Your browser doesn't support javascript.
loading
Use of FreeStyle Libre for continuous glucose monitoring in adult horses.
Françoso, Rafael; Baccarin, Raquel Y; de Siqueira, Renata F; Belli, Carla B.
Afiliação
  • Françoso R; Centro de Ciências Agrárias, Universidade Estadual da Região Tocantins do Maranhão, Imperatriz, Brazil.
  • Baccarin RY; Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo, São Paulo, Brazil.
  • de Siqueira RF; Departamento de Clínica de Grandes Animais, Centro de Ciências Rurais da Universidade Federal de Santa Maria, Santa Maria, Brazil.
  • Belli CB; Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo, São Paulo, Brazil.
Article em En | MEDLINE | ID: mdl-38459745
ABSTRACT

OBJECTIVES:

To evaluate the feasibility of using the FreeStyle Libre (a continuous glucose monitoring system [CGMS]) for instantaneous continuous monitoring of interstitial glucose in adult horses and examine the applicability and accuracy of this system in horses submitted to combined glucose-insulin test (CGIT).

DESIGN:

Laboratory measurements and continuous glucose monitoring system (CGMS) readings were analyzed using a 2 × 2 factorial statistical model with repeated measures over time. This analysis assessed the effects of the test (factor 1), group (factor 2), and their interactions (test × group, test × time, and group × time). Pearson's correlation analysis was applied to blood glucose values. Mean comparisons were conducted using the t-test, and agreement between techniques was assessed via the Bland-Altman method, with a 95% confidence interval.

SETTING:

Field study on private horse farms in association with a veterinary school. ANIMALS Ten healthy stallions were assigned to one of two groups based on their body condition scores (BCS). Group 1 (G1, n = 5) consisted of nonobese horses with a BCS of 5 or 6, while Group 2 (G2, n = 5) consisted of obese horses with a BCS of 7 or higher.

INTERVENTIONS:

A CGMS sensor was attached to the dorsolateral aspect of the proximal one third of each horse's neck. Laboratory blood glucose measurements and CGMS interstitial glucose readings were compared at different time points for up to 7 days after sensor fixation. Obese horses were also submitted to CGIT on Day 4. MEASUREMENTS AND MAIN

RESULTS:

A comparative analysis of glucose measurements obtained in G1 and G2 horses using the CGMS and enzymatic methods revealed significant group × time interactions (P < 0.001) and time effects (P < 0.001). No interactions were detected between group (P = 0.45), test (P = 0.62), group and test (P = 0.28), or time and test (P = 0.92). In G1 and G2, tests were significantly correlated (r = 0.84 and P = 0.00) at all time points (T0-T5). Agreement between the glucose values obtained using different methods was excellent despite a small time delay in CGMS detection of rapid changes in blood glucose.

CONCLUSIONS:

It was concluded that the CGMS can be used for indirect assessment of glycemic status (ie, based on interstitial glucose measurements) in nonobese and obese adult horses submitted to CGIT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Doenças dos Cavalos Limite: Animals Idioma: En Revista: J Vet Emerg Crit Care (San Antonio) Assunto da revista: MEDICINA DE EMERGENCIA / MEDICINA VETERINARIA / TERAPIA INTENSIVA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Doenças dos Cavalos Limite: Animals Idioma: En Revista: J Vet Emerg Crit Care (San Antonio) Assunto da revista: MEDICINA DE EMERGENCIA / MEDICINA VETERINARIA / TERAPIA INTENSIVA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos