiliensis latex.
Hama, Nuryanee; Cheewasedtham, Wilairat; Rujiralai, Thitima.
Afiliação
  • Hama N; Center of Excellence for Innovation in Chemistry, Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
  • Cheewasedtham W; Analytical Chemistry and Environment Research Unit, Division of Science, Faculty of Science and Technology, Prince of Songkla University, Pattani, 94000, Thailand.
  • Rujiralai T; Analytical Chemistry and Environment Research Unit, Division of Science, Faculty of Science and Technology, Prince of Songkla University, Pattani, 94000, Thailand.
Mikrochim Acta ; 191(7): 421, 2024 Jun 26.
Article em En | MEDLINE | ID: mdl-38918206
ABSTRACT
A new, simple, and selective colorimetric method of determining formaldehyde in Hevea brasiliensis latex was developed by using a casein/ferric chloride/polyvinyl alcohol hydrogel composite (casein/FeCl3/PVA) in a modified Leach test. Under heating, formaldehyde reacted with 8% casein in the presence of 0.1% FeCl3 and 4.3% HCl (v/v) entrapped in a 30% PVA hydrogel packed in a syringe. A purple-colored product was formed with a maximum absorbance of 525 nm. The color change was evaluated at the color detection zone indicated on the the syringe. The %magenta values were easily evaluated by using a mobile phone application and employed to determine formaldehyde content. The casein/FeCl3/PVA composite gave a readable response in a formaldehyde detection range from 0.04 to 0.80% with a linear response between %magenta and formaldehyde concentration (R2 = 0.9955). The detection limit was 0.032%, and precisions were in the range 0.67-4.94%. The casein/FeCl3/PVA composite was applied to the analysis of ammonia-preserved latex samples, and recoveries of formaldehyde from samples spiked at 0.1, 0.3, and 0.5% ranged from 81.55 to 99.51% (RSDs ≤ 5.41%). The recoveries and precision of the proposed method were comparable with those of high-performance liquid chromatography (HPLC). The developed method was also selective, showing no interference from other latex preservatives, i.e., phenol, ammonia, or tetramethylthiuram disulfide.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE País/Região como assunto: America do sul / Brasil Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Tailândia País de publicação: Áustria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE País/Região como assunto: America do sul / Brasil Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Tailândia País de publicação: Áustria