Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis.
Vaz, Gilvan Ferreira; Freire, Felipe Florêncio; Gonçalves, Henrique Mansur; de Aviz, Marcus Alexandre Brito; Martins, Wagner Rodrigues; Durigan, João Luiz Quagliotti.
Afiliação
  • Vaz GF; Faculty of Ceilândia, Rehabilitation Sciences Program, University of Brasilia, Brasília, DF, Brazil.
  • Freire FF; Medicine Division, Department of Orthopaedics, Hospital das Forças Armadas (HFA), Brasília, DF, Brazil.
  • Gonçalves HM; Medicine Division, Department of Orthopaedics, Hospital das Forças Armadas (HFA), Brasília, DF, Brazil.
  • de Aviz MAB; Orthopedic Department of the Santa Helena Hospital, Brasília, DF, Brazil.
  • Martins WR; Anesthesiology Department of the Institute Hospital de Base, Brasília, DF, Brazil.
  • Durigan JLQ; Faculty of Ceilândia, Rehabilitation Sciences Program, University of Brasilia, Brasília, DF, Brazil.
PLoS One ; 18(6): e0278086, 2023.
Article em En | MEDLINE | ID: mdl-37289803
INTRODUCTION: The handheld dynamometer has been validated to measure muscle strength in different muscle groups. However, to date, it has not been tested in individuals who experience pain induced by hip osteoarthritis. The current study aimed to evaluate the intra- and inter-rater reliability, agreement, and minimal detectable change of the Lafayette handheld dynamometer, model 1165, to assess the peak force (Pk) and average peak force (Af) of hip muscles in individuals with symptomatic hip osteoarthritis. METHODS: Twenty participants with hip osteoarthritis (mean ± SD age: 58.7±15.3 years; body mass index: 28.8±4.2 kg/m2) and pain intensity on the Visual Analogue Scale ≥ 4 (8.05±1.2) were recruited to participate in this study. Pk and Af of hip flexors (seated position), abductors and adductors (supine position), and extensors (prone position) were collected in a single day by two independent raters, each one obtaining test and retest in randomly ordered separate sessions. RESULTS: The intra-rater intraclass correlation coefficient (ICC) was classified as good (>0.75) or excellent (≥0.90) for all muscle groups and all inter-rater ICCs were classified as excellent. Rater A had a lower standard error of measurement compared to rater B, ranging from 0.15 to 0.58 kilogram-force (Kgf) compared with 0.34 to 1.25 kg, respectively. However, the inter-rater comparison showed a minimal detectable change (MDC) of < 10% for all Pk and Af measures for hip adductors and extensors. Finally, the inter-rater Bland-Altman analysis demonstrated good agreement for abductors, adductors, and extensors. CONCLUSION: Despite pain and dysfunction related to hip osteoarthritis, the mean of two measures using a handheld dynamometer was shown to be a reliable tool to assess hip muscle strength, with good to excellent intra- and inter-rater ICCs, satisfactory agreement, and small values for MDC.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Quadril Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Humans / Middle aged Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Quadril Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Humans / Middle aged Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos